• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 267
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 269
  • 108
  • 92
  • 71
  • 70
  • 66
  • 55
  • 48
  • 47
  • 46
  • 41
  • 41
  • 37
  • 32
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Métodos de coleta de deposição para ensaios de deriva em aplicações aéreas /

Chechetto, Rodolfo Glauber, 1987. January 2015 (has links)
Orientador: Ulisses Rocha Antuniassi / Banca: Otavio Jorge Abi Saab / Banca: Paulo Roberto Arbex Silva / Banca: Edivaldo Domingues Velini / Banca: João Paulo Arantes R. da Cunha / Resumo: A produção agrícola em grande escala se tornou pouco viável sem a utilização de produtos fitossanitários. Esses são responsáveis por controles preventivos e curativos das plantas cultivadas em relação a problemas causados por insetos-pragas, doenças e plantas daninhas, porém, deve-se evitar a contaminação ambiental, humana e do alimento por meio da deriva, que é a perda do produto fitossanitário aplicado para locais não desejados. Para que essa deriva seja evitada, busca-se adquirir um conhecimento do comportamento das gotas após as pulverizações, principalmente em aplicações aéreas, onde as condições climáticas são ainda mais determinantes. Neste contexto, o objetivo dessa pesquisa foi analisar, comparativamente, os métodos de coleta de dados para modelagem de deriva com coletores horizontais e verticais em pulverizações de gotas finas e médias, visando analisar as implicações da escolha de um dos métodos e correlacionar os dados obtidos em ambas as metodologias em aplicação aérea. Foram avaliados dois tratamentos com quatro repetições, com gotas finas (GF) e médias (GM) pulverizadas com uma aeronave Ipanema e ponta de pulverização CP-03, em que foi pulverizada uma calda contendo uma concentração de inseticida em mistura ao corante azul brilhante. A deriva foi avaliada fora da área aplicada, na direção do vento predominante, por meio de coletores horizontais (lâminas de vidro) e coletores verticais (fios de nylon) distribuídos até 500 metros em relação à área aplicada. Os dados do índice de deriva foram calculados por meio de espectrofotometria e as médias do índice de deriva foram agrupados e ajustados para uma curva (modelo) através das médias e correlacionados a partir do coeficiente de Pearson a 5% de probabilidade. Nos dois tipos de coletores avaliados o tratamento com gotas finas (GF) apresentou maior valor de deriva comparado ao ... / Abstract: Modern large-scale agricultural production is not possible without the use of pesticides. These products are responsible for the maintenance, prevention and protection of crops against problems caused by pests, diseases and weeds. Additionally, a great deal of care has been taken to avoid the environmental, human and food contamination from spray drift, which is defined as the loss of applied pesticide to undesirable locations. To achieve this goal, knowledge of the behavior of droplets after the spraying, especially in aerial application, is even more crucial given the greater effect of climatic conditions. Thus, the aim of this study was to comparatively analyze the methods of data collection for modeling spray drift in aerial application with horizontal and vertical collectors in order to analyze the implications of the choice of a method and correlate the data obtained in both methodologies. Two treatments with four repetitions, a Fine spray (GF) and a Medium spray (GM), were used. The treatments were made using an aircraft (Ipanema) equipped with CP nozzles, and sprayed insecticide + Brilliant Blue dye as the spray solution. The drift was evaluated downwind from the applied area, using horizontal collectors (glass slides) and vertical collectors (nylon strings) positioned at distances up to 500 meters downwind of the applied area. The data for the drift index were determined from the spectrophotometry method and averages of the drift index were grouped and adjusted to a curve (model) through the averages and correlated the data from the Pearson Coefficient at a 5% probability. Results showed that with both collector types higher drift values were observed with the Fine spray than the treatment with the ... / Doutor
22

Desempenho operacional de uma ponteira de pulverização eletrostatica para o tratamento fitossanitario da cultura do algodoeiro (Gossypium sp)

Soares, Brenner Ferreira 03 August 2018 (has links)
Orientador : Antonio Jose da Silva Maciel / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-03T00:42:31Z (GMT). No. of bitstreams: 1 Soares_BrennerFerreira_M.pdf: 602132 bytes, checksum: 7d59ba113a2f65edc911a36d5c375dd8 (MD5) Previous issue date: 2001 / Mestrado
23

