• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 21
  • 21
  • 21
  • 10
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Resistência à fratura de próteses parciais fixas de zircônia : efeito da aplicação da cerâmica de cobertura e do jateamento na região gengival dos conectores e pônticos /

Campos, Fernanda. January 2012 (has links)
Orientador: Marco Antonio Bottino / Coorientador: Rodrigo Othávio de Assunção e Souza / Banca: Luiz Felipe Valandro Soares / Banca: Liliana Gressler May / Resumo: Este estudo avaliou o efeito do aplicação da cerâmica de cobertura e do jateamento da infraestrutura (IE) cerâmica na região gengival dos conectores e pônticos com partículas de alumina revestidas por sílica e com partículas alumina na resistência à fratura de próteses fixas. Foram confeccionados 80 pilares em Resina G10 (Accurate Plastics, EUA), sendo 40 com base circular de 8 mm de diâmetro (representando um molar preparado) e 40 com base circular de 6 mm de diâmetro (representando um pré-molar preparado), ambos com características de um preparo para coroa total (altura: 6 mm, angulação: 6°, término em chanfro largo). Esses pilares foram incluídos em resina de poliuretano com a ajuda de um dispositivo metálico que padronizou a distância entre as bases dos pilares em 11 mm, constituindo os modelos. Os modelos foram escaneados e, a partir de blocos de cerâmica a base de zircônia (Vita In-Ceram 2000 YZ Cubes, Vita), foram confeccionadas infraestruturas cerâmicas. As IEs receberam cerâmica de cobertura (Vita VM9) em toda a infraestrutura ou deixando a região gengival de conectores e pônticos exposta. As Próteses parciais fixas (PPFs) foram distribuídas em quatro grupos, de acordo com o fator "tratamento da cerâmica de infraestrutura" (4 níveis): RT - (controle) aplicação da cerâmica envolvendo toda a infraestrutura; RP - região gengival dos conectores e pônticos sem aplicação de cerâmica de cobertura; RPC - RP + jateamento da IE com partículas de alumina revestidas por sílica (30 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm); RPOA - RP + jateamento da IE com partículas alumina (45 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm). As próteses foram cimentadas aos pilares com cimento resinoso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of application of the veneering ceramic and sandblasting of the infrastructure (IE) in the gingival area of the connectors and pontic with alumina particles coated with silica and alumina particles on fracture resistance of fixed prostheses. 80 pillars were made in G10 resin (Accurate Plastics, USA), 40 with circular base diameter of 8 mm (representing a molar prepared) and 40 with circular base diameter of 6 mm (representing a premolar prepared), both with features of a full crown preparation (height 6 mm, angle: 6 ° bevel on the end off). These pillars were embedded in polyurethane resin with the aid of a metal device that standardized the distance between the bases of the pillars on 11 mm, making the models. The models were scanned, and from blocks of zirconia-based ceramic (Vita In-Ceram 2000 YZ Cubes, Vita), ceramics were prepared infrastructure. The ceramic IEs were veneered on the entire IE or leaving the gingival region of the pontic and connectors exposed. The fixed partial dentures (PPFs) were divided into four groups, according to the factor "treatment of infrastructure ceramic"(4 levels): RT - (control) veneering on the entire IE; RP - leaving the gingival region of the pontic and connectors without application of veneering ceramic; RTC - RT + IE sandblasted with alumina particles coated with silica (30 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm); RTOA - RT + IE sandblasted with alumina particles (45 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm). The dentures were cemented to the abutments with resin cement (Panavia F2.0, Kuraray, Japão). After 24 hours, they were subjected to mechanical... (Complete abstract click electronic access below) / Mestre
2

Resistência à fratura de próteses parciais fixas de zircônia: efeito da aplicação da cerâmica de cobertura e do jateamento na região gengival dos conectores e pônticos

