• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 78
  • 10
  • 10
  • 10
  • 10
  • 9
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 78
  • 78
  • 58
  • 58
  • 48
  • 39
  • 29
  • 28
  • 22
  • 15
  • 15
  • 14
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

"Moldagem em prótese parcial fixa com afastamento gengival: estudo histológico comparativo em cães entre a técnica de anel de cobre e godiva e cordão de algodão associado a cloreto de alumínio" / FIXED PARTIAL DENTURE IMPRESSION WITH GINGIVAL DISPLACEMENT: COMPARATIVE HISTOLOGICAL STUDY IN DOGS USING COPPER BAND TECHNIQUE AND STRING IMPREGNATED WITH ALUMINIUM CHLORIDE

Santos, Lydia de Brito 07 May 2002 (has links)
O presente estudo submeteu três cães ao afastamento gengival comparando a técnica de afastamento e moldagem com anel de cobre e godiva de baixa fusão com a técnica de afastamento gengival com cordão de algodão associado a cristais de cloreto de alumínio, e moldagem única com silicona de condensação. O objetivo foi comparar a biocompatibilidade periodontal entre as duas técnicas. Foram obtidas amostras nos períodos de 0 (zero), 3, 7, 14 e 21 dias, as quais foram avaliadas histologicamente, utilizando-se a técnica de coloração hematoxilina e eosina. Como resultado, para todos os métodos testados, as conseqüências histológicas para o periodonto foram consideradas reversíveis. / This study carried out three dogs to gingival displacement comparing the copper band and compound gingival displacement and impression technique with string impregnated in aluminium chloride with gingival displacement technique, and single impression by condensing silicone impression material. The objective was to compare the periodontal biocompability between the two techniques. Blocks specimens including the teeth and the soft tissue were taken immediately, 3, 7, 14 e 21 days, and had histological analysis with stain hematoxilin and eosin. The results showed that all groups had reversible histological consequences.
42

\"Avaliação biomecânica da união dente-implante com diferentes tipos de conectores, por meio do método dos elementos finitos\" / Biomechanical evaluation of implant-tooth union with different types of connectors through the finite element method

Betiol, Ederson Aureo Gonçalves 08 February 2007 (has links)
Este estudo apresenta uma análise, por meio do método não linear dos elementos finitos, de uma prótese parcial fixa de quatro elementos, tendo como pilares um dente natural, localizado na região do primeiro pré-molar inferior, e um implante osseointegrado, localizado na região do segundo molar inferior do mesmo hemiarco. Os modelos deste trabalho, foram criados a partir de radiografias periapicais da região posterior da mandíbula, foram digitalizadas e, posteriormente modificadas, dando origem aos modelos computacionais. Com auxílio do programa Ansys® simulou-se uma carga vertical de 175 N, distribuída ao longo dos retentores e pônticos desta prótese. Foram avaliadas três situações: Modelo 1: prótese fixa com conectores rígidos; Modelo 2: prótese fixa com um conector semi-rígido entre o primeiro pré-molar e o segundo pré-molar; Modelo 3: prótese fixa com um conector semi-rígido entre primeiro molar e segundo molar. Para simular os conectores semirígidos foram usados elementos de contato. A partir dos resultados obtidos, percebeu-se, em todos os modelos, que a região óssea que apresentou maior concentração de tensões foi a próximo da crista óssea mesial do implante, sendo os maiores níveis de tensões encontrados no Modelo 2 e os menores no modelo 3. Observou-se também, com relação ao implante, nos Modelos 1 e 3, altos níveis de tensões na região cervical-mesial, próximo da união retentor-pilar intermediário, já no Modelo 2 percebemos um grande aumento das tensões em toda região cervical. Constatou-se também, com relação aos conectores no Modelo 1, altos níveis de tensões entre os pônticos e entre o pôntico e o retentor sobre implante; no Modelo 2, os maiores níveis de tensões foram encontrados entre os molares e, no Modelo 3 os maiores níveis de tensões foram encontrados no conector semi-rígido. / The aim of this study was to analyze, through a non linear method of finite elements, a fixed partial denture of four elements, having natural teeth as an abutment located in the mandibular first pre-molar region and an osseointegrated implant located in the mandibular second molar region in the same hemi-arc, when a vertical load of 175N was applied and distributed over the retainer and pontic. Three situations were evaluated: Model 1: fixed denture with rigid connectors; Model 2: fixed denture with a semi-rigid connector between the first and second pre-molar; Model 3: fixed denture with a semi-rigid connector between first molar and second molar. From the results obtained from all models, the bone region that presented the highest stress concentration was close to the mesial region in the cortical bone of the implant. The highest stress levels were found in model 2 and the lowest in model 3. As regards the implant, in models 1 and 3, higher stress levels were also observed in the cervicalmesial region, close to the intermediate retainer abutment union. In model 2, a great increase of stress was observed in the entire cervical region. Moreover, with regard to the connectors, in model 1, there were high stress levels between the pontics and between the pontic and implant retainer; in model 2 the highest stress levels were found between the molars; and in model 3, the highest stress levels were found at the semi-rigid connector.
43

