• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 79
  • 79
  • 79
  • 37
  • 32
  • 20
  • 20
  • 14
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Associação entre polimorfismos genicos e perda precoce de implantes osseointegrados

Santos, Maria Cristina Leme Godoy dos 03 August 2018 (has links)
Orientador : Sergio Roberto Peres Line / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T20:20:26Z (GMT). No. of bitstreams: 1 Santos_MariaCristinaLemeGodoydos_M.pdf: 1023278 bytes, checksum: 6fa97d0d1fd0235f7d3d1de05cbed32d (MD5) Previous issue date: 2004 / Mestrado
2

Proposição de estabelecimento dos protocolos de coleta de tecido ósseo, cultura primária e linhagem celular, e de caracterização de células humanas semelhantes a osteoblastos, oriundas da mandíbula

Zortéa Júnior, Alberto João January 2006 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T16:32:31Z (GMT). No. of bitstreams: 1 241825.pdf: 1265824 bytes, checksum: e3eddb973f6cbfc318b76c8783d96909 (MD5)
3

Avaliação ao longo do tempo da osseointegração em 93 implantes em forma de platôs removidos de humanos

Gil, Luiz Fernando January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:04:50Z (GMT). No. of bitstreams: 1 327158.pdf: 831762 bytes, checksum: 7954cc7d9bd4484428bd1e4c54427f71 (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar a osseointegração de implantes em forma de platôs removidos de humanos considerando o tempo de carga funcional e a variáveis relativas ao sistema de implante utilizado e a fatores ligados ao paciente. Foi realizada análise histomorfométrica (BIC/BAFO) em 93 implantes platôs funcionais removidos de humanos por razões protéticas, seguido da obtenção de dados relativos ao paciente e aos sistemas de implantes empregados, bem como o tempo de carga funcional. BIC, BAFO e o tempo de carga funcional foram correlacionados através do teste ANOVA a múltiplas variáveis independentes: tipo da superfície do implante, diâmetro, comprimento, maxilar (maxila/mandíbula) e região (anterior/posterior) de instalação; análise de regressão linear foi utilizada para avaliar a relação entre o tempo de carga funcional e BIC/BAFO. Os valores de BIC (R= .38, p < .001) e BAFO (R = .25, p < .02) aumentaram em função do tempo de carga funcional, entretanto, não puderam ser estatisticamente relacionados a nenhuma variável independente. Conclui-se que o aumento da osseointegração ao longo do tempo se dá independentemente de fatores relacionados ao paciente e aos sistemas de implantes.<br> / Abstract : The aim of this study was to assess the osseointegration in plateau root form implants as a function of functional loading time and implant/ patient related variables. Histomorphometric analysis (BIC/BAFO) was performed in 93 functional plateau root form implants retrieved due to prosthetic reasons, followed by patient?s chart analyses in order to obtain implant/patient related data as well as time of functional loading. ANOVA test was used to correlate BIC, BAFO and time of functional loading to multiple independent variables: implant surface type, diameter, length, arch (maxilla/mandible) and region (anterior/posterior) of placement; linear regression analysis was applied to assess the relationship between time of functional loading and BIC/BAFO. BIC (R= .38, p < .001) and BAFO (R = .25, p < .02) values increased in function of time of functional loading, however, BIC/BAFO were not statistically related to any of the independent variables. It may be concluded that osseointegration increases in function of time independently of implant system/patient related parameters.
4

Avaliação da manutenção óssea em implantes instalados a partir da abordagem trimodal: acompanhamento de 1-4 anos

