41 |
Análises biomecânica e histológica da interface de implantes osseointegrados submetidos à carga mastigatória imediata em mandíbulas de cãesLenharo, Ariel [UNESP] 03 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-11-03Bitstream added on 2014-06-13T19:22:06Z : No. of bitstreams: 1
lenharo_a_dr_araca_prot.pdf: 1956702 bytes, checksum: 5122f32b3aab14c8107085fded1a11c7 (MD5) / O objetivo deste trabalho foi de estudar em mandíbula de cães, os implantes osseointegrados submetidos a carga imediata considerando a qualidade óssea formada na interface implante-osso, como também medir o contato ósseo da referida interface. Foram utilizados quatro cães que, após as exodontias, receberam três implantes Osseotite 3,75 x 8,5 (Implant Innovations Incorporation) e, após os procedimentos de moldagem e de laboratório para a confecção da prótese em Níquel-Cromo, estas foram instaladas no mesmo dia da instalação dos implantes e submetidas a técnica da carga imediata. Após 240 dias, os implantes mesial e distal foram contra-torqueados medindo-se a resistência do tecido ósseo neoformado. Na seqüência, os animais foram sacrificados (240 dias) e as peças foram processadas para cortes histológicos sem descalcificação. As lâminas obtidas foram coradas pelo azul de toluidina e pelo picro-sirius que foram analisadas pelos microscópios óptico e de luz polarizada, respectivamente. Nas lâminas coradas pelo azul de toluidina, foi possível observar o tecido ósseo neoformado em contato com a superfície dos implantes com ósteons bem definidos. Nestas lâminas foram medidos os perímetros dos implantes para determinar o contato ósseo. As lâminas coradas pelo picro-sirius mostraram deposição de colágeno tipo I. A média de contato ósseo foi de 77,5% e o teste de contratorque aplicado nos implantes apresentou média de 76,13 Ncm. Considerando as limitações deste trabalho, foi possível concluir que a carga imediata em segmentos parcialmente desdentados é uma técnica viável para reabilitação bucal. / The objective of this work was to study the osseointegrated implants undergone immediately loading in dog mandibles, considering the bone quality formed in the implant-bone interface as well as bone contact. Four dogs were used, which after exodontics, received three Osseotite implants 3.75 x 8.5 (Implant Innovations Incorporation) and after the full-arch impression with custom tray and laboratorial procedures for the fabrication of the prosthesis in nickel chrome, this one were installed in the same day as the installation of the implants and was undergone a immediately loading. After 240 days, the mesial and distal implants were reverse torqued, measuring like this, the resistance of the neoformed osseous tissue. Soon after, the animals were sacrificed (240 days) and the samples were processed for histological examination by means of undescalcified sections without decalcification. The histologic specimens attained were stained with toluidine blue and with Picrus Sirius. After microscopical examination of the sections stained by toluidine blue with the optical microscope, it was possible to observe the neoformed osseous tissue and with the presence of well defined osteons. The histologic specimens stained with Picrus Sirius were analysed by polarized light microscope and they showed type I collagen deposition. The mean of osseous contact was of 77.5% between the implant and the bone, and the biomechanical test by means of reverse-torque presented a mean of 76.13 Ncm. Considering the limitations of this work it was possible to conclude that the immediately loading in partially edentulous segments is a viable technique for oral rehabilitation.
