• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tribologia de um inserto metal-osso maxilar / Tribology of a maxilar jaw metal-bone insert

Sousa, Jo?o Andrade Lopes de 02 May 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-01-12T14:20:00Z No. of bitstreams: 1 JoaoAndradeLopesDeSousa_DISSERT.pdf: 61529909 bytes, checksum: e210522b263ff132558591081dbd66de (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-01-18T14:02:46Z (GMT) No. of bitstreams: 1 JoaoAndradeLopesDeSousa_DISSERT.pdf: 61529909 bytes, checksum: e210522b263ff132558591081dbd66de (MD5) / Made available in DSpace on 2017-01-18T14:02:46Z (GMT). No. of bitstreams: 1 JoaoAndradeLopesDeSousa_DISSERT.pdf: 61529909 bytes, checksum: e210522b263ff132558591081dbd66de (MD5) Previous issue date: 2016-05-02 / O n?mero de implantes e a prefer?ncia dos mesmos em rela??o ?s pr?teses v?m crescendo a cada ano no Brasil, assim como os profissionais habilitados para tal procedimento. Com isso, ? necess?rio que haja estudos sistem?ticos sobre a din?mica que ocorre entre o par osso-metal no sistema. Utilizou-se osso su?no para a confec??o dos corpos-de-prova devido ao f?cil acesso ao material. Ensaiou-se e submeteu-se em laborat?rio o sistema a esfor?os de flexo-tor??o, quantificando-se o "backlash" (folga) ap?s 10^5 ciclos. Investigou-se tamb?m danos na estrutura ?ssea devido ?s solicita??es mec?nicas c?clicas aplicadas. Tamb?m se avaliou microscopicamente o conjunto parafuso-porca. Este estudo possibilitou identificar que a temperatura registrada durante a maioria dos ensaios manteve-se numa faixa entre 20 e 30?C, a acelera??o de vibra??o global e a press?o sonora demonstram que at? 10^4 ciclos o contato entre porca calota e parafuso da haste ? n?o conforme, com rugosidade elevada, confirmando a passagem pelo per?odo de running in do par tribol?gico metal-metal, enquanto que ap?s 10^4 ciclos h? o aumento par?metros, anteriormente citados, at? o t?rmino do ensaio, passando a existir um contato conforme no per?odo de regime permanente (steady steak). O Backlash mensurado identificou um valor m?ximo m?dio de 0,49mm. Debris, forma??o de proa, trincas e delamina??o foram observadas no MEV do osso e da porca-calota. O par osso-metal ainda foi submetido a um ensaio de tra??o, obtendo-se um gr?fico for?a versus deforma??o. / The number of implants and the preference of the same in relation to prostheses have been growing every year in Brazil, as well as professionals for such a procedure. With this, a systematic study is needed on the dynamic that occurs between the pair bone-metal in the system. Swine?s bone was used for making specimen due to easy access to the material. It was tested and subjected to laboratory system flexo-torsional stresses, backlash was quantified after 105 cycles. It also was investigated damage in the bone structure due to the applied cyclic mechanical stress. Also microscopically assessed the screw-nut assembly. This study identified that the temperature during most assays was maintained in a range between 20 and 30 ? C, global vibration velocity and sound pressure showed that up to 104 cycles, the contact between nut-cap and screw of the stem is counterformal contact, with high roughness, confirming the passage of the running-in period or tribological metal-metal pair softening, whereas after 104 cycles for increased parameters mentioned above by the end the test, starting to be a contact as the steady steak period. The measured Backlash identified a maximum value of 0.49 mm. Debris, prow formation, cracks and delamination were observed in SEM bone and nut-cap. The metal-bone pair was also subjected to a tensile test, yielding a graph force versus deformation.

Page generated in 0.0531 seconds