Campos, Fernanda [UNESP] 03 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-03Bitstream added on 2014-06-13T19:16:54Z : No. of bitstreams: 1 campos_f_me_sjc.pdf: 579878 bytes, checksum: 4caa0be77bfe4184e9b5b180d03e5a22 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito do aplicação da cerâmica de cobertura e do jateamento da infraestrutura (IE) cerâmica na região gengival dos conectores e pônticos com partículas de alumina revestidas por sílica e com partículas alumina na resistência à fratura de próteses fixas. Foram confeccionados 80 pilares em Resina G10 (Accurate Plastics, EUA), sendo 40 com base circular de 8 mm de diâmetro (representando um molar preparado) e 40 com base circular de 6 mm de diâmetro (representando um pré-molar preparado), ambos com características de um preparo para coroa total (altura: 6 mm, angulação: 6°, término em chanfro largo). Esses pilares foram incluídos em resina de poliuretano com a ajuda de um dispositivo metálico que padronizou a distância entre as bases dos pilares em 11 mm, constituindo os modelos. Os modelos foram escaneados e, a partir de blocos de cerâmica a base de zircônia (Vita In-Ceram 2000 YZ Cubes, Vita), foram confeccionadas infraestruturas cerâmicas. As IEs receberam cerâmica de cobertura (Vita VM9) em toda a infraestrutura ou deixando a região gengival de conectores e pônticos exposta. As Próteses parciais fixas (PPFs) foram distribuídas em quatro grupos, de acordo com o fator “tratamento da cerâmica de infraestrutura” (4 níveis): RT - (controle) aplicação da cerâmica envolvendo toda a infraestrutura; RP - região gengival dos conectores e pônticos sem aplicação de cerâmica de cobertura; RPC - RP + jateamento da IE com partículas de alumina revestidas por sílica (30 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm); RPOA – RP + jateamento da IE com partículas alumina (45 μm) na região gengival dos conectores e pônticos (3,5 bar, 20 s, distância = 10 mm). As próteses foram cimentadas aos pilares com cimento resinoso... / This study evaluated the effect of application of the veneering ceramic and sandblasting of the infrastructure (IE) in the gingival area of the connectors and pontic with alumina particles coated with silica and alumina particles on fracture resistance of fixed prostheses. 80 pillars were made in G10 resin (Accurate Plastics, USA), 40 with circular base diameter of 8 mm (representing a molar prepared) and 40 with circular base diameter of 6 mm (representing a premolar prepared), both with features of a full crown preparation (height 6 mm, angle: 6 ° bevel on the end off). These pillars were embedded in polyurethane resin with the aid of a metal device that standardized the distance between the bases of the pillars on 11 mm, making the models. The models were scanned, and from blocks of zirconia-based ceramic (Vita In-Ceram 2000 YZ Cubes, Vita), ceramics were prepared infrastructure. The ceramic IEs were veneered on the entire IE or leaving the gingival region of the pontic and connectors exposed. The fixed partial dentures (PPFs) were divided into four groups, according to the factor “treatment of infrastructure ceramic”(4 levels): RT - (control) veneering on the entire IE; RP - leaving the gingival region of the pontic and connectors without application of veneering ceramic; RTC - RT + IE sandblasted with alumina particles coated with silica (30 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm); RTOA - RT + IE sandblasted with alumina particles (45 μm) in the gingival area of the connectors and pontics (3.5 bar for 20 s, distance = 10 mm). The dentures were cemented to the abutments with resin cement (Panavia F2.0, Kuraray, Japão). After 24 hours, they were subjected to mechanical... (Complete abstract click electronic access below)
3

Influência do tempo de exposição ao meio ambiente, da desinfecção química e da pigmentação sobre a estabilidade dimensional e a manutenção da reprodução de detalhes de silicones nacionais para uso em prótese facial /

Guiotti, Aimée Maria. January 2003 (has links)
Orientador: Marcelo Coelho Goiato / Abstract: The purpose of this study was to analyse the influence of time exposure to the environmental factors, chemical disinfection with 2% chlorhexidine-based solution and two distincts pigments about dimensional changing and maintenance of details of two silicones for use in maxillofacial prosthesis. Thirty specimens were fabricated for each silicone using a matrix, conformed closely to the specifications for nonaqueous, elastomeric dental impression materials established by the Revised American Dental Association n° 19 and the ISO 4823:1984. Specimens were separated in three groups: control (colourless), pigmented with commercial cosmetic (makeup powders) and pigmented with iron oxid. Specimens were analysed in a comparator microscopic (Carl Zeiss) and stereoscopic loupe. The readings were realized after polymerization of the specimens, and after 30 and 60 days, with and 157 without disinfection. The data were submited to the statistic analysis, by the Tukey's Test. The results indicated that all groups presented contraction; the chemical disinfection only changed the dimensional stability of the Silastic cosmetic pigmented group; the dimensional stability of Silastic was affected after 60 days of exposition in all groups. For the Brascoved silicone, the chemical disinfection only didn't have influence about dimensional stability in initial period; the exposition factor had influence about the dimensional stability of Brascoved in all periods and groups. The details were maintained in all specimens for both silicones, independent of the exposition time, of the pigments or disinfection. / Mestre
4

