• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • Tagged with
  • 9
  • 9
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação do fator de proteção solar “in vitro”

Adad, Maria Cecília Baptista Todeschini January 2007 (has links)
Made available in DSpace on 2013-08-07T18:54:31Z (GMT). No. of bitstreams: 1 000394301-Texto+Parcial-0.pdf: 249244 bytes, checksum: 81a6f5edfc2ed4ab135406882e3bd2d2 (MD5) Previous issue date: 2007 / This research broaches the determining of Solar Protection Factor (SPF) based on in vitro methodology, which has been made by quantitative analyses, evaluating the sunscreen like a radiation barrier that absorbs the ultraviolet radiation and evaluate the homogeneity of protection; while the in vivo methodology is based on a qualitative evaluation, recommended by national and international guidelines. Nowadays this is made through observation of redness on the volunteers back skin, Erythema, with and without the solar protector, when exposed to solar simulator artificial source. A total of eight different methodologies were tested to determinate the in vitro SPF from the evaluating of lotion samples took off 9 commercial marks of sunscreen, with different SPF, totalizing 20 products evaluated. This work verified through the selected in vitro Method that most of the in vivo SPF labeled at solar protectors isn’t comparable. Besides, the in vivo methodology mainly considers the UV-B region, while the selected in vitro Method gives SPF for whole ultraviolet region that reaches the earth surface, whose values are trackable and comparable, given the UV-A and UV-B FPS and the total FPS. / Esta pesquisa abordou a importância de determinar o FPS “in vitro” e as limitações do Método “in vivo”, atualmente recomendado pelos órgãos competentes, nacionais e internacionais. O Método “in vitro” proposto fornece respostas quantitativas do FPS, e avalia os protetores solares como uma barreira à radiação ultravioleta, considerando também a homogeneidade de proteção; enquanto que a metodologia “in vivo”, baseada na avaliação qualitativa, consiste da observação do tempo necessário para o aparecimento da vermelhidão na pele, Eritema, das costas de voluntários, com e sem protetor solar, expostos à fonte artificial simuladora do sol. Foram testadas oito metodologias a partir da avaliação das amostras retiradas de 9 marcas de produtos comerciais com diferentes FPS, totalizando 20 produtos. Este trabalho verificou, por meio do Método “in vitro” mais apropriado, que grande parte dos FPS “in vivo”, informados nos rótulos das embalagens dos protetores solares, não possui comparabilidade quantitativa. Além disso, a metodologia “in vivo” determina o grau de proteção preponderantemente para a região UV-B, enquanto que o Método “in vitro” selecionado fornece o FPS para toda a região espectral ultravioleta que incide na superfície terrestre, cujos valores são rastreáveis e comparáveis, além de permitir a obtenção do FPS (UV-A), FPS (UV-B) ou do FPS total.
2

Síntese de compósitos baseados em polietileno/nanofibras de polianilina e grafite

