• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de procedimentos em fluxo envolvendo reatores em fase sólida e microssistema analítico construído com LTCC (Low Temperature Co-fired Ceramics) para a determinação de analitos de interesse farmacêutico / DEVELOPMENT OF FLOW PROCEDURES INVOLVING SOLID-PHASE REACTOR AND ANALYTICAL MICROSYSTEM CONSTRUCTED WITH LTCC (LOW TEMPERATURE CO-FIRED CERAMICS) TO DETERMINATION OF ANALYTES OF PHARMACEUTICAL INTEREST

Suarez, Willian Toito 20 March 2009 (has links)
Made available in DSpace on 2016-06-02T20:34:10Z (GMT). No. of bitstreams: 1 2566.pdf: 3291164 bytes, checksum: 8f80bfd807f7f259b60940cfafe2a125 (MD5) Previous issue date: 2009-03-20 / Universidade Federal de Sao Carlos / The employment of flow injection systems to determination of N-acetylcysteine, captopril, dipyrone and fluoxetine hydrochloride in pharmaceutical formulations was investigated. The N-acetylcysteine was determinated employing a solid-phase reactor containing Zn3(PO4)2 immobilized in a polyester resin coupled to a flow injection system. The procedure was based on the chelation of Zn(II) ions with N-acetylcysteine in the solid-phase reactor, with consequent releasing of the complex Zn(II)-N-acetylcysteine of the reactor, this complex reacted with alizarin red S (VA) in borate buffer pH 9.0 generating the complex Zn(VA-BO3)3 which absorbance was measured spectrophotometrically at 540 nm. The second developed procedure was the determination of captopril (CAP) in pharmaceutical formulations employing a solid-phase reactor containing silver chrolanilate (Ag2C6Cl2O4) immobilized in a polyester resin. In this system occured the precipitation reaction of captopril with the Ag(I), producing in the reactor an insoluble salt between the CAP and the Ag(I) due to the lower solubility of the formed salt related to Ag2C6Cl2O4. After the formation of the insoluble salt in the reactor occured the releasing of chloranilate anion, C6Cl2O4 2-, that reacted with the Fe(III) producing the complex FeC6Cl2O4 + which was monitored spectrophotometrically at 528 nm. In another procedure, the N-acetylcysteine and captopril were determined separately in a flow injection system through the on-line of the Prussian blue formation. In this procedure, the N-acetylcysteine or the captopril were oxidized by Fe(III), producing Fe(II) that reacted with hexacyanoferrate(III) in a point of flow system, generating the Prussian blue (Fe4[Fe(CN)6]3), that was monitored spectrophotometrically at 700 nm. It was also proposed a flow injection system with merging zones and intermittent flow with turbidimetric detection to determination of fluoxetine hydrochloride in pharmaceuticals. This system was based on the formation of an insoluble salt (AgCl(s)) between the AgNO3 and the chloride of the hydrochloride of the fluoxetine molecule that was turbidimetrically detected at 420 nm. Finally, two procedures were developed employing a flow injection system to determination of dipyrone in pharmaceuticals using Fe(III) as chromogenic reagent. In the first procedure, it was employed an analytical microsystem constructed with LTCC and in the second one, it was used a flow injection system with merging zones without the use of microsystem. In these systems, occured the formation on-line of an blue chromophore between Fe(III) and the dipyrone that was monitored spectrophotometrically at 622 nm. / O emprego de sistemas de análise por injeção em fluxo para a determinação de N-acetilcisteína, captopril, dipirona e cloridrato de fluoxetina em formulações farmacêuticas foi investigado. A N-acetilcisteína foi determinada empregando um reator em fase sólida contendo fosfato de zinco imobilizado em resina poliéster acoplado ao sistema FIA. O procedimento baseou-se na complexação dos íons Zn(II) pela N-acetilcisteína no reator em fase sólida, com consequente remoção do complexo Zn(II)-N-acetilcisteína do reator, esse complexo reagiu com o regente vermelho de alizarina S (VA), em tampão borato pH 9,0, formando o complexo Zn(VA-BO3)3 cuja absorbância foi monitorada espectrofotometricamente em 540 nm. O segundo procedimento desenvolvido foi a determinação de captopril empregando um reator em fase sólida contendo cloranilato de prata (Ag2C6Cl2O4) imobilizado em resina poliéster. Esse sistema baseou-se na reação de precipitação do captopril com Ag(I), gerando no reator um sal insolúvel entre o captopril e Ag(I) devido à menor solubilidade do sal formado em relação ao Ag2C6Cl2O4. Após a formação do sal insolúvel no reator ocorreu o deslocamento