11

Desenvolvimento e caracterização de um dispositivo dosimétrico para um sistema de monitoração individual externa X e gama

SANTORO, Christiana 31 January 2013 (has links)
Submitted by Amanda Silva (amanda.osilva2@ufpe.br) on 2015-03-03T14:54:17Z No. of bitstreams: 2 Tese Christiana Santoro.pdf: 3113485 bytes, checksum: a68c5a97a3d3526a4380012a9661d8b1 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-03T14:54:17Z (GMT). No. of bitstreams: 2 Tese Christiana Santoro.pdf: 3113485 bytes, checksum: a68c5a97a3d3526a4380012a9661d8b1 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013 / Há uma forte tendência na monitoração individual de estar sempre sendo envolvida com refinamentos, tais como a criação de novos procedimentos e equipamentos que sejam capazes de simular, com maior eficácia, a realidade em termos das condições radiológicas nas quais trabalhadores estão submetidos quando expostos às fontes externas de radiação ionizante, tais como fótons e partículas. Laboratórios de Calibração proporcionam uma série de condições de irradiação muito bem definidas e padronizadas que podem ser utilizadas em estudos de fenômenos físicos, baseadas nas recomendações estabelecidas por Comissões Internacionais: International Commission on Radiation Units and Measurements – ICRU; International Commission on Radiological Protection - ICRP e International Organization for Standardization – ISO. Elas estabelecem em seus relatórios, entre outros, requisitos necessários ao propósito da calibração, neste caso em especial, na atividade da monitoração individual. Entretanto, neste campo, muitas descobertas ainda podem vir a contribuir para condições radiológicas ideais e satisfatórias. Visando preencher uma dessas lacunas, um fantoma slab, simulador do tronco humano, foi utilizado neste trabalho, com o objetivo de avaliar o valor convencionalmente verdadeiro do equivalente de dose pessoal para dosímetros fotográficos, HP(d). O fantoma slab foi adaptado e nele foram construídos dois porta-dosímetros, que foram posicionados dentro do fantoma a uma profundidade de 11 mm da sua superfície frontal. A seguir, dosímetros fotográficos foram calibrados para o equivalente de dose pessoal HP(10), a uma profundidade d = 10 mm da superfície frontal, esta é a posição onde ocorre o equilíbrio eletrônico do sistema dosimétrico para radiações fortemente penetrantes. Desta forma, por meio do dispositivo dosimétrico desenvolvido neste trabalho, foi possível avaliar a dose HP(10), considerando-se a influência do espalhamento e da absorção da radiação ionizante produzidos pelo corpo humano. Pesquisadores têm concebido produtos que aprimoram a avaliação de doses às quais trabalhadores são expostos, construindo câmaras de ionização, dosímetros e tantos outros dispositivos que ofereçam uma melhor exatidão na determinação de doses e energias, aperfeiçoando a qualidade do serviço prestado à sociedade. Baseado neste cerne, comum a tantos especialistas, foi criado o dispositivo dosimétrico composto por fantoma slab com porta-dosímetros para avaliar HP(10). As curvas de calibração para o equivalente de dose pessoal, HP(10) foram obtidas a partir dos dados obtidos no experimento quando submetido a doses de 0,2 a 50 mSv de uma fonte radioativa de 60Co e de 137Cs, e de feixes de raios X, nas qualidades de radiação de espectros largos (W) e estreitos (N), descritos pela ISO 4037-1. Com uma metodologia fundamentada na programação linear foram determinadas curvas de calibração para as qualidades de radiação estudadas e, posteriormente, foi examinada a dependência energética e angular do dispositivo dosimétrico. A ISO/FDIS 4037-3 estabelece um procedimento para calibração em HP(10) onde os dosímetros devem ser posicionados sobre um fantoma slab no ponto de referência do campo de radiação ionizante, e então, utiliza-se coeficientes de conversão do kerma no ar, Ka, para HP(10). Desta forma, foram comparados os resultados dos dosímetros irradiados sobre o fantoma slab, com os resultados dos dosímetros irradiados dentro do fantoma slab. Os resultados mostraram que o comportamento dos dosímetros irradiados dentro do fantoma slab, nas baixas energias, é completamente diferente dos dosímetros irradiados sobre o fantoma slab, devido ao espalhamento. A partir deste estudo, o procedimento de irradiação de dosímetros dentro do fantoma slab pode ser caracterizado e implantado em Laboratórios de Calibração. O procedimento de irradiação com o dispositivo dosimétrico possibilitará, dentre outras aplicações, a realização de ensaios e de calibrações para fins de estudos científicos e prestação de serviços.
12