Avaliação da qualidade de pulverização em plantas de tomate utilizando diferentes pontas / Assessment of quality of spraying tomato plants using different nozzles

Zambianco, Edmar Casarin 08 November 2013 (has links)
A tecnologia da aplicação tem papel fundamental na agricultura, pois proporciona uma correta aplicação do produto biologicamente ativo no alvo, ocasionando um melhor aproveitamento dos agrotóxicos. O objetivo do trabalho foi avaliar a influência de diferentes pontas e pressões na qualidade da pulverização na cultura do tomate por meio da quantificação do depósito e da cobertura foliar. Foram estudadas as pontas GA 11002 (jato plano com indução de ar), TTJ 60-11002 (jato plano duplo) e TT 11002 (jato plano padrão), todas nas pressões de 200, 350 e 500 kPa. Para todos os tratamentos a taxa de aplicação foi de 180 L ha-1. O percentual de cobertura foliar foi quantificado por meio da análise de imagens que detectaram o traçador fluorescente LRM 100 com o auxílio de luz ultravioleta. As imagens foram capturadas por uma câmera digital e processadas pelo software QUANT. O depósito foi quantificado pela extração e quantificação do traçador azul brilhante FD&C N°1 por meio de espectrofotometria. Para ambos os parâmetros foram analisadas amostras do estrato superior e inferior da planta. Houve diferença estatística somente para a cobertura foliar, sendo que na parte superior da planta a ponta de jato plano duplo apresentou menor cobertura na menor pressão. Nas maiores pressões houve um aumento da cobertura foliar favorecido pela formação de gotas médias e finas pelas pontas avaliadas. No estrato inferior a eficiência na cobertura foliar da ponta de jato plano diminui com o aumento da pressão. O depósito de pulverização foi favorecido pelo aumento da cobertura foliar. / The application technology plays a key role in agriculture as it provides a correct application of the product biologically active in the target, causing a better use of pesticides. The aim of this study was to evaluate the influence of different nozzles and spray pressures acting on tomato by quantifying the deposit and leaf coverage. Were studied the nozzles GA 11002 (flat fan air induction), TTJ 60-11002 (twin flat fan) and TT 11002 (standard flat fan), all pressures of 200, 350 and 500 kPa. For all treatments, the application rate was 180 L h-1. The percentage of leaf coverage was quantified by image analysis to detect the fluorescent tracer LRM 100 with the aid of ultraviolet light. The images were captured by a digital camera and processed by software QUANT. The deposit was quantified by extraction and quantification of tracer bright blue FD&C N° 1 by spectrophotometry. For both parameters were analyzed samples of top and bottom of the parts plant. Statistical difference only for leaf coverage, and at the top of the plant to twin flat fan nozzles showed lower coverage in less pressure. In the higher pressures there was an increase of leaf coverage favored by the formation of fine droplets medium and evaluated nozzles. In the bottom part plant coverage efficiency of foliar flat fan nozzles decreases with increasing pressure. The spray deposit was favored by increased leaf coverage.
24

Pontas e adjuvantes no potencial risco de deriva em pulverizações de produtos fitossanitários