|
42 |
Avaliação da incorporação de enxertos ósseos homógenos em humanos: análises histológica e imunoistoquímicaAbla, Marcelo Sabbag [UNESP] 27 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-02-27Bitstream added on 2014-06-13T19:22:10Z : No. of bitstreams: 1
abla_ms_dr_araca.pdf: 493211 bytes, checksum: 7b996be2b8e49d11e130d4903e67a50b (MD5) / O osso homógeno fresco congelado tem sido utilizado no intuito de substituir o osso autógeno. No entanto as suas propriedades de osteoindução e até mesmo osteocondução não estão bem conceituadas na literatura científica. Esse trabalho teve por objetivo avaliar amostras de tecido ósseo homógeno enxertados em humanos através das análises qualitativas histológica e imunoistoquímica. Para tal, dez pacientes previamente selecionados foram submetidos à cirurgia de reconstrução de defeitos ósseos em espessura, usando enxerto ósseo homógeno em bloco fresco congelado estabilizado e fixado por meio de parafusos bicorticais. Após período de integração de seia meses foi realizado procedimento de reabertura para instalação dos implantes osseointegráveis. Neste momento cirúrgico, amostras do enxerto ósseo foram removidas por meio de broca trefina. As amostras foram fixadas em formol 10%, levadas ao processamento para corte descalcificado em parafina e coradas por hematoxilina e eosina. Realizou-se processamento imunoistoquímico para a expressão da enzima Caspase 3. As lâminas foram levadas à microscopia óptica para realização das análises histológica e imunoistoquímica qualitativas. Os resultados mostraram tecido ósseo não vital, com poucas áreas de deposição de osso neoformado sobre a matriz amorfa, presença de infiltrado inflamatório com áreas de osteomielite e imunomarcação expressiva da enzima Caspase 3. Diante da metodologia empregada e dos resultados obtidos concluiu-se que o enxerto homógeno apresentou somente a propriedade biológica de osteocondução durante a fase de incorporação de seis meses / Allogeneic bone has been used fresh frozen in order to replace bone autograft. However, the properties of osteoinduction and osteoconduction are not even well-regarded in the scientific literature. This work aimed to evaluate samples of homogenous bone grafts in humans by qualitative histological analysis and immunohistochemistry. For this ten pre-selected patients underwent surgical reconstruction of bone defects in thick, homogenous bone graft using fresh frozen block stabilized and fixed by bicortical screws. After integration period of six months reopening procedure was performed for installation of osseointegrated implants. At this surgical time bone graft samples were removed by means of drill trephine. The samples were fixed in formalin 10%, taken to court for processing decalcified paraffin, and stained with hematoxylin and eosin. Immunohistochemistry was performed processing for the expression of the enzyme Caspase 3. The slides were brought to light microscopy to carry out the qualitative histology and immunohistochemistry. The results showed non-vital bone tissue, with few areas of deposition of new bone formation on the amorphous matrix, presence of chronic inflammatory infiltrate with areas of osteomyelitis, and immunostaining expressive of the enzyme Caspase 3. Given the methods employed and the results obtained it was concluded that the graft showed only a homogenous biological property of osteoconduction, during the incorporation of six months
|
43 |
Efeito do tratamento de superfície na osseointegração de implantes dentários da liga TI-7,5MoOliveira, João Augusto Guedes de [UNESP] 27 January 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:50Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-01-27Bitstream added on 2014-06-13T19:03:28Z : No. of bitstreams: 1
oliveira_jag_dr_guara.pdf: 2054384 bytes, checksum: 2056494b4d46299584c8acf22e9f6838 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os Biomateriais Metálicos são utilizados para reforçar ou para restaurar a forma e função de tecidos duros. Os implantes e próteses são utilizados para substituir ombros, joelhos, quadris e dentes perdidos entre outros. Nos últimos anos, varias ligas de titânio para aplicações biomédicas foram avaliadas. Neste trabalho, a influência do tratamento de superfície biomimético na osseointegração de implantes dentários da liga Ti-7,5Mo foi avaliada. Os lingotes foram obtidos a partir de titânio e molibdênio utilizando um forno a arco voltaico. Eles foram submetidos a tratamento térmico e conformados a frio em prensa rotativa. Posteriormente foram confeccionados implantes (2,0 mm de diâmetro e 2,5 mm de comprimento) sob medida os quais submetidos ao tratamento de superfície biomimético. Os implantes foram inseridos e analisados histológica realizada após 28 dias. A caracterização microestrutural e mecânica da liga Ti-7,5Mo também foi realizada. Aliga Ti-7,5Mo exibiu baixo modulo de elasticidade e elevada relação resistência/modulo. O uso do tratamento de superfície biomimético promoveu um aumento da osseointegração sobre a superfície dos implantes / Metallic biomaterials are used to reinforce or to restore form and function of hard tissues. Implants and prosthesis