Influência do tempo de exposição ao meio ambiente, da desinfecção química e da pigmentação sobre a estabilidade dimensional e a manutenção da reprodução de detalhes de silicones nacionais para uso em prótese facial

Guiotti, Aimée Maria [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T18:35:15Z : No. of bitstreams: 1 guiotti_am_me_araca.pdf: 769780 bytes, checksum: 381f985ad016f2bce7728744d48fbe14 (MD5) / The purpose of this study was to analyse the influence of time exposure to the environmental factors, chemical disinfection with 2% chlorhexidine-based solution and two distincts pigments about dimensional changing and maintenance of details of two silicones for use in maxillofacial prosthesis. Thirty specimens were fabricated for each silicone using a matrix, conformed closely to the specifications for nonaqueous, elastomeric dental impression materials established by the Revised American Dental Association n° 19 and the ISO 4823:1984. Specimens were separated in three groups: control (colourless), pigmented with commercial cosmetic (makeup powders) and pigmented with iron oxid. Specimens were analysed in a comparator microscopic (Carl Zeiss) and stereoscopic loupe. The readings were realized after polymerization of the specimens, and after 30 and 60 days, with and 157 without disinfection. The data were submited to the statistic analysis, by the Tukey’s Test. The results indicated that all groups presented contraction; the chemical disinfection only changed the dimensional stability of the Silastic cosmetic pigmented group; the dimensional stability of Silastic was affected after 60 days of exposition in all groups. For the Brascoved silicone, the chemical disinfection only didn´t have influence about dimensional stability in initial period; the exposition factor had influence about the dimensional stability of Brascoved in all periods and groups. The details were maintained in all specimens for both silicones, independent of the exposition time, of the pigments or disinfection.
5

Estudo in vitro do comportamento de facetas confeccionadas com artglass e targis quando submetidas à inserção e remoção de grampos circunferenciais em cromo-cobalto

Marchini, Leonardo [UNESP] 15 June 2000 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-06-15Bitstream added on 2015-01-26T13:30:29Z : No. of bitstreams: 1 000126044.pdf: 2751052 bytes, checksum: bf32f58800e85b85750a1a62a30b710d (MD5) / Tendo por objetivo investigar in vitro o comportamento das facetas estéticas confeccionadas com as resinas laboratoriais Artglass e Targis, colocadas em coroas veneer, quando submetidas à inserção e remoção de grampos circunferenciais de cromo-cobalto, foram confeccionadas 24 coroas veneer, sendo doze com faceta estética de Artglass (Heraeus Kulzer) e doze de Targis (Ivoclar Vivadent) e os respectivos grampos de cromo-cobalto. As coroas foram então submetidas a cinco mil ciclos de inserção e remoção dos grampos, em dispositivo destinado para tal. Mediante a aferição da força necessária para a remoção dos grampos das coroas durante os ensaios, da variação da massa dos grampos e coroas e da verificação macroscópica das facetas, foi possível concluir que as facetas estéticas não apresentam variação significativa na força necessária para a remoção dos grampos; apresentam pequena abrasão, observável por inspeção visual e apresentam pequena e variável perda de massa, menor para aquelas confeccionada em Artglass (0,002g em média) e maior para aquelas confeccionadas em Targis (0,006g em média) / Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g)
6

Estudo "in vitro" do comportamento de facetas confeccionadas com artglass e targis quando submetidas à inserção e remoção de grampos circunferenciais em cromo-cobalto /

Marchini, Leonardo. January 2000 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Cícero Eleutério da Silva Filho / Banca: Maria Amélia Maximo de Araujo / Resumo: Tendo por objetivo investigar in vitro o comportamento das facetas estéticas confeccionadas com as resinas laboratoriais Artglass e Targis, colocadas em coroas veneer, quando submetidas à inserção e remoção de grampos circunferenciais de cromo-cobalto, foram confeccionadas 24 coroas veneer, sendo doze com faceta estética de Artglass (Heraeus Kulzer) e doze de Targis (Ivoclar Vivadent) e os respectivos grampos de cromo-cobalto. As coroas foram então submetidas a cinco mil ciclos de inserção e remoção dos grampos, em dispositivo destinado para tal. Mediante a aferição da força necessária para a remoção dos grampos das coroas durante os ensaios, da variação da massa dos grampos e coroas e da verificação macroscópica das facetas, foi possível concluir que as facetas estéticas não apresentam variação significativa na força necessária para a remoção dos grampos; apresentam pequena abrasão, observável por inspeção visual e apresentam pequena e variável perda de massa, menor para aquelas confeccionada em Artglass (0,002g em média) e maior para aquelas confeccionadas em Targis (0,006g em média) / Abstract: Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g) / Mestre
7