Análise da distribuição das doses ocupacionais em operações de manutenção e intervenção em áreas restritas do Centro de Radiofarmácia do IPEN / Ocupational doses distribuition analysis in operation of maintenance and interventions in restricted areas at Radiofarmacy Center of IPEN

Jessica Soares Machado 21 February 2013 (has links)
Este estudo foi desenvolvido no Instituto de Pesquisas Energéticas e Nucleares - IPEN mais especificamente, no Centro de Radiofarmácia - CR que realiza pesquisa e processamento de radiosótopos como o 99Mo, 131I, 123I, 67Ga, 201Tl, 18F, 177Lu e 153Sm para uso em medicina nuclear. Os radioisótopos são produzidos em escala industrial e a instalação foi projetada para atender aos padrões de segurança radiológica e às exigências da Garantia de qualidade. No CR há profissionais qualificados que realizam as tarefas de manutenção dos equipamentos e instrumentos, instalados nas celas de processamento de radiofármacos, sem os quais não é possível conduzir a produção com segurança e qualidade. Neste estudo foi realizada uma pesquisa denominada Pesquisa de Variáveis, baseada nas operações de manutenções e intervenções em áreas restritas do CR e no levantamento da distribuição de doses nessas tarefas no período de 2005 a 2011. Esta pesquisa tem por objetivo identificar e determinar as principais variáveis que tem impacto sobre a dose do trabalhador. Os resultados obtidos foram apresentados para variável Indivíduo Ocupacionalmente Exposto - IOE, variável Operação, variável Área/Cela, variável Tipo de Tarefa e variável Duração de Operação, em função da variável Dose. O objetivo deste trabalho foi contribuir com melhorias nas operações em áreas restritas que possam resultar em doses individuais mais baixas sem causar alterações significativas na rotina de trabalho. A análise dos resultados mostrou que a Pesquisa a Variáveis identificou os fatores que mais impactam com a dose recebida. São eles variável Operação, variável Área/Cela e variável Tipo de Tarefa. / This study was developed at IPEN - Institute of Energy and Nuclear Research more specifically in CR - Center of Radiopharmacy that conducts research and processing of radiopharmaceuticals such as 99Mo, 131I, 123I, 67Ga, 201Tl, 18F, 177Lu and 153Sm for use in nuclear medicine. The radioisotopes are produced on industrial scale and the facility was designed to meet the standards of radiation safety requirements and quality control. To ensure the production, there are qualified professionals who perform the maintenance tasks of the equipments and instruments, in the radiopharmaceuticals processing cells, to conduct the work with quality and safety. This study were based in a research called \"Search of Variables\", for the operations carried out in restricted areas of CR, taking into account the doses distribution data for these tasks, from 2005 to 2011. This research aims to identify and determine the key variables that impact on the worker\'s dose. The results were presented for the following variables: Individual occupationally exposed - IOE, operation variable, Area/Cell, Type of Task and Duration of Operation, which depend on the variable Dose. The main objective is to contribute to the improvements in operations in restricted areas that may result in lower individual doses without causing significant changes in the working routine. The results have shown the variable that most affect the dose of the workers, which are: the variable Operation, the variable Area/Cell and the variable Type of Task.
13

Análise da distribuição das doses ocupacionais em operações de manutenção e intervenção em áreas restritas do Centro de Radiofarmácia do IPEN / Ocupational doses distribuition analysis in operation of maintenance and interventions in restricted areas at Radiofarmacy Center of IPEN