are used to replace shoulders, knees, hips and teeth. In the last years, several titanium alloys for biomedical applications have been studied. In the present work, influence of biomimetic surface treatment in osseointegration of Ti-7.5Mo dental implant was evaluated. Ingots were obtained from titanium and molybdenum by using an arc-melting furnace. They were submitted to heat treatment and cold worked by swaging. Then, screw-shaped implants (2.0 mm diameter by 2.5 mm length) were custom made and they were submitted biomimetic surface treatment. Implants were implanted in the rat’s femur and histological analysis was realized after 28 days. Also, microstructural and mechanical properties of Ti-7.5Mo alloy were evaluated. Ti-7.5Mo showed low elasticity modulus and higher ratio strength/modulus. Results obtained suggest that Ti-7.5Mo exhibited excellent bulk properties. The use of the biomimetic surface treatment was able to promote an increase of osseointegration on surface of dental implants
|
44 |
Aplicação do copolímero PLA/PGA adicionado ao fosfato de cálcio ao redor de implantes osseointegráveis instalados sem estabilidade primária em tíbia de coelhos: estudo biomecânico, histométrico e imunoistoquímicoSouza, Francisley Ávila [UNESP] 20 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-12-20Bitstream added on 2014-06-13T20:50:49Z : No. of bitstreams: 1
souza_fa_me_araca.pdf: 9106608 bytes, checksum: bdf2875ef072ff8cbc586f8e3743f207 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Aplicação do copolímero PLA/PGA adicionado ao fosfato de cálcio ao redor de implantes osseointegráveis sem estabilidade primária instalados em tíbia de coelhos. Estudo biomecânico, histométrico e imunoistoquímico. Proposição: O objetivo do presente trabalho foi avaliar comportamento mecânico e biológico do tecido ósseo ao redor de implantes associados ao copolímero ácido polilático/poliglicólico adicionado ao fosfato de cálcio. Materiais e Métodos: Para tal foram usados vinte e cinco coelhos Albinus. Após procedimento cirúrgico os animais foram divididos em 4 períodos, sendo o último período, 60 dias, composto por 10 animais. Os animais tiveram perfurações realizadas com sobrefresagem na porção medial das tíbias direita e esquerda. Na tíbia direita o leito cirúrgico foi preenchido com coágulo sanguíneo e na tíbia esquerda com o copolímero. Em ambos leitos cirúrgicos a instalação dos implantes osseointegráveis ocorreu imediatamente após a fresagem. Nos períodos de 5, 15, 40 e 60 dias os animais foram anestesiados e sofreram eutanásia por meio de perfusão de Formaldeído 4% no ventrículo esquerdo. Nos períodos de 40 e 60 dias realizou-se o torque reverso para remoção dos implantes. As peças dos 5 animais restantes do período de 60 dias foram levadas ao micrótomo Exakt para realização de cortes histológicos com os implantes. Nas demais peças, realizou-se análise imunoistoquímica mediante a utilização dos anticorpos primários contra as proteínas OPG, RANK e RANKL. Resultados: As médias de torque para o grupo controle foram de 10,2 e 5,6 N/cm nos períodos de 40 e 60 dias respectivamente, enquanto para o grupo tratado foram de 7,6 e 7,0 N/cm nos mesmos períodos. Houve um balanço na expressão das proteínas com leve predomínio de RANKL. / Application of PLA/PGA copolymer added to calcium phosphate around osseointegrated implants with no primary stability in rabbits's tibia. A biomecanical, histometric and immunohistochemistry study. Purpose: The aim of the present study was to evaluate the mechanical and biological behaviour of bone tissue formed around the implants associated to copolymer polilactic/poliglicolic acids added to calcium phosphate. Materials and Methods: In the present study, twenty five Albinus rabbits, divided in 4 periods, and the last period, referred to 60 days, was composed by 10 animals. The animals had perfurations performed with osteotomy in the medial portion of right and left tibias. In the right tibia, the surgical bed was filled with blood clot and in the left tibia, the copolymer was used. In the same way in both surgical beds, the osseointegrated implants installation occurred immediately after the osteotomy. In the periods of 5, 15, 40 and 60 days, the animals were anesthetized and were sacrificed by perfusion with 4% formaldehyde, in the left ventricule. In the periods of 40 and 60 days, the reverse torque was performed in order to remove the implants. The pieces of the 5 remaining animals of the 60 days period were processed in the Exakt microtome in order to realize undecalcified histological sections with the implants. In the other pieces, the immunohistochemical analysis was performed in order to detect the presence of the OPG, RANK and RANKL proteins in the bone tissue. Results: The mean of torque for the control group were 10.2 and 5.6 N/cm in the periods of 40 and 60 days respectly, while in the treated group were 7.6 and 7.0 N/cm in the same periods. There was a balance in the expression of the proteins with moderate predominance of RANKL protein. There were no statistically differences between the groups in relation to the linear extension of contact between bone and implant.