Graebin, Ana Paula January 2015 (has links)
Made available in DSpace on 2015-06-20T02:07:24Z (GMT). No. of bitstreams: 1 000470698-Texto+Completo-0.pdf: 3211899 bytes, checksum: 304adc552bbe30591d967a6721608b0c (MD5) Previous issue date: 2015 / The research work is related to the preparation of polymer composites based on polyaniline (PAni) and graphite. Polyaniline nanofibers were synthesized by the method of rapid mixing. Hybrid load (PAni/NLG) was synthesized by polymerizing aniline in the presence of graphite nanosheets (NLG). Polymer composites were prepared using differents methodologies: melt blending and in situ polymerization. In preparing polymer composites of polyethylene (PE)/PAni, PE/NLG and PE/PAni/NLG by in situ polymerization, the catalyst system was used Cp2ZrCl2/MAO. Polymeric composites by melt blending with the melt PE and conductive load were prepared in the melting chamber. The conductive loads as well as those produced composites were characterized by Scanning Electron Microscopy (SEM), TGA (Thermogravimetric Analysis), DSC (Differential Scanning Calorimetry) and electrical properties (Probe Two Tips). Rapid mixing, nanofiber synthesis methodology was efficient, as were prepared nanofibers with a diameter of approximately 50-80 nm and with yield of the synthesis reaction of 23%. From the results it was found that the in situ polymerization was the most suitable method to produce polymeric composites in the presence of polyaniline, as the composite exhibited good load dispersion inducing the formation of the conductive network. The presence of graphite in hybrid material improves electrical conductivity of composites and the quality of nanofibers is affected positively. The methodology of the mixture by melting was not efficient to disperse the nanofiber Pani in PE matrix. / O trabalho de pesquisa está relacionado com a preparação de compósitos de polietileno (PE) contendo carga condutiva baseadas na polianilina (PAni) e grafite. Nanofibras de PAni foram sintetizadas através do método da mistura rápida. Carga híbrida (PAni/NLG) foi sintetizada por meio da polimerização da anilina na presença de nanolâminas de grafite (NLG). Compósitos foram preparados utilizando-se diferentes metodologias: mistura por fusão e polimerização in situ. Na preparação de compósitos poliméricos de polietileno (PE)/PAni, PE/NLG e PE/PAni/NLG, por meio da polimerização in situ, foi utilizado sistema catalítico Cp2ZrCl2/MAO. As cargas condutivas assim como os compósitos produzidos foram caracterizados por MEV (Microscopia Eletrônica de varredura), TGA (Análise Termogravimétrica), DSC (Calorimetria Diferencial de Varredura) e propriedades elétricas (Sonda de Duas Pontas). A interação entre a PAni e o sistema catalítico Cp2ZrCl2/MAO foi investigada através da Técnica da Voltametria Cíclica e de Pulso Diferencial. A mistura rápida, metodologia de síntese de nanofibras mostrou-se eficiente, pois foram preparadas nanofibras com diâmetro de aproximadamente 50-80 nm e com rendimento de reação de 23%. A partir dos resultados constatou-se que a polimerizaçao in situ foi a metodologia mais adequada para produzir compósitos poliméricos na presença de PAni, visto que os compósitos apresentaram boa dispersão da carga induzindo à formação da rede condutiva. A presença de grafite no material híbrido melhora a condutividade elétrica dos compósitos e a qualidade das nanofibras é afetada positivamente. A metodologia da mistura por fusão não foi eficiente para dispersar as nanofibras de Pani na matriz de PE.
3

Análise cromatográfica/olfatométrica do potencial aromático de extratos naturais livres e incorporados a materiais pela impregnação supercrítica

Xavier, Vanessa Barbieri January 2016 (has links)
Made available in DSpace on 2016-04-25T11:22:46Z (GMT). No. of bitstreams: 1 000478310-Texto+Completo-0.pdf: 4214220 bytes, checksum: c994d11e326960f203b011fc18fb6a33 (MD5) Previous issue date: 2016 / The determination of the contribution of certain constituents to the global odor of a product has been the subject of interest to researchers. It is known that only a small part of the large number of volatile compounds present in a fragrant matrix contributes to the perception of its odor. In addition, these molecules do not contribute equally to the global odor profile of a sample, so a large relative concentration of a compound; do not necessarily correspond to a high intensity odor. Gas chromatography/olfactometry (GC/O) is analytic technic appropriate for studying such issues, since it enables the assessment of odor of each component of complex mixture through specific correlation with the compounds of interest. This is possible because the volatile components of the substances have perceived simultaneously by two detectors, one being the human olfactory system and the other the chromatography detector. The objective of this study is the project, development, implementation and validation of a hybrid equipment (GC/O) to olfatometric analysis and the use of it as tooling for analysis of natural extracts incorporated in different materials. The initial result of the work consisted of the olfactometer own, tested and validated for use in studies associated with this thesis. With the olfactometer, essential oils were analyzed of native species in order to assess the aromatic potential of these extracts and volatile compounds of honey as a way to develop and validate an alternative technique to identification source. With the results referent to the equipment and raw materials, there was made studies on the controlled release of volatile compounds impregnated in textiles by supercritical impregnation, using the gas chromatography/olfactometry as an analytical method. / A determinação da contribuição de determinados constituintes para o aroma global de um produto tem sido alvo de interesse de pesquisadores. Sabe-se que apenas uma pequena parte do grande número de compostos voláteis presentes em uma matriz perfumada contribui para percepção do seu aroma. Além disso, estes compostos não contribuem igualmente para o perfil do aroma global da matriz, portanto, uma grande concentração relativa de um determinado composto, não necessariamente correspondem a intensidades altas de aroma. A cromatografia gasosa/olfatometria (GC/O) é a técnica analítica indicada para estudar tais questões, pois permite a avaliação do aroma de cada componente de uma mistura complexa, através da correlação específica com os compostos de interesse; isso é possível porque os componentes voláteis das substâncias são percebidos simultaneamente por dois detectores, sendo um deles o sistema olfativo humano e o outro um detector cromatográfico. O objetivo deste estudo foi o desenvolvimento, implantação e validação de um equipamento híbrido (GC/O) para análises olfatométricas e emprego do mesmo como ferramental de análise de extratos naturais incorporados em materiais. Inicialmente, o olfatômetro foi construído, testado e validado, para uso em diferentes matrizes. Com o olfatômetro, foram analisados óleos essenciais de espécies nativas como forma de avaliar o potencial aromático destes extratos e compostos voláteis de méis como forma de propor e validar uma técnica alternativa de identificação de origem destes produtos. A partir dos resultados referentes ao equipamento e às matérias primas, realizou-se estudos sobre a liberação controlada de compostos voláteis impregnados em tecidos pela impregnação supercrítica, tendo como método de análise a cromatografia gasosa/olfatometria.
4