"Influência da esplintagem de restaurações protéticas fixas e do número de implantes na distribuição de tensões em mandíbula edentada posterior - análise em elementos finitos" / Influence of the splinting of fixed prosthetic restorations and the number of implants on stress distribution in posterior edentulous mandible – finite element analysis

Silva, Marcelo Gomes da 06 June 2005 (has links)
Em casos de edentulismo parcial, especialmente na ausência de três ou mais dentes posteriores contíguos, não há consenso sobre o número ideal de implantes a serem utilizados nem sobre a conveniência biomecânica de unir ou não as coroas protéticas. O presente estudo teve como finalidade analisar a influência da esplintagem de restaurações protéticas fixas e do número de implantes na distribuição das tensões de von Mises em modelos matemáticos bidimensionais obtidos pelo método de elementos finitos. A partir da imagem digitalizada de uma peça anatômica real, correspondente ao corte sagital da porção posterior esquerda de uma mandíbula, três modelos foram desenvolvidos com as seguintes configurações: (1) coroas protéticas isoladas sobre três implantes; (2) coroas protéticas esplintadas sobre três implantes; e (3) prótese parcial fixa sobre dois implantes, com um pôntico intermediário. Uma carga estática de 300N foi dividida, com igual magnitude, por 15 áreas de aplicação nas superfícies oclusais e angulada em 15º em relação ao longo eixo das restaurações. Os resultados mostraram que o modelo com coroas esplintadas sobre três implantes apresentou os menores valores de tensão, enquanto os maiores valores de tensão foram encontrados no modelo com coroas isoladas. O limite de proporcionalidade dos materiais e estruturas analisadas não foi alcançado nos três modelos, fato que não contra-indicou nenhuma das configurações estudadas. Entretanto, os resultados sugeriram que o planejamento do tratamento deve ser adequado a condições anatômicas, oclusais e biomecânicas específicas. / In cases of partial edentulism, specially in the absence of three or more contiguous posterior teeth, there is not a consensus about the ideal number of implants nor the biomechanical convenience of splinting or not prosthetic crowns. The aim of the present study was to analyze the influence of the splinting of fixed prosthetic restorations and the number of implants on von Mises stress distribution within mathematical two-dimensional models obtained from finite element method. From the digitalized image of a real anatomical piece, corresponding to the sagital slice of the left posterior portion of a mandible, three models were constructed in the following configurations: (1) non-splinted prosthetic crowns on three implants; (2) splinted prosthetic crowns on three implants; and (3) fixed partial denture on two implants, with an intermediate pontic. A 300N static load was divided, in equal magnitude, by 15 application areas on occlusal surfaces and angled in 15º in relation to the long axis of the restorations. The results showed that the model with splinted crowns on three implants presented the lowest stress values, whereas the highest stress values were found in the model with non-splinted crowns. The proportional limit of the analyzed materials and structures was not reached in the three models, fact that did not contraindicate any studied configuration. However, the results suggested that treatment planning may be adequate to anatomical, occlusal and biomechanical specific conditions.
44

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

López, Camilo Andrés Villabona 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.
45

\"Estudo longitudinal da força de mordida em pacientes portadores de próteses parciais fixas sobre implantes osseointegrados: comparação entre áreas dentadas e implantadas\" / Bite force longitudinal study on patients wearing implant-supported partial prothesis

