• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistemas de microcanais em vidro para aplicações em microfluidica. / Glass microchannels systems for microfluidic applications.

Schianti, Juliana de Novais 27 May 2008 (has links)
Neste trabalho são apresentados resultados relativos ao desenvolvimento de um processo de fabricação para a produção de sistemas de microcanais em vidro tipo borosilicato, 7059 Corning Glass. O objetivo do trabalho é implementar um processo básico, mas completo, de fabricação de sistemas microfluídicos em vidro, que possam futuramente ser aprimorados com a introdução de dispositivos ópticos e eletrônicos e de elementos microfluídicos ativos, como válvulas e microbombas, para sensoreamento e controle de fluxo. O processo de fabricação foi dividido em três grandes etapas, sendo a primeira delas, a produção dos microcanais, envolvendo processos como litografia e corrosão úmida. Nos estudos de corrosão procurou-se uma solução que permitisse a obtenção de canais com superfície uniforme e lisa, sem a produção de resíduos durante a corrosão do vidro. Os melhores resultados foram obtidos com a solução HF + HCl + H2O (1:2:3), com a possibilidade de produzir canais com até 150 µm de profundidade. A segunda etapa do processo de produção dos sistemas microfluídicos envolveu o encapsulamento dos microcanais, o que foi feito através de um processo de soldagem direta (vidro com vidro) à temperatura ambiente, com aplicação de pressão entre 0,1 a 1,0 MPa. Os melhores resultados nesta etapa envolveram pressões acima de 0,5 MPa, podendo-se obter cerca de 95 - 100% da área das lâminas soldadas. A terceira etapa do processo de fabricação engloba a interconexão com o meio externo, envolvendo a produção dos furos no vidro para entrada e saída de líquidos e a introdução dos tubos de acesso para o meio externo. Para a produção dos furos foi desenvolvido um sistema posicionador computarizado que movimenta o substrato de vidro nas direções x, y e z com precisão de alguns micrometros, garantindo o alinhamento necessário entre as duas lâminas de vidro que devem ser soldadas para encapsular os microcanais. Os furos foram feitos com broca diamantada de uso odontológico fixa em uma furadeira comum. Cateteres e scalps de uso médico foram empregados como tubos de acesso, sendo selados com resina epóxi. Os sistemas microfluídicos fabricados foram testados monitorando o fluxo de soluções aquosas de anilina, o qual foi mantido através de bomba peristáltica. Os resultados se mostraram reprodutíveis, tendo se obtido microcanais lisos e sem resíduos, sem apresentar vazamentos e exibindo regime de fluxo tipicamente laminar. Em conjunto, estes resultados mostraram-se muito promissores para desenvolvimento futuro de aplicações em áreas como Biotecnologia e Análises Químicas. / In this work, a process for the fabrication of microchannels over borlosilicate 7059 Corning Glass is presented. The main objective is to develop a simple and complete process for the fabrication of microfluidic systems over glass, that can be further improved in the future, with the integration of optical, electronic and active microfluidic devices such as valves and micropumps, for sensing and flow control. The fabrication process has three main parts. The first part is the microchannel production, which is achieved through contact-lithography and wet etching. In the etching studies, a solution that led to the fabrication of channels with uniform and smooth surfaces, without residue formation was sought. The best results were attained with a HF + HCl + H2O (1:2:3), which allow for the production of channels with depths of up to 150 µm. The second part of the fabrication process is the microchannels encapsulation, which is achieved through direct (glass-glass) bonding at room temperature, with applied pressure ranging from 0.1 to 1.0 MPa. The best results were obtained with pressure values above 0.5 MPa, which allowed for the bonding of up to 95 -100% of the glass sufaces. The third part of the fabrication process concerns the interconnection with the outside environment, which involves hole production and the introduction of tubes, to allow external access of liquids. For the hole production, a computer controlled positioning system was developed, for accurate positioning of the glass substrate in the x, y and z directions, with a precision of a few micrometers. This system guaranteed the necessary alignment of the upper and lower glass substrates, which were bonded for the encapsulation of the microchannels. The holes were made with diamond burs with a common drill. Medical catheters and scalps were used as access tubes, with epoxy resin. The characterization of the fabricated microfluidic systems was achieved by monitoring the flow of aniline aqueous solutions, which was maintained through a peristaltic pump. Reproducible results were obtained, with the production smooth and residue free microchannels, which did not present leakage and exhibited a laminar flow behavior. These results are very promising for the future application of this process in the fabrication of devices for areas such as biotechnology and chemical analysis, among others.
2

Sistemas de microcanais em vidro para aplicações em microfluidica. / Glass microchannels systems for microfluidic applications.