Machado, Jessica Soares 21 February 2013 (has links)
Este estudo foi desenvolvido no Instituto de Pesquisas Energéticas e Nucleares - IPEN mais especificamente, no Centro de Radiofarmácia - CR que realiza pesquisa e processamento de radiosótopos como o 99Mo, 131I, 123I, 67Ga, 201Tl, 18F, 177Lu e 153Sm para uso em medicina nuclear. Os radioisótopos são produzidos em escala industrial e a instalação foi projetada para atender aos padrões de segurança radiológica e às exigências da Garantia de qualidade. No CR há profissionais qualificados que realizam as tarefas de manutenção dos equipamentos e instrumentos, instalados nas celas de processamento de radiofármacos, sem os quais não é possível conduzir a produção com segurança e qualidade. Neste estudo foi realizada uma pesquisa denominada Pesquisa de Variáveis, baseada nas operações de manutenções e intervenções em áreas restritas do CR e no levantamento da distribuição de doses nessas tarefas no período de 2005 a 2011. Esta pesquisa tem por objetivo identificar e determinar as principais variáveis que tem impacto sobre a dose do trabalhador. Os resultados obtidos foram apresentados para variável Indivíduo Ocupacionalmente Exposto - IOE, variável Operação, variável Área/Cela, variável Tipo de Tarefa e variável Duração de Operação, em função da variável Dose. O objetivo deste trabalho foi contribuir com melhorias nas operações em áreas restritas que possam resultar em doses individuais mais baixas sem causar alterações significativas na rotina de trabalho. A análise dos resultados mostrou que a Pesquisa a Variáveis identificou os fatores que mais impactam com a dose recebida. São eles variável Operação, variável Área/Cela e variável Tipo de Tarefa. / This study was developed at IPEN - Institute of Energy and Nuclear Research more specifically in CR - Center of Radiopharmacy that conducts research and processing of radiopharmaceuticals such as 99Mo, 131I, 123I, 67Ga, 201Tl, 18F, 177Lu and 153Sm for use in nuclear medicine. The radioisotopes are produced on industrial scale and the facility was designed to meet the standards of radiation safety requirements and quality control. To ensure the production, there are qualified professionals who perform the maintenance tasks of the equipments and instruments, in the radiopharmaceuticals processing cells, to conduct the work with quality and safety. This study were based in a research called \"Search of Variables\", for the operations carried out in restricted areas of CR, taking into account the doses distribution data for these tasks, from 2005 to 2011. This research aims to identify and determine the key variables that impact on the worker\'s dose. The results were presented for the following variables: Individual occupationally exposed - IOE, operation variable, Area/Cell, Type of Task and Duration of Operation, which depend on the variable Dose. The main objective is to contribute to the improvements in operations in restricted areas that may result in lower individual doses without causing significant changes in the working routine. The results have shown the variable that most affect the dose of the workers, which are: the variable Operation, the variable Area/Cell and the variable Type of Task.
14

Avaliação de dosímetros termoluminescentes empregando objetos simuladores equivalentes à água para aplicação na dosimetria de feixes clínicos de elétrons / Evaluation of thermoluminescent dosimeters using water equivalent phantoms for application in clinical electrons beams dosimetry

Bravim, Amanda 26 January 2011 (has links)
A dosimetria em Radioterapia prevê a calibração do feixe de radiação e a dosimetria de rotina para controle de qualidade, pois o seu principal objetivo é determinar, com maior precisão, a dose absorvida pelo tumor. Este trabalho tem como objetivo avaliar o comportamento de três dosímetros termoluminescentes na dosimetria de feixes clínicos de elétrons. O desempenho de detectores de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN foi comparado com o de dois dosímetros comercialmente disponíveis pela Harshaw, ambos denominados TLD-100, porém com dimensões distintas. Os dosímetros foram caracterizados com a utilização de objetos simuladores de água, água sólida RMI-457 e PMMA em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV. Também foram realizadas medidas em feixes de fótons de 6 e 15 MV (2 e 5 MeV) apenas para comparação de resultados. As curvas de dose-resposta foram obtidas para a radiação gama do 60Co no ar e em condições de equilíbrio eletrônico e para feixes clínicos de fótons e elétrons nas profundidades de máxima dose. A sensibilidade, a reprodutibilidade, a eficiência intrínseca e a dependência energética dos dosímetros termoluminescentes foram estudadas. O CaSO4:Dy apresentou comportamento semelhante ao dos TLD-100 com uma vantagem em relação à sensibilidade para os feixes e doses de radiação estudados. Sendo assim, o dosímetro produzido pelo IPEN pode ser considerado uma nova alternativa para a dosimetria nos departamentos de Radioterapia. / The dosimetry in Radiotherapy provides the calibration of the radiation beam as well as the quality control of the dose in the clinical routine. Its main objective is to determine with greater accuracy the dose absorbed by the tumor. This study aimed to evaluate the behavior of three thermoluminescent dosimeters for the clinical electron beam dosimetry. The performance of the calcium sulfate detector doped with dysprosium (CaSO4: Dy) produced by IPEN was compared with two dosimeters commercially available by Harshaw. Both are named TLD-100, however they differ in their dimensions. The dosimeters were evaluated using water, solid water (RMI-457) and PMMA phantoms in different exposure fields for 4, 6, 9, 12 and 16 MeV electron beam energies. It was also performed measurements in photon beams of 6 and 15 MV (2 and 5 MeV) only for comparison. The dose-response curves were obtained for the 60Co gamma radiation in air and under conditions of electronic equilibrium, both for clinical beam of photons and electrons in maximum dose depths. The sensitivity, reproducibility, intrinsic efficiency and energy dependence response of dosimeters were studied. The CaSO4: Dy showed the same behavior of TLD-100, demonstrating only an advantage in the sensitivity to the beams and radiation doses studied. Thus, the dosimeter produced by IPEN can be considered a new alternative for dosimetry in Radiotherapy departments.
15