Fileni, Renan Hollanda 22 March 2007 (has links)
A proposta deste estudo foi analisar o desenvolvimento da força máxima de mordida em um grupo de pacientes que recebeu próteses parciais fixas sobre implantes (PPFSI) nas regiões de molares, pré-molares até caninos e incisivos antagonizando com dentes naturais e comparar os resultados obtidos com as áreas dentadas do mesmo grupo de pacientes, durante um período de 64 meses (5,3 anos). As forças de mordida foram medidas em cinco regiões da boca: molares em ambos os lados, pré-molares ou caninos em ambos os lados e incisivos; nas áreas de próteses sobre implantes e também nas áreas de dentes naturais. Para tanto, foi usado um transdutor medidor de força de mordida, que tem como princípio de funcionamento uma célula de força colada a um garfo de mordida, amplamente usado na literatura e sempre operado pelo pesquisador. As medições foram feitas imediatamente após a instalação das próteses, 3, 30 e 64 meses depois. Comparando o desenvolvimento das forças de mordida entre as áreas implantadas e de dentes naturais encontra-se já no primeiro controle, após 3 meses de instalação, um aumento das forças de mordida nas próteses sobre implantes instaladas na região de molares que supera as forças desenvolvidas por dentes naturais na mesma região. Para as próteses instaladas na área de incisivos, ao contrário, não foi registrado aumento estatístico destas forças, havendo uma tendência em permanecerem menores quando comparadas às forças desenvolvidas nas mesmas regiões por dentes naturais. Na região de pré-molares ou caninos não houve aumento estatístico de força nas PPFSI. Quando analisadas as áreas dentadas dos pacientes, não houve mudança estatística de força de mordida em nenhuma das regiões durante todo o experimento. / This study proposal was to analyse the changes on the maximal bite force on a patients sample who had implant-supported partial fixed prosthesis (FPP) installed and the results were compared to the ones obtained from the dentate areas on the same sample. Sixteen patients were followed for sixty-four months (5.3 years) and the bite forces were measured on the mouth regions which the prosthesis were installed (molars and premolars up to canines and incisors regions). This measured occurred on five regions of the mouth: both side molars, pre-molars or canines and incisives; either on the places it had a implant as well as on the natural teeth area. In order to do that, it was used as a measuring device, a largely used apparatus which consisted of a biting fork provided with a strain gauge. The bite forces recordings were made at the time of prosthesis installation, after 3, 30 and 64 months thereafter. It was found a bite force increase in the initial period of 3 months after the prosthesis installation in the area of FPP in the molar regions. In this period the bite forces became higher than in dentate situation in the same region and it manteined on this level until the final of the experiment. Comparing the bite straight development between the implanted areas and the natural teeth areas, we found a bite force increased on the prostheses installed over the molars region that overcome the straight development for natural teeth on the same area. On the other hand, for the prostheses installed on the incisive areas, we had not found a statistical straight increased. Actually, it was a tendency to keep smaller than the straight developed on the same regions by natural teeth. On premolars regions or canines, there was not a straight statistical increased on PPFSI. When we analyze the patients? teeth areas, there was not a statistical bite increase on any of the premolars or canines regions during the entire experiment.
46

Influência do material e técnica de obtenção da infraestrutura na distribuição de tensão de próteses parciais fixas com cantilever / Influence of material and infrastructure obtaining techniques on the stress distribution of cantilever fixed partial dentures

