• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 60
  • 60
  • 24
  • 22
  • 21
  • 21
  • 12
  • 12
  • 11
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Articulator effects of Bennett movement and Bennett angle on cusp inclines

Blankenship, John R. January 1969 (has links)
Dissertação (Mestrado)--School of Dentistry of the University of Michigan, in Denture prosthesis.
2

Estudo comparativo de materiais para modelos analisando o comportamento dimensional e a capacidade de reprodução de detalhes em função de tecnicas de vazamento

Zani, Izo Milton January 1994 (has links)
Tese (doutorado) - Universidade de São Paulo, Faculdade de Odontologia / Made available in DSpace on 2012-10-16T06:55:25Z (GMT). No. of bitstreams: 0
3

Estudo comparativo de quatro materiais e de duas técnicas, simples e dupla, para moldagens funcionais em prótese total

Marchezan, Walter January 2004 (has links)
Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Para isto foi usado como corpo de prova um modelo metálico que simula um maxilar edêntulo, onde foram colocados quatro postes em forma do pirâmide, três truncadas, colocadas na crista do rebordo para medições horizontais, e uma inteira, que servia de referência para uma medição vertical. Com cada material ou técnica foram feitos dez moldes do modelo padrão, que foram vazados com gesso tipo IV. Os sessenta modelos obtidos, bem como o modelo-padrão, foram submetidos às medições das distâncias entre as referências situadas nas pirâmides, três medidas no sentido horizontal e uma no sentido vertical. Isto foi feito numa máquina para medição por coordenadas (tridimensionai), BRT-M507 fabricada pela Mitutoyo, com software Cosmos/Geopak-Win. Os resultados foram submetidos à analise de variância e testes complementares (Post Hoc Tests, de Duncan). A análise dos resultados mostra que quase todas as medidas no plano horizontal foram menores nas réplicas que no padrão, e que na medida vertical a discrepância entre os resultados foi maior, sendo umas medidas maiores e outras menores que no padrão. Estatisticamente, apenas numa das três distâncias avaliadas, Dist. 2, não houve diferença significativa entre os materiais. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo.
4

Estudo comparativo de quatro materiais e de duas técnicas, simples e dupla, para moldagens funcionais em prótese total

Marchezan, Walter January 2004 (has links)
Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Para isto foi usado como corpo de prova um modelo metálico que simula um maxilar edêntulo, onde foram colocados quatro postes em forma do pirâmide, três truncadas, colocadas na crista do rebordo para medições horizontais, e uma inteira, que servia de referência para uma medição vertical. Com cada material ou técnica foram feitos dez moldes do modelo padrão, que foram vazados com gesso tipo IV. Os sessenta modelos obtidos, bem como o modelo-padrão, foram submetidos às medições das distâncias entre as referências situadas nas pirâmides, três medidas no sentido horizontal e uma no sentido vertical. Isto foi feito numa máquina para medição por coordenadas (tridimensionai), BRT-M507 fabricada pela Mitutoyo, com software Cosmos/Geopak-Win. Os resultados foram submetidos à analise de variância e testes complementares (Post Hoc Tests, de Duncan). A análise dos resultados mostra que quase todas as medidas no plano horizontal foram menores nas réplicas que no padrão, e que na medida vertical a discrepância entre os resultados foi maior, sendo umas medidas maiores e outras menores que no padrão. Estatisticamente, apenas numa das três distâncias avaliadas, Dist. 2, não houve diferença significativa entre os materiais. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo.
5

Estudo comparativo de quatro materiais e de duas técnicas, simples e dupla, para moldagens funcionais em prótese total

