• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • Tagged with
  • 52
  • 52
  • 52
  • 31
  • 31
  • 28
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Desenvolvimento de um paralelizador intra-oral e verificação de sua precisão como método de transferência de planos de guia : Estudo laboratorial /

Borges, Alexandre Luiz Souto. January 2002 (has links)
Orientador: José Eduardo Junho de Araujo / Banca: José Eduardo Junho de Araujo / Banca: Cláudio kliemann / Banca: Eduardo Shigueyuki Uemura / Resumo: O objetivo do presente estudo foi desenvolver um aparelho intra-oral (ParalAB) e verificar sua efetividade como um método de transferência de planos de guia, comparando-o com o delineador de bancada. Foram empregados trinta modelos de gesso, divididos em dois grupos (n=15): no grupo 1 foram preparados planos de guia com delineador de bancada e no grupo 2, com o aparelho intra-oral. Em cada modelo, confeccionou-se planos de guia na face distal dos dentes 13 e 23 e nas faces proximais do dente 17. Cada superfície preparada (A, B, C e D) formou um ângulo em relação ao plano oclusal (a, b, d, q) que foram medidos com uma máquina de medidas de coordenadas tridimensionais. Os valores médios obtidos para o grupo 1 foram a= 91,19 ± 0,48o, b= 90,47 ± 0,66o, d= 90,21 ± 0,76o e q= 90,50 ± 0,73o e para o grupo 2, a= 92,18 ± 0,87o, b= 90,90 ± 0,85o, d= 90,07 ± 0,92o e q= 90,65 ± 0,73o. A aplicação do teste estatístico ANOVA two-way (5%), revelou que os efeitos tipo de aparelho, ângulos e interação apresentaram diferença significante. Ao se aplicar o teste de Tuckey (5%), verificamos que a superfície C, preparada pelo ParalAB foi mais paralela à trajetória de inserção (d= 90,07 ± 0,92o), seguida pela superfície C produzida pelo delineador de bancada (d= 90,21 ± 0,76o), e a mais concorrente foi a superfície A produzida pelo ParalAB (a= 92,18 ± 0,87o), seguida pela superfície A preparada pelo delineador de bancada (a= 91,19 ± 0,48o). As demais superfícies produzidas por ambos os aparelhos ocuparam uma posição intermediária de mesmo comportamento. Ao se aplicar o teste de Levène de comparação de variância, ambos os grupos não apresentaram diferença significante para as inclinações das superfícies por eles produzidas. Podemos concluir que o aparelho ParalAB foi capaz de preparar superfícies paralelas...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to introduce a new intraoral paralleling device (ParalAB) and to verify its efficiency as a transference method of guide planes. Thirty casting models were divided into 2 groups (n=15): in the group 1, guide planes were prepared with a surveyor device and in the group 2, with the ParalAB device. In each model, guide planes were prepared at the distal face of teeth 13 and 23 and at the proximal faces of teeth 17. Each prepared surface (A, B, C and D) formed an angle related to the occlusal plane (a, b, d, q) that were measured with a tridimentional coordinate machine. The mean value for the group 1 were a= 91,19 l 0,48O, b= 90,47 l 0,66O, d= 90,21 l 0,76O and q= 90,50 l 0,73O and for the group 2 were a= 92,18 l 0,87O, b= 90,90 l 0,85O, d= 90,07 l 0,92O and q= 90,65 l 0,73O. The application of ANOVA two-way test (5%) revealed that there were significant difference in all effects: device, angle and interaction. The Tuckey test (5%) revealed that the C surface prepared with ParalAB was more parallel to the path of insertion (d= 90,07 l 0,92O), followed by C surface prepared with the surveyor device (d= 90,21 l 0,76O), and the less parallel was the A surface prepared with ParalAB (a= 92,18 l 0,87o), followed by the A surface prepared with the surveyor device (a= 91,19 l 0,48o). The other surfaces occupied the same intermediary position. The Levene test of variance comparison revealed that the surfaces prepared by devices presented no significant difference. Conclusion: ParalAB was able to prepare parallel surfaces and, although there were significant difference between the two groups, the ParalAB presented a small deviation of the absolute parallelism and can be considered a valid method to transfer the guide plans. / Mestre
32

Avaliação de três métodos de estudo empregados para a análise do preparo do canal radicular /

