Determinación de la vulnerabilidad sísmica del Mercado Municipal del Balneario de Pucusana mediante el análisis estático no lineal “pushover”

Estrella Chavez, Juan Jacob, Ochoa Zamalloa, Ángel Jair 26 August 2021 (has links)
Debido al alto peligro de ocurrencia de sismo, al que está expuesto el balneario de Pucusana y el crecimiento poblacional que ha tenido en los últimos años, hace necesario conocer los efectos que producirían un sismo de gran magnitud en esta localidad, según (Silgado, 1978), en el año 1746 ocurrió un sismo de magnitud estimada de 9.0 MW, seguido de un maremoto que destruyó el puerto del callao y según (Tavera, 2008), el área de estudio ocupa una zona de peligro estimado, se espera un sismo de magnitud 8.8 MW, producto de estos estudios se consideró escoger esta localidad como representativa para elaborar un escenario de riesgo sísmico. Ante esta realidad, se hace necesario elaborar escenarios de Riesgo para el balneario de Pucusana. Este trabajo de investigación pretende realizar una mejora a la propuesta realizada por el CENEPRED, en su manual de estimación del riesgo, utilizando el Análisis “PUSHOVER”, mediante la metodología ATC-40, el ASCE41-13 y SEAOC VISION 2000, que permitirá determinar la calidad de la estructura a detalle y compararla con el nivel de peligro de sismo que se tiene producto de los trabajos del proyecto SIRAD 2012. Se ha escogido para realizar este estudio el Mercado Municipal, debido a que es una de las estructuras más importantes del Balneario. Finalmente, el aporte de esta tesis es determinar el nivel de desempeño del mercado municipal de Pucusana, para la determinación del nivel de vulnerabilidad del mismo. / Due to the high danger of earthquake occurrence, to which the Pucusana city is exposed and the population growth that it has had in recent years, it is necessary to know the effects that a large earthquake would produce in this locality, according to (Silgado, 1978 ), in the year 1746 an earthquake of estimated magnitude of 9.0 MW occurred, followed by a tsunami that destroyed the port of Callao and according to (Tavera, 2008), the study area occupies an estimated danger zone, an earthquake of magnitude 8.8 MW, as a result of these studies, it is considered to choose this locality as representative to elaborate a seismic risk scenario. Given this reality, it is necessary to develop Risk scenarios for the Pucusana spa. This research work aims to make an improvement to the proposal made by CENEPRED, in its risk estimation manual, using the “PUSHOVER” Analysis, using the ATC-40 methodology, ASCE41-13 and SEAOC VISION 2000, which will determine the quality of the structure in detail and compare it with the level of earthquake danger that exists as a result of the work of the SIRAD 2012 project. The Municipal Market has been chosen to carry out this study, because it is one of the most important structures in the Spa. Finally, the contribution of this thesis is to determine the level of performance of the municipal market of Pucusana, to determine its level of vulnerability. / Tesis
2

Evaluación de desempeño sísmico de 3 edificaciones de concreto armado para un sismo moderado en la ciudad de Lima / Seismic performance evaluation of 3 reinforced concrete buildings for a moderate earthquake in the city of Lima

Valencia Hidalgo, Andi Vasilio, Orihuela Palomino, Julio Miguel 09 December 2021 (has links)
El objetivo de esta tesis es la de evaluar la respuesta de dos edificaciones de concreto armado cuando son sometidas a un sismo moderado. Para efectuar el análisis sísmico basado en el desempeño se requirió calcular los espectros de demanda del sismo moderado y de capacidad e interceptarlo para luego basarnos en los métodos del ATC-40,FEMA – 440 y determinar en qué rango de desempeño se encontraron. Se analizó los aspectos conceptuales y metodológicos relacionados con la evaluación del daño sísmico sobre edificaciones; asimismo, se estudió otras normas técnicas sismorresistentes que tengan semejanzas con la norma peruana E -030 para este propósito se empleó la metodología del análisis estático incremental no lineal con la utilización del software ETABS. La evaluación del desempeño sísmico se aplicó en tres edificaciones de ocho , seis y cuatro pisos la misma que se diseñó con la norma E-030 actualizada del 2018, con el fin de verificar las máximas demandas en el rango no lineal a través del análisis estático incremental no lineal “Pushover” . / The objective of this thesis is to evaluate the response of two editions of reinforced concrete when subjected to a moderate earthquake. In order to carry out the seismic analysis based on the performance, it was necessary to calculate the demand spectra of the moderate earthquake and capacity and to intersect it and then based on the methods of the ATC-40, FEMA - 440 and determine in what range of performance they were found. The conceptual and methodological aspects related to the evaluation of seismic damage on buildings were analyzed. Also, other seismic technical norms that have similarities with the Peruvian norm E-030 were studied for this purpose, the methodology of the non-linear incremental static analysis was used with the use of the ETABS software. The evaluation of the seismic performance was applied in three buildings of eigth , six and four floors, the same one that was designed with the updated standard E-030 of 2018 ,in order to verify the maximum demands in the non-linear range through the non-linear incremental static analysis "Pushover". / Tesis
3

