• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 81
  • 20
  • 10
  • 8
  • 6
  • 4
  • 1
  • 1
  • Tagged with
  • 204
  • 204
  • 204
  • 204
  • 142
  • 72
  • 29
  • 27
  • 24
  • 24
  • 24
  • 23
  • 23
  • 23
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Preparacao e caracterizacao de eletrocatalisadores Pt-terras raras/C para celulas a combustivel do tipo PEMFC / Preparation and characterization of Pt-rare earth/C electrocatalysts for PEM fuel cells

SANTORO, THAIS A. de B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:22Z (GMT). No. of bitstreams: 0 / Os eletrocatalisadores Pt/C e Pt-Terras Raras/C (terras raras = La, Ce, Pr, Nd, Sm, Tb, Dy, Ho, Er, Tm, and Lu) foram preparados (20% em massa e razão atômica Pt-TR de 50:50) pelo método de redução por álcool, usando H2PtCl6.6H2O (Aldrich) e Terras Raras Cl3.xH2O (Aldrich) como fonte de metais, etileno glicol como solvente e agente redutor e, o carbono Vulcan XC72, como suporte. Os catalisadores foram caracterizados por espectroscopia de energia dispersiva de raios X (EDX), análises de difração de raios X (DRX) e microscopia de transmissão eletrônica (TEM). As análises por EDX mostraram que as razões atômicas dos diferentes eletrocatalisadores Pt-TR/C preparados foram similares às composições nominais de partida. Em todos os difratogramas, observa-se um pico largo em aproximadamente 2 = 25o o qual foi associado ao suporte de carbono Vulcan XC72 e quatro outros picos de difração em aproximadamente 2 = 40o, 47o, 67o e 82o os quais são associados aos planos (111), (200), (220) e (311), respectivamente, da estrutura cúbica de face centrada (CFC) de platina e suas ligas. Para os eletrocatalisadores Pt-TR/C também foram observadas fases nos difratogramas de raios X referentes aos óxidos de terras raras. Foram preparados eletrocatalisadores Pt-La/C com diferentes razões atômicas. Micrografias de transmissão eletrônica apresentaram uma razoável distribuição das partículas de Pt no suporte de carbono com algumas aglomerações, o que está de acordo com os resultados de difração de raios X. O desempenho para a oxidação de CO, metanol e etanol foi investigada através de voltametria cíclica, cronoamperometria e espectroscopia no infravermelho com transformada de Fourier. A atividade eletrocatalítica dos eletrocatalisadores Pt-TR/C, em especial PtLa/C, foram maiores que do Pt/C. A investigação por espectroscopia no infravermelho com transformada de Fourier para a oxidação de etanol com os eletrocatalisadores PtLa/C mostrou que o acetoaldeído e o ácido acético foram os principais produtos formados. O eletrocatalisador PtLa/C (30:70) apresentou melhores resultados para a reação de redução de oxigênio, oxidação de metanol e etanol, e a temperaturas superiores a 30°C para oxidação de monóxido de carbono. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
192

Estudo da oxidação eletroquímica do ácido fórmico utilizando eletrocatalisadores Pd/C-Sb2O5.SnO2, PdAu/C-Sb2O5.SnO2, PdIr/C-Sb2O5.SnO2 e PdAulr/C-Sb2O5.SnO2 preparados via redução por borohidreto de sódio / Electro-oxidation study of formic acid using Pd/C-Sb2O5•SnO2, PdAu/C-Sb2O5•SnO2, PdIr/C-Sb2O5•SnO2 and PdAuIr/C-Sb2O5•SnO2 electrocatalysts prepared by sodium borohydride reduction