Tonin, Bruna Santos Honório 23 January 2017 (has links)
A passividade da prótese parcial fixa (PPF) sobre implante e a distribuição de tensões ao osso pela infraestrutura, contribuem não só com a osseointegração como também para a sua manutenção. A análise de tensões por fotoelasticidade permite visualizar as magnitudes de tensões e deformações em um modelo confeccionado em resina fotoelástica que possui padrão de concentração e distribuição de tensões semelhantes ao tecido ósseo. Assim, este estudo teve como objetivos comparar a distribuição de tensões de PPFs associadas à cantilever com diferentes materiais de infraestrutura (Co-Cr e Zircônia [Zr]) e métodos de obtenção (CAD/CAM e fundição convencional [monobloco, soldagem a laser e soldagem com TIG]), quando submetidos a diferentes carregamentos oclusais (puntiforme e oclusal distribuído). A partir de um modelo mestre, foram confeccionados 3 modelos fotoelásticos simulando extremidade livre mandibular,com o dente 44 em resina e 2 implantes substituindo os dentes 45 e 46. Os grupos deste estudo incluíram PPFs com infraestruturas obtidas por meio de fundição convencional em monobloco (G1), seccionadas e soldadas a laser (G2) e com TIG (G3) e obtidas por meio do sistema CAD/CAM em Co-Cr (G4) e Zr (G5). As PPFs foram parafusadas sobre os mini pilares e submetidas a carregamento oclusal puntiforme e distribuído (150 N) para avaliação qualitativa das franjas e quantitativa em seis diferentes pontos: apical (P1) e distal (P2) do dente 44, apical (P3) e distal (P4) do implante substituindo o dente 45, apical (P5) e distal (P6) do implante substituindo o dente 46. A análise fotoelástica mostrou maior concentração de tensões na PPF com infraestrutura em monobloco (G1) e menor concentração nas próteses obtidas pelo método CAD/CAM (G4 e G5). Quando submetidos ao carregamento oclusal distribuído, a PPF com infraestrutura em Zr (G5) apresentou um aumento considerável na concentração de tensões, seguida por monobloco (G1) e as que foram soldadas a laser (G2) e TIG (G3). No carregamento pontual sobre o cantilever, a infraestrutura em Co-Cr soldada a TIG (G3) mostrou a maior concentração de tensões. Dentro das limitações deste estudo, concluiu-se que PPFs com infraestruturas obtidas por meio do sistema CAD/CAM foram associadas com menor concentração de tensões e que a secção de infraestruturas metálicas para posterior soldagem pode também ser uma alternativa viável, de acordo com a distribuição de tensões peri-implantes. / The passivity of fixed partial denture (FPD) on implant and the stress distribution to the bone by the infrastructure, contribute not only to osseointegration but also to its maintenance. The stress analysis by photoelasticity allows visualizing the stresses and deformations magnitudes in a model fabricated in photoelastic resin that has a concentration pattern and stress distribution similar to the bone tissue. The aim of this study was to compare the stress distribution of cantilever FDPs with different infrastructure materials (Co-Cr and Zirconia [Zr]) and methods of manufacture (CAD/CAM and conventional casting [one piece, laser welding and welding with TIG]), when submitted to different occlusal loads (punctiform and distributed occlusal). From a master model, 3 photoelastic models were fabricated to simulate the mandibular free end, with the tooth 44 in resin and 2 implants replacing the teeth 45 and 46. The groups of this study included FPDs with infrastructures obtained by conventional casting in one piece (G1), sectioned and laser welded (G2) and TIG (G3) and obtained by the CAD/CAM system in Co-Cr (G4) and Zr (G5). The FDPs were screwed onto the abutments and subjected to punctate and distributed occlusal loading (150 N) for qualitative evaluation of the fringes and quantitative at six different points: apical (P1) and distal (P2) of the tooth 44, apical (P3) and distal (P4) of the implant replacing the tooth 45, apical (P5) and distal (P6) of the implant replacing the tooth 46. The photoelastic analysis showed a higher concentration of stresses in the FPD with one piece infrastructure (G1) and a lower concentration in the prosthesis obtained by CAD/CAM method (G4 and G5). When submitted to distributed occlusal loading, the FPD with Zr infrastructure (G5) showed a considerable increase in stress concentration, followed by one piece (G1) and those that were laser (G2) and TIG (G3) welded. In the cantilever load, the TIG welded Co-Cr infrastructure (G3) showed the highest stress concentration. Within the limitations of this study, it was concluded that FPDs with infrastructures obtained by the CAD/CAM system were associated with lower stress concentrations and that the section of metal infrastructures for later welding may also be a viable alternative, according to the peri-implant stress distribution.
47

Efeito de uma malha de nylon contendo sílica como reforço em próteses parciais fixas em resina composta indireta /