Madureira, Ronaldo Porto [UNESP] 22 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-22Bitstream added on 2014-06-13T20:58:43Z : No. of bitstreams: 1 madureira_rp_me_botfca.pdf: 401122 bytes, checksum: 27d86707742c65e49ff5859c9b851b37 (MD5) / Um dos maiores problemas enfrentados durante a pulverização dos produtos fitossanitários é a ocorrência de deriva. Considerada uma das principais formas de perda em pulverização, a deriva pode ocasionar prejuízos a culturas adjacentes sensíveis, redução da eficácia bem como a contaminação do ambiente. Com os objetivos de estudar o efeito de pontas de pulverização e a adição de adjuvantes no potencial risco de deriva (PRD) da pulverização bem como o efeito desses produtos sobre a tensão superficial e ângulo de contato de gotas das caldas aquosas com a superfície vegetal, três experimentos foram conduzidos em laboratório. O primeiro experimento foi conduzido em túnel de vento avaliando o PRD de pontas associadas a caldas contendo ou não adjuvantes. O delineamento experimental foi inteiramente ao acaso, com 8 tratamentos e 4 repetições. Os tratamentos foram quatro tipos de calda (água, água + surfatante organosiliconado, água + polímero vegetal e água + éster metilado de óleo de soja) combinados a duas pontas de pulverização de energia hidráulica (Jato plano simples com indução de ar e Jato plano inclinado). O segundo experimento foi realizado utilizando o mesmo delineamento e tratamentos do primeiro experimento para avaliação do espectro de gotas. O último experimento constitui da avaliação da cinética da tensão superficial e ângulo de contato da gota com a superfície foliar de plantas de algodão. Houve efeito dos tipos de pontas de pulverização e adjuvantes sobre o PRD. A ponta jato plano simples com indução de ar, proporcionou menor PRD. A combinação da ponta de jato plano simples com indução de ar com o adjuvante a base de um polímero vegetal foi o tratamento que proporcionou menor PRD. Com relação ao... / One of the biggest problems faced during spraying of pesticides is the drift occurrence. Considered one of the main forms of loss the spray drift can cause damage to sensitive crops, as well as environmental contamination. With the aim of study the effect of spray nozzles and the adjuvants addition on the potential risk of drift (PRD) spraying. As the interference of adjuvants on water solution surface tension and contact angle under foliar surface three experiments were conducted in laboratory. The first experiment was carried out in a wind tunnel to evaluate the potential risk of drift tips using two nozzles combined at water solutions with or without adjuvants. The experimental design was completely randomized design with 8 treatments and 4 replications. The treatments were four types of solutions (water, water + surfactant, water + polymer and water + soybean oil vegetable) combined with two spray nozzles flat fan nozzle with air induction and flat fan nozzle with angled jet). The second experiment was conducted to evaluate the droplet spectrum, using the same design and treatments in the first experiment. The let last experiment evaluated the kinetics of surface tension and contact angle of the drop with the leaf surface of cotton plants. There was an effect of flat flan nozzle with spray nozzles types and adjuvants on the potential risk of drift (PRD). The flat flan nozzle with air induction resulted in a smaller percentage of PRD. The combination of flat flan nozzle air induction and adjuvant polymer based PRD provided the lowest percentage. After droplet spectrum analysis can be verified that the flat fan nozzle with air induction promoted the bigger VMD. This spray nozzle combined with adjuvant polymer based achieved the highest VMD value. For the kinetics of surface tension the aqueous solution containing the organosilicone adjuvant... (Complete abstract click electronic access below)
25

Simulação de perdas por evaporação na pulverização aérea / Simulation of evaporation losses in aerial spraying