Análise cromatográfica/olfatométrica do potencial aromático de extratos naturais livres e incorporados a materiais pela impregnação supercrítica

Xavier, Vanessa Barbieri January 2016 (has links)
Made available in DSpace on 2016-04-23T12:26:44Z (GMT). No. of bitstreams: 1 000478310-Texto+Completo-0.pdf: 595 bytes, checksum: b090348aa6d00a23e00d7d95e2d4fcb8 (MD5) Previous issue date: 2016 / The determination of the contribution of certain constituents to the global odor of a product has been the subject of interest to researchers. It is known that only a small part of the large number of volatile compounds present in a fragrant matrix contributes to the perception of its odor. In addition, these molecules do not contribute equally to the global odor profile of a sample, so a large relative concentration of a compound; do not necessarily correspond to a high intensity odor. Gas chromatography/olfactometry (GC/O) is analytic technic appropriate for studying such issues, since it enables the assessment of odor of each component of complex mixture through specific correlation with the compounds of interest. This is possible because the volatile components of the substances have perceived simultaneously by two detectors, one being the human olfactory system and the other the chromatography detector. The objective of this study is the project, development, implementation and validation of a hybrid equipment (GC/O) to olfatometric analysis and the use of it as tooling for analysis of natural extracts incorporated in different materials. The initial result of the work consisted of the olfactometer own, tested and validated for use in studies associated with this thesis. With the olfactometer, essential oils were analyzed of native species in order to assess the aromatic potential of these extracts and volatile compounds of honey as a way to develop and validate an alternative technique to identification source. With the results referent to the equipment and raw materials, there was made studies on the controlled release of volatile compounds impregnated in textiles by supercritical impregnation, using the gas chromatography/olfactometry as an analytical method. / A determinação da contribuição de determinados constituintes para o aroma global de um produto tem sido alvo de interesse de pesquisadores. Sabe-se que apenas uma pequena parte do grande número de compostos voláteis presentes em uma matriz perfumada contribui para percepção do seu aroma. Além disso, estes compostos não contribuem igualmente para o perfil do aroma global da matriz, portanto, uma grande concentração relativa de um determinado composto, não necessariamente correspondem a intensidades altas de aroma. A cromatografia gasosa/olfatometria (GC/O) é a técnica analítica indicada para estudar tais questões, pois permite a avaliação do aroma de cada componente de uma mistura complexa, através da correlação específica com os compostos de interesse; isso é possível porque os componentes voláteis das substâncias são percebidos simultaneamente por dois detectores, sendo um deles o sistema olfativo humano e o outro um detector cromatográfico. O objetivo deste estudo foi o desenvolvimento, implantação e validação de um equipamento híbrido (GC/O) para análises olfatométricas e emprego do mesmo como ferramental de análise de extratos naturais incorporados em materiais. Inicialmente, o olfatômetro foi construído, testado e validado, para uso em diferentes matrizes. Com o olfatômetro, foram analisados óleos essenciais de espécies nativas como forma de avaliar o potencial aromático destes extratos e compostos voláteis de méis como forma de propor e validar uma técnica alternativa de identificação de origem destes produtos. A partir dos resultados referentes ao equipamento e às matérias primas, realizou-se estudos sobre a liberação controlada de compostos voláteis impregnados em tecidos pela impregnação supercrítica, tendo como método de análise a cromatografia gasosa/olfatometria.
5