Firmino, Aline Silva. January 2017 (has links)
Orientador: Tarcisio José de Arruda Paes Junior / Banca: Lafayette Nogueira Junior / Banca: Sâmia Carolina Mota Cavalcanti Sacorague / Resumo: O presente estudo teve como objetivo avaliar as características mecânicas de próteses parciais fixas adesivas, confeccionadas em resina composta de uso indireto, reforçadas por uma malha de nylon. Para a confecção da matriz dos espécimes e estudo das tensões nas estruturas, foi realizada análise qualitativa pregressa análise de elementos finitos (FEA). A pesquisa in vitro simula uma prótese parcial fixa de três elementos com inserção entre os primeiros pré-molares e os primeiros molares superiores (n = 60; 10 por grupo). Três dos seis grupos passaram por ciclagem mecânica. Os grupos experimentais foram: G1-prótese fixa convencional; G2 - prótese convencional ciclada; G3 - prótese com reforço da malha posicionada na vertical; G4 - Prótese com reforço da malha posicionada na vertical ciclada; G5 - Prótese com reforço da malha posicionada na horizontal; G6 - Prótese com reforço da malha posicionada na horizontal ciclada.Todos os grupos passaram por ensaio de carga máxima a fratura (EMIC). Os resultados não apresentaram diferença estatística entre os grupos. Concluiu-se que a utilização da malha nylon proporcionou estabilidade, mesmo após a fratura da peça, pois as partes não se separam, além disso, os resultados obtidos in vitro puderam validar os dados in sílico / Abstract: The present study aimed to evaluate the mechanical characteristics of adhesive fixed partial dentures, made from composite resin of indirect use, reinforced by a nylon mesh. A finite element analysis (FEA) was used to compile the specimen matrix and to study the stresses in the structures. In vitro research, simulated a fixed partial denture of three elements with insertion between the first premolars and the major maxillary molars (n = 60; 10 per group). Three of the six groups underwent mechanical cycling. The experimental groups were: G1 - conventional fixed prosthesis; G2 - conventional cyst prosthesis; G3 - prosthesis with reinforcement of the mesh positioned vertically; G4 - Prosthesis with reinforcement of the mesh positioned in the cycled vertical; G5 - Prosthetics with mesh reflux positioned horizontally; G6 - Prosthetics with mesh reinforcement positioned horizontally cycled. All groups underwent maximum fracture loading test (EMIC). The results do not present a statistic between the groups. It was concluded that the use of the nylon mesh provided stability, even after fracture of the part, as parts do not separate, besides, the results obtained in vitro could validate the data in silica / Mestre
48

Análise das tensões geradas por implantes curtos e convencionais reabilitados com próteses fixas unidas e isoladas, por meio do método de correlação de imagem digital / Analysis of the stresses generated by short and conventional implants rehabilitated with splinted and non-splinted fixed prosthesis by digital image correlation method