Sczepanik, Fábio Sá Carneiro January 2015 (has links)
Made available in DSpace on 2015-05-29T12:51:02Z (GMT). No. of bitstreams: 1 000469538-Texto+Completo-0.pdf: 1770446 bytes, checksum: 90b8e8696e775e37ea2dd8f6aec011bc (MD5) Previous issue date: 2015 / Purpose : The purpose of this retrospective investigation was to evaluate, radiographically and clinically, a group of patients treated with immediate single-tooth placement, immediate restoration implants with a customized definitive abutment with a flapless approach in the area between both maxillary canines. Marginal bone level (MBL) and marginal bone level of neighboring teeth (MBLN) were assessed.Methods : A sample of 20 subjects received 20 tapered platform-switching implants using a minimally invasive surgery (trimodal approach). The mean age was 55. 2 years (range 25 - 71 years), and the mean follow-up period was 2. 2 years (range 12 - 48 months).Results : The overall treatment survival was 100%. There was no statistically significant difference between MBLN in both mesial and distal aspects, comparing baseline to final follow-up and between the four radiographs independently (i. e. , at baseline, at 06 months, at 12 months, and at final follow-up). There was a statistically significant difference between MBL in both mesial and distal aspects at baseline and at final follow-up (p<0. 05).Conclusion : Within the limitations of this study, it has demonstrated that the trimodal approach might offer an advantage in terms of marginal bone levels, especially in MBLN, in a mean follow-up time of 26 months. Additionally, reduced overall treatment time, one surgical intervention, and immediate esthetics can be obtained with 100% survival and success rates using a minimally invasive approach. / Objetivos : O objetivo desta investigação retrospectiva foi avaliar, radiograficamente e clinicamente, um grupo de pacientes tratados com instalação imediata de implantes unitários, provisório imediato com um pilar protético personalizado, com uma abordagem sem descolamento de retalho mucoperiostal na região ântero superior. Nível da crista óssea marginal e crista óssea marginal a nível dos dentes adjacentes foram avaliados.Materiais e métodos : Uma amostra de 20 indivíduos recebeu 20 implantes cônicos com mudança de plataforma através de uma abordagem minimamente invasiva (abordagem trimodal). A média de idade foi de 55,2 anos (variando de 25 a 71 anos) e o período médio de acompanhamento foi de 2,2 anos (variando de 12 a 48 meses).Resultados : A taxa total de sobrevivência dos implantes e coroas definitivas foi de 100%. Não houve diferença estatisticamente significativa entre MBLN nas faces mesial e distal, comparando-se baseline ao controle final, assim como não houve entre as quatro radiografias independentemente (i. e. baseline, 6 meses, 12 meses e controle final). Houve diferença estatisticamente significativa entre MBL nas faces mesial e distal entre baseline e o controle final (p<0,05).Conclusão : Dentro das limitações deste estudo, demonstramos que a abordagem trimodal pode oferecer uma vantagem em termos de níveis de crista óssea marginal, especialmente em MBLN, durante um período médio de acompanhamento de 26 meses. Adicionalmente, reduzido tempo total de tratamento, apenas uma etapa cirúrgica e estética imediata podem ser obtidos com 100% de taxas de sobrevivência e sucesso, utilizando uma abordagem minimamente invasiva.
5

Torque de remoção de implantes lisos e texturizados com e sem estabilidade primária associados ou não ao plasma rico em plaquetas

Suzuki, Roberto Makoto January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:00Z (GMT). No. of bitstreams: 2 000399345-0.pdf: 1607663 bytes, checksum: 3e900d3262bbff08d819d4414119f515 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Rough implant surfaces and platelet-rich plasma are thought to enhance titanium osseointegration. Torque removal forces have been used as a biomechanical measurement of endosseous integration or bone anchorage, in which higher forces required to remove implants from the bone may be interpreted as an increase in the strength of bony integration. The purpose of this study was to evaluate the effect of primary stability of machined implants (MI) and sandblasted/acid-etched (SBAE) titanium implants associated with platelet-rich plasma (PRP) on the resistance to reverse torque removal. These factors were evaluated in six groups: 1- MI with primary stability and without PRP; 2- MI without primary stability and without PRP; 3- MI without primary stability and with PRP; 4- SBAE with primary stability and without PRP; 5- SBAE without primary stability and without PRP; 6- SBAE without primary stability and with PRP. Forty two implants were inserted in seven adult New Zealand white rabbits (Oryctolagos Cuniculus L. ). Three implants were inserted in each tibiae according to the above described groups. After a healing period of 9 weeks the animals were sacrificed and the implants were removed by reverse torque rotation with a digital torque-measuring device. Mean torque values were: 1- 53,01 Ncm (±9,68); 2- 45,29 Ncm (±16, 90); 3- 43,43 Ncm (±16,70); 4- 56,60 Ncm (±16,00); 5- 46,89 Ncm (±15,60) and 6- 48,49 Ncm (±17,06), respectively. No significant difference was detected among the groups (p>0,05). In this study it was not possible to demonstrated a statistically significant improved stability of implants subjected to PRP and texturized implants as compared to other groups. / O objetivo desse estudo foi avaliar o torque de remoção de implantes lisos e texturizados sem estabilidade primária associados a plasma rico em plaquetas. Foi utilizado um total de sete coelhos fêmeas, brancas da raça Nova Zelândia Branco (Oryctolagos cuniculus l. ). Em cada coelho foram instalados 6 implantes, 3 para cada tíbia, de acordo com os seguintes grupos experimentais: 1- implante liso com estabilidade primária e sem PRP (plasma rico em plaquetas); 2- implante liso sem estabilidade primária e sem PRP; 3- implante liso sem estabilidade primária e com PRP; 4- implante texturizado com estabilidade primária e sem PRP; 5- implante texturizado sem estabilidade primária e sem PRP; 6- implante texturizado sem estabilidade primária e com PRP. Os protocolos cirúrgicos foram aplicados de acordo com cada grupo experimental e após um período de 9 semanas, os animais foram mortos. Logo após a morte dos animais, a mensuração do torque de remoção foi realizada. As médias dos grupos foram: grupo 1, 53,01 Ncm (±9,68); grupo 2, 45,29 Ncm (±16, 90); grupo 3, 43,43 Ncm (±16,70); grupo 4, 56,60 Ncm (±16,00); grupo 5, 46,89 Ncm (±15,60) e grupo 6, 48,49 Ncm (±17,06). Os dados foram analisados através da Análise de Variância Múltipla, utilizando o delineamento em blocos casualizados que demonstrou não haver diferença estatística entre os grupos ao nível de 5% nas condições experimentais estabelecidas. As distintas condições experimentais não foram capazes de promover diferença no torque de remoção.
6