Síntese integrada em condições brandas de zeólitas 4A e NaP1, a partir de cinzas de carvão, para o uso em detergente e descontaminação ambiental

Cardoso, Ariela Milbrath January 2012 (has links)
Made available in DSpace on 2013-08-07T18:54:52Z (GMT). No. of bitstreams: 1 000440622-Texto+Completo-0.pdf: 2553977 bytes, checksum: b11f8c29e33dc22a9196a011c9531918 (MD5) Previous issue date: 2012 / The main use of coal is the generation of electricity, which represents 41% of all electricity generated in the world. Coal burning power plants in the southern states of Brazil produce 3. 0x106 tons of ash per year. The present work aims the integrated synthesis of zeolites NaP1 and 4A under mild conditions using coal fly ash as raw material. These zeolites present industrial and environmental applications of great importance for the country, aiming at the minimization of environmental impacts and waste generated. For the synthesis of zeolites hydrothermal process was carried out with different concentrations of the NaOH in low cost glass reactor. The liquid/solid ratio, temperature, sources of aluminum, among other factors, was also investigated. Several techniques were used, to characterize the synthesized zeolite, such as SEM, XRD, XRF, CEC, among others. The best zeolitic products were used in the effluents treatment. Under the conditions used in this study NaP1 and 4A zeolites were obtained with CEC values of 2. 5 and 4. 5 meq g-1, respectively, indicating high conversions. The zeolite NaP1 proved been highly efficient in removing Mn and NH4+, from Acid Mine Drainage and Swine manure effluents, respectively, within the emission limits imposed by legislation. The results of this study indicate that the zeolite 4A is could be used in replacement of the polyphosphate in detergents. / O principal uso do carvão é a geração de eletricidade, o que representa 41% de toda a eletricidade gerada no mundo. A combustão do carvão nas usinas dos estados do sul do Brasil gera 3,0x106 toneladas de cinzas por ano. O presente trabalho visa a síntese integrada de zeólitas NaP1 e 4 A em condições brandas, utilizando cinzas volantes de carvão como matéria-prima. Estas zeólitas apresentam aplicações industriais e ambientais de grande importância para o país, visando a minimização dos impactos ambientais e os resíduos gerados. Para a síntese das zeólitas foi realizado processo hidrotérmico com diferentes concentrações de NaOH em reator de vidro de baixo custo. A relação L/S, temperatura, as fontes de alumínio, entre outros fatores, também foram investigados. Várias técnicas foram utilizadas, para caracterizar as zeólitas sintetizadas, tais como MEV, DRX, FRX, CTC, entre outras. Os melhores produtos zeolíticos foram utilizados no tratamento de efluentes. Sob as condições utilizadas neste estudo as zeólitas NaP1 e 4 A foram obtidas com valores de CTC de 2,5 e 4,5 meq g-1, respectivamente, indicando conversões elevadas. A zeólita NaP1 provou ser altamente eficiente na remoção de Mn e NH4+, de drenagem ácida de mina e efluentes de dejetos suínos, respectivamente, dentro do limites de emissões impostos pela legislação. Os resultados deste estudo indicaram que a zeólita 4 A pode ser utilizada em substituição dos polifosfatos na formulação de detergentes.
6

Determinação de cádmio e chumbo em sangue por espectrometria de absorção atômica com tubo aquecido na chama após combustão iniciada por microondas