NANDENHA, JÚLIO 11 November 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-11-11T12:52:46Z No. of bitstreams: 0 / Made available in DSpace on 2016-11-11T12:52:46Z (GMT). No. of bitstreams: 0 / Os eletrocatalisadores Pd/C, Pd/C-15%ATO, PdAu/C-15%ATO (90:10, 70:30 e 50:50), PdIr/C-15%ATO (90:10, 70:30 e 50:50) e PdAuIr/C-15%ATO (90:5:5, 70:20:10 e 50:45:5) foram preparados pelo método de redução por borohidreto de sódio. Esses eletrocatalisadores foram caracterizados por espectroscopia de energia dispersiva de raios X (EDX), difração de raios X (DRX) e microscopia eletrônica de transmissão (MET), enquanto que as atividades eletrocatalíticas para a oxidação eletroquímica do ácido fórmico em meios ácido e alcalino foram investigadas por voltametria cíclica, cronoamperometria e experimentos em células a combustível de ácido fórmico direto (DFAFC) em meios ácido e alcalino a 100 ºC e 60 ºC, respectivamente. Os difratogramas de raios X dos eletrocatalisadores PdAu/C-15%ATO, PdIr/C-15%ATO e PdAuIr/C-15%ATO mostraram a presença de fase de estrutura cúbica de Pd (cfc), ligas de Pd-Au, Pd-Ir e Pd-Au-Ir, fases de carbono e SnO2. As micrografias eletrônicas de transmissão indicaram que as nanopartículas foram bem distribuídas sobre o suporte C-ATO e apresentaram alguns aglomerados. Os estudos eletroquímicos para oxidação de ácido fórmico foram realizados utilizando a técnica de camada fina porosa. Todos os eletrocatalisadores preparados foram testados em células a combustível unitárias alimentadas diretamente por ácido fórmico. Nos estudos comparativos entre os melhores eletrocatalisadores, o eletrocatalisador PdAuIr/C-15%ATO (50:45:5) em meios ácido e alcalino apresentou uma atividade eletrocatalítica superior para a oxidação eletroquímica do ácido fórmico em temperatura ambiente em comparação com o eletrocatalisador Pd/C-15%ATO e os outros eletrocatalisadores binários e ternários preparados. Os experimentos em uma DFAFC unitária ácida e alcalina, também, indicaram que o eletrocatalisador PdAuIr/C-15%ATO (90:5:5) apresentou melhor desempenho para oxidação eletroquímica do ácido fórmico a 100 ºC (meio ácido) e a 60 ºC (meio alcalino), respectivamente, em comparação com os demais eletrocatalisadores sintetizados. Esses resultados indicaram que a adição de Au e Ir ao Pd favorece a oxidação eletroquímica do ácido fórmico, esse efeito pode ser atribuído ao mecanismo bifuncional (a presença de ATO (Sb2O5·SnO2), óxidos de Au e Ir) associados ao efeito eletrônico (ligas de Pd-Au-Ir (cfc)). / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
193

Etude de l'influence des protons sur la réduction de l'oxygène dans des couches catalytiques ordonnées en vue d'une application en pile à combustible / Study of the influence of protons on the oxygen reduction in ordered catalytic layers for fuel cell applications

Rouhet, Marlene 16 September 2014 (has links)
Les couches catalytiques avec une structure ordonnée à base de nanoparticules de Pt supportées sur des nanofilaments de carbone verticalement alignés ont montré des performances intéressantes grâce à l’amélioration des propriétés du transport de matière et à une meilleure utilisation du Pt. Des études électrochimiques combinées à une modélisation mathématique ont mis en évidence l’influence du transport de protons sur les processus d’oxydo-réduction, la cinétique et le mécanisme de réduction de l’O2 (ORR), et sur H2O2 qui s’échappe des couches pendant l’ORR. Nous avons montré que (i) les protons sont impliqués dans l’étape limitante de la réaction, (ii) pour un pH ≥ 3, un plateau de courant limité par la diffusion des protons est observé et, (iii) pour un pH ≥ 3, le mécanisme de l’ORR implique non seulement les ions hydroniums mais aussi les molécules d’eau. L’intégration de ces couches catalytiques dans des PEMFCs haute température a ensuite été étudiée. Les performances obtenues sont légèrement plus basses que celles des couches conventionnelles. Un travail d’optimisation reste donc à accomplir pour améliorer les performances. / Ordered catalytic layers based on vertically aligned carbon nanofilaments with Pt nanoparticles demonstrate high efficiency for oxygen transport and Pt utilization in the catalytic layer. Electrochemical studies combined with mathematical modeling confirm the influence of the proton transport on surface red-ox processes, the kinetics and the mechanism of the O2 reduction (ORR), and on the H2O2 escape. We show that (i) protons are involved in the rate-determining step of the O2 reduction, (ii) for pH ≥ 3, a plateau corresponding to the diffusion-limited current of protons is observed and, (iii) for pH ≥ 3, the mechanism of the ORR involves not only the hydronium ions but also water molecules. The integration of these catalytic layers in high temperature PEMFCs was then studied. The performance is slightly lower than that for conventional layers. An optimization work is required to improve the performance.
194