Marchezan, Walter January 2004 (has links)
Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Para isto foi usado como corpo de prova um modelo metálico que simula um maxilar edêntulo, onde foram colocados quatro postes em forma do pirâmide, três truncadas, colocadas na crista do rebordo para medições horizontais, e uma inteira, que servia de referência para uma medição vertical. Com cada material ou técnica foram feitos dez moldes do modelo padrão, que foram vazados com gesso tipo IV. Os sessenta modelos obtidos, bem como o modelo-padrão, foram submetidos às medições das distâncias entre as referências situadas nas pirâmides, três medidas no sentido horizontal e uma no sentido vertical. Isto foi feito numa máquina para medição por coordenadas (tridimensionai), BRT-M507 fabricada pela Mitutoyo, com software Cosmos/Geopak-Win. Os resultados foram submetidos à analise de variância e testes complementares (Post Hoc Tests, de Duncan). A análise dos resultados mostra que quase todas as medidas no plano horizontal foram menores nas réplicas que no padrão, e que na medida vertical a discrepância entre os resultados foi maior, sendo umas medidas maiores e outras menores que no padrão. Estatisticamente, apenas numa das três distâncias avaliadas, Dist. 2, não houve diferença significativa entre os materiais. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo.
6

Resistência à fratura de próteses parciais fixas de zircônia : efeito da aplicação da cerâmica de cobertura e do jateamento na região gengival dos conectores e pônticos /

Campos, Fernanda. January 2012 (has links)
Orientador: Marco Antonio Bottino / Coorientador: Rodrigo Othávio de Assunção e Souza / Banca: Luiz Felipe Valandro Soares / Banca: Liliana Gressler May / Resumo: Este estudo avaliou o efeito do aplicação da cerâmica de cobertura e do jateamento da infraestrutura (IE) cerâmica na região gengival dos conectores e pônticos com partículas de alumina revestidas por sílica e com partículas alumina na resistência à fratura de próteses fixas. Foram confeccionados 80 pilares em Resina G10 (Accurate Plastics, EUA), sendo 40 com base circular de 8 mm de diâmetro (representando um molar preparado) e 40 com base circular de 6 mm de diâmetro (representando um pré-molar preparado), ambos com características de um preparo para coroa total (altura: 6 mm, angulação: 6°, término em chanfro largo). Esses pilares foram incluídos em resina de poliuretano com a ajuda de um dispositivo metálico que padronizou a distância entre as bases dos pilares em 11 mm, constituindo os modelos. Os modelos foram escaneados e, a partir de blocos de cerâmica a base de zircônia (Vita In-Ceram 2000 YZ Cubes, Vita), foram confeccionadas infraestruturas cerâmicas. As IEs receberam cerâmica de cobertura (Vita VM9) em toda a infraestrutura ou deixando a região gengival de conectores e pônticos exposta. As Próteses parciais fixas (PPFs) foram distribuídas em quatro grupos, de acordo com o fator "tratamento da cerâmica de infraestrutura" (4 níveis): RT - (controle) aplicação da cerâmica envolvendo toda a infraestrutura; RP - região gengival dos conectores e pônticos sem aplicação de cerâmica de cobertura; RPC - RP + jateamento da IE com partículas de alumina revestidas por sílica (30 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm); RPOA - RP + jateamento da IE com partículas alumina (45 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm). As próteses foram cimentadas aos pilares com cimento resinoso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of application of the veneering ceramic and sandblasting of the infrastructure (IE) in the gingival area of the connectors and pontic with alumina particles coated with silica and alumina particles on fracture resistance of fixed prostheses. 80 pillars were made in G10 resin (Accurate Plastics, USA), 40 with circular base diameter of 8 mm (representing a molar prepared) and 40 with circular base diameter of 6 mm (representing a premolar prepared), both with features of a full crown preparation (height 6 mm, angle: 6 ° bevel on the end off). These pillars were embedded in polyurethane resin with the aid of a metal device that standardized the distance between the bases of the pillars on 11 mm, making the models. The models were scanned, and from blocks of zirconia-based ceramic (Vita In-Ceram 2000 YZ Cubes, Vita), ceramics were prepared infrastructure. The ceramic IEs were veneered on the entire IE or leaving the gingival region of the pontic and connectors exposed. The fixed partial dentures (PPFs) were divided into four groups, according to the factor "treatment of infrastructure ceramic"(4 levels): RT - (control) veneering on the entire IE; RP - leaving the gingival region of the pontic and connectors without application of veneering ceramic; RTC - RT + IE sandblasted with alumina particles coated with silica (30 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm); RTOA - RT + IE sandblasted with alumina particles (45 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm). The dentures were cemented to the abutments with resin cement (Panavia F2.0, Kuraray, Japão). After 24 hours, they were subjected to mechanical... (Complete abstract click electronic access below) / Mestre
7