|
45 |
Reação tecidual à superfície de titânio tratada pela irradiação laser e hidroxiapatita: análise histomorfométrica em ratosLacoski, Marcelo Kayatt [UNESP] 19 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-12-19Bitstream added on 2014-06-13T19:50:39Z : No. of bitstreams: 1
lacoski_mk_me_araca.pdf: 1635312 bytes, checksum: 4ce00b83ea1a8cdc3971e29bad471ebb (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O tratamento de superfície dos implantes está consolidado como um método capaz de acelerar e melhorar a qualidade da osseointegração, possibilitando técnicas de carregamento precoce dos implantes, diminuindo o tempo de tratamento e o número de insucessos. Desta forma, o objetivo deste estudo foi observar o comportamento celular do tecido subcutâneo de ratos submetidos a implantes de discos de titânio tratados com laser e laser e hidroxiapatita. Para isso, foram utilizados 32 discos de Ti cp implantados no tecido subcutâneo da região dorsal anterior e posterior de 16 animais (Rattus norvegicus albinus, Wistar), divididos em 2 grupos: LA - discos tratados com irradiação laser e LHA - discos tratados com irradiação laser e deposição de hidroxiapatita pelo método biomimético. Na análise histológica pôde-se observar que houve formação conjuntiva na periferia das amostras de titânio, com espessura e presença celular semelhantes, em ambos os grupos. Qualitativamente, o grupo LHA mostrou melhor organização tecidual nos tempos iniciais. Na análise morfométrica houve diferença estatisticamente significante entre os grupos, para a>0,01. / The treatment of surface of the dental implants is consolidated as a method capable to speed up and to improve the quality of the osseointegration, making possible precocious shipment techniques of the implantations, decreasing the time of treatment and the number of failures. Of this form, the aim of this study was to observe the cellular behavior of the subcutaneous tissue submitted to titanium implantations treated with laser and laser with hydroxyapatite. For this, 32 test implants of grade-I commercially pure titanium had been inserted in the connective tissue of the dorsal region of 16 male rats (Rattus norvegicus albinus, Wistar), divided in 2 groups: LA - test implants treated with laser irradiation and LHA - test implants treated with laser irradiation and deposition of hydroxyapatite by the biomimethic method. In the histological analysis it could be observed that it had conjunctive formation in the periphery of the titanium samples, with thickness and similar cellular presence, in both groups. Qualitatively, the group LHA better showed tissue organization in the initial times. There was statistic significant difference between the groups, of the measure of the thickness of the fibrous connective tissue formed in contact with tested implants, for a>0,01.