Comportement local et performances électriques d'une pile à combustible à membrane : vers un outil de diagnostic / Proton exchange membrane fuel cell local behavior and electric performances : basis to a diagnosis tool

Chupin, Sylvain 11 December 2009 (has links)
Le travail de thèse présenté ici apporte des éléments de compréhension sur l'influence de la gestion de l'eau et de la gestion thermique d'une PEMFC sur ses performances électriques. Un modèle bidimensionnel représentant les transferts de matière et de chaleur dans l'épaisseur d'une cellule élémentaire et le long des canaux d'alimentation est mis en place. Une partie spécifique de l'étude concerne la modélisation microscopique des agglomérats réactionnels et l'influence de l'eau présente dans ces zones actives sur les performances électriques locales et globales de la pile. Dans l'optique de réaliser un modèle pouvant s'intégrer à un système de contrôle, les transports couplés de l'eau liquide et vapeur, de la chaleur et des charges sont résolus analytiquement. Quelles que soient les conditions de fonctionnement, le modèle permet de calculer quel est l'état interne de la pile en terme d'hydratation, de production de courant et de chaleur. Le diagnostic de l'état interne de la pile en fonction des conditions opératoires permet de connaître précisément comment adapter les paramètres d'alimentation de la pile pour obtenir des performances électriques optimales. Les distributions locales d'eau, de courant et de température sont présentées en fonction de la stratégie d'alimentation en gaz de la pile et de l'orientation du circuit de régulation thermique. Une partie consacrée au diagnostic de fonctionnement d'une pile illustre en quoi l'utilisation du modèle et la connaissance de l'état interne de la pile apporte des informations primordiales lors de l'utilisation d'une pile à combustible / The present work contributes to the understanding of water management and thermal management of a PEM fuel cell influences on the electrical performances. A bidimensional model representing mass and heat transfer in the cell thickness and along distribution channels is done. A specific part of the study concerns a microscopic representation of reactive agglomerates. This part presents the impact of the liquid water presence on local and global current densities. In te vein of integrating this model in a total fuel cell control system, simplifications have been done and coupled mass, heat and charge transfers are solved analytically. For any operating condition, the model gives a complete view of the hydric, thermal and electric inner situation of the cell. This diagnosis of the inner state of the cell leads to find the operating conditions giving to the optimal electric performances. Water, current and temperature distributions are presenting for different gas feeding strategies and different thermal management configurations. A specific part is dedicated to illustrate how this local diagnosis of the cell state can be used to estimate its global electric performances
195

Kinetic Studies and Electrochemical Processes at Fuel Cell Electrodes

Stuckey, Philip A. January 2011 (has links)
No description available.
196

Experimental Studies on the Mechanical Durability of Proton Exchange Membranes

Li, Yongqiang 28 December 2008 (has links)
Three testing methods are proposed to characterize properties of fuel cell materials that affect the mechanical durability of proton exchange membranes (PEMs). The first two methods involved measuring the in-plane biaxial strength of PEMs and the biaxial hygrothermal stresses that occur in PEMs during hygrothermal cycles. The third method investigated the nonuniform thickness and compressibility of gas diffusion media which can lead to concentrated compressive stresses in the PEM in the through-plane direction. Fatigue and creep to leak tests using multi-cell pressure-loaded blister fixtures were conducted to obtain the lifetimes of PEMs before reaching a threshold value of gas leakage. These tests are believed to be more relevant than quasi-static uniaxial tensile to rupture tests because of the introduction of biaxial cyclic and sustained loading and the use of gas leakage as the failure criterion. They also have advantages over relative humidity cycling test because of the controllable mechanical loading. Nafion® NRE-211 membrane was tested at three different temperatures and the time-temperature superposition principle was used to construct a stress-lifetime master curve. Tested at 90°C, extruded Ion Power® N111-IP membrane was found to have longer lifetime than Gore™-Select® 57 and Nafion NRE-211 membranes under the same blister pressure profiles. Bimaterial specimens fabricated by bonding a piece of PEM to a substrate material were used to measure the hygral stresses, compressive and tensile, in the PEM during relative humidity cycles. The substrate material and its thickness were carefully chosen so that stresses in the PEM could be obtained directly from the curvature of the bimaterial specimen without knowing the constitutive properties of the PEM. Three commercial PEMs were tested at 80°C by cycling the relative humidity between 90% and 0% and by drying the membrane to 0%RH after submersion in liquid water. Stress histories for all three membranes show strong time-dependencies and Nafion® NRE-211 exhibited the largest tensile stress upon drying. Besides in-plane stresses, hard spots in gas diffusion media (GDM) can locally overcompress PEMs in the out-of-plane direction and cause electrical shorting. In this study, GDM samples sealed with an impermeable Kapton® film on the surface were compressed with uniform air pressure and the nonuniform displacement field was measured with a three-dimensional digital image correlation technique. Hard spots as a result of the nonuniform thickness and compressibility of the GDM were found and their severities as stress risers are evident. Locally, a nominal platen compression (similar to bipolar plate land compression) of 0.68 MPa can lead to compressive stress as large as 2.30 MPa in various hard spots that are in the order of 100s µm to 1 mm in size. / Ph. D.
197

