Spelling suggestions: "subject:"pulsed power systems"" "subject:"avulsed power systems""
1 |
Data modeling for Shipboard Power SystemWu, Jian. January 2004 (has links)
Thesis (M.S.)--Mississippi State University. Department of Electrical and Computer Engineering. / Title from title screen. Includes bibliographical references.
|
2 |
Simulation and experimental study of the multichanneling rimfire gas switchKemp, Mark A., January 2005 (has links)
Thesis (M.S.) University of Missouri-Columbia, 2005. / The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file viewed on (July 10, 2006) Includes bibliographical references.
|
3 |
High power Tesla driven miniature plasma opening switchKumar, Rajesh January 2009 (has links)
The plasma opening switch (POS) is used in pulsed power systems where a very fast opening and high current switch is required. Plasma is injected into the switch, which carries a large conduction current, before it opens in a process that lasts for a few nanosecond and transfers the current to a parallel-connected load at a much increased voltage and with a much shorter rise time. The conduction and opening times of the switch are dependent on plasma parameters such as the distribution, speed and species, all of which are determined by the plasma source. Most of the earlier reported work involves large dimension POSs and a correspondingly high input current (more than 100 kA) and uses carbon plasma. One main objective of the present research was to achieve a low input current (20 kA) and miniaturised POS by using hydrogen plasma rather than carbon plasma on account of its lower mass. A cable gun was selected for producing the plasma, since although this produces both hydrogen and carbon plasma these arise different times during its operation. For the present application a Tesla transformer was used in preference to a Marx generator to produce an initial high voltage pulse for the system, on the basis of its simpler design and cost effectiveness. This transformer together with an associated water PFL (pulse forming line) and pressurised switch was capable of producing a load current in excess of 20 kA with a rise time of 53 ns, which was fed through the POS to the final load. Special diagnostics arrangements were necessary to measure the fast high current and voltage pulse a in nonintrusive way. Faraday cups and a high speed camera were used to measure the plasma parameters. The overall system built (i.e. including the POS) is capable of producing a 22 kA current with a rise time of 5 ns, and of generating a power of more than 10 GW. Much of the work detailed in the thesis has already been presented in peer reviewed journals and at prestigious international conferences.
|
4 |
Design and optimization of a 600-KJ railgun power supply /Warnock, Dwight S. January 2003 (has links) (PDF)
Thesis (M.S. in Electrical Engineering)--Naval Postgraduate School, September 2003. / Thesis advisor(s): Robert W. Ashton, William B. Maier II. Includes bibliographical references (p. 83-84). Also available online.
|
5 |
Langmuir probe measurements in the plume of a pulsed plasma thrusterByrne, Lawrence Thomas. January 2002 (has links)
Thesis (M.S.)--Worcester Polytechnic Institute. / Keywords: PPT; pulsed plasma thruster; Langmuir probe; plasma diagnostics; electric propulsion; electron temperature; electron density. Includes bibliographical references (p. 97-102).
|
6 |
Laser target triggering of gas switchesSullivan, Dustin L. Kovaleski, Scott D. January 2008 (has links)
The entire thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file; a non-technical public abstract appears in the public.pdf file. Title from PDF of title page (University of Missouri--Columbia, viewed on October 5, 2009). Thesis advisor: Dr. Scott Kovaleski. Includes bibliographical references.
|
7 |
Electromechanical Modeling and Open-Loop Control of Parallel-Plate Pulsed Plasma Microthrusters with Applied Magnetic FieldsLaperriere, David Daniel. January 2005 (has links)
Thesis (M.S.) -- Worcester Polytechnic Institute. / Keywords: electric propulsion; applied magnetic fields; pulsed plasma thruster. Includes bibliographical references (p. 91-94).
|
8 |
A pulsed power system design using lithium-ion batteries and one charger per batteryFiller, Frank E. January 2009 (has links) (PDF)
Thesis (M.S. in Electrical Engineering)--Naval Postgraduate School, December 2009. / Thesis Advisor(s): Julian, Alexander L. Second Reader: Crisiti, Roberto. "December 2009." Description based on title screen as viewed on January 28, 2010. Author(s) subject terms: Pulsed power, charger, buck converter, field programmable gate array (FPGA), lithium-ion batteries. Includes bibliographical references (p. 77-79). Also available in print.
|
9 |
Investigation or a pulsed plasma thruster plume using a quadruple Langmuir probe techniqueZwahlen, Jurg C. January 2003 (has links)
Thesis (M.S.)--Worcester Polytechnic Institute. / Keywords: Langmuir probes; spacecraft; electric propulsion. Includes bibliographical references (p.69-71).
|
10 |
Modeling and simulations of diphasic composites for development of high energy density dielectricsPatil, Sandeep Kesharsingh, January 2008 (has links) (PDF)
Thesis (Ph. D.)--Missouri University of Science and Technology, 2008. / Vita. The entire thesis text is included in file. Title from title screen of thesis/dissertation PDF file (viewed April 21, 2008) Includes bibliographical references.
|
Page generated in 0.0733 seconds