|
46 |
Análise bidimensional de tensões em implante de nióbio e titânio pelo método dos elementos finitosSouza, Leonardo Rodrigues de 28 June 2006 (has links)
The biomechanical of implants play an important hole in osseointegration. The
finite element method provides a biomechanical study based on numerical
evaluation from mathematical models. In this work, the von Mises stress from
models with niobium implant was compared with titanium implant. A twodimensional
model with screw type implant (4.1 x 10 mm) and cicatrizador (4.5
x 3 mm) in cortical and cancellous bone tissue was used. Force of 100 N was
applied axially at the center surface of the cicatrizador. The materials on this
analysis were assumed to be homogeneous, isotropic and linearly elastic. The
analyzed stress was obtained from previously nodes selected on bone-implant
contact, on implant, cortical and cancellous bone tissue inside. The results
based on compared analysis between models with niobium implant and
titanium showed a similar distribution of stress on implant, cortical and
cancellous bone tissue inside, and bone-implant contact. / A biomecânica dos implantes tem papel fundamental na osseointegração. O
método dos elementos finitos proporciona o estudo da biomecânica baseada
na avaliação numérica de modelos matemáticos. Neste trabalho avaliou-se
comparativamente as tensões de von Mises geradas em modelo com implante
de nióbio e em modelo com implante de titânio. Utilizou-se um modelo
bidimensional com implante cilíndrico rosqueável de 4.1 x 10 mm e cicatrizador
de 4.5 x 3 mm em tecido ósseo cortical e trabecular. Uma carga axial de 100 N
foi aplicada na superfície central do cicatrizador. Os materiais envolvidos nesta
análise foram considerados homogêneos, isotrópicos e linearmente elásticos.
As tensões avaliadas foram obtidas de Nós previamente selecionados no
contato osso-implante, no interior do implante, tecido ósseo cortical e
trabecular. Os resultados baseados na análise comparativa entre os modelos
com implante de nióbio e de titânio demonstraram uma distribuição similar das
tensões no interior do implante, tecido ósseo cortical e trabecular, e no contato
osso-implante. / Mestre em Odontologia
|
47 |
Avaliação histomorfométrica e teste de remoção ao torque do implante dentário com superfície Ossean®: estudo experimental em cãesMarin, Charles 21 February 2008 (has links)
The objective of this study was to compare the biomechanical fixation and
bone-to-implant contact (%BIC) between the OsseanTM, a bioceramic gritblasted
and acid-etched surface versus a dual acid-etched implant surface
(Control) in a beagle dog model. Control and OsseanTM implants (n=3) were
subjected to a series of physico/chemical characterization tools including
scanning electron microscopy (SEM), atomic force microscopy (AFM), and
auger photoelectron spectroscopy (APS). The animal model comprised the
placement of 72 implants along the proximal tibiae of 6 beagle dogs (36 per
surface, 6 per limb, through bilateral sequenced procedures), which remained
for 2 and 4 weeks implantation time. After euthanization, half the specimens
were biomechanically tested (removal torque), and the other half was
nondecalcified processed to ~30 mm thickness slides for histomorphologic and
histomorphometric (%BIC) evaluation. ANOVA at 95% level of confidence and
Tukey post-hoc test was utilized for multiple comparisons. The SEM and AFM
showed that surface microtextures were qualitatively and quantitatively different,
and that the OsseanTM surface presented higher submicrometer Ra and RMS
values compared to Control surfaces. Ca and P was detected at the OsseanTM
surface by APS. Higher degrees of bone organization were observed along the
perimeter of the OsseanTM surface compared to Control, despite the nonsignificant
differences in %BIC between surfaces (p > 0.16). Significantly higher
removal torque was observed for the OsseanTM implants at both implantation
times (p < 0.0001). According to the biomechanical and histomorphologic
results, early wound healing was positively affected by the OsseanTM surface
compared to the dual-acid etched surface. / O objetivo deste estudo foi comparar a fixação biomecânica e o contato ossoimplante