Leonardi, Denise Piotto. January 2008 (has links)
Orientador: Paulo Sérgio Cerri / Banca: Paulo Tanomaru filho / Banca: Idomeo Bonetti Filho / Banca: Marco Antônio Húngaro Duarte / Banca: Celso Kenji Nishiyama / Resumo: A evolução da endodontia ocorre continuamente de modo que sistemas, técnicas e instrumentos endodônticos têm sido criados e estudados por diversos autores por meio de diferentes métodos analisando seu desempenho. O presente estudo teve como objetivo avaliar aspectos relacionados ao preparo do canal radicular assim como também analisar os métodos de estudo empregados para este fim. Foram empregadas 10 raízes mésio-vestibulares de molares superiores humanos extraídos, as quais foram incluídas em blocos de resina e seccionadas transversalmente nos terços médio e apical. Para a instrumentação foi empregado o sistema Race. A análise do preparo foi feita por meio da Plataforma Radiográfica, do Método de Bramante e do Método Histológico. Foi observado que, diante de uma padronização dos métodos de estudo empregados, é possível obter resultados coerentes entre cada um, mesmo quando se avalia aspectos diferentes do preparo do canal radicular. Pesquisas que avaliam o mesmo aspecto do preparo podem apresentar resultados diferentes e estas diferenças podem estar associadas a variáveis inerentes a cada sistema de avaliação empregado. Em relação ao método de estudo concluiu-se que todos forneceram informações importantes para a análise do preparo do canal radicular, no entanto, não devem ser considerados individualmente. De acordo com o aspecto avaliado, um método pode complementar o outro e, desta forma, atingir resultados fidedignos. Em relação aos aspectos do preparo concluiu-se que o sistema Race mostrou ausência de desvio apical, ação sobre todas as paredes dentinárias, deslocamento do preparo em direção às paredes externa da curvatura e vestibular do canal radicular, ampliação da área nos terços médio e apical, superfícies dentinárias regulares, formato irregular e pequena quantidade de resíduos na luz do canal radicular. / Abstract: There is an usually endodontic evolution thus rotary systems and techniques has been created and evaluated by several authors by different methods. The purpose of this study was to investigate root canal aspects and the methods employed to evaluate the root canal preparation. Mesiobuccal canals of ten maxillary molars extracted human were included in blocks of resin and split across the middle and apical thirds. The root canals were prepared by RaCe rotary files. The prepare analysis was done through the Radiographic Platform, Bramante method and Histological method. It was observed that before the methods standardization it can get consistent results between each one even when assessing different aspects of the root canal preparation. It was concluded that studies that evaluate the same aspect of the preparation may show different results and these are associated with variables inherent in each methodology employee. All the methods supplies important information about root canal preparation. However, it is not should be separately considered. In accord to the evaluated aspect a method can supplies the other one and get reliable results. In relation to the aspects of the preparation it was concluded that the Race system showed apical deviation absence, action on all the walls, displacement to the external curvature walls and vestibular, magnifying of the area, regular surfaces, irregular format and small amount of residues inside the root canal. / Doutor
33

Influência do método de preparo cavitário, alta rotação e laser de Er:YAG, sobre a espessura da camada híbrida de diferentes sistemas adesivos, com diferentes filosofias adesivas / Influence of cavity preparation method, high speed turbine and Er:YAG laser, on hybrid layer thickness of different adhesive systems

Marcos de Oliveira Barceleiro 11 October 2006 (has links)
O objetivo deste estudo foi promover uma comparação entre as espessuras de camadas híbridas formadas entre os sistemas adesivos Scotchbond Multi-Uso Plus, Single Bond 2, Prime & Bond 2.1 e Xeno III, e a superfície dentinária, preparada com dois métodos de preparo cavitário, a ponta diamantada montada em turbina de alta rotação, e o laser de Er:YAG, utilizado com dois parâmetros de energia (200 e 400 mJ) e dois parâmetros de freqüência (4 e 6 Hz). Para a realização deste experimento, foram realizados tratamentos superficiais com os dois métodos descritos em fragmentos de dentina superficial aplainada, retirados de vinte terceiros molares humanos recém-extraídos, seguido de preparo da dentina com os sistemas adesivos. Após a aplicação e fotoativação de uma camada de compósito sobre a dentina preparada, os corpos de prova foram cortados, polidos e preparados para visualização em MEV, meio pelo qual foram realizadas cinco medidas da espessura da camada híbrida formada em cada corpo de prova. Os resultados obtidos foram tratados estatisticamente por ANOVA e teste de Student-Newnan-Keuls, em um nível de significância de 95%, e por Kruskal Wallis e Mann Whitney, também em um nível de significância de 95%, através do programa SPSS for Windows release 5.0. A análise foi realizada levando-se em consideração dois fatores de estudo, a presença ou não de camada híbrida e a espessura da camada híbrida. Em relação ao fator espessura da camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por ANOVA e Student-Newman-Keuls levou a formação de quatro grupos homogêneos, sendo Grupo I (ponta diamantada) > Grupo II (Laser 200 mJ / 4 Hz) = Grupo III (Laser 200 mJ / 6 Hz) > Grupo IV (Laser 400 mJ / 4 Hz) > Grupo V (Laser 400 mJ / 6 Hz). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Em relação ao fator presença de camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por Kruskal Wallis e Mann Whitney levou a formação de três grupos homogêneos (Grupo I _ Grupo II = Grupo III = Grupo IV _ Grupo V). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Quando se realizou o cruzamento tipo de preparo x sistema adesivo, a análise estatística mostrou a formação de sete grupos distintos. Pela análise dos resultados obtidos neste estudo in vitro, foi possível concluir que em dentina preparada com ponta diamantada em alta rotação, os quatro sistemas adesivos testados formaram camadas híbridas de formato regular e presentes de forma constante, com espessura média de 2,90 1,71 m, e em dentina preparada com laser de Er:YAG, os quatro sistemas adesivos testados formaram camadas híbridas de formato irregular e presentes de forma intermitente, com espessura média variando entre 0,41 1,00 m e 2,06 2,49 m. Além disso, concluiu-se que o laser de Er:YAG com os parâmetros testados influencia negativamente a formação da camada híbrida, e que os métodos de preparo cavitário influenciam na espessura da camada híbrida. / The objective of this study was to compare the thickness of the hybrid layer formed using Scotchbond Multipurpose Plus, Single Bond 2, Prime & Bond 2.1 and Xeno III on dentine surface, prepared with a diamond bur in a high speed handpiece, or prepared with an Er:YAG laser, used with two parameters of pulse energy (200 and 400 mJ) and two parameters of frequency (4 and 6 Hz). Flat dentine surfaces obtained from twenty third molars human teeth were treated with the two methods, and then were prepared with the dentine adhesive systems, according to manufacturers instructions. After a layer of composite was applied, specimens were sectioned, flattened, polished and prepared for Scanning Electronic Microscopy observation. Five different measurements of hybrid layer thickness were obtained along the bonded surface in each specimen. Results were statistically analyzed using analysis of variance and Student-Newman-Keuls tests (p ≤ 0.05), and using Kruskal Wallis and Mann Whitney tests (p ≤ 0.05). The statistical analysis was made considering two observations parameters, the presence of the hybrid layer, and its thickness. When analyzing the hybrid layer thickness, and comparing the cavity preparation method, four groups were formed, Group I (diamond bur) > Group II (Laser 200 mJ / 4 Hz) = Group III (Laser 200 mJ / 6 Hz) > Group IV (Laser 400 mJ / 4 Hz) > Group V (Laser 400 mJ / 6 Hz). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the presence of hybrid layer, and comparing the cavity preparation method, three groups were formed (Group I ≠ Group II = Group III = Group IV ≠ Group V). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the hybrid layer thickness, and comparing the cavity preparation method x the dentine adhesive systems, it was found seven different groups. These results showed that the four tested dentine adhesive systems produce a 2.90 1.71 μm hybrid layer in dentine prepared with diamond bur. This hybrid layer was regular and constantly found. In the laser groups, the dentine adhesive systems produced hybrid layers ranging from 0.41 1.00 μm to 2.06 2.49 μm, which were very irregular and were not found constantly. It was also concluded that Er:YAG laser with the parameters used in this experiment, is a negative influence to the hybrid layer formation, and that cavity preparation methods do influence the hybrid layer formation.
34