do ânion cloranilato, C6Cl2O4 2-, que reagiu com o Fe(III) em um ponto de confluência do sistema em fluxo produzindo o complexo FeC6Cl2O4 + que foi monitorado espectrofotometricamente em 528 nm. Em um outro procedimento, a N-acetilcisteína e o captopril foram determinados separadamente em um sistema de análise por injeção em fluxo através da formação em linha do azul da Prússia. Nesse procedimento, a N-acetilcisteína ou o captopril foram oxidados pelo Fe(III), produzindo Fe(II) que reagiu com hexacianoferrato(III) em um ponto de confluência do sistema FIA, gerando o azul da Prússia (Fe4[Fe(CN)6]3), que foi monitorado espectrofotometricamente em 700 nm. Foi proposto também um sistema de análise por injeção em fluxo com zonas coalescentes e fluxo intermitente com detecção turbidimétrica para a determinação de cloridrato de fluoxetina em produtos farmacêuticos. O sistema baseou-se na reação entre o cloreto do cloridrato de fluoxetina e o nitrato de prata (AgNO3), formando o (AgCl(s)), que foi monitorado turbidimetricamente em 420 nm. Por último, foram desenvolvidos dois procedimentos empregando sistema de análise por injeção em fluxo para a determinação de dipirona em formulações farmacêuticas utilizando Fe(III) como reagente cromogênico. No primeiro procedimento foi empregado um microssistema analítico construído com LTCC e no segundo foi utilizado um sistema FIA com zonas coalescentes sem o acoplamento do microssistema. Nesses sistemas, sucedeu a formação em linha de um cromóforo azul, a partir da reação entre o Fe(III) e a dipirona, que foi monitorado espectrofotometricamente em 622 nm.
2

Desenvolvimento de procedimentos analíticos para a determinação de N-acetilcisteína em produtos farmacêuticos. / Development of analytical procedures for determination of n-acetylcysteine in pharmaceutical formulations.

Suarez, Willian Toito 17 February 2005 (has links)
Made available in DSpace on 2016-06-02T20:36:10Z (GMT). No. of bitstreams: 1 1426.pdf: 2212976 bytes, checksum: 075a2ca195e9ee733003690b11772140 (MD5) Previous issue date: 2005-02-17 / Universidade Federal de Sao Carlos / In this dissertation four analytical procedures for the determination of Nacetylcysteine in pharmaceutical formulations are described. The first procedure developed was a flow injection analysis system for turbidimetric determination of Nacetylcysteine employing Ag+ ions in an acid medium as the precipitant reagent. In this system, 250 µL of 0.01 mol L-1 AgNO3 solution and 500 µL of sample solution were inserted simultaneously into a merging zones flow system. After the precipitate formation in a 100 cm coil reactor, the precipitate generated was monitored turbidimetrically at 400 nm. Desionised water flowing intermittently at 6.3 mL min-1 was used to wash out the precipitate during the sampling stage. The analytical curve was linear in the N-acetylcysteine concentration range from 1.0 x 10-4 to 1.0 x 10-3 mol L-1; with a detection limit of 8.0 x 10-5 mol L-1 (3σB/slope) and sampling frequency of 60 h-1 was obtained. The relative standard deviation was smaller than 1% for Nacetylcysteine solutions in the concentrations of 1.0 x 10-4 and 5.0 x 10-4 mol L-1 (n=20). The recoveries obtained for two samples ranged from 104 to 122%. A flow injection system with spectrophotometric detection is proposed for determining Nacetylcysteine in pharmaceutical formulations. In this system, N-acetylcysteine was oxidized by Fe(III) and the Fe(II) produced is spectrophotometrically monitored as Fe(II)-1,10-phenantroline complex at 515 nm. Under the optimum analytical conditions, the linearity of the calibration graph for N-acetylcysteine ranged from 1.8 x 10-5 to 1.5 x 10-4 mol L-1. The detection limit of 6.3 x 10-6 mol L-1 (3σB/slope) and recoveries between 102 to 113 % were obtained. The preparation and electrochemical characterization of a carbon paste electrode modified with copper (II) hexacyanoferrate(III) (CuCHF) as well as its behaviour as electrocatalyst toward the oxidation of N-acetylcysteine were investigated. The electrochemical behaviour of the modified electrode and the electrooxidation of N-acetylcysteine were explored using sweep linear voltammetry. The best voltammetric response was observed for a paste composition of 20%(w/w) copper (II) hexacyanoferrate(III) complex, acetate buffer solution at pH of 6.0 as the electrolyte and scan rate of 10 mV s-1. A linear voltammetric response for N-acetylcysteine was obtained in the concentration range xiv from 1.2 x 10-4 to 8.3 x 10-4 mol L-1, with a detection limit