Hoehne, Lucélia 25 July 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work a procedure for Cd and Pb determination by solid sampling flame furnace atomic absorption spectrometry after microwave induced combustion (MIC-FF-AAS) is used. Human blood samples were priory lyophilized, dried, ground, mixture with graphite, pressed and placed on a filter paper positioned on a quartz holder, that was introduced in a glass device inside a microwave oven. The microwave oven was modified making possible an oxygen flow for combustion step and to transport the combustion products to the AAS spectrometer. Ammonium nitrate solution 50% (w/v) was used to start the ignition step. Atomization was performed in a metallic tube heated into air and acetylene flame. Calibration was carried out using aqueous reference solutions pipetted into graphite pellets. After operational conditions optimization, the suitable parameters were: 20 mg of paper filter to start combustion with 40 μl of NH4NO3 50% (w/v), 1 l min-1 O2 flow rate and air and acetylene flow rates were 16 and 2 l min-1 for determination of Cd and Pb in lyophilized blood using tubes without for Cd and with 12 holes for Pb. At the chosen conditions it was possible the introduction of around 50 mg of sample and quantification limits of 20 ng g-1 and 2.2 μg g-1, for Cd and Pb, respectively. The obtained characteristic masses were 50 pg for Cd and 4.5 ng for Pb. No significant differences were observed when comparing the obtained results using the proposed procedure with certified reference materials values or with those obtained by inductively coupled plasma mass spectrometry, after acid digestion. The sample throughput was 15 determinations per hour, excluding previous steps until weighing step. / Neste trabalho foi utilizada uma técnica para análise de amostras sólidas por espectrometria de absorção atômica com tubo aquecido na chama após combustão iniciada por microondas (MIC-FF-AAS) para a determinação de cádmio e chumbo em sangue. Um tratamento inicial foi dado à amostra, sendo esta liofilizada, seca em estufa e moída. As amostras de sangue liofilizado foram prensadas, juntamente com grafite de alta pureza, na forma de comprimidos. Os comprimidos da amostra (sangue liofilizado + grafite) foram colocados sobre um papel de filtro e posicionados em um suporte de quartzo. O suporte foi colocado no interior de uma câmara de vidro adaptada no interior do forno de microondas do sistema MIC-FF-AAS. Solução de NH4NO3 50% (m/v) foi empregada como iniciador da combustão e um fluxo de oxigênio foi utilizado para a combustão e para o transporte dos vapores formados até o sistema de atomização. A atomização foi feita em um tubo metálico posicionado sobre a chama (ar e acetileno) de um espectrômetro de absorção atômica com chama. A calibração foi feita empregando-se soluções de referência adsorvidas em comprimidos de grafite. Após a avaliação das condições operacionais, os seguintes parâmetros foram escolhidos: combustão empregando 20 mg de papel de filtro, 40 μl de solução de NH4NO3 50% (m/v) e vazão de oxigênio de 1 l min-1, vazão de ar e acetileno de 16 e 2 l min-1 para a determinação de Cd e Pb em sangue liofilizado, uso de tubos metálicos sem furos na base (para Cd) e com 12 furos na base (para Pb). A técnica permite a introdução de até 50 mg de sangue tendo um limite de quantificação de 20 ng g-1 para Cd e 2,2 μg g-1 para Pb. A massa característica foi de 50 pg para Cd e 4,5 ng para Pb. Resultados concordantes foram obtidos entre a técnica de MIC-FF-AAS e os valores para materiais de referência ou com os obtidos pela técnica de espectrometria de massa com plasma indutivamente acoplado. A técnica permitiu uma freqüência de 15 determinações por hora (excluindo-se as etapas prévias até a confecção dos comprimidos com grafite).
7

Limpieza de matrices sólidas porosas de interés medioambiental con fluidos supercríticos.