"Relação entre tensão de contração e grau de conversão em compósitos restauradores" / "Relationship between contraction stress and degree of conversion in dental composites"

Fernanda Calabró Calheiros 06 June 2003 (has links)
RESUMO A tensão de contração desenvolvida durante a polimerização de um compósito aderido às paredes do preparo cavitário pode comprometer a integridade da interface dente/restauração. O objetivo deste trabalho foi verificar a relação entre a tensão de contração e o grau de conversão em compósitos híbridos (Z250 e Tetric Ceram) e microparticulados (A110 e Heliomolar). Para o teste de tensão de contração foram utilizados bastões de vidro de silicato de boro (Pyrex), com 5 mm de diâmetro e 5 cm de altura. Os bastões foram presos às garras de uma máquina de ensaios (modelo 5565, Instron, Canton, MA, EUA) e o compósito foi aplicado às superfícies planas do vidro, as quais passararam por jateamento com óxido de alumínio (250 mm), seguido de silanização e aplicação de adesivo. A distância entre as superfícies dos vidros foi ajustada em 2 mm (Fator C=1,25). O grau de conversão (GC) foi determinado através de espectroscopia fotoacústica no infravermelho (PAS-IR) utilizando-se as razões entre as bandas correspondentes às duplas ligações carbônicas alifáticas (1640 cm -1 ) e aromáticas (1610 cm -1 ). Para cada compósito, tanto no teste de tensão como na análise do grau de conversão, foram constituídos cinco grupos variando-se o tempo de irradiação, a fim de se obter diferentes níveis de densidade de energia (4,8; 13,5; 27,0; 54,0 e 108,0 J/cm 2 ). Foram registrados os valores de tensão máxima e de grau de conversão observados no período de 10 minutos, contados a partir do início da fotoativação. A análise de dados foi feita através de ANOVA de fator duplo e teste de Tukey (a=0,05). Para os valores de tensão de contração, a interação compósito x densidade de energia foi significante. Os valores de tensão de contração para o compósito A110 variaram entre 1,2 e 7,0 MPa, para o Heliomolar entre 0,6 e 6,6 MPa, para o compósito Tetric Ceram entre 1,3 e 8,1 MPa e para o Z250 entre 2,0 e 6,6 MPa. Em geral, valores de tensão maiores foram observados nos níveis de densidade de energia mais elevados. Para o compósito A110 4,8<13,5<27,0<54,0=108,0 J/cm 2 . Para o compósito Heliomolar todos os níveis foram diferentes exceto entre 27,0 e 54,0 J/cm 2 . O compósito Tetric Ceram apresentou 4,8<13,5<27,0<54,0=108,0 J/cm 2 enquanto o compósito Z250 obteve 4,8=13,5<27,0=54,0<108,0 J/cm 2 . O GC foi influenciado pelo compósito (A110: 24% = Heliomolar: 28% = Z250: 32% < Tetric: 39%) e pela densidade de energia. As densidades de energia de 27,0 (33%); 54,0 (35%) e 108,0 (36%) J/cm 2 forneceram graus de conversão estatisticamente semelhantes, o mesmo ocorrendo entre 4,8 (23%) e 13,5 (26%) J/cm 2 e entre 13,5 e 27,0 J/cm 2 . Os resultados mostraram ainda que existe uma relação não-linear entre a tensão de contração e o grau de conversão de compósitos restauradores. Pode-se concluir que densidades de energia elevadas não necessariamente contribuem para um aumento significante no GC, mas podem acentuar o desenvolvimento de tensões de contração. / ABSTRACT The contraction stress developed during polymerization of composites bonded to cavity walls cavity is often associated with marginal gaps and interfacial failure. The aim of this study was to verify the relationship between contraction stress and degree of conversion (DC) in four composites (Z250, A110 – 3M ESPE; Tetric Ceram, Heliomolar – Vivadent). For the contraction stress test, composite (2 mm thick) was bonded between sandblasted and silane-treated glass stubs (Pirex: 5 mm diameter), mounted in a testing machine (model 5565, Instron, Canton, MA, EUA) equipped with a tensilometer to monitor the distance between the rods (C-factor=1.25). DC was determined by Infrared Photoacustic spectrometry (PAS-IR). The ratio between the aliphatic (1640 cm -1 ) and the aromatic (1610 cm -1 ) carbon double-bonds was used for calculating the DC. In both tests, each composite was light-cured for different times in order to provide different energy densities (4.8, 13.5, 27.0, 54.0, 108.0 J/cm 2 ). Maximum contraction stress and DC were measured 10 minutes after the beginning of polymerization. Results were analyzed by two-way ANOVA and Tukey’s test (a=0.05). For contraction stress, the interaction between composite and energy density was significant. Contraction stress values for A110 were between 1,2 and 7,0 MPa, Heliomolar between 0,6 and 6,6 MPa, Tetric Ceram between 1,3 and 8,1 Mpa and Z250 between 2,0 and 6,6 MPa. In general, contraction stress increases with higher energy density levels. For A110, 4.8<13.5<27.0<54.0=108.0 J/cm 2 . Heliomolar showed significant differences between all energy densities, except 27.0 and 54.0 J/cm 2 . Tetric was 4.8<13.5<27.0<54.0=108.0 J/cm 2 and Z250 showed 4.8=13.5<27.0=54.0<108.0 J/cm 2 . DC was influenced by composite (A110: 24%;Heliomolar: 28%, Z250: 32%; Tetric: 39%) and by energy density. The 27.0 (33%), 54.0 (35%) and 108.0 (36%) J/cm 2 energy densities showed similar DC, the same occurring with 4.8 (23%) and 13.5 (26%) J/cm 2 and between 13.5 and 27.0 J/cm 2 .The results showed a non-linear relationship between contraction stress and degree of conversion. It can be concluded that higher energy densities will not necessary contribute to increase DC, but may result in increased contraction stress development.
35