Contribuição para otimização das doses individuais dos trabalhadores no processo de expedição do gerador de Tecnécio-99m / Contribution to optimization of individual doses of workers in shipment of generator technetium-99m

Fonseca, Lizandra Pereira de Souza 21 December 2009 (has links)
O Instituto de Pesquisas Energéticas e Nucleares, IPEN, pesquisa e produz radiofármacos que são distribuídos para todo o Brasil. Atualmente o radiofármaco com a maior quantidade de embalados expedidos por ano e com a maior atividade total é o gerador de tecnécio-99m. Com o intuito de diminuir as doses individuais dos trabalhadores envolvidos na produção de radiofármacos foi realizado um estudo de otimização da proteção radiológica no processo de expedição do gerador de tecnécio-99m, utilizando as técnicas de análise de custo-benefício diferencial, análise de custo-benefício integral, análise de prioridade com atributos múltiplos e análise com critérios múltiplos excedentes. Com alterações na configuração do embalado para despacho do gerador e com a aquisição de uma esteira transportadora foi possível estabelecer 4 opções de proteção. Os atributos considerados foram o custo da proteção, a dose coletiva, a dose individual e o esforço físico realizado pelo trabalhador para movimentar o embalado na falta da esteira. Para verificar a robustez das soluções analíticas encontradas com as técnicas utilizadas na otimização foi realizado um estudo de sensibilidade e foi constatado que a opção 3 é mais robusta que a opção 1, que deixa de ser a solução analítica com um aumento de R$ 20.000,00 no custo da proteção. / The Instituto de Pesquisas Energéticas e Nucleares, IPEN, radiopharmaceuticals research and produce that are distributed throughout Brazil, currently the radiopharmaceutical with the largest number of packaged shipped per year and with the highest total activity is the 99m technetium generator. To reduce individual doses for workers involved in the production of radiopharmaceuticals was performed a study of radiological protection optimization in the shipment process of technetium generator, using the techniques: diferencial cost-benefit analysis, integral cost-benefit analysis, multi-attribute utility analysis and multi-criteria outranking analysis. With changes in the configuration of packed for generator dispatch and with the acquirement of a mat transporter it was possible establish 4 protection options. The attributes considered were the protection cost, collective dose, individual dose and physical effort by worker to move the package without the mat. To assess the robustness of analytical solutions found with the techniques used in the optimization we performed a sensitivity study and found that option 3 is more robust than option 1, which is no longer the analytical solution with an increase of R$ 20.000,00 the cost of protection.
16

Avaliação da resposta de detectores termoluminescentes na dosimetria de feixes clínicos utilizando diferentes objetos simuladores / Response evaluation of thermoluminescent detectors in clinical beams dosimetry using different phantoms