Juliana de Novais Schianti 27 May 2008 (has links)
Neste trabalho são apresentados resultados relativos ao desenvolvimento de um processo de fabricação para a produção de sistemas de microcanais em vidro tipo borosilicato, 7059 Corning Glass. O objetivo do trabalho é implementar um processo básico, mas completo, de fabricação de sistemas microfluídicos em vidro, que possam futuramente ser aprimorados com a introdução de dispositivos ópticos e eletrônicos e de elementos microfluídicos ativos, como válvulas e microbombas, para sensoreamento e controle de fluxo. O processo de fabricação foi dividido em três grandes etapas, sendo a primeira delas, a produção dos microcanais, envolvendo processos como litografia e corrosão úmida. Nos estudos de corrosão procurou-se uma solução que permitisse a obtenção de canais com superfície uniforme e lisa, sem a produção de resíduos durante a corrosão do vidro. Os melhores resultados foram obtidos com a solução HF + HCl + H2O (1:2:3), com a possibilidade de produzir canais com até 150 µm de profundidade. A segunda etapa do processo de produção dos sistemas microfluídicos envolveu o encapsulamento dos microcanais, o que foi feito através de um processo de soldagem direta (vidro com vidro) à temperatura ambiente, com aplicação de pressão entre 0,1 a 1,0 MPa. Os melhores resultados nesta etapa envolveram pressões acima de 0,5 MPa, podendo-se obter cerca de 95 - 100% da área das lâminas soldadas. A terceira etapa do processo de fabricação engloba a interconexão com o meio externo, envolvendo a produção dos furos no vidro para entrada e saída de líquidos e a introdução dos tubos de acesso para o meio externo. Para a produção dos furos foi desenvolvido um sistema posicionador computarizado que movimenta o substrato de vidro nas direções x, y e z com precisão de alguns micrometros, garantindo o alinhamento necessário entre as duas lâminas de vidro que devem ser soldadas para encapsular os microcanais. Os furos foram feitos com broca diamantada de uso odontológico fixa em uma furadeira comum. Cateteres e scalps de uso médico foram empregados como tubos de acesso, sendo selados com resina epóxi. Os sistemas microfluídicos fabricados foram testados monitorando o fluxo de soluções aquosas de anilina, o qual foi mantido através de bomba peristáltica. Os resultados se mostraram reprodutíveis, tendo se obtido microcanais lisos e sem resíduos, sem apresentar vazamentos e exibindo regime de fluxo tipicamente laminar. Em conjunto, estes resultados mostraram-se muito promissores para desenvolvimento futuro de aplicações em áreas como Biotecnologia e Análises Químicas. / In this work, a process for the fabrication of microchannels over borlosilicate 7059 Corning Glass is presented. The main objective is to develop a simple and complete process for the fabrication of microfluidic systems over glass, that can be further improved in the future, with the integration of optical, electronic and active microfluidic devices such as valves and micropumps, for sensing and flow control. The fabrication process has three main parts. The first part is the microchannel production, which is achieved through contact-lithography and wet etching. In the etching studies, a solution that led to the fabrication of channels with uniform and smooth surfaces, without residue formation was sought. The best results were attained with a HF + HCl + H2O (1:2:3), which allow for the production of channels with depths of up to 150 µm. The second part of the fabrication process is the microchannels encapsulation, which is achieved through direct (glass-glass) bonding at room temperature, with applied pressure ranging from 0.1 to 1.0 MPa. The best results were obtained with pressure values above 0.5 MPa, which allowed for the bonding of up to 95 -100% of the glass sufaces. The third part of the fabrication process concerns the interconnection with the outside environment, which involves hole production and the introduction of tubes, to allow external access of liquids. For the hole production, a computer controlled positioning system was developed, for accurate positioning of the glass substrate in the x, y and z directions, with a precision of a few micrometers. This system guaranteed the necessary alignment of the upper and lower glass substrates, which were bonded for the encapsulation of the microchannels. The holes were made with diamond burs with a common drill. Medical catheters and scalps were used as access tubes, with epoxy resin. The characterization of the fabricated microfluidic systems was achieved by monitoring the flow of aniline aqueous solutions, which was maintained through a peristaltic pump. Reproducible results were obtained, with the production smooth and residue free microchannels, which did not present leakage and exhibited a laminar flow behavior. These results are very promising for the future application of this process in the fabrication of devices for areas such as biotechnology and chemical analysis, among others.
3

Estudo teórico-experimental do efeito da flexão da ferramenta no processo de microfresamento / Theorical and experimental study on tool deflection effect in micromilling process