Santiago, Humberto 04 August 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-19T13:36:08Z No. of bitstreams: 1 texto completo.pdf: 1876378 bytes, checksum: a9ffe4e0f1842b3b8e4f925ddd6e81a8 (MD5) / Made available in DSpace on 2017-05-19T13:36:08Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1876378 bytes, checksum: a9ffe4e0f1842b3b8e4f925ddd6e81a8 (MD5) Previous issue date: 2016-08-04 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Nas últimas décadas, o uso indiscriminado de agrotóxicos em atividades agrícolas tem sido motivo de preocupação por parte dos pesquisadores que visam promover soluções para a redução do consumo desses produtos. A evaporação e deriva e as principais perdas, e é influenciada pelas condições psicrométricas do ar, como temperatura, umidade e deficit de pressão de vapor. Os métodos para quantificar as perdas por evaporação de agrotóxicos são poucos conhecidos e difíceis de serem avaliados, portanto, objetivou-se, com este trabalho, quantificar as perdas por evaporação e analisar o espectro de gotas em cinco condições de deficit de pressão de vapor do ar e cinco vazões. O experimento foi conduzido em uma câmara climática, com condições psicrométricas controladas, foi utilizado análise de variância com significância de 5% de probabilidade pelo teste t, no Delineamento Composto Central Rotacional (DCCR) e as médias quantitativas foram mensuradas por superfície de resposta. Os parâmetros avaliados foram Porcentagem de Volume de Gotas, com diâmetro na faixa < 100 μm, 100 – 150 μm, 150 – 200 μm, 200 – 250 μm, 250 – 300 μm, 300 – 350 μm, 350 – 400 μm, 400 - 450 μm, 450 - 500 μm, > 500 μm, Dv 10 , Dv 50 , Dv 90 , SPAN, “Perda Real” e “Perda Máxima por Evaporação”. O ensaio para evaporação de gotas em superfície foliar em câmara climática automatizada foi realizado utilizando-se uma microseringa eletrônica para a deposição da gota sobre a superfície da folha de café arábica. O experimento foi conduzido em esquema fatorial (5 x 1), ou seja, cinco deficits de pressão de vapor e uma calda de pulverização (água) em delineamento inteiramente casualizado (DIC). Na análise de variância dos dados significativos a 5% de probabilidade pelo teste t, as médias quantitativas foram mensuradas por regressão quadrática. A deriva foi avaliada em relação ao diâmetro da faixa de 100 μm, 200 μm, 300 μm, 400 μm e 500 μm, em diferentes deficits de pressão de vapor do ar, a análise de variância dos dados significativos a 5% de probabilidade pelo teste t, foi testado as médias quantitativas por regressão quadrática e linear. Pode ser observado nos resultados que, para todas as gotas, independentemente do seu diâmetro, ocorre evaporação, e que a xquantidade de perda máxima da calda de pulverização por evaporação pode chegar a 17%, quando o deficit de pressão de vapor atingir 35 hPa. No experimento, constatou-se que o tempo de evaporação de uma gota na superfície da folha se reduz em 81%, quando o deficit de pressão de vapor do ar varia de 7 hPa a 35 hPa. O tempo de evaporação de uma gota foi de, no máximo, 18 minutos, visto que esse potencial evaporativo depende da interação entre a água e o Deficit de Pressão de Vapor do ar (DPV). As gotas de 100 μm derivam em até 12 metros na condição piscrométrica de 7 hPa. O aumento da vazão de 3,58 L min -1 para 7 L min -1 aumenta o potencial deriva em razão do aumento do número gotas de até 43% dentro da mesma classe de diâmetro. Portanto, a pulverização aérea deve ser monitorada constantemente em razão que suas perdas por evaporação e deriva pode ser intensificada e irá prejudicar a qualidade da aplicação, a condição financeira do produtor e a contaminação da fauna e da flora. / In recent decades, the indiscriminate use of pesticides in agricultural activities has been of concern on the part of researchers to promote solutions to reduce the consumption of these products. Evaporation and drift and the main losses and is influenced by the psychrometric air conditions such as temperature, humidity, vapor pressure deficit. Methods to quantify the losses by evaporation of pesticides are little known and difficult to assess, so if aimed with this work to quantify the losses by evaporation and analyze the spectrum of drops in five vapor pressure deficit conditions air-five flow. The experiment was conducted in a climate chamber with controlled psychrometric conditions, we used analysis of variance with significance level of 5% probability by the t test, and the Delineation Central Composite Rotational (CCRD) and quantitative averages were measured by response surface. The parameters evaluated were percentage drops volume, with a diameter in the range < 100 μm, 100 – 150 μm, 150 – 200 μm, 200 – 250 μm, 250 – 300 μm, 300 – 350 μm, 350 – 400 μm, 400 - 450 μm, 450 - 500 μm, > 500 μm, Dv 10 , Dv 50 , Dv 90 , SPAN, "Real Loss" and "Maximum Loss by Evaporation". The assay for droplet evaporation of leaf surface automated climatic chamber was performed using an electronic microsyringe for depositing the droplet onto the surface of sheet Arabica coffee. The experiment was conducted in a factorial scheme (5 x 1), five vapor pressure deficits and a spray solution (water) in a completely randomized design (CRD). In the analysis of variance of the significant data to 5% probability by the t test, the quantitative medium were measured by quadratic regression. The drift was evaluated in relation to the diameter of 100 μm, 200 μm, 300 μm, 400 μm e 500 μm in different deficits air vapor pressure, analysis of variance of the significant data at 5% probability by t test, was tested by quantitative medium quadratic and linear regression. It can be seen in the results, for all the drops, regardless of its diameter, is evaporation, and the maximum amount of the evaporative spray solution loss can reach 17% when the vapor pressure deficit to 35 hPa. In the experiment, it was found that the evaporation time for a drop on the surface of the sheet is reduced by 81%, when the deficit of xiiair vapor pressure ranges from 7 hPa to 35 hPa. The evaporation time was a drop of no more than 18 minutes, whereas this potential depends on the interaction between evaporative water and air Deficit Vapor Pressure (DPV). The droplets of 100 μm derive up to 12 meters in piscrométrica condition 7 hPa. The increased flow rate of 3.58 L min -1 for 7 L min -1 increases the potential drift due to the increased number of drops to 43% within the same diameter class. Therefore, aerial spraying should be constantly monitored because their losses by evaporation and drift can be intensified and will damage the quality of implementation, the financial condition of the producer and the contamination of the fauna and flora.
26