Influência dos fatores locais e sistêmicos na osseointegração e perda óssea ao redor de implantes

Souza, João Gustavo Oliveira de 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-24T23:56:50Z (GMT). No. of bitstreams: 1 284180.pdf: 2168687 bytes, checksum: 3ee357ae46210ab12fa4eb4763918621 (MD5) / A proposta deste estudo foi avaliar, retrospectivamente, o sucesso dos implantes e a influência de fatores locais e sistêmicos na osseointegração e perda óssea ao redor de implantes orais em pacientes que apresentam implantes em função por 1 a 8 anos. Foram selecionados 193 pacientes (753 implantes) que apresentavam implantes cilíndricos, conexão do tipo hexágono externo (Conexão, São Paulo, Brasil) com radiografias mensuráveis, informações dos prontuários preenchidas adequadamente e próteses provisórias ou definitivas por 1 ano, no mínimo. Implantes que se apresentavam osseointegrados sustentando e mantendo a função das respectivas próteses foram considerados como sucesso. Considerouse o restante como perda. Os implantes considerados como sucesso foram divididos em relação à quantidade de perda óssea: < 2 mm; e = 2 mm. Foram coletadas informações em relação a sexo, idade, escolaridade e saúde geral do paciente antes e após a instalação dos implantes. Em relação aos implantes, coletaram-se informações quanto a suas características, localização, momento da perda, tempo de instalação da prótese e tipo de prótese. Do total, 722 implantes (95,9%) obtiveram sucesso e 31 implantes (4,1%) foram perdidos, sendo 27 removidos na cirurgia de reabertura e 4 após a ativação da prótese. Observa-se que o fumo está associado a um aumento na taxa de perda dos implantes na razão de 2,9 (p < 0,05) antes da instalação dos implantes. Houve diferença estatística na taxa de falhas dos implantes com plataforma estreita #18,9% (p < 0,001). Dos implantes considerados com sucesso, 507 implantes apresentaram perda óssea < 2 mm (70,2%) e 215 implantes # em 67 acientes (34,7%) # apresentaram perda óssea = 2 mm (29,8%). Houve diferença estatística na avaliação da perda óssea no tempo de função do implante, tipo de prótese, comprimento dos implantes e fumo antes do procedimento cirúrgico. Conclui-se que implantes cilíndricos e conexão tipo hexágono externo apresentam excelentes taxas de sucesso e podem ser indicados em larga escala. Implantes com plataforma estreita são contra-indicados para reposição dentes posteriores. Dentre os fatores sistêmicos, apenas o fumo dificulta a obtenção e/ou manutenção da osseointegração. Além disso, o maior período em função do implante, implantes que suportam próteses parciais e totais, implantes = 10 mm e o fumo são fatores relacionados à maior perda óssea peri-implantar. / The purpose of this study was to evaluate retrospectively the success of oral implants and the influence of local and systemic factors on osseointegration and bone loss around implants in patients with oral implants in function for 1-8 years. Were selected 193 patients (753 implants) who had cylindrical implants, with external hexagonal connection (Conexão, São Paulo, Brazil), measurable radiographs, medical records properly completed and provisional or final prosthesis for at least 1 year. Osseointegrated implants that presented themselves sustaining and maintaining the function of their prostheses and who met the inclusion criteria were considered as success. The remainder was considered as a loss. The implants were considered successfully divided over the amount of bone loss: <2 mm, and = 2 mm. Information was collected regarding sex, age, education and general health of the patient before and after the installation of implants. In relation to the implants were collected information regarding their characteristics, location, time of loss, period of installation of prosthesis and type of prosthesis. Of the total, 722 implants (95.9%) were successful, and 31 implants (4.1%) were lost, 27 removed at second stage surgery and 4 after activation of the prosthesis. It is observed that smoking is associated with an increased implants loss in the ratio of 2.9 (p <0.05) before the installation of the implants. There was statistical difference in failure rate of implants with narrow platform - 18.9% (p <0.001). The implants considered successful, 507 implants showed bone loss <2 mm (70.2%) and 215 implants - in 67 patients (34.7%) - showed bone loss = 2 mm (29.8%). There was statistical difference in the evaluation of bone loss at the time of implant function, type of prosthesis, size of implants and smoking before surgery. It is concluded that cylindrical implants with external connection shown excellent success rates and can be displayed on a large scale. Narrow platform implants are contraindicated for replacement posterior teeth. Among the systemic factors only smoking hinders the achievement or maintenance of osseointegration. Moreover, the longest period in function of the implant, implants that support partial and full dentures, implants = 10 mm and smoking are factors associated with greater bone loss around implant.
7