Análise in vitro do espaço interno de coroas metálicas em Tilite®, posterior a utilização de alívios sobre troquéis em gesso

Granvilla, Anderson January 2008 (has links)
O presente estudo tem como objetivo principal avaliar qual é o número de camadas de espaçadores de troquéis que apresenta o valor mais próximo da especificação número 8 da ADA (Associação Dentária Americana) para a espessura da camada do cimento de fosfato de zinco, utilizado durante a cimentação de uma coroa metálica total. Foi realizado um estudo experimental “in vitro” com a confecção de 20 coroas totais divididas em quatro grupos: grupo controle (sem a aplicação de espaçadores) e grupos com uma, duas e três camadas de espaçadores para troquéis da marca True Spacer (Talladium do Brasil), mesma fábrica que confecciona a liga metálica utilizada, Tilite®. Para avaliar a espessura do alívio, foi utilizado um filme de silicona de adição determinando o espaço existente entre a parede interna da coroa metálica e o troquel mestre. Após a polimerização do material, as coroas foram removidas do troquel e uma silicona ultraleve de outra coloração foi injetada no interior da coroa com o intuito de garantir a remoção da primeira silicona sem distorção. As amostras de siliconas obtidas foram seccionadas transversalmente para serem escaneadas em alta resolução ao lado de um paquímetro. Posteriormente, as imagens assim obtidas foram levadas ao software Image Tool 3.0 (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA). O procedimento realizado foi a mensuração de pontos para a comparação entre os lados oclusal e a parede axial e apresentou valores médios em micrômetros(μm). Posteriormente, foram submetidos à análise estatística com nível de significância de 5%, através do teste t student, ANOVA e teste de Tukey. Os resultados mostraram diferenças significantes estatisticamente entre as faces oclusais e axiais e, entre os grupos não foram significantes, mas estavam próximos da especificação da ADA, concluindo que a utilização de espaçadores promove alívio suficiente para a cimentação. / The aim of the present study is to evaluate what number of die spacer liners has the value to the specification number 8 of the ADA (American Dental Association) for the thickness of the liner of the zinc phosphate cement utilized during the cementation of a metallic crown. An in vitro experimental study was realized with the confection of 20 total crowns divided in four groups: control group (without layers), and groups with one, two and three layers of True Spacer (Talladium Brazil) die spacers of the same factory of the used metallic league. To evaluate the thickness of the relief was utilized a additional silicona for determinate the space between the internal wall of the metallic crown and the master die. The samples of silicona were cross-sectioned at the middle and took. Subsequently, the images thereby achieved were transferred to the Image Tool 3.0 software (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA).The procedures were the measurement of the points in the oclusal side and axial wall and showed average in micrometers. Therefore, had been submitted to statistics analysis with significant level of 5%, through “t student” test, analysis of variance and Tukey test. The results showed significant statistical differences among occlusal and axial faces and between the groups had not been significant, but they were next to the specification of ADA. Concluding that the use of die spacers promove enough relief for the cementation.
8

Análise in vitro do espaço interno de coroas metálicas em Tilite®, posterior a utilização de alívios sobre troquéis em gesso