CVDentus® X micromotor na segunda infância: avaliação de aspectos técnicos, comportamentais e da agradabilidade / CVDentUS® x low speed handpiece in the 2nd childhood: evaluation of technical and behavioral aspects and pleasantness

Flávia Patto Carvalho 09 May 2011 (has links)
O tratamento odontológico geralmente envolve ansiedade nos pacientes decorrente da vibração e ruído provocado pelos instrumentos rotatórios. A instrumentação ultrassônica é uma alternativa ao instrumento rotatório convencional, pois proporciona segurança e conforto ao paciente, além de execução simples e fácil. O presente estudo teve como objetivo comparar o uso de brocas convencionais usadas em micromotor (MM) com, pontas diamantadas CVDentus® no equipamento CVDent1000 (CVD) para remoção de tecido cariado e preparo cavitário em crianças, avaliando os aspectos técnicos das pontas, o comportamento das crianças e a agradabilidade dos equipamentos. Participaram 30 crianças de 36 a 71 meses, apresentando pelo menos dois molares decíduos com lesão de cárie oclusal ativa incipiente, ou com lesão questionável, em fossas e fissuras. A amostra foi subdividida em duas fases. Na fase 1, o CVD foi comparado ao MM sem refrigeração e, na fase 2, com o MM sob refrigeração. Este estudo seguiu o modelo split mouth, e o critério de escolha do dente e do equipamento usado na primeira criança foi aleatório, através de sorteios inicialmente e depois, programado para o equipamento. O tratamento foi realizado em uma única sessão, sem anestesia local, sob isolamento relativo, e os dentes restaurados com cimento de ionômero de vidro convencional. Os aspectos técnicos dos sistemas nas fases 1 e 2, avaliados pelo operador, incluíram os parâmetros visualização da área de trabalho (VAT), acesso á cavidade (AC), remoção do tecido cariado (RTC) e ruído e vibração (RV). O comportamento da criança (Cpt) também foi avaliado. As crianças avaliaram a agradabilidade dos equipamentos pela Escala Analógica Visual de Faces de McGrath (1990) Modificada, somente na fase 2. Na fase 1 houve diferença significantemente superior para o CVD nos critérios Cpt (p=0,0431), AC (p=0,0009) e RV (p=0,0006), sendo estes dois últimos também significantes na fase 2, com o mesmo valor de p (Teste de Mann-Whitney). Nos demais critérios, o MM foi superior apenas no RTC, mas não significante. O sistema CVD parece ser uma alternativa promissora. No entanto, são necessários outros estudos para esclarecer aspectos ainda não totalmente entendidos, para que a sua indicação e aplicação em odontopediatria sejam apoiadas por uma evidência científica consistente. / The dental treatment usually involves anxiety in patients due to vibration and noise caused by the rotary instruments. The ultrasonic instrumentation is an alternative to the conventional rotatory instrument, device as it provides security and comfort to the patients, beyond simple and easy execution. The objective of this study was to compare the use of conventional handpiece and drills versus diamond burs CVDentus® system CVDent1000® equipment (CVD) for caries removal and cavity preparation in children, evaluating their clinical performance, behavior children and the pleasantness of the equipment. The sample was composed by 30 children from 36 to 71 months, with at least two primary molars with occlusal incipient active or questionable pits and fissures dental caries. The study was divided into two phases. In the phase one, the CVD was compared to HP without refrigeration, and in the phase two, with HP under refrigeration. This study followed a \"split mouth\" design, and the tooth and the equipment used for the first child were randomly selected by lottery at the beginning, then the selection was programmed for the equipment. The treatment was performed in a single session, without local anesthesia, under rubber dam isolation, and the teeth were restored with conventional glass ionomer cement. The clinical performance of the systems in the two phases was evaluated by the operator, and included the parameters working area view (WAV), access to the cavity (AC), removal of carious tissue (RCT) and noise and vibration (NV). The child\'s behavior (B) was also evaluated. Children rated the pleasantness of the equipment by the modified VAS Faces of McGrath (1990), only in phase 2. There was a higher and significant difference for CVD in the criteria B (p = 0.0431), AC (p = 0.0009) and NV (p = 0.0006). These last two criteria were also significant in phase 2, with the same p value (Mann-Whitney). For the other criteria, the MM was only superior in RCT, but not significant. The CVDentus® system seems to be a promising alternative. However, additional studies are necessary to clarify aspects that were not completely understood, so that its indication and application in pediatric dentistry being supported by consistent scientific evidence.
36