Contribution au pronostic de durée de vie des systèmes piles à combustible PEMFC / Contribution to lifetime prognostics for proton exchange membrane fuel cell (PEMFC) systems

Silva Sanchez, Rosa Elvira 21 May 2015 (has links)
Les travaux de cette thèse visent à apporter des éléments de solutions au problème de la durée de vie des systèmes pile à combustible (FCS – Fuel Cell System) de type à « membrane échangeuse de protons » (PEM – Proton Exchange Membrane) et se décline sur deux champs disciplinaires complémentaires :Une première approche vise à augmenter la durée de vie de celle-ci par la conception et la mise en œuvre d'une architecture de pronostic et de gestion de l'état de santé (PHM – Prognostics & Health Management). Les PEM-FCS, de par leur technologie, sont par essence des systèmes multi-physiques (électriques, fluidiques, électrochimiques, thermiques, mécaniques, etc.) et multi-échelles (de temps et d'espace) dont les comportements sont difficilement appréhendables. La nature non linéaire des phénomènes, le caractère réversible ou non des dégradations, et les interactions entre composants rendent effectivement difficile une étape de modélisation des défaillances. De plus, le manque d'homogénéité (actuel) dans le processus de fabrication rend difficile la caractérisation statistique de leur comportement. Le déploiement d'une solution PHM permettrait en effet d'anticiper et d'éviter les défaillances, d'évaluer l'état de santé, d'estimer le temps de vie résiduel du système, et finalement, d'envisager des actions de maîtrise (contrôle et/ou maintenance) pour assurer la continuité de fonctionnement. Une deuxième approche propose d'avoir recours à une hybridation passive de la PEMFC avec des super-condensateurs (UC – Ultra Capacitor) de façon à faire fonctionner la pile au plus proche de ses conditions opératoires optimales et ainsi, à minimiser l'impact du vieillissement. Les UCs apparaissent comme une source complémentaire à la PEMFC en raison de leur forte densité de puissance, de leur capacité de charge/décharge rapide, de leur réversibilité et de leur grande durée de vie. Si l'on prend l'exemple des véhicules à pile à combustible, l'association entre une PEMFC et des UCs peut être réalisée en utilisant un système hybride de type actif ou passif. Le comportement global du système dépend à la fois du choix de l'architecture et du positionnement de ces éléments en lien avec la charge électrique. Aujourd'hui, les recherches dans ce domaine se focalisent essentiellement sur la gestion d'énergie entre les sources et stockeurs embarqués ; et sur la définition et l'optimisation d'une interface électronique de puissance destinée à conditionner le flux d'énergie entre eux. Cependant, la présence de convertisseurs statiques augmente les sources de défaillances et pannes (défaillance des interrupteurs du convertisseur statique lui-même, impact des oscillations de courant haute fréquence sur le vieillissement de la pile), et augmente également les pertes énergétiques du système complet (même si le rendement du convertisseur statique est élevé, il dégrade néanmoins le bilan global). / This thesis work aims to provide solutions for the limited lifetime of Proton Exchange Membrane Fuel Cell Systems (PEM-FCS) based on two complementary disciplines:A first approach consists in increasing the lifetime of the PEM-FCS by designing and implementing a Prognostics & Health Management (PHM) architecture. The PEM-FCS are essentially multi-physical systems (electrical, fluid, electrochemical, thermal, mechanical, etc.) and multi-scale (time and space), thus its behaviors are hardly understandable. The nonlinear nature of phenomena, the reversibility or not of degradations and the interactions between components makes it quite difficult to have a failure modeling stage. Moreover, the lack of homogeneity (actual) in the manufacturing process makes it difficult for statistical characterization of their behavior. The deployment of a PHM solution would indeed anticipate and avoid failures, assess the state of health, estimate the Remaining Useful Lifetime (RUL) of the system and finally consider control actions (control and/or maintenance) to ensure operation continuity.A second approach proposes to use a passive hybridization of the PEMFC with Ultra Capacitors (UC) to operate the fuel cell closer to its optimum operating conditions and thereby minimize the impact of aging. The UC appear as an additional source to the PEMFC due to their high power density, their capacity to charge/discharge rapidly, their reversibility and their long life. If we take the example of fuel cell hybrid electrical vehicles, the association between a PEMFC and UC can be performed using a hybrid of active or passive type system. The overall behavior of the system depends on both, the choice of the architecture and the positioning of these elements in connection with the electric charge. Today, research in this area focuses mainly on energy management between the sources and embedded storage and the definition and optimization of a power electronic interface designated to adjust the flow of energy between them. However, the presence of power converters increases the source of faults and failures (failure of the switches of the power converter and the impact of high frequency current oscillations on the aging of the PEMFC), and also increases the energy losses of the entire system (even if the performance of the power converter is high, it nevertheless degrades the overall system).
198