Granvilla, Anderson January 2008 (has links)
O presente estudo tem como objetivo principal avaliar qual é o número de camadas de espaçadores de troquéis que apresenta o valor mais próximo da especificação número 8 da ADA (Associação Dentária Americana) para a espessura da camada do cimento de fosfato de zinco, utilizado durante a cimentação de uma coroa metálica total. Foi realizado um estudo experimental “in vitro” com a confecção de 20 coroas totais divididas em quatro grupos: grupo controle (sem a aplicação de espaçadores) e grupos com uma, duas e três camadas de espaçadores para troquéis da marca True Spacer (Talladium do Brasil), mesma fábrica que confecciona a liga metálica utilizada, Tilite®. Para avaliar a espessura do alívio, foi utilizado um filme de silicona de adição determinando o espaço existente entre a parede interna da coroa metálica e o troquel mestre. Após a polimerização do material, as coroas foram removidas do troquel e uma silicona ultraleve de outra coloração foi injetada no interior da coroa com o intuito de garantir a remoção da primeira silicona sem distorção. As amostras de siliconas obtidas foram seccionadas transversalmente para serem escaneadas em alta resolução ao lado de um paquímetro. Posteriormente, as imagens assim obtidas foram levadas ao software Image Tool 3.0 (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA). O procedimento realizado foi a mensuração de pontos para a comparação entre os lados oclusal e a parede axial e apresentou valores médios em micrômetros(μm). Posteriormente, foram submetidos à análise estatística com nível de significância de 5%, através do teste t student, ANOVA e teste de Tukey. Os resultados mostraram diferenças significantes estatisticamente entre as faces oclusais e axiais e, entre os grupos não foram significantes, mas estavam próximos da especificação da ADA, concluindo que a utilização de espaçadores promove alívio suficiente para a cimentação. / The aim of the present study is to evaluate what number of die spacer liners has the value to the specification number 8 of the ADA (American Dental Association) for the thickness of the liner of the zinc phosphate cement utilized during the cementation of a metallic crown. An in vitro experimental study was realized with the confection of 20 total crowns divided in four groups: control group (without layers), and groups with one, two and three layers of True Spacer (Talladium Brazil) die spacers of the same factory of the used metallic league. To evaluate the thickness of the relief was utilized a additional silicona for determinate the space between the internal wall of the metallic crown and the master die. The samples of silicona were cross-sectioned at the middle and took. Subsequently, the images thereby achieved were transferred to the Image Tool 3.0 software (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA).The procedures were the measurement of the points in the oclusal side and axial wall and showed average in micrometers. Therefore, had been submitted to statistics analysis with significant level of 5%, through “t student” test, analysis of variance and Tukey test. The results showed significant statistical differences among occlusal and axial faces and between the groups had not been significant, but they were next to the specification of ADA. Concluding that the use of die spacers promove enough relief for the cementation.
9

Análise in vitro do espaço interno de coroas metálicas em Tilite®, posterior a utilização de alívios sobre troquéis em gesso

Granvilla, Anderson January 2008 (has links)
O presente estudo tem como objetivo principal avaliar qual é o número de camadas de espaçadores de troquéis que apresenta o valor mais próximo da especificação número 8 da ADA (Associação Dentária Americana) para a espessura da camada do cimento de fosfato de zinco, utilizado durante a cimentação de uma coroa metálica total. Foi realizado um estudo experimental “in vitro” com a confecção de 20 coroas totais divididas em quatro grupos: grupo controle (sem a aplicação de espaçadores) e grupos com uma, duas e três camadas de espaçadores para troquéis da marca True Spacer (Talladium do Brasil), mesma fábrica que confecciona a liga metálica utilizada, Tilite®. Para avaliar a espessura do alívio, foi utilizado um filme de silicona de adição determinando o espaço existente entre a parede interna da coroa metálica e o troquel mestre. Após a polimerização do material, as coroas foram removidas do troquel e uma silicona ultraleve de outra coloração foi injetada no interior da coroa com o intuito de garantir a remoção da primeira silicona sem distorção. As amostras de siliconas obtidas foram seccionadas transversalmente para serem escaneadas em alta resolução ao lado de um paquímetro. Posteriormente, as imagens assim obtidas foram levadas ao software Image Tool 3.0 (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA). O procedimento realizado foi a mensuração de pontos para a comparação entre os lados oclusal e a parede axial e apresentou valores médios em micrômetros(μm). Posteriormente, foram submetidos à análise estatística com nível de significância de 5%, através do teste t student, ANOVA e teste de Tukey. Os resultados mostraram diferenças significantes estatisticamente entre as faces oclusais e axiais e, entre os grupos não foram significantes, mas estavam próximos da especificação da ADA, concluindo que a utilização de espaçadores promove alívio suficiente para a cimentação. / The aim of the present study is to evaluate what number of die spacer liners has the value to the specification number 8 of the ADA (American Dental Association) for the thickness of the liner of the zinc phosphate cement utilized during the cementation of a metallic crown. An in vitro experimental study was realized with the confection of 20 total crowns divided in four groups: control group (without layers), and groups with one, two and three layers of True Spacer (Talladium Brazil) die spacers of the same factory of the used metallic league. To evaluate the thickness of the relief was utilized a additional silicona for determinate the space between the internal wall of the metallic crown and the master die. The samples of silicona were cross-sectioned at the middle and took. Subsequently, the images thereby achieved were transferred to the Image Tool 3.0 software (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA).The procedures were the measurement of the points in the oclusal side and axial wall and showed average in micrometers. Therefore, had been submitted to statistics analysis with significant level of 5%, through “t student” test, analysis of variance and Tukey test. The results showed significant statistical differences among occlusal and axial faces and between the groups had not been significant, but they were next to the specification of ADA. Concluding that the use of die spacers promove enough relief for the cementation.
10