Raniel Fernandes Peixoto 06 December 2013 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, o uso de implantes curtos associado a próteses fixas metaloplásticas esplintadas pode ser uma alternativa às cirurgias de enxerto ósseo e a melhor transmissão de tensões ao osso adjacente, respectivamente. Dentre os métodos que avaliam a distribuição de tensões em torno dos implantes, a Correlação de Imagem Digital (CID) leva vantagens no que diz respeito à possibilidade de avaliar a distribuição das tensões de forma contínua por meio de imagens obtidas ao longo do tempo, durante carregamento oclusal. Diante disso, este trabalho avaliou qualitativa e quantitativamente o desempenho biomecânico de próteses fixas metaloplásticas parafusadas, unidas e isoladas, sobre implantes de diferentes comprimentos, posicionados na região posterior da mandíbula, por meio do método de CID. A partir de quatro modelos mestres, foram confeccionados quatro modelos em resina de poliuretano F16, simulando extremidade livre mandibular, com o dente 44 em resina (Luxatemp) e os dentes 45, 46 e 47 substituídos por implantes curtos (4 x 5 mm) e/ou convencionais (4 x 11 mm). Os grupos (G) deste estudo foram: G1 (dois implantes convencionais [45 e 46] e um curto [47]), G2 (um implante convencional [45] e dois curtos [46 e 47]), G3 (três implantes curtos) e G4 (três implantes convencionais). Próteses fixas metaloplásticas unidas e isoladas foram parafusadas sobre os intermediários e submetidas a diferentes carregamentos oclusais de 250N: puntiforme (distal do 47 e mesial do 45) e oclusal distribuído. Tensões na direção horizontal (&epsilon;xx) foram calculadas e comparadas qualitativa e quantitativamente pelo software de CID (Davis 8.0, LaVision GmbH). Em geral, houve uma concentração de tensões em maior intensidade nas áreas onde os implantes curtos estavam posicionados. No carregamento puntiforme no segundo molar, houve uma predominância de tensões de compressão e tração nos planejamentos com coroas unidas e isoladas, respectivamente, e as tensões de maior magnitude foram encontradas no G2, G3 e G4 com coroas isoladas (p>0,05), apresentando valores mediados (&mu;S) equivalentes a 396,08, 360,45 e 354,04, respectivamente. No carregamento puntiforme envolvendo o segundo pré-molar, houve predominância de tensões de compressão em todos os planejamentos, com magnitudes mais elevadas nos grupos com coroas unidas (p<0,05). As simulações com carga oclusal distribuída revelaram, também, predominância de tensões de compressão em todos os planejamentos, com maior magnitude nos grupos com coroas unidas, sobretudo no G1 (-464,05±106,43) e G3 (-474,39±179,54) e com diferenças estatisticamente significantes em relação aos demais grupos (p<0,05). Dentro das limitações deste estudo, pode-se concluir que a esplintagem das coroas sobre múltiplos implantes promoveu maior concentração de tensões em torno dos implantes durante os carregamentos puntiforme no segundo pré-molar e oclusal distribuído, reforçando a necessidade de contato interproximal e ajuste oclusal efetivos para promover melhor distribuição das tensões. Adicionalmente, a combinação de implantes curtos e convencionais parece ser uma alternativa viável na reabilitação de áreas edêntulas posteriores com altura óssea reduzida. / In cases of severe vertical bone loss, especially in the posterior region of the mandible, the use of short implants associated with splinted resin-veneered fixed dental prostheses (FDPs) can be an alternative to bone graft surgery and better force transmission to the adjacent bone, respectively. Among the methods to evaluate the stress distribution around the implants, the digital image correlation (DIC) has advantages as regards the possibility of evaluating the stress distribution continuously using images taken over time, during occlusal loading. Thus, this study evaluated qualitatively and quantitatively the biomechanical behavior of splinted and non-splinted resin-veneered FDPs, screw-retained on implants of different lengths positioned in the posterior region of the mandible with the aid of the DIC method. Four F16 polyurethane resin models were fabricated to simulate half of the mandibular arch containing tooth 44 in resin (Luxatemp) and teeth 45, 46 and 47 replaced by short (4 x 5 mm) and/or conventional (4 x 11 mm) implants. Groups (G) of this study were: G1 (two conventional implants [45 and 46] and one short implant [47]), G2 (one conventional implant [45] and two short implants [46 and 47]) G3 (three short implants) and G4 (three conventional implants). Splinted and non-splinted FDPs were screwed to the implant abutment and subjected to different oclusal loads of 250N: punctiform (45 mesial and 47 distal) and balanced occlusal load. Strains in the horizontal direction (&epsilon;xx) were calculated based on displacement and compared qualitatively and quantitatively by the DIC software (Davis 8.0, LaVision Inc.). In general, there was a stress concentration at higher intensity in those areas where short implants were placed. In punctiform load on the second molar, there was a compressive and tensile stresses predominance when splinted and non-splinted crowns were used, respectively, and the stresses of greater magnitude were found in the G2, G3 and G4 with non-splinted crowns (p>0.05), showing median values (&mu;S) equivalent to 396.08, 360.45 and 354.04, respectively. In punctiform load involving the second premolar, there was a compressive stress predominance in all planning with highest magnitudes in groups with splinted crowns (p<0.05). The oclusal load distributed simulations also revealed compressive stresses predominance in all planning, with greater magnitude in groups with splinted crowns, especially in G1 (-464.05 ± 106.43) and G3 (-474.39 ± 179.54), both with statistically significant differences when compared to the other groups (p<0.05). Within the limitations of this study, it can be concluded that splinting multiple adjacent implant supported provided a high stress concentration around the implants during punctiform (45 mesial) and balanced occlusal load, reinforcing the need for effective interproximal contact and oclusal adjustment to promote better stress distribution. Additionally, the combination of short and conventional implants seems to be a viable alternative in the rehabilitation of mandibular free end with reduced bone height.
49

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

Camilo Andrés Villabona López 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.
50

Influência do material e técnica de obtenção da infraestrutura na distribuição de tensão de próteses parciais fixas com cantilever / Influence of material and infrastructure obtaining techniques on the stress distribution of cantilever fixed partial dentures