Diagnostic et Pronostic de Systèmes Dynamiques Incertains dans un contexte Bond Graph / Diagnostics and Prognostics of Uncertain Dynamical Systems in a Bond Graph Framework

Jha, Mayank Shekhar 08 December 2015 (has links)
Cette thèse développe des approches pour le diagnostic et le pronostic de systèmes dynamiques incertains en utilisant la technique de modélisation Bond Graph (BG). Tout d'abord, une représentation par intervalles des incertitudes paramétriques et de mesures est intégrée à un modèle BG-LFT (Linear Fractional Transformation). Une méthode de détection robuste de défaut est développée en utilisant les règles de l'arithmétique d'intervalle pour la génération de seuils robustes et adaptatifs sur les résidus nominaux. La méthode est validée en temps réel sur un système de générateur de vapeur.Deuxièmement, une nouvelle méthodologie de pronostic hybride est développée en utilisant les Relations de Redondance Analytique déduites d'un modèle BG et les Filtres Particulaires. Une estimation de l'état courant du paramètre candidat pour le pronostic est obtenue en termes probabilistes. La prédiction de la durée de vie résiduelle est atteinte en termes probabilistes. Les incertitudes associées aux mesures bruitées, les conditions environnementales, etc. sont gérées efficacement. La méthode est validée en temps réel sur un système mécatronique incertain.Enfin, la méthodologie de pronostic développée est mise en œuvre et validée pour le suivi efficace de la santé d'un sous-système électrochimique d’une pile à combustible à membrane échangeuse de protons (PEMFC) industrielle à l’aide de données de dégradation réelles. / This thesis develops the approaches for diagnostics and prognostics of uncertain dynamic systems in Bond Graph (BG) modeling framework. Firstly, properties of Interval Arithmetic (IA) and BG in Linear Fractional Transformation, are integrated for representation of parametric and measurement uncertainties on an uncertain BG model. Robust fault detection methodology is developed by utilizing the rules of IA for the generation of adaptive interval valued thresholds over the nominal residuals. The method is validated in real time on an uncertain and highly complex steam generator system.Secondly, a novel hybrid prognostic methodology is developed using BG derived Analytical Redundancy Relationships and Particle Filtering algorithms. Estimations of the current state of health of a system parameter and the associated hidden parameters are achieved in probabilistic terms. Prediction of the Remaining Useful Life (RUL) of the system parameter is also achieved in probabilistic terms. The associated uncertainties arising out of noisy measurements, environmental conditions etc. are effectively managed to produce a reliable prediction of RUL with suitable confidence bounds. The method is validated in real time on an uncertain mechatronic system.Thirdly, the prognostic methodology is validated and implemented on the electrical electro-chemical subsystem of an industrial Proton Exchange Membrane Fuel Cell. A BG of the latter is utilized which is suited for diagnostics and prognostics. The hybrid prognostic methodology is validated, involving real degradation data sets.
199