Influence of enamel acid-etching on mechanical properties and nanoleakage of resin composite restorations after thermomechanical aging = Influência do condicionamento ácido do ângulo cavosuperficial nas propriedades mecânicas e nanoinfiltração de restaurações após envelhecimento termomecânico / Influência do condicionamento ácido do ângulo cavosuperficial nas propriedades mecânicas e nanoinfiltração de restaurações após envelhecimento termomecânico

Coppini, Erick Kamiya, 1989- 24 August 2018 (has links)
Orientador: Luís Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T07:41:05Z (GMT). No. of bitstreams: 1 Coppini_ErickKamiya_M.pdf: 3349153 bytes, checksum: e0323d6512c30cee2e8ea17128a4c6e6 (MD5) Previous issue date: 2013 / Resumo: The aim of this study was to evaluate the cavosuperficial enamel acid-etching influence in class I cavities, filled with composites on microtensile bond strength, Knoop microhardness and nanoleakage after thermomechanic ageing. It was selected 76 sound molar splitted on: 32 teeth to microtensile test (n=8); 32 teeth to Knoop microhardness (n=8); and 12 teeth (n=3) to nanoleakage analysis. The cavities were prepared on a standard cavity preparation machine. Half of the teeth had the cavosuperficial enamel etched with 35% phosphoric acid and restored with a Silorane restorative system or a Methacrylate restorative system. After the conclusion of the restoration procedures, the teeth were taken to a thermomechanic cycling machine where the artificial ageing was performed with 200.000 mechanical cycles with an 80 N load in a 2HZ frequency and thermocycling by filling the chambers for 30 seconds and 15 seconds drainage with the temperatures varying between 5ºC and 55ºC. The samples were submitted to the microtensile bond strength test, Knoop microhardness and nanoleakage evaluation. To statistical analysis it was performed the ANOVA two-way and Tuckey test (p ? 0,05). The group restored with methacrylate without acid-etching showed the lowest values of microtensile bond strength and it was statistically different to the other groups that have no difference between them. The methacrylate composite presented statistically higher values on Knoop microhardness compared to silorane composite. The nanoleakage analysis showed low infiltration to silorane restorative system and moderate infiltration to the methacrylate restorative system. The methacrylate group restored without enamel acid-etching showed the formation of Water Trees. It can be concluded that the acid-etching improved the bond strength to the methacylate system. The methacrylate composite has bigger Knoop microhardness than silorane composite. The methacrylate restorative system showed moderate infiltration on nanoleakage analysis / Abstract: The aim of this study was to evaluate the cavosuperficial enamel acid-etching influence in class I cavities, filled with composites on microtensile bond strength, Knoop microhardness and nanoleakage after thermomechanic ageing. It was selected 76 sound molar splitted on: 32 teeth to microtensile test (n=8); 32 teeth to Knoop microhardness (n=8); and 12 teeth (n=3) to nanoleakage analysis. The cavities were prepared on a standard cavity preparation machine. Half of the teeth had the cavosuperficial enamel etched with 35% phosphoric acid and restored with a Silorane restorative system or a Methacrylate restorative system. After the conclusion of the restoration procedures, the teeth were taken to a thermomechanic cycling machine where the artificial ageing was performed with 200.000 mechanical cycles with an 80 N load in a 2HZ frequency and thermocycling by filling the chambers for 30 seconds and 15 seconds drainage with the temperatures varying between 5ºC and 55ºC. The samples were submitted to the microtensile bond strength test, Knoop microhardness and nanoleakage evaluation. To statistical analysis it was performed the ANOVA two-way and Tuckey test (p ? 0,05). The group restored with methacrylate without acid-etching showed the lowest values of microtensile bond strength and it was statistically different to the other groups that have no difference between them. The methacrylate composite presented statistically higher values on Knoop microhardness compared to silorane composite. The nanoleakage analysis showed low infiltration to silorane restorative system and moderate infiltration to the methacrylate restorative system. The methacrylate group restored without enamel acid-etching showed the formation of Water Trees. It can be concluded that the acid-etching improved the bond strength to the methacylate system. The methacrylate composite has bigger Knoop microhardness than silorane composite. The methacrylate restorative system showed moderate infiltration on nanoleakage analysis / Mestrado / Dentística / Mestre em Clínica Odontológica
37

Comparação da resistência de união de diferentes superfícies dentinárias na obtenção dos espécimes para microtração / Effect of different dentin surfaces on the microtensile bond strength values