Matsushima, Luciana Cardoso 23 August 2010 (has links)
A radioterapia é uma das três principais modalidades de tratamento utilizadas no tratamento de doenças malignas, como o câncer; as duas outras são a quimioterapia e a radiocirurgia. Em contraste com outras especialidades médicas que necessitam principalmente de conhecimento clínico e da experiência de especialistas, a radioterapia, com o uso da radiação ionizante no tratamento do câncer, necessita de grandes investimentos em tecnologias modernas e do esforço colaborativo de diversos profissionais que contribuem para o sucesso do tratamento. Na área de dosimetria clínica, uma calibração eficiente e precisa do feixe de radiação garante o conhecimento da dose fornecida ao paciente, assegurando, portanto, o sucesso do tratamento radioterápico. Este trabalho tem por objetivo o estudo comparativo da resposta termoluminescente dos dosímetros de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN (6 mm de diâmetro e 0,8 mm de espessura) com a resposta dos dosímetros de fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti com 3,15 x 3,15 x 0,9 mm3) na dosimetria de feixes clínicos de fótons (6 e 15 MV) e elétrons (6 e 9 MeV) utilizando objetos simuladores de água sólida (RMI-457), água e PMMA. Foram obtidas as curvas de dose-resposta para a radiação gama do cobalto-60 (60Co) no ar e em condições de equilíbrio eletrônico (placa de PMMA), e para elétrons e fótons clínicos nas profundidades de dose máxima. Foi avaliada também a sensibilidade dos dosímetros termoluminescentes e determinada a reprodutibilidade da resposta e a eficiência intrínseca para os diferentes tipos de simuladores e energias de radiação estudadas. Os resultados obtidos indicam que a principal vantagem do dosímetro de CaSO4:Dy é a sua maior sensibilidade para as doses de radiação avaliadas para os feixes do 60Co, fótons e elétrons, representando, portanto, uma alternativa viável para a aplicação em dosimetria nos setores de radioterapia. / Radiotherapy is one of the three principal treatment modalities used in the treatment of malignant diseases such as cancer, the other two are chemotherapy and radiosurgery. In contrast to other medical specialties that rely mainly on the clinical knowledge and experience of medical specialists, radiotherapy, with its use of ionizing radiation in treatment of cancer, relies heavily on modern technology and the collaborative efforts of several professionals whose coordinated team approach greatly influences the outcome of the treatment. In the area of clinical dosimetry, an efficient and accurate calibration of the radiation beam ensures knowledge of the radiation dose delivered to the patient, allowing thus the success of radiotherapy. This study aims to compare the thermoluminescent response of calcium sulphate doped with dysprosium (CaSO4:Dy) dosimeters produced by IPEN (6 mm in diameter and 0,8 mm tick) with the response of lithium fluoride (3,15 x 3,15 x 0,9 mm3) doped with magnesium and titanium (LiF:Mg,Ti) in dosimetry of clinical photons (6 and 15 MV) and electrons beams (6 and 9 MeV) using solid water (RMI-457), water and PMMA phantoms. Initially, the dose-response curves were obtained for irradiation in cobalt-60 gamma radiation source in air (PMMA plates) and under electronic equilibrium conditions and for clinical electrons and photons beams at depth of maximum dose. The sensitivities of the thermoluminescent dosimeters were also evaluated and the values of their reproducibilities and intrinsic efficiency were determined for the response to differents types of phantoms and radiation energy. The obtained results indicate that the main advantage of CaSO4:Dy dosimeters is the enhanced sensitivity to radiation doses measured for 60Co, photons and electrons beams, thus representing a viable alternative for application in dosimetry in the radiotherapy area.
17

Risco de exposição à radiação ionizante em crianças e adolescentes participantes de um programa de controle da asma em comparação à população geral / Exposure risk to ionizing radiation in children and adolescents participating in an asthma control program compared to the general population