Electrocatalyseurs à base d’oxydes métalliques poreux pour pile à combustible à membrane échangeuse de protons / Porous metal oxide-based electrocatalysts for proton exchange membrane fuel cells

Cognard, Gwenn 28 March 2017 (has links)
Les électrocatalyseurs conventionnels utilisés dans les piles à combustibles à membrane échangeuse de protons (PEMFC) sont composés de nanoparticules de platine supportées sur des noirs de carbone de forte surface spécifique. A la cathode de la PEMFC, siège de la réaction de réduction de l’oxygène (ORR), le potentiel électrochimique peut atteindre des valeurs élevées - notamment lors de phases arrêt-démarrage - engendrant des dégradations irréversibles du support carboné. Une solution « matériaux » consiste à remplacer ce dernier par des supports à base d’oxydes métalliques. Ceux-ci doivent être résistants à la corrosion électrochimique, conducteurs électroniques et posséder une structure poreuse et nano-architecturée (permettant le transport des réactifs et produits et une distribution homogène de l’ionomère et des nanoparticules de platine). Dans ce travail, nous avons donc élaboré et caractérisé des électrocatalyseurs à base de nanoparticules de platine (Pt) déposées sur du dioxyde d’étain (SnO₂) et de titane (TiO₂) texturés (morphologies aérogel, nanofibres ou « loosetubes ») et conducteurs électroniques (dopés au niobium Nb ou à l’antimoine Sb). Le support permettant d’atteindre les meilleures propriétés électrocatalytiques est un aérogel de SnO₂ dopé à l’antimoine, noté ATO. En particulier, l’électrocatalyseur Pt/ATO présente une activité spécifique vis-à-vis de l’ORR supérieure à celle d’un électrocatalyseur Pt/carbone Vulcan® synthétisé dans les mêmes conditions, suggérant des interactions bénéfiques entre les nanoparticules de Pt et le support oxyde métallique (Strong Metal Support Interactions, SMSI).Des tests de durabilité simulant le fonctionnement d’une PEMFC en conditions automobile ont été effectués en électrolyte liquide à 80 °C sur ces deux électrocatalyseurs : cyclage entre 0,60 et 1,00 V vs l’électrode réversible à hydrogène (RHE) ou entre 1,00 et 1,50 V vs RHE. Le catalyseur Pt/ATO présente une durabilité accrue par rapport au catalyseur Pt/carbone Vulcan® de référence. Cependant, de nouveaux mécanismes de dégradation ont été mis en évidence dans cette étude : tout d’abord, l’élément dopant Sb est progressivement dissout au cours du vieillissement électrochimique, ce qui implique une perte de conductivité électronique. Cette perte est en partie liée à des incursions à bas potentiel, notamment durant les caractérisations électrochimiques. De plus, entre 5 000 et 10 000 cycles de vieillissement électrochimique (entre 0,60 et 1,00 V vs RHE ou entre 1,00 et 1,50 V vs RHE à 57 °C), le matériau support perd sa structure poreuse et forme un film amorphe peu conducteur. / Conventional electrocatalysts used in proton exchange membrane fuel cells (PEMFC) are composed of platinum nanoparticles supported on high specific surface area carbon blacks. At the cathode side of the PEMFC, where the oxygen reduction reaction (ORR) occurs, the electrochemical potential can reach high values - especially during startup-shutdown operating conditions - resulting in irreversible degradation of the carbon support. A “material” solution consists of replacing the carbon with supports based on metal oxides. The latter have to be resistant to electrochemical corrosion, be electronic conductor and have a porous and nano-architectural structure (for the transport of reagents and products and the homogeneous distribution of the ionomer and platinum nanoparticles).In this work, we have developed and characterized electrocatalysts composed of platinum (Pt) nanoparticles based on tin dioxide (SnO2) and titanium dioxide (TiO2) with optimized textural (aerogel, nanofibres or loosetubes morphologies) and electron-conduction properties (doped with niobium Nb or antimony Sb). The best electrocatalytic properties are reached for an antimony-doped SnO2 aerogel support, denoted ATO. The Pt/ATO electrocatalyst has especially a higher specific activity for the ORR than a Pt/carbon Vulcan® electrocatalyst, synthesized in the same conditions, suggesting beneficial interactions between the Pt nanoparticles and the metal oxide support (Strong Metal Support Interactions SMSI).Durability tests simulating automotive operating conditions of a PEMFC were carried out in liquid electrolyte at 57 °C on these two electrocatalysts by cycling between 0.60 and 1.00 V vs the reversible hydrogen electrode (RHE) or between 1.00 and 1.50 V vs RHE. The Pt/ATO electrocatalyst has an increased stability compared to the reference Pt/carbon Vulcan® electrocatalyst. However, new degradation mechanisms were highlighted in this study: first, the doping element (Sb) is progressively dissolved during electrochemical ageing, which implies a loss of electronic conductivity. This loss is partly due to incursions at low potential, including during electrochemical characterizations. Moreover, between 5,000 and 10,000 cycles of the accelerated stress tests (between 0.60 and 1.00 V vs RHE or between 1.00 and 1.50 V vs RHE at 57 °C), the support loses its porous structure and forms a poorly conductive amorphous film.
200