Avaliação biomecânica e histomorfométrica de um recobrimento biocerâmico nanométrico em implantes dentários

Granato, Rodrigo January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2012-10-23T10:46:28Z (GMT). No. of bitstreams: 1 249016.pdf: 628457 bytes, checksum: cfd1cbb13514da16ed0c9050d1bf81e2 (MD5) / O objetivo deste estudo foi avaliar a fixação biomecânica e as respostas biológicas em Implantes dentários com recobrimento de superfície biocerâmico composto por Cálcio e Fósforo de espessura entre 300-500 nanômetros. Para tanto, seis cães Beagle, machos, com aproximadamente um ano e meio de idade receberam 36 implantes dentários endosseos na forma de platôs (Bicon, Boston, MA), sendo 18 com recobrimento biocerâmico (grupo experimental) e 18 sem este recobrimento (grupo controle), divididos em dois períodos in-vivo: 30 e 15 dias antes da eutanásia. Os implantes foram submetidos a teste de resistência ao torque em máquina de torque eletrônica até falha de interface. Após avaliação biomecânica, as peças foram individualizadas e preparadas para avaliação histomorfométrica da taxa de contato osso/implante. Os resultados mostraram um significante aumento nas propriedades biomecânicas no grupo experimental, tanto em 15 quanto em 30 dias de osseointegração. Com relação à taxa de contato osso/implante, um aumento significante favorável ao grupo experimental foi identificado no menor período de osseointegração(15 dias), o que indica uma propriedade do recobrimento utilizado de acelerar o processo de remodelação óssea ao redor de implante endosseo. Os resultados deste estudo sugerem que o tratamento de superfície de implantes dentários na forma de platôs através de recobrimento biocerâmico de ordem nanométrica altera positivamente a dinâmica do remodelamento ósseo ao seu redor.
8

Avaliação das próteses fixas totais sem estrutura metálica, implantossuportadas com carga imediata