Pontas e adjuvantes no potencial risco de deriva em pulverizações de produtos fitossanitários /

Madureira, Ronaldo Porto, 1986. January 2013 (has links)
Orientador: Carlos Gilberto Raetano / Banca: Caio Antonio Carbonari / Banca: Marco Antonio Gandolfo / Resumo: Um dos maiores problemas enfrentados durante a pulverização dos produtos fitossanitários é a ocorrência de deriva. Considerada uma das principais formas de perda em pulverização, a deriva pode ocasionar prejuízos a culturas adjacentes sensíveis, redução da eficácia bem como a contaminação do ambiente. Com os objetivos de estudar o efeito de pontas de pulverização e a adição de adjuvantes no potencial risco de deriva (PRD) da pulverização bem como o efeito desses produtos sobre a tensão superficial e ângulo de contato de gotas das caldas aquosas com a superfície vegetal, três experimentos foram conduzidos em laboratório. O primeiro experimento foi conduzido em túnel de vento avaliando o PRD de pontas associadas a caldas contendo ou não adjuvantes. O delineamento experimental foi inteiramente ao acaso, com 8 tratamentos e 4 repetições. Os tratamentos foram quatro tipos de calda (água, água + surfatante organosiliconado, água + polímero vegetal e água + éster metilado de óleo de soja) combinados a duas pontas de pulverização de energia hidráulica (Jato plano simples com indução de ar e Jato plano inclinado). O segundo experimento foi realizado utilizando o mesmo delineamento e tratamentos do primeiro experimento para avaliação do espectro de gotas. O último experimento constitui da avaliação da cinética da tensão superficial e ângulo de contato da gota com a superfície foliar de plantas de algodão. Houve efeito dos tipos de pontas de pulverização e adjuvantes sobre o PRD. A ponta jato plano simples com indução de ar, proporcionou menor PRD. A combinação da ponta de jato plano simples com indução de ar com o adjuvante a base de um polímero vegetal foi o tratamento que proporcionou menor PRD. Com relação ao... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: One of the biggest problems faced during spraying of pesticides is the drift occurrence. Considered one of the main forms of loss the spray drift can cause damage to sensitive crops, as well as environmental contamination. With the aim of study the effect of spray nozzles and the adjuvants addition on the potential risk of drift (PRD) spraying. As the interference of adjuvants on water solution surface tension and contact angle under foliar surface three experiments were conducted in laboratory. The first experiment was carried out in a wind tunnel to evaluate the potential risk of drift tips using two nozzles combined at water solutions with or without adjuvants. The experimental design was completely randomized design with 8 treatments and 4 replications. The treatments were four types of solutions (water, water + surfactant, water + polymer and water + soybean oil vegetable) combined with two spray nozzles flat fan nozzle with air induction and flat fan nozzle with angled jet). The second experiment was conducted to evaluate the droplet spectrum, using the same design and treatments in the first experiment. The let last experiment evaluated the kinetics of surface tension and contact angle of the drop with the leaf surface of cotton plants. There was an effect of flat flan nozzle with spray nozzles types and adjuvants on the potential risk of drift (PRD). The flat flan nozzle with air induction resulted in a smaller percentage of PRD. The combination of flat flan nozzle air induction and adjuvant polymer based PRD provided the lowest percentage. After droplet spectrum analysis can be verified that the flat fan nozzle with air induction promoted the bigger VMD. This spray nozzle combined with adjuvant polymer based achieved the highest VMD value. For the kinetics of surface tension the aqueous solution containing the organosilicone adjuvant... (Complete abstract click electronic access below) / Mestre
27