Resistência à fratura de próteses parciais fixas de zircônia: efeito da aplicação da cerâmica de cobertura e do jateamento na região gengival dos conectores e pônticos

Campos, Fernanda [UNESP] 03 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-03Bitstream added on 2014-06-13T19:16:54Z : No. of bitstreams: 1 campos_f_me_sjc.pdf: 579878 bytes, checksum: 4caa0be77bfe4184e9b5b180d03e5a22 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito do aplicação da cerâmica de cobertura e do jateamento da infraestrutura (IE) cerâmica na região gengival dos conectores e pônticos com partículas de alumina revestidas por sílica e com partículas alumina na resistência à fratura de próteses fixas. Foram confeccionados 80 pilares em Resina G10 (Accurate Plastics, EUA), sendo 40 com base circular de 8 mm de diâmetro (representando um molar preparado) e 40 com base circular de 6 mm de diâmetro (representando um pré-molar preparado), ambos com características de um preparo para coroa total (altura: 6 mm, angulação: 6°, término em chanfro largo). Esses pilares foram incluídos em resina de poliuretano com a ajuda de um dispositivo metálico que padronizou a distância entre as bases dos pilares em 11 mm, constituindo os modelos. Os modelos foram escaneados e, a partir de blocos de cerâmica a base de zircônia (Vita In-Ceram 2000 YZ Cubes, Vita), foram confeccionadas infraestruturas cerâmicas. As IEs receberam cerâmica de cobertura (Vita VM9) em toda a infraestrutura ou deixando a região gengival de conectores e pônticos exposta. As Próteses parciais fixas (PPFs) foram distribuídas em quatro grupos, de acordo com o fator “tratamento da cerâmica de infraestrutura” (4 níveis): RT - (controle) aplicação da cerâmica envolvendo toda a infraestrutura; RP - região gengival dos conectores e pônticos sem aplicação de cerâmica de cobertura; RPC - RP + jateamento da IE com partículas de alumina revestidas por sílica (30 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm); RPOA – RP + jateamento da IE com partículas alumina (45 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm). As próteses foram cimentadas aos pilares com cimento resinoso... / This study evaluated the effect of application of the veneering ceramic and sandblasting of the infrastructure (IE) in the gingival area of the connectors and pontic with alumina particles coated with silica and alumina particles on fracture resistance of fixed prostheses. 80 pillars were made in G10 resin (Accurate Plastics, USA), 40 with circular base diameter of 8 mm (representing a molar prepared) and 40 with circular base diameter of 6 mm (representing a premolar prepared), both with features of a full crown preparation (height 6 mm, angle: 6 ° bevel on the end off). These pillars were embedded in polyurethane resin with the aid of a metal device that standardized the distance between the bases of the pillars on 11 mm, making the models. The models were scanned, and from blocks of zirconia-based ceramic (Vita In-Ceram 2000 YZ Cubes, Vita), ceramics were prepared infrastructure. The ceramic IEs were veneered on the entire IE or leaving the gingival region of the pontic and connectors exposed. The fixed partial dentures (PPFs) were divided into four groups, according to the factor “treatment of infrastructure ceramic”(4 levels): RT - (control) veneering on the entire IE; RP - leaving the gingival region of the pontic and connectors without application of veneering ceramic; RTC - RT + IE sandblasted with alumina particles coated with silica (30 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm); RTOA - RT + IE sandblasted with alumina particles (45 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm). The dentures were cemented to the abutments with resin cement (Panavia F2.0, Kuraray, Japão). After 24 hours, they were subjected to mechanical... (Complete abstract click electronic access below)
8