Agulhari, Maria Angelica Silverio 18 May 2015 (has links)
Com intuito de aumentar a longevidade das restaurações, diversos sistemas adesivos são disponibilizados no mercado e, com isso, muitos estudos são conduzidos, dentre eles, a resistência de união desses sistemas. A maioria dos trabalhos utiliza o teste de microtração. Este teste permite a avaliação de diferentes superfícies, gerando variedade nos resultados obtidos e dificultando a comparação de dados. Este estudo teve como objetivo comparar os valores de resistência de união para as diferentes superfícies de dentina utilizadas em testes de microtração (dentina planificada e dentina de paredes cavitárias, com túbulos dentinários dispostos predominantemente paralelos ou perpendiculares à interface adesiva). Foram utilizados 80 terceiros molares humanos, divididos aleatoriamente em 4 grupos e 2 subgrupos, de acordo com a superfície dentinária de obtenção dos espécimes e do sistema adesivo utilizado: G1 (PO) planificação da face oclusal (baixo fator C); G2 (PV) planificação da face vestibular (baixo fator C); G3 (CP) face pulpar de preparo cavitário oclusal (alto fator C); G4 (CV) face vestibular de preparo oclusal (alto fator C). Dois diferentes sistemas adesivos foram utilizados: convencional de 3 passos Adper Scotchbond Multi-Purpose (3M ESPE) e o autocondicionante de 2 passos Clearfil SE Bond (kuraray), resultando em 8 subgrupos (n=10): POSMp; POCf; PVSMp; PVCf; CPSMp; CPCf; CVSMp; CVCf. A resina composta (Filtek Z250 A3) foi inserida em dois incrementos horizontais. Após 48 horas, os dentes foram seccionados com disco diamantado para a obtenção dos palitos com área de seção transversal de ±0,8mm. Uma fatia de cada subgrupo foi separada para análise em MEV. Os espécimes foram fixados ao dispositivo de microtração tipo Bencor multi T adaptado à máquina de ensaios universal Instron. Uma força de tração com velocidade de 0,5 mm/min utilizando uma célula de carga de 500N foi aplicada. As superfícies fraturadas foram analisadas em Esteromicroscópio LeicaMZ6 para identificar e classificar o tipo de fratura. Os resultados foram submetidos ao teste ANOVA a 2 critérios e ao teste de Tukey com nível de significância de 5%, para cada tipo de adesivo. Os valores médios (MPa±dp) foram: POSMp: 44.51±9.28; PVSMp: 56.75±6.58; CPSMp: 27.88±5.71;CVSMp: 32.54±6.11; POCf: 48.34±8.09; PVCf: 52.51±10.18; CPCf: 23.06±5.93; CVCf: 31.35±4.03. Houve diferença estatisticamente significante para o tipo de preparo (p<0.01 para ambos adesivos) e para a orientação dos túbulos dentinários (p<0,001 para o Scotchbond Multipurpose e p=0.012 para o Clearfil SE Bond).. Concluiu-se, portanto, que os espécimes obtidos a partir de cavidades apresentaram redução nos valores de resistência de união e a orientação paralela dos túbulos em relação à interface adesiva aumentou os valores de resistência de união à microtação. / Microtensile test is usually used to evaluate bond strength values and can be affected by several factors resulting in a diversity of values which makes it difficult to compare data. Flat surfaces dentin are used in most studies. However, specimens from a tooth cavity preparation can be a more realistic model. The aim of this study was to compare &#x3BC;TBS values of dentin flat surfaces (low C factor) and dentin from cavity preparations (high C fator) and its relation with the direction of the dentin tubules. Eighty extracted caries-free human molars were assigned into 4 groups: OF (occlusal flat surface specimens low C factor); BF (buccal flat surface specimens low C factor); PC (pulp surface of cavity preparations specimens high C factor) and BC (buccal surface of cavity preparations specimens high C factor). Each group was divided into 2 subgroups according to the adhesive system Adper Scotchbond Multi-Purpose (3M ESPE) or Clearfil SE Bond (Kuraray), resulting in 8 groups (n=10): OFSMp; OFCf; BFSMp; BFCf; PCSMp; PCCf; BCSMp and BCCf. Two horizontal increments of Filtek Z250 resin were used to restore the teeth. After 48 hours storage, the specimens were sectioned into 0.8 mm beams with diamond disc for microtensile test and submitted to a tensile force in a Universal Testing Machine (Instron) at 0.5mm/min. One slice of each subgroup was randomly selected for MEV. Mean values (MPa±sd) were OFSMp: 44.51±9.28; BFSMp: 56.75±6.58; PCSMp: 27.88±5.71; BCSMp: 32.54±6.11; OFCf: 48.34±8.09; BFCf: 52.51±10.18; PCCf: 23.06±5.93; BCCf: 31.35±4.03. Data were statistically analyzed by two-way ANOVA and Tukeys test (p<0.05) for each adhesive. The adhesive failures were predominant in all groups. It can be concluded that the microtensile bond strength was influenced by the type of dentin surface and tubules orientation. The specimens obtained from cavity preparations showed reduced &#x3BC;TBS (p<0.01). Parallel tubules orientation showed a statistically significant increase of &#x3BC;TBS (p<0.001 for Scotchbond Multipurpose and p=0.012 for Clearfil SE Bond).
38

Efeito de retenções adicionais na microinfiltração e formação de microfendas na margem gengival de restaurações de classe II extensas, feitas com resina composta: avaliação antes e após ciclagem mecânica / Effect of additional retention in microleakage and gap formation in gingival margin of class II resin restorations: evaluation before and after mechanical cycling