Avaliação da qualidade de pulverização em plantas de tomate utilizando diferentes pontas / Assessment of quality of spraying tomato plants using different nozzles

Edmar Casarin Zambianco 08 November 2013 (has links)
A tecnologia da aplicação tem papel fundamental na agricultura, pois proporciona uma correta aplicação do produto biologicamente ativo no alvo, ocasionando um melhor aproveitamento dos agrotóxicos. O objetivo do trabalho foi avaliar a influência de diferentes pontas e pressões na qualidade da pulverização na cultura do tomate por meio da quantificação do depósito e da cobertura foliar. Foram estudadas as pontas GA 11002 (jato plano com indução de ar), TTJ 60-11002 (jato plano duplo) e TT 11002 (jato plano padrão), todas nas pressões de 200, 350 e 500 kPa. Para todos os tratamentos a taxa de aplicação foi de 180 L ha-1. O percentual de cobertura foliar foi quantificado por meio da análise de imagens que detectaram o traçador fluorescente LRM 100 com o auxílio de luz ultravioleta. As imagens foram capturadas por uma câmera digital e processadas pelo software QUANT. O depósito foi quantificado pela extração e quantificação do traçador azul brilhante FD&C N°1 por meio de espectrofotometria. Para ambos os parâmetros foram analisadas amostras do estrato superior e inferior da planta. Houve diferença estatística somente para a cobertura foliar, sendo que na parte superior da planta a ponta de jato plano duplo apresentou menor cobertura na menor pressão. Nas maiores pressões houve um aumento da cobertura foliar favorecido pela formação de gotas médias e finas pelas pontas avaliadas. No estrato inferior a eficiência na cobertura foliar da ponta de jato plano diminui com o aumento da pressão. O depósito de pulverização foi favorecido pelo aumento da cobertura foliar. / The application technology plays a key role in agriculture as it provides a correct application of the product biologically active in the target, causing a better use of pesticides. The aim of this study was to evaluate the influence of different nozzles and spray pressures acting on tomato by quantifying the deposit and leaf coverage. Were studied the nozzles GA 11002 (flat fan air induction), TTJ 60-11002 (twin flat fan) and TT 11002 (standard flat fan), all pressures of 200, 350 and 500 kPa. For all treatments, the application rate was 180 L h-1. The percentage of leaf coverage was quantified by image analysis to detect the fluorescent tracer LRM 100 with the aid of ultraviolet light. The images were captured by a digital camera and processed by software QUANT. The deposit was quantified by extraction and quantification of tracer bright blue FD&C N° 1 by spectrophotometry. For both parameters were analyzed samples of top and bottom of the parts plant. Statistical difference only for leaf coverage, and at the top of the plant to twin flat fan nozzles showed lower coverage in less pressure. In the higher pressures there was an increase of leaf coverage favored by the formation of fine droplets medium and evaluated nozzles. In the bottom part plant coverage efficiency of foliar flat fan nozzles decreases with increasing pressure. The spray deposit was favored by increased leaf coverage.
28

Influência de diferentes pontas de pulverização nas aplicações terrestres em alta velocidade na cultura da soja (Glycine Max) / Influence from different spray nozzles for ground applications using high travel speed in soybean crop (Glycine max)