Continuação dos estudos sobre alterações dimensionais, de resistência à tração e de resistência ao dobramento, em corpos de gesso, consequente à sua fratura, seguida de colagem /

Springmann, Werner January 1975 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. / Made available in DSpace on 2012-10-15T19:36:44Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T13:06:37Z : No. of bitstreams: 1 141692.pdf: 4792738 bytes, checksum: af8908cc1e529c5c629472ae7ab3d4b9 (MD5)
9

Relação entre gênero e forma dos incisivos centrais superiores

Brunetto, Juliana 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T08:32:27Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T20:35:46Z : No. of bitstreams: 1 281255.pdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / A seleção do formato mais apropriado para os dentes anteriores superiores é uma etapa importante para obtenção de estética em próteses dentárias. A associação entre forma dentária e gênero tem sido empregada para auxiliar esta seleção, considerando-se que dentes femininos são mais arredondados e que dentes masculinos são mais quadrangulares. Entretanto, tal relação ainda carece de respaldo científico. O objetivo deste estudo foi avaliar, in vivo, possíveis relações entre gênero (masculino e feminino) e os formatos dentários triangular, quadrangular e ovóide. A partir de uma população de estudantes da primeira série do ensino médio da Rede Estadual de Ensino de Florianópolis - Santa Catarina (Brasil), com faixa etária média de 15 anos, foi selecionada uma amostra contendo 433 estudantes. Foram realizadas fotografias do dente incisivo central superior direito de tais indivíduos. O elemento dentário 11 foi padronizado em todas as imagens fotográficas, por meio do sofware Adobe Photoshop, para deixar o longo eixo dentário na posição vertical. O formato geométrico de tais dentes foi determinado por meio de análise gráfica (objetiva) no software AutoCAD. Cada imagem foi classificada em uma das seguintes formas: quadrangular, oval ou triangular. No gênero feminino, os formatos foram 57,73% (n=127) ovóides, 23,54% (n=52) triangulares e 18,64% (n=41) quadrangulares, enquanto no gênero masculino, os formatos foram 54,93% (n=117) ovóides, 36,15% (n=77) triangulares e 8,92% (n=19) quadrangulares (p=0,0010). Em ambos os gêneros, o formato predominante é o ovóide, em proporções semelhantes. Entretanto, o formato triangular é mais frequente no sexo masculino do que no feminino, e o quadrangular mais frequente no sexo feminino do que no masculino.
10

Avaliação da liberdade rotacional de pilares hexágono externo e interno em três estágios

Ribeiro, Cleide Gisele January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-22T13:39:37Z (GMT). No. of bitstreams: 1 233578.pdf: 3361852 bytes, checksum: 88b9ea639fe7af6c5204b70b72dbe1a3 (MD5) / Uma das principais causas do alto índice de afrouxamento de parafusos em prótese sobre implante é a presença de uma maior liberdade rotacional na interface implante/pilar. O objetivo deste estudo foi avaliar a influência dos vários procedimentos laboratoriais sobre a liberdade rotacional e realizar uma análise comparativa entre pilares de hexágono externo e interno. Pilares do tipo UCLA com base metálica em cromo-cobalto foram divididos em : grupo A (pilares de hexágono externo) e grupo B (pilares de hexágono interno). Os valores da liberdade rotacional para os pilares de hexágono externo não variaram significativamente, enquanto que no grupo dos pilares de hexágono interno, os valores aumentaram significativamente após a aplicação do porcelana. Os pilares de hexágono interno apresentaram maior liberdade rotacional que os de hexágono externo.

Page generated in 0.1173 seconds