Ishikiriama, Sérgio Kiyoshi 11 October 2006 (has links)
Este estudo laboratorial comparou a microinfiltração marginal e formação de microfendas em restaurações de classe II extensas, feitas com resina composta com margens situadas em dentina/cemento, utilizando diferentes tipos de retenções adicionais na caixa proximal. Cavidades padronizadas MOD extensas foram confeccionadas em 40 terceiros molares humanos, os quais foram divididos em 4 grupos de acordo com a retenção adicional confeccionada na caixa proximal: (G1) sem retenção adicional - controle; (G2) canaletas verticais nas paredes vestibular e lingual; (G3) orifícios na parede gengival e (G4) canaleta horizontal na parede gengival. Todos os grupos foram restaurados pela técnica incremental, com sistema adesivo (Prime Bond NT - Dentsply) e resina composta híbrida (QuiXfil - Dentsply). Todos os dentes restaurados foram imersos em corante com aplicação simultânea de cargas contínuas (forças variando entre 1kg e 17kg). Moldagens da margem gengival restaurada foram realizadas antes e após a ciclagem mecânica e réplicas de resina epóxica foram obtidas e analisadas em microscópio eletrônica de varredura para avaliação das microfendas marginais. Após as moldagens, todos os dentes foram seccionados para análise da microinfiltração marginal. Todas as micrografias da margem gengival e imagens dos cortes seccionados foram analisados quantitativamente no programa Image Tools (UTHSCSA). Os valores para microinfiltração foram submetidos a análise de variância e teste de Tukey (p< ou = 0,05). As extensões das fendas antes e após a ciclagem mecânica foram comparadas pelo teste \'t\'\' de Student. Também foi realizada uma análise de correlação entre a extensão das microfendas e microinfiltração marginal (teste de correlação de Pearson). Todos os grupos com retenção adicional (G2=11,59, G3=7,11 e G4=1,57) apresentaram microfendas significantemente menos extensas que o grupo controle sem retenção (G1=42,43) (p< ou = 0.05). Resultados similares foram obtidos para a análise de microinfiltração (G1= 82,84; G2=64,73; G3=45,42; G4=3,09), com diferenças significantes entre todos os grupos (p< ou = 0,05). Todos os grupos apresentaram aumento na extensão das fendas após a aplicação de cargas contínuas, com exceção do grupo da canaleta horizontal (grupo 4). Este tipo de retenção adicional apresentou os melhores resultados em ambos os parâmetros. Os resultados mostraram uma tendência a correlação entre os dois parâmetros estudados. Segundo os resultados, as retenções adicionais podem melhorar a adaptação marginal e minimizar a microinfiltração em restaurações de classe II extensas, feitas com resina composta. / This in vitro study compared marginal leakage and gap formation in resin composite class II cavities with gingival margin in cementum, using 3 different additional retention in proximal box. Standardized large MOD cavities, with gingival margins in cementum, were prepared in forty extracted human molars and divided into 4 groups according to the retention in proximal box: (G1) no retention; (G2) vertical grooves in buccal and lingual walls; (G3) pins in gingival wall; and (G4) horizontal grooves in gingival wall. All groups were restored with the incremental technique, using hybrid resin composite (QuiXfil - Dentsply) and bonding agent (Prime Bond NT - Dentsply). All restored teeth were immersed in dye with simultaneous mechanical loading (alternated loading between 1kg and 17kg). Impressions of gingival margins were made before and after mechanical loading and epoxic resin replicas were evaluated in scanning electron microscope for gap formation. After the impressions, all teeth were seccioned for microleakage evaluation. All SEM photomicrographs and seccioned teeth images were analysed with Image Tools (UTHSCSA) software for a quantitative analysis of both parameters. Microleakage data were evaluated by ANOVA and Tukey\'s test. Gap extension before and after mechanical loading were evaluated by Student\'s t test. A correlation analysis was made between gap extension and microleakage (Pearson\'s correlation test). All groups with additional retention (G2=11,59, G3=7,11 e G4=1,57) showed fewer gap formation than control group (G1=42,43) (p< or = 0.05). Similar results were found for microleakage tests (G1= 82,84; G2=64,73; G3=45,42; G4=3,09), with significant differences between all groups (p< or = 0,05). All groups presented an increase in gap extension after loading, with exception to group with gingival retention grooves (G4). This group (G4) showed the best results in both parameters (p< or = 0.05).The results showed a tendency for correlation between the parameters. According the results, additional retention may improve marginal adaptation and minimize leakage in large class II resin composite restorations.
39

Comparação da resistência de união de diferentes superfícies dentinárias na obtenção dos espécimes para microtração / Effect of different dentin surfaces on the microtensile bond strength values