Análisis de costo-beneficio de reforzamientos sísmico convencional y no convencional a través del diseño por desempeño en un hospital de más de 60 años de antigüedad en una zona altamente sísmica / Cost-benefit analysis of conventional and non-conventional seismic retrofitting by design for performance in a hospital more than 60 years old in a highly seismic zone

Altamirano Huachuhuilca, Anilu Gianella, Criales Valer, Xiomara Massiel 06 December 2021 (has links)
En el presente trabajo se compara el costo beneficio de dos propuestas de reforzamiento para el bloque B del Hospital Casimiro Ulloa el cual es una antigua estructura de más de 60 años de tres niveles de albañilería confinada ubicada en una zona altamente sísmica. El refuerzo convencional es a través de la implementación de placas de concreto y el no convencional es a base de láminas diagonales y anclajes de Polímero Reforzado con Fibras de Carbono (CFRP). Se realiza el análisis estructural no lineal – Pushover bajo las provisiones del ASCE/SEI 41-13 con el fin de obtener la curva de capacidad del modelo As Built y los modelos reforzados. La norma ATC-40 brinda el método de espectro de capacidad con el cual se logra obtener una visión gráfica del nivel de desempeño ya que superpone la curva de capacidad con la demanda. El cálculo de costo para ambos reforzamientos contempla el precio de los materiales, mano de obra y equipos. Por otro lado, el reforzamiento de CFRP es calculado con los valores dados por el proveedor Sika Perú. Los resultados que se obtuvieron al realizar la evaluación sísmica de los tres modelos matemáticos (As Built, placas y CFRP) en términos de capacidad estructural y costo; muestra que el reforzamiento con CFRP es la mejor opción. / This study compares the cost benefit of two reinforcement proposals for Block B of the Casimiro Ulloa Hospital, which is an old three-story, 60-year-old structure built of confined masonry located in a highly seismic area. The conventional reinforcement is through the implementation of concrete walls and the unconventional one is based on diagonal sheets and anchors of Carbon Fiber Reinforced Polymer (CFRP). The non-linear structural analysis - Pushover is performed under the provisions of ASCE/SEI 41-13 in order to obtain the capacity curve of the As Built model and the reinforced models. The ATC-40 standard provides the capacity spectrum method with which to obtain a graphic vision of the performance level since it overlays the capacity curve with the demand. The cost calculation for both reinforcements considers the price of materials, labor and equipment.. On the other hand, the reinforcement of CFRP is calculated with the values given by the provider Sika Peru. The results that were obtained when carrying out the seismic evaluation of the three mathematical models (As built, plates and CFRP) in terms of structural capacity and cost; shows that the reinforcement with CFRP is the best option / Tesis
4

Análisis y diseño estructural de una torre de 40 pisos y 4 sótanos siguiendo normas peruanas incluyendo su desempeño sísmico en el distrito de Santiago de Surco, Lima / Analysis and structural design of a tower 40 stories and 4 basements following peruvian norms including its seismic performance in the district de Santiago de Surco, Lima