Abaroudi, Kamal 04 April 2001 (has links)
En esta tesis, se ha intentado sustituir el uso de los solventes orgánicos clorados peligrosos con la técnica de la extracción supercrítica para la limpieza de piezas metálicas porosas. Se ha estudiado experimental y teóricamente la cinética de extracción de b-naftol impregnado en los poros de las piezas metálicas usando CO2 supercrítico puro y modificado variando la temperatura la presión, el caudal, el tamaño de partícula, la gravedad y el porcentaje del cosolvente. Como modelo matemático, se ha usado el modelo del núcleo sin reacionar, en este modelo aparecen 4 parámetros a justar: la solubilidad, el coeficiente de transferencia de materia, la difusividad efectiva y la dispersión axial. Para el caso de la solubilidas, se puede determinar experimentalmente o bine usando métodos totalmente predictivos. Como método experimental, se ha utilizado el método cuasi equilibrio en el cual se ha trabajado con un caudal bastante bajo que permite que el fluido se sature durante su tiempo de residencia en el extractor y luego se ha verificado la fiabilidad del método experimental y teóricamente estudiando la cinética de extracción del soluto. Para predecir la solubilidad el sólio en CO2 supercrítico puro, se ha empleado la teoría de la esfera rígida de van der Waals con el valor medio de la integral de la energía potencial intermolecular (a12) lo cual se ha conseguido a partir del ajuste de una serie de compuestos hidrocarburos de manera que se han encontrado que dicho parámetro varía muy poco con la presión, la temperatura y de un soluto a otro. Para predecir la solubilidad del sólido en CO2 supercritico modificado, se ha utilizado la ecuación de estado de P-R junto con las reglas de mezcla del fluido único de van der Waals de manera que se han determinado los parámetros de interacción binarios (k12, k13, k23) a partir del estudio de los sistemas binarios usando las reglas de mezcla de Wong Sandler (WS) y la combinación lineal de Vidal-Michelson (LCVM) junto con una teória de contribución de grupos (UNIFAC). Una vez se ha obtenido la solubilidad, se ha ajustado los datos experimentales de extracción para determinar el coeficiente de transferencia, la difusividad efectiva y la dispersión axial y luego se ha estudiado como varían estos parámetros con los variables citados anteriormente. Como parte final de esta tesis, se ha intentado usar la técnica de la extracción supercritica en la recuperación de un catalizador gastado durante la hidrogenación sucesiva de CDT en CDE.
8

Síntese e avaliação da atividade fotocatalítica do Ag2O/TiO na degradação de corante

Almeida, Wágner Moreira de 31 August 2012 (has links)
Made available in DSpace on 2015-09-25T12:19:48Z (GMT). No. of bitstreams: 1 Wagner Moreira de Almeida.pdf: 1432955 bytes, checksum: 9f9e1908144e3a096cc5d323e4c426a2 (MD5) Previous issue date: 2012-08-31 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Titanium dioxide (TiO2) shows significant catalytic, optical and electronic properties, being used as constitutional material to capacitors, pigments and solar cells, as well as, applied as catalyst for photodegradation of organic matter. Thus, this work aims to obtain TiO2 and Ag-doped TiO particles, under several calcinations temperatures and with different silver content, by means of the Polymeric Precursor Method. Also, evaluate its photocatalytic activities during the photooxidation of indigo blue dye. Therefore, all samples were characterized by Fourier transform infrared spectroscopy (FTIR), thermogravimetry analysis (TGA) and differential thermal analysis (DTA). Besides, the influence thermal treatment and the dopant metal over both oxides structures were investigated by X-ray diffraction (XRD). In general, the apparent kinetic constant suggests that TiO2 /(0.50%)Ag (700 ºC) sample leads to higher conversion of the dye, even under visible light irradiation. / O dióxido de titânio (TiO2) possui importantes propriedades catalíticas, eletrônicas, sendo utilizado na produção de capacitores, pigmentos, células solares e na degradação de poluentes orgânicos. No presente trabalho, foi realizado a síntese de catalisadores de TiO2 e TiO dopado com prata metálica a diferentes concentrações e temperaturas de calcinação, a partir do método dos precursores poliméricos, que proporciona um controle preciso da estequiometria e uma maior reprodutibilidade, para avaliar a atividade fotocatalítica na degradação do corante Índigo Blue sob radiação artificial visível. As amostras de TiO22 e Ag/TiO foram analisados por espectroscopia de infravermelho, termogravimetria (TG) e análise térmica diferencial (DTA). Foi realizado também o estudo da influência da temperatura de calcinação e porcentagem do dopante prata na evolução das fases cristalinas (anatase e rutilo), por meio de difração de raios X (DRX). Na cinética de degradação do corante índigo blue verificou-se, com relação aos valores da constante cinética aparente (k2), que a amostra de Ag0,50/TiO (700 ºC), apresentou maior eficiência de degradação na atividade fotocatalítica, a luz visível, o que é consistente com os resultados de DRX.
9

Efeito de agentes químicos no tratamento anaeróbio de efluentes / Effect of chemical agents on anaerobic wastewater treatment