Arai, Ricardo 15 September 2008 (has links)
A flexão da ferramenta, em operações de fresamento de topo, é responsável por interferir negativamente na qualidade superficial da peça a ser usinada e, muitas vezes, pela quebra prematura da mesma. O presente trabalho tem como objetivo estudar experimentalmente os efeitos da flexão de fresas de topo com 0,8 mm de diâmetro no processo de microfresamento. Os ensaios experimentais foram realizados com o intuito de identificar quais parâmetros de corte apresentam maior influência na flexão da ferramenta. Os parâmetros de corte escolhidos para estudo foram: velocidade de corte, velocidade de avanço, profundidade de usinagem e penetração de trabalho. Os ensaios investigam, além das faixas de parâmetros recomendados pelo fabricante da ferramenta, uma condição 25% acima e outra 25% abaixo para todos os parâmetros estudados. O monitoramento de forças de corte foi realizado em todos os ensaios. As forças obtidas se mostraram diretamente relacionadas com a área de secção de corte, conforme teoria básica. Para fins comparativos, a força máxima obtida experimentalmente foi aplicada na simulação com elementos finitos (FEM - Finite Element Method) da ferramenta e indicou um comportamento similar ao de uma viga engastada. A análise microscópica do aspecto superficial da usinagem mostrou que menores avanços por dente resultam em um melhor acabamento confirmando resultados do processo convencional. O conhecimento do efeito dos parâmetros de corte no processo de microfresamento tem o intuito de oferecer informações às empresas do setor no sentido de melhorar o planejamento e processo de fabricação. / The tool deflection, in end milling operations, is responsible to intervene negatively on the workpiece surface quality and can also cause a premature tool failure (breakage).The present work aims at studying experimentally the effects of tool deflection when end milling with 0,8 mm diameter in microoperations. The experimental tests had intended to identify which parameters of milling show more influence in tool deflection. The chosen milling parameters for the study were: cutting speed, feed rate, depth of cut and step over. The tests aim to investigate, beside the recommended parameters from tool manufacturer, a 25% higher and 25% lower conditions. The force acquisition was made in all tests. The measured forces shown that they are directly related to the uncut chip cross section, in accordance with theory. For comparative purpose, the maximum experimental force value was applied in the finite elements method (FEM) simulation of the tool and indicates a similar behavior of an encastré beam. The microscopic analysis of the superficial aspect of the milling showed that smaller feed per tooth results in better finishing, as observed in the conventional process. The knowledge of the effect of the cutting parameters in the micromilling process has the intention of offering information for industries to improve the planning and process of manufacturing.
4

Estudo teórico-experimental do efeito da flexão da ferramenta no processo de microfresamento / Theorical and experimental study on tool deflection effect in micromilling process

Ricardo Arai 15 September 2008 (has links)
A flexão da ferramenta, em operações de fresamento de topo, é responsável por interferir negativamente na qualidade superficial da peça a ser usinada e, muitas vezes, pela quebra prematura da mesma. O presente trabalho tem como objetivo estudar experimentalmente os efeitos da flexão de fresas de topo com 0,8 mm de diâmetro no processo de microfresamento. Os ensaios experimentais foram realizados com o intuito de identificar quais parâmetros de corte apresentam maior influência na flexão da ferramenta. Os parâmetros de corte escolhidos para estudo foram: velocidade de corte, velocidade de avanço, profundidade de usinagem e penetração de trabalho. Os ensaios investigam, além das faixas de parâmetros recomendados pelo fabricante da ferramenta, uma condição 25% acima e outra 25% abaixo para todos os parâmetros estudados. O monitoramento de forças de corte foi realizado em todos os ensaios. As forças obtidas se mostraram diretamente relacionadas com a área de secção de corte, conforme teoria básica. Para fins comparativos, a força máxima obtida experimentalmente foi aplicada na simulação com elementos finitos (FEM - Finite Element Method) da ferramenta e indicou um comportamento similar ao de uma viga engastada. A análise microscópica do aspecto superficial da usinagem mostrou que menores avanços por dente resultam em um melhor acabamento confirmando resultados do processo convencional. O conhecimento do efeito dos parâmetros de corte no processo de microfresamento tem o intuito de oferecer informações às empresas do setor no sentido de melhorar o planejamento e processo de fabricação. / The tool deflection, in end milling operations, is responsible to intervene negatively on the workpiece surface quality and can also cause a premature tool failure (breakage).The present work aims at studying experimentally the effects of tool deflection when end milling with 0,8 mm diameter in microoperations. The experimental tests had intended to identify which parameters of milling show more influence in tool deflection. The chosen milling parameters for the study were: cutting speed, feed rate, depth of cut and step over. The tests aim to investigate, beside the recommended parameters from tool manufacturer, a 25% higher and 25% lower conditions. The force acquisition was made in all tests. The measured forces shown that they are directly related to the uncut chip cross section, in accordance with theory. For comparative purpose, the maximum experimental force value was applied in the finite elements method (FEM) simulation of the tool and indicates a similar behavior of an encastré beam. The microscopic analysis of the superficial aspect of the milling showed that smaller feed per tooth results in better finishing, as observed in the conventional process. The knowledge of the effect of the cutting parameters in the micromilling process has the intention of offering information for industries to improve the planning and process of manufacturing.

Page generated in 0.105 seconds