Cunha, Hiron Andreaza da 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2008 / Made available in DSpace on 2012-10-24T00:37:30Z (GMT). No. of bitstreams: 1 269710.pdf: 1134622 bytes, checksum: d50293ec4a3817531c6d02ee4992e1b5 (MD5) / Por meio deste estudo foi analisado o comportamento clínico das próteses fixas implantossuportadas sem infra-estrutura metálica submetidas à carga imediata, como tratamento definitivo, em dez pacientes que receberam cinco implantes na mandíbula entre os foramens mentual, somando um total de 50 implantes, cada paciente recebendo uma prótese fixa de 12 elementos sem infra estrutura metálica e uma prótese total superior. Este estudo avaliou ao mesmo tempo a estabilidade inicial e secundaria dos implantes por um período de 24 meses, por meio do Osstell, aparelho que afere a estabiliade do implante por meio de freqüência de ressonância. Os resultados da análise descritiva apresentaram em média uma estabilidade inicial de 71.76 ISQ (Quociente de estabilidade do implante), a estabilidade secundária em média após 6 meses foi de 69,35 ISQ, 12 meses foi de 70.14 ISQ e 24 meses foi de 70.10 ISQ (Quociente de estabilidade do implante), indicando que os implantes estavam estáveis após 24 meses em função. Os resultados são favoráveis aos itens avaliados, não houve fraturas das próteses, não houve afrouxamento ou fraturas dos parafusos de retenção, não houve perda de implantes de nenhum dos cinqüenta implantes instalados, demonstrando ser viável o uso dessa técnica. / This study analyzed the clinical behavior of the implants, submitted to a immediate loading with fixed prosthesis implantsupported without a metallic infrastructure by means of Osstell, for a period of twenty-four months, in ten patients, who received five implants in the mandible between the mentonian foramens, with a total of 50 implants, each patient received a fixed prosthesis of 12 elements without a metallic structure and a superior total prosthetics. During this period it was also evaluated the clinical behavior of the prosthesis, as to the resistance to fracture of the acrylic resin, the unscrewing and fracture of the retention screws of the prosthesis in the masticating function. The results of the descriptive analysis presented an initial stability of 71.76 ISQ (Implant Stability Quotient). The secondary stability, after 6 months, was of 69,30 ISQ; 12 months, was of 68.04 ISQ; after 24 months, was of 69.48 ISQ, indicating that the implants were stable after 24 months of function. There were no losses of implants during this period. The results were favorable to the evaluated items, the initial and secondary stability remained in normal values, and there were no fractures of the prosthesis, no loosening or fractures of the retention screws, there were no losses of the fifty implants installed, during the period of study of 24 months, showing a viable use of this technique.
9

Efeitos do envelhecimento na altura óssea periimplantar

Pedro, Rejane Eliete Luz January 2013 (has links)
Made available in DSpace on 2013-10-11T13:36:04Z (GMT). No. of bitstreams: 1 000451173-Texto+Completo-0.pdf: 1812168 bytes, checksum: 8a896e7fcd7b000f80719ab791ec8cbc (MD5) Previous issue date: 2013 / Tooth loss is very common in the older people causing a need for a rehabilitative treatment by dental implants. The periimplant bone loss is one of the most important factors for the success of dental implants activated. Ageing, however, is associated with decreased bone metabolism; making can be a risk factor for the loss of these implants. It is known that bone loss can also be influenced by other factors such as gender, bruxism, diabetes, osteoporosis, heart disease, hypothyroidism, alcohol and smoking. This study aimed to monitor radiographic and clinically, for four years, the periimplant bone level from the installation of prostheses placed in dental implants. Were followed 18 patients, 57 patients with dental implants with their respective prosthesis installed, observing the periimplant bone height and systemic diseases present. The loss of periimplant bone height was significantly associated with a history of smoking and to be man, age was inversely associated with bone loss. Factors such as the presence of hypothyroidism, diabetes, hypertension, heart disease and osteoporosis were not associated with bone loss. There were no significant differences in nutritional parameters of patients followed. We conclude that age was a factor associated with height gain and bone that elderly male with a previous history of smoking are associated with loss of periimplant bone height. / A perda dentária é muito comum no idoso fazendo com que exista a necessidade de um tratamento reabilitador por meio de implantes osseointegrados. A perda óssea periimplantar é um dos fatores mais importantes para o sucesso dos implantes osseointegrados ativados. O envelhecimento, entretanto, está associado à diminuição do metabolismo ósseo, fazendo com que possa ser um fator de risco para a perda desses implantes. Sabe-se que a perda óssea pode também ser influenciada por outros fatores como sexo, bruxismo, diabetes, osteoporose, cardiopatias, hipotireoidismo, álcool e tabagismo. O presente trabalho teve como objetivo principal acompanhar radiográfica e clinicamente, durante quatro anos, o nível ósseo periimplantar a partir da instalação de próteses colocadas nos implantes osseointegrados. Foram acompanhados 18 pacientes, portadores de 57 implantes osseointegrados com suas respectivas próteses instalados, observando-se a altura óssea periimplantar e as doenças sistêmicas presentes. A perda da altura óssea periimplantar foi significativamente associada com história prévia de tabagismo e sexo masculino, idade foi inversamente associada à perda de massa óssea. Fatores como presença de hipotireoidismo, diabetes, hipertensão, cardiopatia e osteoporose não foram associados à perda óssea. Não foram observadas diferenças significativas nos parâmetros nutricionais dos pacientes acompanhados. Conclui-se que idade foi um fator associado ao ganho de altura óssea e que idosos do sexo masculino e com história prévia de tabagismo estão associados à perda de altura óssea periimplantar.
10