Letícia Guimarães Carvalho de Souza Lima 09 June 2017 (has links)
Asma é uma doença de elevada prevalência e morbidade, constituindo-se um importante problema de saúde pública em todo o mundo. Muitos diagnósticos médicos por imagem dependem da utilização de raio X; entretanto, no caso da asma, o diagnóstico é clínico, particularmente na criança. Os pacientes são frequentemente submetidos a procedimentos radiológicos, preferencialmente o raio X de tórax. A escassez de dados na literatura referentes aos riscos da exposição à radiação ionizante em pacientes com asma e os possíveis benefícios relacionados à oportunidade de coleta de informações justificaram a investigação no programa municipal infantil de controle da asma de Ipatinga, Minas Gerais (Programa Respirar). Foi realizado estudo retrospectivo referente ao ano de 2014, com caso controle, do qual participaram 363 pacientes do Programa Respirar e número semelhante de controle, sem diferença sociodemográfica significativa entre os grupos. Encontramos que uma criança do grupo respirar tem 1,59 vez mais chance de realizar um raio X, e para o raio X de tórax essa chance aumenta para 6,56 vezes. A maioria dos raios X de tórax foi solicitada nas visitas aos serviços de urgência, mas 90% dos raios X realizados e laudados no grupo respirar e 84,2% do grupo controle revelaram resultado normal ou com alterações típicas, possibilitando o questionamento a respeito da indicação do exame. / Asthma is a disease of high prevalence and morbidity, constituting an important public health problem throughout the world. Patients are often submitted to radiological procedures, preferably the chest X ray. Many medical imaging diagnoses depend on the use of X ray, however, in the case of asthma, the diagnosis is clinical, particularly in the child. The scarcity of data in the literature regarding the risks of exposure to ionizing radiation in patients with asthma and the possible benefits related to the opportunity to collect information justified the investigation in the municipal infant asthma control program in Ipatinga, Minas Gerais (Programa Respirar). A retrospective study was carried out for the year 2014, with a control case involving 363 patients from the Programa Respirar and a similar number of controls, with no significant sociodemographic difference between the groups. We found that a child in the group respirar is 1.59 time more likely to have an X ray and for the chest X ray this chance increases to 6.56 times. The majority of chest X rays were requested at emergency department visits, but 90% of the X rays performed and lauded in the Programa Respirar and 84.2% of the control group revealed normal results or with typical alterations, making it possible to question the indication of the examination.
18

Controle de dose em transporte rodoviário de material radioativo / Dose control in road transport of radioactive material

Eduardo Gerulis 05 December 2013 (has links)
As doses de radiação ionizante para os trabalhadores no transporte de material radioativo devem ser tão pequenas quanto razoavelmente exequível. As doses médias dos motoristas e carregadores amostrados neste trabalho devem ser diminuídas. A demonstração do controle das doses em veículo rodoviário com material radioativo, requisitada pelo regulamento brasileiro atual, norma CNEN NE 5.01, é apresentada em formulário próprio com valores de exposição obtidos em posições de ocupação regular de indivíduos do público e de trabalhadores, mesmo quando se expede veículo sem a necessidade de uso exclusivo (∑ IT 50). Este trabalho mostra, por meio de pesquisa bibliográfica, elaboração de modelos e pesquisa de campo, que esta demonstração do controle com a obtenção dos valores de exposição nesta situação, para um método de controle melhor, deve ser realizada pela apresentação do registro do acúmulo de cargas, limitado (∑ IT 50), a fim de evitar a obtenção destas medidas, para que haja padronização com regulamentos estrangeiros e para que os custos e os tempos, importantes para expedição de radiofármacos com meia-vida curta, e também as atuais doses laborais dos técnicos de radioproteção sejam todos diminuídos. Os valores de exposição dos parâmetros utilizados com esse método são menores do que seus limites regulamentares. Para contribuir com essas finalidades devem ser apresentadas pelo regulamento brasileiro atualizado as distâncias de segregação entre as cargas e as cabines dos veículos. / The radiation doses to workers in the transport of radioactive material should be as low as reasonably achievable. The average doses of drivers and loaders, sampled in this thesis should be decreased. The demonstration of doses control in a road vehicle with radioactive material required by the current Brazilian regulation, CNEN NE 5.01 should be written in its own printed form with exposure values obtained in normally occupied positions from workers and members of the public, even when the consignment does not need \"exclusive use\" (∑ IT 50). Through bibliographic research, modeling and field research, this research work shows that this demonstration of the control should be done by writing the registration accumulation of load, limited (∑ IT 50), also in the own printed form. It is for a better control method, in order to avoid the use of measuring equipment, to build standardization with foreign regulations, to the current occupational doses of radioprotection technicians, the costs and time, (important for consignment with radiopharmaceuticals short half-life) would be all smaller. Exposure values of the parameters used with this method are smaller than regulatory limits. The segregation distances between loads and the cabins of vehicles shall be showed by Brazilian regulation updated to contribute to these aims.
19

Avaliação das doses resultantes de procedimentos radiodiagnósticos realizados em medicina veterinária e avaliação das doses secundárias de radiação espalhada no corpo clínico e nos proprietários dos animais / Evaluation of doses from radiodiagnotic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners

Glauco Rogério Veneziani 25 March 2013 (has links)
O objetivo primordial em radiologia veterinária é a produção de radiografias com qualidade diagnóstica, em uma primeira tentativa. Esse objetivo deve atender a três propósitos: (1) diminuir a exposição à radiação do paciente e trabalhadores; (2) diminuir o custo do estudo para o cliente e (3) produzir dados diagnósticos para rápida interpretação e tratamento do paciente. Esse trabalho teve por objetivo a determinação das doses em cães submetidos a radiografias de tórax e abdômen utilizando a técnica da dosimetria termoluminescente (TL). As doses de radiação foram avaliadas com a utilização de dosímetros termoluminescentes de sulfato de cálcio dopado com disprósio (CaSO4:Dy) e fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti). Os resultados obtidos indicam que é extremamente importante a avaliação das doses de radiação envolvidas em procedimentos diagnósticos de radiologia veterinária, para a avaliação das doses nos animais e para ser usado como um parâmetro para a monitoração individual dos proprietários de animais, que auxiliam no posicionamento, e para a proteção dos trabalhadores ocupacionalmente expostos nas Clínicas de Radiologia Veterinária. / The primary goal in veterinary radiography is to produce radiographs of diagnostic quality on the first attempt. This goal serves three purposes: (1) to decrease radiation exposure to the patient and veterinary personnel; (2) to decrease the cost of the study for the client; and (3) to produce diagnostic data for rapid interpretation and treatment of the patient. This work aimed to determine the doses in dogs submitted to chest and abdomen Xrays using the technique of thermoluminescence (TL) dosimetry. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) and lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti). The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pets owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics.
20

Risco de exposição à radiação ionizante em crianças e adolescentes participantes de um programa de controle da asma em comparação à população geral / Exposure risk to ionizing radiation in children and adolescents participating in an asthma control program compared to the general population

Lima, Letícia Guimarães Carvalho de Souza 09 June 2017 (has links)
Asma é uma doença de elevada prevalência e morbidade, constituindo-se um importante problema de saúde pública em todo o mundo. Muitos diagnósticos médicos por imagem dependem da utilização de raio X; entretanto, no caso da asma, o diagnóstico é clínico, particularmente na criança. Os pacientes são frequentemente submetidos a procedimentos radiológicos, preferencialmente o raio X de tórax. A escassez de dados na literatura referentes aos riscos da exposição à radiação ionizante em pacientes com asma e os possíveis benefícios relacionados à oportunidade de coleta de informações justificaram a investigação no programa municipal infantil de controle da asma de Ipatinga, Minas Gerais (Programa Respirar). Foi realizado estudo retrospectivo referente ao ano de 2014, com caso controle, do qual participaram 363 pacientes do Programa Respirar e número semelhante de controle, sem diferença sociodemográfica significativa entre os grupos. Encontramos que uma criança do grupo respirar tem 1,59 vez mais chance de realizar um raio X, e para o raio X de tórax essa chance aumenta para 6,56 vezes. A maioria dos raios X de tórax foi solicitada nas visitas aos serviços de urgência, mas 90% dos raios X realizados e laudados no grupo respirar e 84,2% do grupo controle revelaram resultado normal ou com alterações típicas, possibilitando o questionamento a respeito da indicação do exame. / Asthma is a disease of high prevalence and morbidity, constituting an important public health problem throughout the world. Patients are often submitted to radiological procedures, preferably the chest X ray. Many medical imaging diagnoses depend on the use of X ray, however, in the case of asthma, the diagnosis is clinical, particularly in the child. The scarcity of data in the literature regarding the risks of exposure to ionizing radiation in patients with asthma and the possible benefits related to the opportunity to collect information justified the investigation in the municipal infant asthma control program in Ipatinga, Minas Gerais (Programa Respirar). A retrospective study was carried out for the year 2014, with a control case involving 363 patients from the Programa Respirar and a similar number of controls, with no significant sociodemographic difference between the groups. We found that a child in the group respirar is 1.59 time more likely to have an X ray and for the chest X ray this chance increases to 6.56 times. The majority of chest X rays were requested at emergency department visits, but 90% of the X rays performed and lauded in the Programa Respirar and 84.2% of the control group revealed normal results or with typical alterations, making it possible to question the indication of the examination.