Fernández López, Rodrigo Miguel, Zapata Velásquez, Ricardo Timoteo 01 July 2020 (has links)
En la presente investigación se realizará el análisis y diseño estructural de una torre de 40 pisos y 4 sótanos de concreto armado siguiendo normas peruanas y el cálculo de desempeño sísmico en el distrito de Santiago de Surco, Lima. Para esto, la hipótesis plantea sí las normas peruanas cumplen con el desempeño sismorresistente deseado para una torre alta como esta. Para un entendimiento progresivo, primero se hará una descripción de la torre alta a estudiar, su arquitectura, estructura, suelo y otros. En la segunda parte se darán los conceptos necesarios para comprender los tipos de análisis lineal estático, lineal dinámico y no lineal estático. Se definirán los materiales, los diagramas momento – rotación también se explicará la obtención de la curva de capacidad del edificio. Se tocarán conceptos de viento y nivel de desempeño. En la tercera parte, se procederá con en análisis sísmico cumpliendo las exigencias de sismorresistencia, también se hará el análisis por viento para comparar ambos efectos. En el capítulo cuarto se procederá a hacer el diseño estructural usando las normas de concreto armado. En el capítulo cinco se hará el análisis por desempeño usando el método pushover para finalmente conseguir los resultados de este proyecto y a las conclusiones de este desarrollo. / In the present investigation, the analysis and structural design of a 40-storey tower and 4 reinforced concrete basements will be carried out following Peruvian regulations and the calculation of seismic performance in the Santiago de Surco district, Lima. For this, the hypothesis states whether the Peruvian standards meet the desired seismic resistance performance for a tall tower like this one. For a progressive understanding, first a description will be made of the tall tower to study, its architecture, structure, soil and others. In the second part, the concepts necessary to understand the types of static linear analysis, dynamic linear analysis and static non-linear analysis will be given. The materials will be defined, the moment - rotation diagrams will also explain the obtaining of the building capacity curve. Wind and performance level concepts will be discussed. In the third part, we will proceed with seismic analysis complying with the seismic resistance requirements, we will also do the wind analysis to compare both effects. In the fourth chapter, the structural design will be carried out using the reinforced concrete standards. In chapter five the performance analysis will be done using the pushover method to finally get the results of this project and the conclusions of this development. / Tesis
5

Análisis y diseño estructural de una torre de 40 pisos y 4 sótanos siguiendo normas peruanas incluyendo su desempeño sísmico en el distrito de Santiago de Surco, Lima / Analysis and structural design of a tower 40 stories and 4 basements following peruvian norms including its seismic performance in the district de Santiago de Surco, Lima

Fernández López, Rodrigo Miguel, Zapata Velásquez, Ricardo Timoteo 04 November 2019 (has links)
En la presente investigación se realiza el análisis y diseño estructural de una torre de 40 pisos y 4 sótanos de concreto armado siguiendo normas peruanas y el cálculo de su nivel de desempeño sísmico en el distrito de Santiago de Surco, Lima. Para esto, la hipótesis plantea que las normas peruanas cumplen con el desempeño sismorresistente deseado para esta torre alta. Para un entendimiento progresivo, primero se hará una descripción de la torre alta a estudiar, su arquitectura, suelo entre otros. En la segunda parte se dan los conceptos necesarios para comprender los tipos de análisis lineal estático, lineal dinámico y no lineal estático. Se definen los materiales, los diagramas momento – rotación para luego explicar la obtención de la curva de capacidad del edificio. Se tocan conceptos de desempeño y viento. En la tercera parte, se procede con en análisis sísmico usando las exigencias de sismorresistencia, también se hace el análisis por viento para finalmente comparar ambos efectos. En el capítulo cuarto se procede a hacer el diseño estructural usando las normas de concreto armado. En el capítulo cinco se hace el análisis por desempeño usando el método pushover para finalmente conseguir los resultados de este proyecto y a las conclusiones de este desarrollo. / In the present investigation, the analysis and structural design of a 40-story tower and 4 basements of reinforced concrete are carried out following Peruvian standards and the calculation of its level of seismic performance in the district of Santiago de Surco, Lima. For this, the hypothesis states that Peruvian standards comply with the seismic-resistant performance desired for this high tower. For a progressive understanding, first a description will be made of the tall tower to be studied, its architecture, ground among others. In the second part, the concepts necessary to understand the types of static linear, dynamic linear and static nonlinear analysis are given. The materials are defined, the moment - rotation diagrams and then explain the obtaining of the building capacity curve. Performance and wind concepts are touched. In the third part, we proceed with seismic analysis using the seismic resistance requirements, the wind analysis is also done to finally compare both effects. In the fourth chapter the structural design is done using the reinforced concrete standards. In chapter five the performance analysis is done using the pushover method to finally get the results of this project and the conclusions of this development. / Tesis
6

Nelineární dynamická analýza konstrukce zatížena seismickými účinky / Nonlinear dynamic analysis of structures with seismic loads

Navrátilová, Martina January 2015 (has links)
Diploma thesis compares the methods for the calculation of the response of structures with seismic loads. Linear and nonlinear analyses are used for the calculations. In the case of linear analysis response spectrum method is applied. For nonlinear analysis pushover method is used. These two methods are compared in programs AxisVM and RFEM on the examples of high-rise building and space frame.