Análise das estabilidades primária e secundária de implantes curtos unitários instalados na região posterior

Alonso, Fernando Rizzo January 2013 (has links)
Made available in DSpace on 2013-10-11T13:36:08Z (GMT). No. of bitstreams: 1 000450848-Texto+Completo-0.pdf: 1608827 bytes, checksum: 3e7ff522aa354768faac74eab4ba6daa (MD5) Previous issue date: 2013 / Clinical evidences suggest that the stability of dental implants plays an important role on the success of osseointegration. However, there is not sufficient information with respect to the stability of short (6-mm long) implants. Thus, the aims of this study were: 1) to assess clinically and longitudinally the stability of short implants in relation to the bone quality, by means of insertion torque, resonance frequency analysis (RFA) (Osstell®) and damping capacity (PTV) (Periotest®); and 2) to evaluate the correlation among these three techniques. Thirty-nine one-stage implants (Straumann®, SLActive, ø4. 1 x 6-mm long) were placed in the posterior region of the maxilla and the mandible in 18 patients with ages ranging between 25 and 76 years old. The bone quality was identified by the surgeon’s tactile sensitivity at the moment of the perforation and classified according to the Lekholm & Zarb classification (1985) (types I-IV). The insertion torque was measured using the manual wrench (Straumann®) and divided into three groups: <15 N. cm, between 15 and 35 N. cm and, finally, >35 N. cm. The PTV values were measured immediately after the manual torque, at the implant assembler level. For the RFA values, a mean was calculated for the mesio-distal and bucco-lingual measurements. The RFA and PTVs assessments were repeated at the moment of the crown installation (3 months later). The results showed a significant effect of bone quality on the stability values of the implant. Insertion torque values were significantly higher for bone types I-II than for bone types III and IV. Statistical difference was found only for PTV values between bone types I and II compared to bone type IV. For the RFA values, implants placed in types I-II and III presented ISQ significantly higher than implants placed in type IV bone. Besides that, regardless of the type of bone, the mean ISQ values were significantly higher after the osseointegration period (mean=79. 36) than that at the moment of the placement of the implant (mean=68. 29). The results of this study showed that bone quality influences on the values of primary and secondary stability, presenting moderate correlation among the three methods of stability assessment. / Evidências clínicas sugerem que a estabilidade dos implantes exerce um papel importante no sucesso da osseointegração. No entanto, não há informações suficientes a respeito da estabilidade de implantes curtos (6-mm). Diante disso, os objetivos deste estudo foram: 1) avaliar clínica e longitudinalmente a estabilidade de implantes curtos em função da qualidade óssea, através do torque de inserção, análise da frequência de ressonância (RFA) (Osstell®) e capacidade de amortecimento (PTV) (Periotest®); e 2) avaliar a correlação entre as três técnicas. Foram instalados 39 implantes (Straumann, SLActive, 4. 1 x 6 mm), de 1 estágio cirúrgico, na região posterior de maxila e mandíbula, em 18 pacientes com idade entre 25 e 76 anos. A qualidade óssea foi identificada pela sensibilidade tátil do cirurgião no momento da perfuração e classificada de acordo com a classificação de Lekholm & Zarb (1985) (tipos I-IV). O torque de inserção foi medido utilizando um torquímetro manual (Straumann®), e dividido em três grupos: < 15 Ncm, entre 15 e 35 Ncm e >35 Ncm. Os valores PTV foram medidos imediatamente após o torque manual, no montador do implante. Para os valores de RFA foi calculada a média das medidas mésio-distal e vestíbulo-lingual. A avaliação de RFA e PTVs foi repetida no momento da instalação da coroa (3 meses mais tarde). Os resultados mostraram efeito significativo da qualidade óssea nos valores de estabilidade do implante. Os valores do torque de inserção foram significativamente maiores no osso tipo 1-2 do que em osso tipo 3 e 4. Para os valores PTV foi encontrada diferença estatística entre o osso 1-2 e 4. Analisando os valores RFA, os implantes instalados em osso tipo 1-2 e 3 apresentaram ISQ significativamente maior do que os implantes instalados em osso tipo 4. Além disso, independente do tipo de osso, as médias dos valores de ISQ foram significativamente maiores após o período de osseointegração (79,36) do que no momento da instalação do implante (68,29). Os resultados demonstraram que a qualidade óssea influencia nos valores de estabilidade primária e secundária, havendo correlação moderada entre os três métodos de avaliação da estabilidade.

Page generated in 0.0222 seconds