(%COI) entre a superfície Ossean® obtida por jateamento com
partículas biocerâmicas e ataque ácido e o grupo controle (C) de superfície
tratada com duplo ataque ácido em cães beagle. Os implantes controle e
Ossean® (n=3) foram submetidos a testes de caracterização físico/química de
superfície, incluindo microscopia eletrônica de varredura (MEV), microscopia de
força atômica (MFA) e espectroscopia Auger (EA). O estudo animal
compreendeu a colocação de 72 implantes na porção proximal da tíbia (36 por
superfície, 6 por perna, bilateralmente) os quais permaneceram por 2 e 4
semanas in vivo. Após a eutanásia, metade dos espécimes foram destinados
ao teste biomecânico (torque de remoção) e a outra metade foram processadas
para obtençao de lâminas não descalcificadas de aproximadamente 30mm de
espessura onde foram realizadas análises histomorfológica e histomorfométrica
avaliando a %COI. O teste de Tukey para comparações múltiplas e o ANOVA
com 95% de significância foram utilizados para análise estatística. A MEV e
MFA mostraram que as microtexturas foram qualitativa e quantitativamente
diferentes e que a superfície Ossean® apresenta maiores valores nanométricos
de Ra e RMS comparados à superfície do grupo controle. Ca e P foram
detectados na superfície Ossean® através da EA. Maior organização do tecido
ósseo foi observadas ao longo do perímetro da superfície Ossean® em relação
ao grupo controle apesar de não haver diferênça estatística na %COI (p >
0.16). Os valores para o teste de romoção ao torque foram estatistiamente
maiores para os implantes Ossean® em 2 e 4 semanas quando comparados
ao grupo controle (p , 0,0001). Os resultados biomecânicos e histomorfológicos
sugerem que a fase inicial do reparo ósseo é afetada positivamente pela
superfície Ossean® comparada à superfície com duplo ataque ácido. / Mestre em Odontologia
|
48 |
Avaliação in vitro e in vivo do efeito da cobertura de biossilicato aplicado sobre a superfície de titânio durante a osseointegraçãoOliveira, Maiolino Thomaz Fonseca 27 February 2013 (has links)
The aim of this study was to evaluate in vivo, using beagle dog model, the effect of incorporation of biossilicato (highly bioactive glass) on the process of osteogenesis through the bone-implant contact and evaluate in vitro using model cell culture, the influence of the incorporation of biossilicato the rough surface on titanium discs adhesion and cell viability. The implants used for the in vivo study (n = 32) were 10 mm long and 3.5 mm in diameter and having surface treated with double etching. Half of these implants (n = 16) received the incorporation of biossilicato on its surface roughened (Group AA + BIO), while the other half only with rough surfaces (n = 16) was used as control group (group AA). The in vitro assays used commercially pure titanium disks grade IV 8.0 mm diameter by 4.0 mm in height with the same characteristics of implants used in in vivo tests. The assessment from scanning electron microscopy revealed that about 25% of the implant surface was covered by highly bioactive glass so homogeneous. Surface double etching associated biossilicato (AA + BIO) also showed a lower contact angle (α10s = 5.3 ± 1.7 °) compared with the AA surface. The adhesion test used to verify the stability of highly bioactive glass particles embedded on both disks as implants, demonstrate adequate stability, with no disruption of the interface bond between the particle and the surface of titanium. The results of in vitro through cell culture, showed that the percentage of viable cells adhered to the roughened surface covered with biossilicato (AA + BIO) was significantly lower (p <0.001) than the group with surface - AA (P = 0.004). The cell viability test showed that there were no statistically significant differences between groups AA and AA + BIO in any of the periods analyzed. The histomorphological results suggest that the initial repair is not affected by surface AA + BIO compared with the surface only with double etching. / O objetivo deste estudo foi avaliar in vivo, utilizando modelo de implantação em mandíbula de cães, o efeito da incorporação de biossilicato (vidro bioativo) sobre o processo de neosteogênese por meio do contato osso-implante e, avaliar in vitro, utilizando modelo de cultura de células, a influência da incorporação do biossilicato na superfície rugosa de discos de titânio sobre a adesão e viabilidade celular. Os implantes usados para o estudo in vivo (n=32) eram de 10 mm de comprimento e 3,5 mm de diâmetro e conexão cone Morse apresentando superfície tratada com duplo ataque ácido. Metade desses implantes (n=16) recebeu a incorporação de biossilicato em sua superfície rugosa (Grupo AA+BIO), enquanto a outra metade apenas com superfícies rugosa (n=16) foi utilizada como grupo controle (Grupo AA). As análises in vitro utilizaram discos de titânio comercialmente puro grau IV de 8,0 mm de diâmetro por 4,0 mm de altura com as mesmas características dos implantes utilizados nos testes in vivo. A avaliação a partir de microscopia eletrônica de varredura revelou que cerca de aproximadamente 25% da superfície dos implantes foi coberta pelo vidro bioativo de forma homogenea. Superfície com duplo ataque ácido associado ao biossilicato (AA+BIO) também apresentou um menor ângulo de contato (α10s=5,3±1,7º) quando comparada com a superfície AA. Os testes de adesão utilizados para verificar a estabilidade das partículas do vidro altamente bioativo incorporado tanto aos discos quanto aos implantes, demostraram uma adequada estabilidade, não havendo rompimento da interface de união entre a partícula e a superfície de titânio. Os resultados in vitro, por meio de cultura de células, demostraram que a percentagem de células viáveis aderidas à superfície rugosa coberta com biossilicato (AA+BIO) foi significativamente menor (p <0,001) do que o grupo com superfície - AA (P = 0,004). O teste de viabilidade celular demonstrou que não houve diferenças estatisticamente significativas entre os grupos AA e AA+BIO em nenhum dos períodos analisados. Os resultados histomorfológicos sugerem que a fase inicial do reparo não é afetada pela superfície com AA+BIO quando comparada com a superfície apenas com duplo ataque ácido. / Mestre em Odontologia
|
49 |
Análise comparativa da força no limite de escoamento entre um implante de peça única e os de junção hexagonal externa de diâmetros regular e estreito / Análise comparativa da força no limite de escoamento entre um implante de peça única e os de junção hexagonal externa de diâmetros regular e estreitoMundim, Arnaldo Reis 28 February 2008 (has links)
Osseointegrated implants have now been proved to be feasible. However,
several factors still remain to be explained, particularly because of the large
number of manufacturers and models. Although incidence is low, implant
fractures are a clinical reality, and therefore researches are conducted in an
endeavor to reduce their number.
Objective: To test the hypothesis that the reduction in implant diameter
reduces the maximum force required to attain the implant yield limit even when it is
made in one piece. Materials and Methods: To test this hypothesis, three implant
configurations (SIN) (n=10): HER, external hexagonal junction and regular
diameter (3.75mm); HEE, external hexagonal junction and narrow diameter
(3.25mm) and UNI, narrow one-piece (2.35mm) were tested. The maximum force
at yield limit (N) for the implants was evaluated by means of the flexion test, with
force applied perpendicular to the long axis of the implant, at the speed of 0.5
mm/min, in a mechanical test machine. The data were assed by means of the
analysis of variance (ANOVA) and Tukey B tests for parametric groups (P<0.05).
Results: Statistically significant differences were found between UNI and HER and
HEE, and there were no statistically significant differences between the latter two.
Conclusions: The UNI group presented statistically lower maximum resistance at
the yield limit than the groups HEE and HER. / Os implantes osseointegrados são hoje comprovadamente viáveis. No
entanto, alguns fatores ainda devem ser esclarecidos, principalmente pelo
grande número de fabricantes e modelos. A fratura de implantes é uma
realidade clínica, mesmo que de baixa incidência e, portanto suscita pesquisas
no sentido de reluzi-las.