Maria Angelica Silverio Agulhari 18 May 2015 (has links)
Com intuito de aumentar a longevidade das restaurações, diversos sistemas adesivos são disponibilizados no mercado e, com isso, muitos estudos são conduzidos, dentre eles, a resistência de união desses sistemas. A maioria dos trabalhos utiliza o teste de microtração. Este teste permite a avaliação de diferentes superfícies, gerando variedade nos resultados obtidos e dificultando a comparação de dados. Este estudo teve como objetivo comparar os valores de resistência de união para as diferentes superfícies de dentina utilizadas em testes de microtração (dentina planificada e dentina de paredes cavitárias, com túbulos dentinários dispostos predominantemente paralelos ou perpendiculares à interface adesiva). Foram utilizados 80 terceiros molares humanos, divididos aleatoriamente em 4 grupos e 2 subgrupos, de acordo com a superfície dentinária de obtenção dos espécimes e do sistema adesivo utilizado: G1 (PO) planificação da face oclusal (baixo fator C); G2 (PV) planificação da face vestibular (baixo fator C); G3 (CP) face pulpar de preparo cavitário oclusal (alto fator C); G4 (CV) face vestibular de preparo oclusal (alto fator C). Dois diferentes sistemas adesivos foram utilizados: convencional de 3 passos Adper Scotchbond Multi-Purpose (3M ESPE) e o autocondicionante de 2 passos Clearfil SE Bond (kuraray), resultando em 8 subgrupos (n=10): POSMp; POCf; PVSMp; PVCf; CPSMp; CPCf; CVSMp; CVCf. A resina composta (Filtek Z250 A3) foi inserida em dois incrementos horizontais. Após 48 horas, os dentes foram seccionados com disco diamantado para a obtenção dos palitos com área de seção transversal de ±0,8mm. Uma fatia de cada subgrupo foi separada para análise em MEV. Os espécimes foram fixados ao dispositivo de microtração tipo Bencor multi T adaptado à máquina de ensaios universal Instron. Uma força de tração com velocidade de 0,5 mm/min utilizando uma célula de carga de 500N foi aplicada. As superfícies fraturadas foram analisadas em Esteromicroscópio LeicaMZ6 para identificar e classificar o tipo de fratura. Os resultados foram submetidos ao teste ANOVA a 2 critérios e ao teste de Tukey com nível de significância de 5%, para cada tipo de adesivo. Os valores médios (MPa±dp) foram: POSMp: 44.51±9.28; PVSMp: 56.75±6.58; CPSMp: 27.88±5.71;CVSMp: 32.54±6.11; POCf: 48.34±8.09; PVCf: 52.51±10.18; CPCf: 23.06±5.93; CVCf: 31.35±4.03. Houve diferença estatisticamente significante para o tipo de preparo (p<0.01 para ambos adesivos) e para a orientação dos túbulos dentinários (p<0,001 para o Scotchbond Multipurpose e p=0.012 para o Clearfil SE Bond).. Concluiu-se, portanto, que os espécimes obtidos a partir de cavidades apresentaram redução nos valores de resistência de união e a orientação paralela dos túbulos em relação à interface adesiva aumentou os valores de resistência de união à microtação. / Microtensile test is usually used to evaluate bond strength values and can be affected by several factors resulting in a diversity of values which makes it difficult to compare data. Flat surfaces dentin are used in most studies. However, specimens from a tooth cavity preparation can be a more realistic model. The aim of this study was to compare &#x3BC;TBS values of dentin flat surfaces (low C factor) and dentin from cavity preparations (high C fator) and its relation with the direction of the dentin tubules. Eighty extracted caries-free human molars were assigned into 4 groups: OF (occlusal flat surface specimens low C factor); BF (buccal flat surface specimens low C factor); PC (pulp surface of cavity preparations specimens high C factor) and BC (buccal surface of cavity preparations specimens high C factor). Each group was divided into 2 subgroups according to the adhesive system Adper Scotchbond Multi-Purpose (3M ESPE) or Clearfil SE Bond (Kuraray), resulting in 8 groups (n=10): OFSMp; OFCf; BFSMp; BFCf; PCSMp; PCCf; BCSMp and BCCf. Two horizontal increments of Filtek Z250 resin were used to restore the teeth. After 48 hours storage, the specimens were sectioned into 0.8 mm beams with diamond disc for microtensile test and submitted to a tensile force in a Universal Testing Machine (Instron) at 0.5mm/min. One slice of each subgroup was randomly selected for MEV. Mean values (MPa±sd) were OFSMp: 44.51±9.28; BFSMp: 56.75±6.58; PCSMp: 27.88±5.71; BCSMp: 32.54±6.11; OFCf: 48.34±8.09; BFCf: 52.51±10.18; PCCf: 23.06±5.93; BCCf: 31.35±4.03. Data were statistically analyzed by two-way ANOVA and Tukeys test (p<0.05) for each adhesive. The adhesive failures were predominant in all groups. It can be concluded that the microtensile bond strength was influenced by the type of dentin surface and tubules orientation. The specimens obtained from cavity preparations showed reduced &#x3BC;TBS (p<0.01). Parallel tubules orientation showed a statistically significant increase of &#x3BC;TBS (p<0.001 for Scotchbond Multipurpose and p=0.012 for Clearfil SE Bond).
40

Efetividade de corte das pontas do sistema CVDentUS : estudo in vitro /

Lima, Luciana Monti. January 2003 (has links)
Orientador: Lourdes Aparecida Martins dos Santos-Pinto / Banca: Evaldo José Corat / Banca: Celso Luiz de Angelis Porto / Resumo: A tecnologia CVD (Chemical Vapor Deposition) aplicada à confecção de pontas odontológicas diamantadas possibilitou aderência do diamante à haste metálica suficiente para suportar o efeito do ultra-som, surgindo então uma técnica alternativa para corte de tecido dentário. O objetivo deste estudo in vitro foi avaliar a efetividade dos corte realizados com as pontas CVD cilíndrica e esférica para ultra-som (pontas CVDentUSÒ), em esmalte e dentina de dentes permanentes, variando-se o sentido de movimento (frontal e lateral). Foram utilizados 40 terceiros molares, num total de 80 preparos cavitários confeccionados por meio de um dispositivo padronizador. Os cortes foram realizados com 30 movimentos consecutivos da ponta sobre a superfície dentária, correspondendo a 27 segundos de utilização das pontas CVDentUSÒ. A profundidade e largura dos preparos cavitários foram analisadas em microscopia eletrônica de varredura e medidas por meio de uma análise cefalométrica modificada no programa Radiocef 4.0 (Radiocef Memory Ltda). A análise estatística pelo teste não paramétrico de Kruskal-Wallis ao nível de significância de 5% mostrou que as maiores médias de largura e profundidade foram observadas nos preparos de dentina, sendo a ponta esférica responsável por cavidades mais profundas e a cilíndrica por cavidades mais largas, não havendo influência dos sentidos de movimento da ponta. / Abstract: The CVD (Chemical Vapor Deposition) technology applied in dental diamond burs manufacture allowed to the diamond to have enough adherence to the metallic stem supporting the ultrasound effect. This technique is bringing back an alternative method to cut dental tissue. The aim of this in vitro study was to evaluate the cutting effectiveness of cylindrical and round CVD-coated diamond burs for ultrasound (CVDentUSÒ system), in enamel and dentine of permanent teeth, changing the movement sense (frontal and lateral). Forty third molars were used, in a total of 80 cavity preparations made using a standard device. The cuts were made with 30 consecutive movements of the bur on the dental surface, corresponding to 27 seconds of CVDentUSÒ tips use. The depth and width of the cavity preparations were analyzed by scanning electronic microscopy and the measures were made using a modified cefalometric analysis in a Radiocef 4.0 program (Radiocef Memory Ltda). The statistical analysis applying Kruskal-Wallis non-parametric test, at 5% significance level, showed that the largest width and depth averages were observed in dentine cavities, being the round bur responsible for deeper cavities and the cylindrical for wider cavities. The movement senses had no influence on cavity size. / Mestre

Page generated in 0.1109 seconds