Spelling suggestions: "subject:"prostheses anda implants"" "subject:"prostheses ando implants""
11 |
Osteoconduction of calcium phosphate thin film on porous-surfaced implants in rabbit tibiaeNguyen, Hung Quoc, January 1998 (has links)
Thesis (M. Sc.)--University of Toronto, 1998. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
12 |
Osteoconduction of calcium phosphate thin film on porous-surfaced implants in rabbit tibiaeNguyen, Hung Quoc, January 1998 (has links)
Thesis (M. Sc.)--University of Toronto, 1998. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
13 |
Effects of implant surface topography on osteoconductionDziedzic, Dilcele Silva Moreira, January 1995 (has links)
Thesis (M. Sc.)--University of Toronto, 1995. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
14 |
Porous polymethylmethacrylate cement development and evaluation of a potential implant material /Wijn, Joost Robert de, January 1982 (has links)
Thesis (doctoral)--Katholieke Universiteit te Nijmegen.
|
15 |
Effects of implant surface topography on osteoconductionDziedzic, Dilcele Silva Moreira, January 1995 (has links)
Thesis (M. Sc.)--University of Toronto, 1995. / Includes bibliographical references.
|
16 |
Development of injectable hydrogels for nucleus pulposus replacement /Thomas, Jonathan D. Lowman, Anthony M. Marcolongo, Michele S. January 2006 (has links)
Thesis (Ph. D.)--Drexel University, 2006. / Includes abstract and vita. Includes bibliographical references (leaves 170-193).
|
17 |
Analise fotoelastica das tensões induzidas por infra-estruturas implanto-suportadas obtidas pelas tecnicas de cimentação dos cilindros e soldagem a laser, antes e apos eletroerosão / Photoelastic analysis of stress transmitted from implant-supported frameworks achieved by cilinders lutingand laser welding techniques before and after eletric discharge machiningBarberi, Juliana Tamião 30 May 2007 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T19:07:40Z (GMT). No. of bitstreams: 1
Barberi_JulianaTamiao_M.pdf: 6032748 bytes, checksum: 3f9207c911e4693fec735f279de88fa3 (MD5)
Previous issue date: 2007 / Resumo: O presente estudo avaliou o assentamento passivo em infra-estruturas de próteses fixas implanto-suportadas, através de análise fotoelástica da distribuição de tensões em virtude do grau de desadaptação. A partir de uma matriz metálica no formato e dimensões similares a um arco mandibular, contendo cinco análogos de pilares Micro-Unit (Conexão ¿ São Paulo), foram confeccionadas duas estruturas metálicas fundidas em titânio comercialmente puro (Tritan® ¿ Dentaurum ¿ Alemanha), obtidas pelas seguintes técnicas: Estrutura I, cilindros cimentados com ionômero de vidro modificado por resina (RelyX® Luting 2 ¿ 3M ESPE); e Estrutura II, cilindros soldados a laser e subsequente refinamento por eletroerosão (EDM). A partir de um molde de silicone de duplicação foi confeccionado um modelo em resina fotoelástica (Araldite® GY279BR Huntsman ¿ Araltec Produtos Químicos Ltda. ¿ Guarulhos ¿ São Paulo) com cinco implantes incorporados e pilares Micro-Unit. As estruturas foram então submetidas à análise fotoelástica conduzida pelo aperto dos parafusos na seqüência preconizada 3,2,4,1,5. Seqüencialmente, mensurações foram realizadas na interface estrutura/pilar intermediário com auxílio de um microscópio mensurador, com precisão de 0,0005mm (STM Digital ¿ Olympus ¿ Japão) através do teste do parafuso único. A estrutura dos cilindros cimentados apresentou os melhores resultados com menor valor de desadaptação (42,37 mm) e maior distribuição das tensões, quando comparada à estrutura dos cilindros soldados a laser (83,66 mm), a qual após o procedimento de EDM e subseqüente análise fotoelástica demonstrou redução no grau de desadaptação (53,7 mm) e melhor distribuição de tensão. Pode-se concluir que o processo de cimentação dos cilindros à estrutura optimiza a adaptação marginal desta e minimiza os padrões de tensões, sendo eficaz para a obtenção do assentamento passivo / Abstract: The purpose of the study was to evaluate the passive fit of fixed implantsupported prothesis titanium frameworks, through photoelastic stress analysis. Two frameworks welded in commercially pure titanium (Tritan® ¿ Dentaurum ¿ Germany) were fabricated by two methods based on a metal model composed of five analogous Micro-Unit (Conexão ¿ São Paulo): Framework