Zaidan, Samir Elias 16 December 2011 (has links)
O objetivo do trabalho foi o de comparar a eficiência de aplicação de agroquímicos na cultura da soja utilizando diferentes pontas de pulverização para aplicações terrestres em alta velocidade. Foram avaliadas as pontas AXI 110 04 na velocidade de 15 km.h-1 (testemunha), APE Cinza, AXI 110 08, TD Hispeed 110 06 e AXI TWIN 120 06, todos na velocidade de deslocamento de 35 km.h-1. O volume de aplicação foi fixado em 120 L.ha-1. A eficiência de aplicação foi avaliada por dois métodos: Análise do percentual de cobertura utilizando marcador fluorescente e luz ultravioleta e análise de depósito através da recuperação e quantificação do corante azul brilhante FD&C N°1 por espectrofotometria. Ambas as analises foram feitas em amostras retiradas de três partes da planta: Superior, média e inferior. As pontas de pulverização mostraram padrões de cobertura e depósito diferenciados, de modo que na parte superior da planta, a cobertura foi favorecida por gotas mais finas e o depósito melhorado pelo uso de gotas médias. Nas demais partes da planta não houve diferença estatística entre os tratamentos tanto para cobertura quanto para depósito. A velocidade de deslocamento não interferiu na eficiência de aplicação para pontas com mesmo padrão de gota, permitindo o aumento da capacidade efetiva do pulverizador sem diminuição na qualidade da aplicação. / The aim of this study was to compare the efficiency of agrochemical application on soybean crop using different types of spray nozzles for ground applications in high travel speed. It was evaluated the nozzles AXI 110 04 with ground speed of 15 km.h-1 (reference), APE Grey, AXI 110 08, TD Hispeed 110 06 and AXI TWIN 120 06, all using travel speed of 35 km.h-1. The volume rate was fixed in 120L.ha-1. The application efficiency was evaluated by two different methods: Analysis of coverage area using fluorescent dye tracer and UV light and analysis of deposits through the recovery and quantification of bright blue tracer FD&C N°1 by Spectrophotometry. Both analysis were done in samples collected from three parts of the plant: Top, medium and bottom. The spray nozzles showed differences in coverage and deposit pattern, so in the top of the plant, the coverage was increased with smaller droplets and the deposit was increased with medium droplets. In the other parts of the plant, there was no statistical difference between the treatments both for coverage and deposit. The travel speed did not influence the application efficiency for droplet with the same droplet pattern, so it is possible to increase the effective capacity of the sprayer without decreasing the application quality.
29

Velocidade das gotas geradas por pontas de jato plano de faixa ampliada em função da tensão superficial e da viscosidade da calda /

Panini, Rafael Luiz. January 2019 (has links)
Orientador: Ulisses Rocha Antuniassi / Banca: Kléber Pereira Lanças / Banca: Rone Batista de Oliveira / Resumo: O objetivo do presente trabalho foi determinar a velocidade das gotas geradas por uma ponta de jato plano de faixa ampliada (XR11003) em função de variações na tensão superficial e da viscosidade de caldas compostas por diluições de um surfactante e um óleo vegetal. Os adjuvantes utilizados foram o surfactante Agral e o óleo vegetal Natur'óleo, além de uma calda padrão (testemunha) composta apenas por água. Os ensaios foram conduzidos em delineamento inteiramente casualizado com 5 repetições. Para isso foram determinadas as viscosidades e tensão superficial para diferentes concentrações dos adjuvantes, bem como velocidade de gotas. As caldas pulverizadas foram amostradas em condições operacionais idênticas de pressão (2,8 bar), buscando a quantificação das velocidades de forma homogênea, em diferentes diâmetros de gota: 50, 100, 150, 200, 250, 300 e 350 µm. Os experimentos foram conduzidos para coleta na altura de pulverização de 30 cm em relação ao analisador de partículas em tempo real VisiSize Portable (Oxford Lasers Ltd / UK). Foram ajustados modelos para os dados de velocidade e tamanho de gotas, viscosidade e tensão superficial, assim como realizou-se a Análise de Variância para significância do modelo e o coeficiente de determinação múltipla. A análise de correlação foi empregada para verificar o efeito da viscosidade e tensão superficial sobre a velocidade de gotas. Os resultados mostraram que os modelos tridimensionais indicam a formação de gradiente ascendente da ve... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of the present work was to determine the velocity of the droplets generated by a wide band plane jet (XR11003) as a function of variations in surface tension and viscosity of syrups composed of dilutions of a surfactant and vegetable oil. The adjuvants used were the Agral surfactant and the Natur'óleo vegetable oil, besides a standard syringe (control) composed only of water. The trials were conducted in a completely randomized design with 5 replicates. For this, the viscosities and surface tension were determined for different concentrations of the adjuvants, as well as droplet velocity. The pulverized samples were sampled under identical operating pressure conditions (2.8 bar), aiming at the quantification of the homogeneous velocities in different drop diameters: 50, 100, 150, 200, 250, 300 and 350 μm. The experiments were conducted at the 30 cm spray height in relation to the VisiSize Portable (Oxford Lasers Ltd / UK) real-time particle analyzer. Models for the velocity and droplet size, viscosity and surface tension data were adjusted, as well as the Analysis of Variance for model significance and the multiple determination coefficient. Correlation analysis was used to verify the effect of viscosity and surface tension on the droplet velocity. The results showed that the three-dimensional models indicate the formation of an upward velocity gradient as a function of viscosity, that is, a trend of higher velocities was observed for higher viscosity values. The inverse occurred for surface tension (downward velocity gradient as a function of surface tension), that is, a trend of lower velocities was observed for higher values of surface tension. However, no significant correlations were observed between surface tension or viscosity and velocities for each droplet size (p> 0.05). It is concluded, therefore, that for the spray tip XR 11003 at a pressure of 2.8 bar, the droplet ... / Mestre
30