Resistência de união e limite de fadiga de nichos confeccionados em resina composta e cimentos à base de ionômero de vidro

Lopes, José Fernando Scarelli [UNESP] 17 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-17Bitstream added on 2014-06-13T18:58:07Z : No. of bitstreams: 1 lopes_jfs_me_arafo.pdf: 1497511 bytes, checksum: 5cff0da20eacc454b65a7066c2aba9f6 (MD5) / O objetivo desta investigação foi determinar a resistência de união e limite de fadiga de nichos confeccionados em resina composta e ionômeros de vidro. Setenta e cinco corpos-de-prova (incisivos mandibulares humanos hígidos) com etiquetas adesivas com perfurações de 3,5mm de diâmetro foram adaptadas sobre a superfície lingual de cada dente. Esta delimitação tinha como objetivo padronizar a área da superfície de esmalte a ser condicionada e, posteriormente, mantida em contato com os materiais restauradores. Para realização dos nichos, matrizes foram realizadas para cada corpo-de-prova onde o material restaurador foi inserido. Os corpos-de-prova foram imersos em água destilada a 37ºC por um período de 30 dias. Para os ensaios de resistência à união, a máquina de testes mecânicos MTS modelo 810 foi calibrada utilizando uma velocidade de deslocamento de 0,5mm/min. Para os testes de limite de fadiga a máquina de testes foi calibrada para submeter cada corpo-de-prova a 10.000 ciclos constantes, com uma freqüência de 5 Hz, amplitude inicial de 0,5 mm e velocidade de rampa inicial de 100N/s. Os valores originais do experimento foram convertidos de N para MPa em função da área da base do nicho (circular) previamente calculada. Os corpos-de-prova após a fratura foram avaliados através de microscopia eletrônica de varredura com aumento de 500 vezes. A médias de resistência à união e limite de fadiga foram comparadas estatisticamente usando o teste de Análise de Variância a um Critério. Nos teste de cisalhamento, a resina composta Z-100 produziu maior valor de resistência de união (12,25 MPa) ao esmalte dentário que o ionômero de vidro convencional Fuji IX (7,21MPa). Não foram observadas diferenças entre os valores do material Fuji II LC (10,29MPa) e os demais materiais. Para todos os materiais, os corpos-de-prova testados por meio de ensaio dinâmico de... / The aim of this study was to determine the bond strength and fatigue limit of rest seats prepared with composite resin and glass ionomer cements. The lingual aspect of seventy-five specimens (intact human mandibular incisors) was delimited by adhesive tags with 3.5-mm diameter perforations. This delimitation aimed at standardizing the area of enamel surface to be etched and later kept in contact with the restorative materials. For preparation of the rest seats, matrixes were obtained for each specimen on which the restorative material was placed. The specimens were immersed in distilled water at 37ºC for a period of 30 days. For the bond strength assays, the mechanical assay machine MTS model 810 was calibrated at a displacement speed of 0.5mm/min. For the fatigue limit tests, the assay machine was calibrated so as to submit each specimen to 10,000 constant cycles, at a 5-Hz frequency with an initial range of 0.5mm and initial sloping speed of 100N/s. The original values of the experiment were converted from N to MPa according to the previously calculated circular area of the base of the rest seat. After fracture, the specimens were evaluated by means of scanning electron microscopy with magnification of 500x. The means of bond strength and fatigue limits were statistically compared through the one-way variance analysis. For the shear resistance test, the composite resin Z-100 yielded a higher value of bond strength (12.25 MPa) to the dental enamel than the conventional glass ionomer cement Fuji IX (7.21MPa). No differences could be found between Fuji II LC (10.29MPa) and the further materials. For all materials, the specimens submitted to dynamic fatigue assay tests yielded lower mean values than those achieved through static shear assays. Regarding the fatigue limit values, all materials presented different behaviors, being that Fuji II LC obtained the higher mean value (6.4MPa), ...(Complete abstract, click electronic access below)

Page generated in 0.1442 seconds