I, abutment-luted with resin-modified glass ionomer luting cement (RelyX® Luting 2 ¿ 3M ESPE); and framework II, cylinders laser-welding technique and was then refined using electric discharge machining. Photoelastic model was obtained (Araldite® GY279BR Huntsman ¿ Araltec Produtos Químicos Ltda. ¿ Garulhos ¿ São Paulo) with five fixtures and abutments Micro-Unit. Strains were produced around the implant bodies when screws retaining the prosthesis were tightened sequence 3,2,4,1,5, and strains were evaluated by photoelastic analysis. The interfacial gaps between the abutments and fixture were measuremented with an optical microscope (STM Digital ¿ Olympus ¿ Japan) 0,0005mm of precision. The interfacial gaps were smaller in the abutment-luted framework (42,37 mm), demonstrated the lower stress when compared to the laser-welded cylinder framework (83,66 mm). The electric discharge machining (EDM) reduced the gaps at the interfaces (53,7 mm) and the strains for framework welded. It may be concluded that the process of abutment-luted realized in frameworks improves the precise fit of it, can be recommended of achieving precise fit of implant-supported prothesis / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
18 |
Análise da passividade e adaptação de infraestruturas de Ti com soldagem a laser vertical e horizontal de borda, cilindro cimentado ou processo CAD/CAM / Analysis of passivity and adaptation of infrastructures Ti laser welding with vertical and horizontal edge, cemented cylinder or process CAD/CAMSilva, Maíra Daysê Moreira Serra e 06 July 2013 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T01:37:01Z (GMT). No. of bitstreams: 1
Silva_MairaDayseMoreiraSerrae_D.pdf: 4199149 bytes, checksum: b778f7577a1646d77910c20b05ac939f (MD5)
Previous issue date: 2013 / Resumo: Este estudo comparou diferentes técnicas para obtenção de infraestruturas protéticas implantossuportadas com menores desajustes verticais e melhor passividade. A partir de uma matriz metálica com paredes planas e dimensões de altura, comprimento e espessura de 25 X 70 X 10 mm, contendo 4 análogos de microunits (3,75 X 13 mm), foram confeccionadas 25 amostras separadas em cinco grupos (n=5): Grupo IM infraestruturas fundidas em monobloco; Grupo ISS infraestruturas fundidas seccionadas e unidas com um ponto de solda a laser; Grupo ICC infraestruturas parafusadas com cilindros cimentados; Grupo ISB infraestruturas submetidas à soldagem de borda com solda a laser; Grupo TCC infraestruturas confeccionadas pelo processo CAD/CAM (Computer Aided Design/Computer Aided Manufacturing). Foram realizadas leituras de desadaptação marginal vertical das infraestruturas, sobre a matriz metálica, em microscópio óptico com precisão de 1,0 ?m e aumento de 120 X. As desadaptações foram quantificadas seguindo o protocolo do teste do parafuso único após torque no parafuso protético de uma das extremidades ( 10 Ncm) e verificado a adaptação nos outros três pilares. Com o intuito de avaliar a passividade das infraestruturas foram analisadas, pela técnica da fotoelasticidade, as tensões geradas nos implantes após aperto de todos os parafusos com auxílio de polariscópio circular equipado com software, capaz de realizar análises qualitativa e quantitativa das tensões. Os valores de desajuste e tensão foram tabulados e submetidos à análise estatística (SAS versão 9.1 - The SAS Institute, Cary, NC, EUA). Para as comparações entre técnica e desajuste vertical foi feito o teste ANOVA com um fator e teste de Tukey (? = 0,05%), e para as comparações das tensões cisalhantes foi realizado ANOVA dois fatores e teste de Tukey (? = 0,05%). Os resultados mostraram que o grupo IM apresentou maior desadaptação marginal; os grupos ISS e ICC apresentaram significativa adaptação marginal e menor concentração de tensão quando comparado ao grupo IM, com a vantagem do grupo ICC eliminar o seccionamento e soldagem; o grupo ISB apresentou melhor adaptação marginal quando comparadas as infraestruturas fundidas, porém com significativa concentração de franjas e tensão nos implantes, e a tecnologia CAD/CAM produziu infraestruturas com melhor adaptação marginal e tensão distribuída de forma equilibrada. Pode-se concluir que técnicas que eliminam ou reduzem pontos de solda como, ISS, ICC e TCC melhoram a passividade e diminuem desadaptação marginal vertical de infraestruturas extensas