Pires, Aline Mara Barbosa 05 May 2005 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-11-09T16:31:20Z No. of bitstreams: 1 texto completo.pdf: 760316 bytes, checksum: 6bd71fc605529a1d40fbaa95cad9c91c (MD5) / Made available in DSpace on 2016-11-09T16:31:20Z (GMT). No. of bitstreams: 1 texto completo.pdf: 760316 bytes, checksum: 6bd71fc605529a1d40fbaa95cad9c91c (MD5) Previous issue date: 2005-05-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A digestão anaeróbia representa uma alternativa viável para tratamento de efluentes de alta carga orgânica, como os gerados pelas indústrias de alimentos. Contudo, sua aplicação ainda é limitada devido ao conceito errôneo de que processos anaeróbios não são capazes de tolerar a toxicidade de produtos químicos que possam estar presentes em efluentes industriais. No caso da indústria de alimentos, a maioria das substâncias tóxicas origina-se dos sistemas de limpeza e sanificação como detergentes e sanificantes. Neste estudo avaliou-se o efeito de agentes químicos na eficiência de remoção de Demanda Química de Oxigênio (DQO), utilizando-se reatores anaeróbios em batelada tratando um meio sintético. Representantes de cada classe de agentes detergentes como alcalinos, ácidos, tensoativos e complexantes, foram avaliados isoladamente e na forma combinada, por meio de duas formulações: detergente básico e detergente ácido. Além disso, foram avaliados dois sanificantes químicos e combinações desses sanificantes com as formulações de detergente. As concentrações testadas foram definidas com base nas concentrações recomendadas em procedimentos de higienização e em fatores de diluição resultantes dos procedimentos de enxágüe. O acompanhamento da performance dos reatores foi realizado avaliando-se o pH e a DQO solúvel. Os sistemas contendo EDTA, hexametafosfato de sódio e hipoclorito de sódio não apresentaram efeito inibitório em nenhuma das concentrações avaliadas, enquanto 60 mg.L-1 de ácido peracético reduziu a eficiência do processo. Os surfactantes apresentaram efeitos diferenciados: a digestão anaeróbia foi inibida por concentrações acima de 150 mg.L-1 de dodecil sulfato de sódio (surfactante aniônico), enquanto Tween 80 (surfactante não iônico) estimulou o processo em concentrações de 15 mg.L-1. Os efeitos inibitórios mais relevantes foram atribuídos ao agente alcalino (hidróxido de sódio) e ao agente ácido (ácido nítrico) devido à grande influência do pH na performance do sistema. Não foi observado sinergismo entre os componentes das formulações de detergente, predominando o comportamento do agente principal de cada formulação, em todas as concentrações testadas. A avaliação das associações entre detergentes e sanificantes confirma a relevância do efeito do pH sobre os microrganismos anaeróbios e sobre a atividade antimicrobiana dos sanificantes químicos avaliados. / Anaerobic digestion represents a feasible option for the treatment of high strength organic effluents such as food-processing industries wastewater. However, its application is still limited due to a common misconception that anaerobic process cannot tolerate toxicity of chemical products that may be contained in industrial wastewaters. In the food industry, most toxic substances come from cleaning and sanitizing systems like detergents and disinfectants. This study evaluated the effect of chemical agents on efficiency of chemical oxygen demand (COD) removal in batch anaerobic reactors treating a synthetic media. Groups of each detergent class as alkaline, acid, surfactants and chelating agents, were evaluated separately and mixed using two formulations: alkaline detergent and acid detergent. Moreover, two chemical sanitizers and mixtures of these sanitizers with the detergent formulations were evaluated. The evaluated concentrations were defined based on concentration recommended in sanitation procedures and dilution factors by rinse procedures. The performance of the reactors was evaluated by pH and soluble COD. Systems containing EDTA, sodium hexametaphosphate and sodium hypochlorite did not manifest inhibition at any concentration evaluated while peracetic acid at 60 mg.L-1 reduced the performance of the process. Surfactants showed different effects: anaerobic digestion was inhibited by sodium dodecylsulfate (anionic surfactant) at concentrations above 150 mg.L-1 while Tween 80 (non-ionic surfactant) stimulated the process at 15 mg.L-1. The greatest inhibitions were attributed to alkaline agent (sodium hydroxide) and acid agent (nitric acid) due to intense influence of pH on system performance. There was no synergism among components of detergent formulations with the behavior of the main agent of each formulation predominating, at all evaluated concentrations. The assessment of detergents and sanitizer mixtures confirms magnitude of effect of pH on anaerobic microorganisms and antimicrobial activities of evaluated chemical sanitizers.

Page generated in 0.0283 seconds