Caractérisation du vieillissement de nanoparticules de Pt/C ou PtCo/C. Effets des modifications morphologiques et de composition sur l'électrocatalyse de la réaction de réduction de l'oxygène / Pt/C and Pt-Co/C nanostructured electrocatalysts deposed on high surface area study : morphological and compositional effects on oxygen reduction reaction

Nikkuni, Flavio 29 July 2013 (has links)
Ce travail de thèse a concerné l’étude du comportement de nanoparticules d’électrocatalyseurs à base de Pt et Co déposées sur carbone de grande aire développée (Pt/C, PtCo/C et Pt3Co/C) en conditions représentative d’un fonctionnement à la cathode d’une pile à combustible à membrane échangeuse de protons. Dans une première phase, des électrodes modèles de ces matériaux ont été préparées sur des embouts de carbone vitreux compatibles avec une utilisation en montage d’électrode à disque tournant en milieu acide sulfurique, pour étudier l’évolution des performances électrochimiques (adsorption/désorption de l’hydrogène, Hupd, électrooxydation d’une monocouche de CO adsorbée à la surface du catalyseur : « CO-stripping », cinétique d’électroréduction de l’oxygène) après cyclage accéléré de potentiel (0,1 à 0,9 V vs. RHE et 0,6 à 0,9 V vs. RHE par créneaux d’une minute à chaque potentiel). Ces mesures électrochimiques ont été complétées par des observations statistiques par microscopie électronique en transmission (TEM) et fluorescence X (X-EDS) avant/après ces vieillissements sur des prélèvements représentatifs des couches actives. Les résultats montrent que le cobalt est irréversiblement oxydé/dissous des alliages Pt-Co et que la maturation d’Ostwald advient (pour le Pt) spécialement lorsque la borne inférieure de potentiel est fixée à 0,1 V vs. RHE. Ces mesures statistiques ont été confirmées par des expériences de MET en localisation identique (ILTEM), dans lesquelles les mêmes nanoparticules sont physiquement observées avant/après électrochimie réalisée sur la grille de microscopie[1]. Dans un second temps, des vieillissements identiques ont été mis en œuvre sur les mêmes matériaux électrocatalytiques en électrolyte polymère (Nafion), plus représentatif des conditions PEMFC, par utilisation d’une ultramicroélectrode à cavité et d’une « cellule sèche » dans laquelle le seul électrolyte est le Nafion (il n’y a donc pas d’électrolyte liquide). Dans ces conditions, plus proches des conditions réelles de fonctionnement d’une PEMFC, les mécanismes de dégradations sont différents de ceux observés en présence (d’excès) d’électrolyte liquide, parce que (entre autre), les ions Pt2+ formés à haut potentiel sont piégés dans le ionomère et donc plus faciles à redéposer sur les nanoparticules restantes. Le changement de morphologie (et composition) des nanoparticules de Pt/C (et Pt-Co/C) n’est donc pas identique en milieu H2SO4 et en milieu Nafion, ce qui montre que les tests réalisés en condition de laboratoire (en électrolyte liquide) ne sont pas forcément représentatifs de ce qui advient en PEMFC. Par extension, cette cellule sèche a été mise en œuvre pour mesurer les propriétés électrocatalytiques des différents électrocatalyseurs et, une fois encore, le milieu électrolyte liquide ne rend pas compte des performances observées en milieu « polymère ». Ces mesures ont été complétées par des observations statistiques en MET. Enfin, et il s’agit d’une innovation conséquente propre à ce travail, la méthode ILTEM a été employée pour des grilles de microscopie (supportant les électrocatalyseurs) n’ayant été utilisées qu’en interface avec un électrolyte polymère. Cela a permis de confirmer de manière quantitative et sur les mêmes grains de carbone / nanoparticules de Pt (ou Pt-Co) que les dégradations observées en milieu