of 6.3 x 10-5 mol L-1 (3σB/slope). The proposed electrode is useful for the quality control and routine analysis of N-acetylcysteine in pharmaceutical formulations. Finally, a simple, precise, rapid and low-cast potentiometric method for N-acetylcysteine determination in pure form and in pharmaceutical preparations is proposed. N-acetylcysteine present in tablets containing known quantity of drug was potentiometrically titrated in aqueous solution with AgNO3. No interferences were observed in the presence of common components of the tablets as saccharin, sucrose and EDTA. The analytical results obtained by applying the proposed method compared very favorably with those obtained by the comparative method. Recovery of N-acetylcysteine from various tablets dosage formulations range from 98.7 to 103.0%. Compared to others procedures reported in the literature the procedures developed in this dissertation shows to be better and cheaper to determination of N-acetylcysteine in pharmaceutical formulations. / Nessa dissertação descreve-se quatro procedimentos analíticos para a determinação de N-acetilcisteína em formulações farmacêuticas. O primeiro procedimento desenvolvido foi um sistema de análise por injeção em fluxo para a determinação turbidimétrica de N-acetilcisteína empregando como reagente precipitante íons Ag+ em meio ácido. Nesse sistema, solução do reagente AgNO3 0,01 mol L-1 e da amostra foram inseridos simultaneamente em zonas coalescentes em volume de 250 e 500 µL, respectivamente. Após a formação do precipitado em uma bobina reacional de 100 cm, o produto gerado foi monitorado turbidimetricamente em 400 nm. Adaptou-se um fluxo intermitente de água desionizada a uma vazão de 6,3 mL min-1 para a limpeza do sistema durante a amostragem. A curva analítica foi linear no intervalo de concentração de Nacetilcisteína de 1,0 x 10-4 a 1,0 x 10-3 mol L-1, com limite de detecção de 8,0 x 10-5 mol L-1 (3σB/inclinação) e freqüência de amostragem de 60 h-1. Os desvios padrões relativos foram menores que 1% para soluções de N-acetilcisteína de 1,0 x 10-4 e 5,0 x 10-4 mol L-1 (n=20). Os valores do teste de recuperação em duas amostras comerciais variaram na faixa de 104 a 122%. Como um segundo procedimento, um sistema de análise por injeção em fluxo com detecção espectrofotométrica foi proposto. Nesse sistema, N-acetilcisteína foi oxidada por Fe(III), sendo o Fe(II) produzido monitorado espectrofotometricamente como Fe(II)-1,10-ortofenantrolina em 515 nm. Sobre as condições analíticas otimizadas, a curva analítica foi linear em um intervalo de concentração de N-acetilcisteína entre 1,8 x 10-5 a 1,5 x 10-4 mol L-1. O limite de detecção obtido foi de 6,3 x 10-6 mol L-1 (3σB/inclinação) e as recuperações variaram na faixa de 102 a 113%. A caracterização e a preparação de um eletrodo de pasta de carbono modificado com hexacianoferrato de cobre(II) (CuHCF) foi investigado. O comportamento eletroquímico do eletrodo modificado para eletrooxidação da N-acetilcisteína foi explorado usando voltametria linear. As melhores respostas voltamétricas foram: composição da pasta de carbono de 20% (m/m) do complexo de hexacianoferrato de cobre(II), solução tampão acetato como xii solução eletrolítica e velocidade de varredura de potenciais de 10 mV s-1. A curva analítica foi linear na região de concentração de N-acetilcisteína entre 1,2 x 10-4 a 8,3 x 10-4 mol L-1, com um limite de detecção de 6,3 x 10-5 mol L-1 (3σB/inclinação). O eletrodo proposto foi usado para o controle e análise de rotinas de formulações farmacêuticas. Finalmente, um método potenciométrico simples, preciso, rápido e de baixo custo foi proposto para a determinação de N-acetilcisteína na forma pura e em formulações farmacêuticas. A N-acetilcisteína presente em formulações farmacêuticas foi determinada potenciometricamente empregando-se como titulante uma solução aquosa de AgNO3. Interferências não foram observadas na presença de componentes comumente encontrados nas formulações farmacêuticas, a saber: sacarina, sacarose e EDTA. Os resultados analíticos obtidos a partir da aplicação do método proposto estão em uma boa concordância com aqueles obtidos pelo método comparativo. A recuperação obtida para a N-acetilcisteína em várias formulações farmacêuticas variou de 98,7 a 103,0%. Em comparação com a maioria dos procedimentos descritos na literatura, os procedimentos desenvolvidos nessa dissertação mostraram-se ser mais baratos e simples para a determinação de Nacetilcisteína em formulações farmacêuticas.

Page generated in 0.0816 seconds