implantossuportadas / Abstract: This study compared different techniques for obtaining prosthetic implantinfrastructures with lower vertical misfits and passivity. Starting from an metallic with plane walls and dimensions of height, length and thickness of 25 X 70 X 10 mm containing four microunits analogues (3.75 X 13 mm), were prepared twentyfive samples were prepared and divided into five groups (n = 5): Group IM onepiece casted frameworks, Group ISS one-piece casted frameworks sectioned and welded with laser welding; Group ICC with cylinders cemented; Group ISB with cylinders laser-welded, Group TCC frameworks fabricated by the CAD/CAM process (Computer Aided Design / Computer Aided Manufacturing). Measurements were accomplished of the frameworks vertical misfit on metal matrix, in an optical microscope with accuracy of 1.0?m and increased 120 X. The Misfits were quantified according to the protocol of the single screw test after 10Ncm torque on the prosthetic screw and verified the adjustment on the other pillars. Aiming to evaluate the passive infrastructure were analyzed by the technique of photoelasticity the tensions generated in the implants after torque of all screws with the aid of a circular polariscope equipped with software able of performing qualitative and quantitative analyzes of tensions. The misfit values and tension were subjected to statistical analysis (SAS version 9.1 - The SAS Institute, Cary, NC, USA). For comparisons between technical and vertical misfit was done with one way - ANOVA and Tukey's test. (? = 0,05%), and for comparisons of fringe orders and shear stress was performed two factors ANOVA and Tukey test (? = 0,05%). The results showed that the IM group showed higher marginal discrepancy; group ISS and ICC showed significant marginal adaptation and lower stress concentration when compared to IM, with the advantage the ICC group of eliminate sectioning and welding; ISB group showed better marginal adaptation in casted frameworks, but with significant concentration fringe and tension in implants and CAD/CAM technology produced frameworks with best average marginal fit and tension. It can be concluded that techniques that reduce or eliminate welding points as ISS, ICC and TCC improves the passivity and reduce vertical misfit of extensive infrastructure supported by implants / Doutorado / Protese Dental / Doutora em Clínica Odontológica
|
19 |
Efeito de cargas compressivas oblíquas e da simulação de ciclos mastigatório sobre pilares para implantes cone morse / Effects of oblique compressive load and simulated chewing cycles on internal tapered implant-abutment connectionsMoris, Izabela Cristina Mauricio 15 December 2011 (has links)
A literatura relata que a união osso/implante é extremamente confiável, porém limitações clínicas em relação à prótese ainda ocorrem. Recentemente foi proposto um pilar para implantes cone morse cujo desenho permite a escolha entre coroas cimentadas ou parafusadas, adicionalmente, este pilar também é apresentado em dois tamanhos, o convencional (ø 4,8 mm) e reduzido (ø 3,8 mm). O objetivo deste estudo foi avaliar a resistência à deformação dos pilares protéticos, a resistência de cimentação das coroas e os efeitos da simulação de ciclos mastigatórios sobre: adaptação marginal, perda de torque nos parafusos das coroas e perda de torque dos dois diferentes pilares. Para avaliar a resistência à deformação, 20 implantes/pilares com diâmetro de 4.8 e 3.8 foram submetidos à carga compressiva oblíqua. Para avaliar as outras situações, 40 implantes/pilares foram divididos nos seguintes grupos (N=10): G4.8P- pilar de 4.8 e coroas parafusadas; G4.8C-pilar de 4.8 e coroas cimentadas; G3.8P- pilar de 3.8 e coroas parafusadas; G3.8C- pilar de 3.8 e coroas cimentadas. Todas as coroas foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios e as coroas cimentadas foram submetidas ao teste de resistência à tração previamente ao ensaio. Os conjuntos foram submetidos a 300.000 ciclos de simulação de movimentos mastigatórios. A perda de torque das coroas parafusadas e de todos os pilares foi analisada antes a após o ensaio. Não houve diferenças significantes para a resistência à deformação entre os pilares; para a resistência de cimentação houve diferenças significantes entre os dois pilares (p≤0,05). Para a adaptação marginal houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre os grupos G3.8P (p=0,037) e G3.8C (p≤0,05); para a comparação da adaptação das coroas entre os pilares houve diferenças antes da simulação dos ciclos mastigatórios quando comparado os grupos 3.8C com 3.8P e antes e após da simulação quando comparado os grupos 4.8C com 4.8P, para as demais comparações não houve diferença. Quanto à perda de torque nos parafusos das coroas houve diferenças significantes antes e após a simulação dos ciclos mastigatórios para ambos os pilares, quanto às comparações entre os diferentes grupos antes e após a simulação de ciclos mastigatórios houve diferença apenas após (p=0,008) a simulação. Quanto à perda de torque para os pilares houve diferenças significantes apenas para o grupo 3.8C (p≤0,05) antes e após a simulação dos ciclos mastigatórios. Considerando as limitações deste estudo, conclui-se que em relação à resistência à deformação os pilares apresentaram valores próximos; quanto a retenção das coroas, cimentadas e parafusadas, os pilares de 4.8 foram estatisticamente superiores aos pilares de 3.8; a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das coroas e em relação a perda de torque dos pilares não foram encontradas diferenças estatísticas. / Reports in the literature have stated that the bone/implant interface is extremely reliable. However, clinical limitations in relation to the prosthesis still occur. A Morse taper implant-abutment design that allows choosing between cemented or screwed crowns has been recently proposed. The abutment is presented in two different diameter sizes (conventional (ø 4.8 mm) and narrow (ø 3.8 mm). The aim of this study was to evaluate the resistance to deformation of the implant/abutment interface, the tensile strength of the cemented crowns and the effects of simulated chewing cycles on: marginal fit, crown-screw torque loss and torque loss of the two different abutments. To evaluate the resistance to deformation, 20 abutments with diameter of 4.8 and 3.8 were subjected to compressive oblique load. To evaluate the other situations, 40 implants/abutments were divided into the following groups (N = 10): G4.8P-abutment 4.8 with screwed crowns; G4.8C-abutment 4.8 with cemented crowns; G3.8P abutment 3.8 with screwed crows; G3.8C-abutment 3.8 with cemented crowns. All crowns were evaluated for marginal fit before and after simulation of the chewing cycles. The cemented crowns were subjected to tensile strength test before the simulated chewing cycles. The specimens were subjected to 300,000 cycles that simulated the chewing movements. The torque loss of the screwed crowns and all abutments were analyzed before and after the cycling tests. No significant differences were found for the deformation resistance between the abutments. No significant differences were found in the tensile strength of the cemented crowns between the two abutments (p≤0.05). The marginal fit of the crowns found no significant differences before and after the simulation of the chewing cycles between groups G3.8P (p = 0.037) and G3.8C (p≤0.05). No differences were found in crown misfit between the abutments before simulating the chewing cycles when compared between groups 3.8C 3.8P. No differences were found between groups 4.8C and 4.8P before and after the chewing simulation. Torque loss of the screwed crowns was not significantly different before and after the simulation of the chewing cycles for both abutments. Comparisons between the different groups before and after simulation found significant differences after the simulation of the chewing cycles (p = 0.008). Group 3.8C was the only group that presented significant differences (p≤0.05) before and after the simulation cycles. Within the limitations of this study, it can be concluded that the resistance to deformation between both abutments was similar. Retention of cemented and screwed crowns was statistically higher for the 4.8 abutments when compared to the 3.8 abutments. The simulation of chewing cycles significantly influenced the marginal fit of the crowns. No differences statistically significant in torque loss were found between the two abutments.
|
20 |
On the role of number of fixtures, surgical technique and timing of loading /Eliasson, Alf, January 2008 (has links)
Diss. (sammanfattning) Göteborg : Göteborgs universitet, 2008.
|
Page generated in 0.1863 seconds