Assistência de ar e volumes de pulverização na deposição de gotas e controle do arroz vermelho (Oryza sativa L.)

Viganó, Leopoldo Luís de Souza [UNESP] 23 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:16Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-23Bitstream added on 2014-06-13T20:28:24Z : No. of bitstreams: 1 vigano_lls_me_botfca.pdf: 315511 bytes, checksum: 1c704179aaf952553a743ea80191f02c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho teve como objetivo avaliar o efeito da assistência de ar junto à barra de pulverização e três volumes de aplicação na dessecação e deposição da calda em arroz vermelho sob cultivo de nabo forrageiro em recuperação de áreas de várzeas, pulverizado com herbicida paraquat e corante azul brilhante, respectivamente. Os volumes de calda de pulverização foram 100, 200 e 300 L ha-1, da solução contendo corante alimentício (0,15%, p/v). Tanto na presença do ar junto à barra quanto na sua ausência foram utilizadas pontas de pulverização de jato plano tipo AXI 110015 a pressão de 117,3 kPa, AXI 11002 e AXI 11003 a pressão de 276 kPa. A avaliação da deposição da pulverização deu-se em folhas de plantas de arroz vermelho. Verificou-se nos resultados que houve diferença na deposição entre diferentes técnicas e volumes de calda testados nas plantas de arroz vermelho. Maior deposição foi alcançada pelo maior volume aplicado (300 L ha-1) com a assistência de ar junto à barra pulverizadora. Não se constatou diferença na deposição quando aplicados os volumes de 100, 200 e 300 L ha-1 sem assistência de ar e 200 e 300 L ha-1 com assistência de ar. As maiores porcentagens de dessecação de arroz vermelho foram constatadas com a aplicação de 300 L ha-1, tanto na presença quanto na ausência de assistência de ar junto à barra pulverizadora. / The aim of this research was to evaluate the effect of air-assistance on spraying at three volumes in the dessecation and deposition on red rice under fodder radish cultivation. To evaluate the dessecation and spray deposition were used paraquat herbicide and a Brilliant Blue dye, respectively. The three volumes of spray were 100, 200 and 300 L ha-1, using a tracer dye at 0,15% (w/v). Both solution used flat fan nozzles AXI 110015 at 117.3 kPa, AXI 11002 and AXI 11003 at 276 kPa. The evaluation of deposition was made on red rice leaves. We observed no significant different deposition between spray techniques and application volumes on red rice plants. Higher deposition was obtained by 300 L ha-1 application with air assistance in the spray boom. No difference it was observed on spray deposition at 100, 200 and 300 L ha-1 volumes without air assistance and at 200 as well as 300 L ha-1 with air assistance. The highest percentages of red rice dessecation were observed with 300 L ha-1 application with or without air assistance at the sleeve boom sprayer.

Page generated in 0.4025 seconds