Objetivo: Testar a hipótese de que a redução do diâmetro do implante
reduz a força máxima necessária para atingir o limite de escoamento do
implante de junção hexagonal externa e de diâmetro regular para o de junção
hexagonal externa e diâmetro estreito e deste para o implante de peça única e
diâmetro ainda mais estreito. Materiais e Métodos: Para testar esta hipótese,
três configurações de implantes (SIN) (n=10): HER, junção hexagonal externa e
diâmetro regular (3,75mm); HEE, junção hexagonal externa e diâmetro estreito
(3,25mm) e UNI, peça única estreito (2,35mm) foram testados. A força máxima
no limite de escoamento (N) para os implantes foi avaliada por meio do ensaio
de flexão, com força aplicada perpendicular ao longo eixo do implante, em
máquina de ensaio mecânico na velocidade de 0,5 mm/min. Os dados foram
avaliados por meio de teste de análise de variância (ANOVA) e Tukey B, para
grupos paramétricos (P<0.05). Resultados: Foram encontradas diferenças
estatisticamente significantes entre UNI e HER e HEE, sendo que não houve
diferenças estatisticamente significantes entre os dois últimos. Conclusões: O
grupo UNI apresentou resistência máxima no limite de escoamento
estatisticamente inferior aos grupos HEE e HER. / Mestre em Odontologia
|
50 |
Avaliação da ação do laser (AsGaAl) no torque de remoção de implantes lisos e texturizadosMeyer, Kleber Ricardo Monteiro January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:09Z (GMT). No. of bitstreams: 2
000408029-0.pdf: 5297005 bytes, checksum: b759a1194fe1debd841abcedaff116d7 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This work evaluated the laser (AsGaAl) laser effect by torque removal method, in different healing periods, of smooth and texturized standard model implants, installed in male New Zealand rabbit tibiae, submitted or not to low intensity laser irradiation. For the study, 16 animals, weighing between 3. 5 to 4. 0 kg, with two implants in each tibia, divided in four groups (control and laser for 16 and 30 days of healing) have been used. The laser (AsGaAl) was irradiated with a wave length of 830 nm, continuous mode and power of 100 mW, and the punctual application was 1 J/cm2 in three points and eight applications, with 48 hours intervals, started immediately after the implant installation surgery, in a total of 24 J/cm2. After the healing period, the animals were sacrificed and the tibiae were removed for the implant torque removal measurements with a manual digital torquemeter. The torque removal results for the control groups were: smooth implants, 16 days, 20. 42±3. 06Ncm, and 30 days 27. 42±19. 65Ncm; texturized implants, 16 days, 22. 67±11. 07Ncm, and 30 days 30. 46±16. 06Ncm. for the laser groups, the results were, smooth implants, 16 days, 19. 15±4. 65Ncm, and 30 days, 30. 08±4. 14Ncm; texturized implants, 16 days, 20. 48±6. 72Ncm, and 30 days, 23. 45±10. 40Ncm. The Factorial Analysis of Variance showed that there is a significant difference for this research results if only the time factor is analyzed and it has been observed that, on the 30 days period, the torque removal values are higher than those for the 16 days period. / Este trabalho avaliou o efeito do laser (AsGaAl) através de torque de remoção, em diferentes períodos de cicatrização, de implantes modelo standard lisos e texturizados, colocados em tíbias de coelhos machos da raça Nova Zelândia, submetidos ou não à irradiação com laser de baixa intensidade. Para o estudo foram utilizados 16 animais, pesando entre 3,5 a 4,0 quilos, sendo inseridos dois implantes em cada tíbia, divididos em quatro grupos (controle e laser para 16 e 30 dias de cicatrização). O laser (AsGaAl) foi aplicado com comprimento de onda de 830nm, modo contínuo e potência de 100mW, sendo a aplicação pontual de 1J/cm² em três pontos e oito aplicações, com intervalo de 48 horas, iniciada imediatamente após a cirurgia de colocação dos implantes, perfazendo um total de 24J/cm². Após o período de cicatrização, os animais foram mortos, então, realizada a remoção das tíbias e, em seguida, a medição dos torques para remoção dos implantes com torquímetro elétrico digital de empunhadura manual. Os resultados de torque de remoção obtidos para os grupos controle: Implantes lisos com 16 dias (20,42±3,06Ncm) e 30 dias (27,42±19,65Ncm); implantes texturizados com 16 dias (22,67±11,07Ncm) e 30 dias (30,46±16,06Ncm). Para os grupos laser: Implantes lisos com 16 dias (19,15±4,65Ncm) e 30 dias (30,08±4,14Ncm); implantes texturizados com 16 dias (20,48±6,72Ncm) e 30 dias (23,45±10,40Ncm). A partir dos resultados da Análise de Variância Fatorial, verificou-se que existe diferença significativa para os resultados desta pesquisa sob analise do fator isolado “tempo”, onde observou-se que, no período de 30 dias, os valores do torque de remoção são superiores ao periodo de 16 dias.
|
Page generated in 0.0427 seconds