Bruna Santos Honório Tonin 23 January 2017 (has links)
A passividade da prótese parcial fixa (PPF) sobre implante e a distribuição de tensões ao osso pela infraestrutura, contribuem não só com a osseointegração como também para a sua manutenção. A análise de tensões por fotoelasticidade permite visualizar as magnitudes de tensões e deformações em um modelo confeccionado em resina fotoelástica que possui padrão de concentração e distribuição de tensões semelhantes ao tecido ósseo. Assim, este estudo teve como objetivos comparar a distribuição de tensões de PPFs associadas à cantilever com diferentes materiais de infraestrutura (Co-Cr e Zircônia [Zr]) e métodos de obtenção (CAD/CAM e fundição convencional [monobloco, soldagem a laser e soldagem com TIG]), quando submetidos a diferentes carregamentos oclusais (puntiforme e oclusal distribuído). A partir de um modelo mestre, foram confeccionados 3 modelos fotoelásticos simulando extremidade livre mandibular,com o dente 44 em resina e 2 implantes substituindo os dentes 45 e 46. Os grupos deste estudo incluíram PPFs com infraestruturas obtidas por meio de fundição convencional em monobloco (G1), seccionadas e soldadas a laser (G2) e com TIG (G3) e obtidas por meio do sistema CAD/CAM em Co-Cr (G4) e Zr (G5). As PPFs foram parafusadas sobre os mini pilares e submetidas a carregamento oclusal puntiforme e distribuído (150 N) para avaliação qualitativa das franjas e quantitativa em seis diferentes pontos: apical (P1) e distal (P2) do dente 44, apical (P3) e distal (P4) do implante substituindo o dente 45, apical (P5) e distal (P6) do implante substituindo o dente 46. A análise fotoelástica mostrou maior concentração de tensões na PPF com infraestrutura em monobloco (G1) e menor concentração nas próteses obtidas pelo método CAD/CAM (G4 e G5). Quando submetidos ao carregamento oclusal distribuído, a PPF com infraestrutura em Zr (G5) apresentou um aumento considerável na concentração de tensões, seguida por monobloco (G1) e as que foram soldadas a laser (G2) e TIG (G3). No carregamento pontual sobre o cantilever, a infraestrutura em Co-Cr soldada a TIG (G3) mostrou a maior concentração de tensões. Dentro das limitações deste estudo, concluiu-se que PPFs com infraestruturas obtidas por meio do sistema CAD/CAM foram associadas com menor concentração de tensões e que a secção de infraestruturas metálicas para posterior soldagem pode também ser uma alternativa viável, de acordo com a distribuição de tensões peri-implantes. / The passivity of fixed partial denture (FPD) on implant and the stress distribution to the bone by the infrastructure, contribute not only to osseointegration but also to its maintenance. The stress analysis by photoelasticity allows visualizing the stresses and deformations magnitudes in a model fabricated in photoelastic resin that has a concentration pattern and stress distribution similar to the bone tissue. The aim of this study was to compare the stress distribution of cantilever FDPs with different infrastructure materials (Co-Cr and Zirconia [Zr]) and methods of manufacture (CAD/CAM and conventional casting [one piece, laser welding and welding with TIG]), when submitted to different occlusal loads (punctiform and distributed occlusal). From a master model, 3 photoelastic models were fabricated to simulate the mandibular free end, with the tooth 44 in resin and 2 implants replacing the teeth 45 and 46. The groups of this study included FPDs with infrastructures obtained by conventional casting in one piece (G1), sectioned and laser welded (G2) and TIG (G3) and obtained by the CAD/CAM system in Co-Cr (G4) and Zr (G5). The FDPs were screwed onto the abutments and subjected to punctate and distributed occlusal loading (150 N) for qualitative evaluation of the fringes and quantitative at six different points: apical (P1) and distal (P2) of the tooth 44, apical (P3) and distal (P4) of the implant replacing the tooth 45, apical (P5) and distal (P6) of the implant replacing the tooth 46. The photoelastic analysis showed a higher concentration of stresses in the FPD with one piece infrastructure (G1) and a lower concentration in the prosthesis obtained by CAD/CAM method (G4 and G5). When submitted to distributed occlusal loading, the FPD with Zr infrastructure (G5) showed a considerable increase in stress concentration, followed by one piece (G1) and those that were laser (G2) and TIG (G3) welded. In the cantilever load, the TIG welded Co-Cr infrastructure (G3) showed the highest stress concentration. Within the limitations of this study, it was concluded that FPDs with infrastructures obtained by the CAD/CAM system were associated with lower stress concentrations and that the section of metal infrastructures for later welding may also be a viable alternative, according to the peri-implant stress distribution.

Page generated in 0.0921 seconds