électrolyte liquide ne rendent pas compte de celles advenant en milieu polymère, la présence d’eau liquide jouant un rôle déterminant dans le premier cas (dissolution des espèces Pt2+/Co2+, oxydation du carbone, etc.). / In this study the oxygen reduction reaction (ORR) activity of Pt/C, Pt3Co/C and PtCo/C electrocatalysts supported on high surface area carbon (Vulcan XC-72) was correlated to their structural, morphological and compositional changes experienced after accelerated aging tests. The electrolytes were sulfuric acid at several concentrations and Nafion® ionomer membrane. These tests are based on different protocols that consisted of stepping the potential or keeping the electrode polarized at fixed potentials. The protocols which used steps consisted of stepping the potential during 1 minute for 15 hours overall successively between 0.9 and 0.1 V vs. ERH, 0.9 and 0.6 V vs. ERH, 1.05 and 0.10 V vs. ERH and 1.05 and 0.65 V vs. ERH. For the aging at fixed polarization (15 hours), the following potentials were used: 0.9, 0.6 and 0.1 V vs. ERH. After the 0.9 – 0.1 V vs. ERH aging in aqueous acidic solution, the Pt-Co/C catalysts showed no changes in the activity, while for Pt/C an improvement was seen. However for 1.05 – 0.10 V vs. ERH for Pt/C there was also an improvement while for the other catalysts there was a decrease of the activity. For all other protocols, a loss in activity was observed for all catalysts. Transmission electron microscopy (TEM) coupled with X-ray energy dispersive spectroscopy (X-EDS) analyses were used to characterize the as received and aged catalysts. A particularity of this work is the use of identical location transmission electron microscopy (ILTEM) technique, with the objective of analyzing the same electrode regions or particles before and after the accelerated ageing processes, so that it was possible to follow all the morphological, structural and compositional changes caused by the catalyst aging processes. The catalysts were compared before and after aging regarding the mean particle size, shape, particle density and composition and correlating these with the catalytic activity. Generally it was observed that the degradation correspond to carbon corrosion, coalescence, dissolution and re-precipitation of the catalyst particles for all aging protocols. The Pt/C catalyst, for example, for which an increase of particle mean size without any negative effect of agglomeration was observed, presented an improvement of the catalytic activity, while Pt-Co/C, in spite of the increase of the mean particle size and cobalt dissolution, presented worse or at most the same activity as that of the uncycled materials. Finally, the degradation mechanisms of the electrocatalysts aged in dry electrochemical environment using a Nafion® 115 membrane as polymer electrolyte were characterized by Identical Location Transmission Electron Microscopy, in conditions that perfectly mimic real PEMFC operation. The structural, morphological and compositional changes of the nanoparticles occurring during an accelerated stress test were bridged to changes of their intrinsic kinetics towards the oxygen reduction reaction in Nafion® 115 electrolyte, thanks to an ultramicroelectrode with cavity loaded with the catalyst. The unique setup used herein further enabled to compare the Nafion® environment with conventional liquid electrolyte in which accelerated stress tests are usually performed. Although the nanoparticles are modified upon ageing at Nafion® interface, the degradation processes are milder and different than those observed in liquid electrolyte, mostly following the absence of liquid water and the lack of ion mobility within the Nafion® membrane.

Page generated in 0.0805 seconds