• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement, étude de performances et intégration de sondes thermiques pour la caractérisation de l'encrassement d'échangeurs tubulaires à courants croisés

Perez, Laetitia 12 1900 (has links) (PDF)
Depuis la fin des années 1970, les échangeurs de chaleur ont connu de nouvelles applications liées à la nécessité d'optimiser les dépenses énergétiques. L'encrassement de tels échangeurs est l'une des causes principales de leur perte d'efficacité thermique au cours de leur utilisation. En effet, l'encrassement constitue un problème économique et technologique majeur et fait intervenir des phénomènes physiques complexes. En dépit des efforts déployés depuis ces dernières décennies, les dispositifs de détection et de suivi de l'encrassement existants sont encore loin de renseigner sur le transfert de chaleur et de prendre en compte les phénomènes de dépôt mis en jeu. Ainsi, le parti pris de notre étude a été de concevoir un capteur thermique le plus représentatif possible des conditions d'utilisation réelles afin d'établir un programme d'entretien efficace. A cet effet, deux capteurs localisés originaux, d'une technologie simple, adjoints à un traitement des données adapté, ont été développés. Ne perturbant que très peu les conditions auxquelles ils sont soumis, ils permettent d'obtenir des informations précises quasi instantanées sur les paramètres représentatifs du degré d'encrassement des échangeurs. Bien que les méthodes développées lors de cette étude soient adaptables à d'autres configurations, le choix, incontestablement restrictif, de travailler sur l'encrassement particulaire des échangeurs tubulaires à courants croisés, a été fait. Le premier capteur, doté d'une excitation thermique interne, permet d'estimer non seulement le coefficient d'échange convectif mais aussi l'épaisseur du dépôt à partir d'une méthode d'estimation robuste en régime transitoire. Le second capteur permet d'estimer la répartition spatiale du coefficient d'échange convectif ainsi que celle de l'épaisseur de dépôt. Ces capteurs permettent d'envisager de nouvelles perspectives d'études in situ d'encrassement en milieu industriel. Ils constituent un outil privilégié de maintenance prédictive.
2

Modélisation des échanges thermiques et radiatifs en environnement urbain à très haute résolution spatiale : aide à l'interprétation des mesures par télédétection infrarouge / Modelling of radiative heat exchange in urban environments with very high spatial resolution : assistance in the interpretation of measurements by infrared remote sensing

Lalanne, Nicolas 21 July 2015 (has links)
La consommation énergétique en France a pour origine principale le secteur résidentiel et tertiaire. En environnement urbain, l’habitat est encore principalement ancien, avec des déperditions importantes. L’amélioration des performances énergétiques passe par la quantification des pertes, basée sur une méthode globale de mesure par caméra infrarouge à haute résolution spatiale.L’interprétation des images obtenues nécessite une description des termes radiatifs composant le signal, pour cela un simulateur original est mis au point. A partir d’une scène tridimensionnelle maillée, le champ de température est calculé pour les parois 1D et pour les ponts thermiques 2D, par le programme thermique développé à cet effet, SUSHI qui s’appuie sur un pré-calcul d’éclairement solaire et un pré-calcul de réponse indicielle 2D. Le signal du capteur infrarouge est alors modélisé en adaptant le code radiatif MOHICANS.Cette chaîne logicielle a l’originalité de proposer une fusion efficace des simulations de la réponse dynamique en température et en luminance de zones présentant un transfert 1Dà travers la paroi et de zones présentant un transfert 2D.La mise en œuvre de la campagne expérimentale BATIR a permis de mesurer le comportement thermique d’une façade de bâtiment et de son environnement radiato-convectif. Une validation ponctuelle des températures calculées par SUSHI a été réalisée par confrontation à une mesure par thermocouple. Des caméras infrarouges ont été mises en œuvre afin de collecter la luminance issue de la façade étudiée en bande II et III. Les luminances calculées par MOHICANS sont comparées à ces acquisitions, et valident la chaîne logicielle à ce niveau. / The main origin of the energy consumption in France is the residential and commercial sector. In urban environment, housing is mostly old, which means high heat losses. The improvement of energy performances requires the quantification of heat losses. This quantification may be based on a global measurement by an infrared camera with high spatial resolution.The infrared image interpretation requires a description of the radiative terms that make up the signal. For that purpose, a novel simulator is developed. The temperature field is calculated from a meshed three-dimensional scene composed of 1D walls and 2D thermal bridges. This operation is realized by the developed thermal software SUSHI, which is based on solar irradiance pre-computation and on 2D unitary response pre-computation. The software uses as input environmental data measured in the field. The infrared sensor signal is then modelled by adapting the radiative program MOHICANS. This software chain has the distinct advantage of an efficient fusion of dynamic response simulations of temperature and radiance, for areas with unidirectional and 2D heat transfer.The experimental campaign BATIR was set-up for measuring the thermal behavior of a building façade and its convective and radiative environment. A local validation of temperature calculation by SUSHI was realized through a comparison with thermocouple measurement results. Infrared cameras were operated in order to collect the radiance coming from the analyzed façade in band II and III. The radiances calculated by MOHICANS were compared with these acquisitions in order to validate the software chain at this level.
3

Innovative non-destructive methodology for energy diagnosis of building envelope / Méthodologies innovantes non destructives appliquées au diagnostic énergétique de l'enveloppe du bâtiment

Yang, Yingying 18 December 2017 (has links)
Le secteur du bâtiment représente 35% des la consommations énergétiques dans les pays membres de l’agence international de l’énergie en 2010 et 39,8% aux Etats-Unis en 2015. Plus de 50% de cette consommation a été utilisée pour la production de chaleur et de froid. Néanmoins cette consommation peut être réduite par l'amélioration la performance énergétique du bâtiment. La performance thermique de l'enveloppe du bâtiment joue un rôle primordial. Par conséquent, le diagnostic thermique de l'enveloppe du bâtiment est nécessaire pour, par exemple, la réception de nouvelles constructions, l'amélioration de la performance énergétique des anciens bâtiments, ainsi que la vente et la location des logements. Pourtant, il existe très peu de méthodes quantitatives pour la caractérisation des parois épaisses. L'objectif de cette étude est d'explorer des méthodes quantitatives innovantes de diagnostic thermique de l'enveloppe du bâtiment. Des mesures expérimentales ont été réalisées en laboratoire (à l’IFSTTAR à Nantes) et in situ (à l’IUT de Bordeaux). Différents capteurs et méthodes d'instrumentation ont été étudiés pour mesurer la densité de flux et la température de surfaces des parois, afin de procurer des recommandations pour le choix des capteurs ainsi que des protocoles de traitement de données. A partir des données mesurées (température et densité de flux des surfaces de l'enveloppe), trois approches numériques ont été proposées pour estimer des paramètres thermiques des parois multicouches épaisses : par méthode inverse, par réponse à un échelon et par réponse impulsionnelle. En outre, une méthode innovante non-destructive utilisant la rayonnement térahertz a été étudiée. Les mesures ont été effectuées au sein du laboratoire I2M. Cette méthode permet de caractériser le coefficient d'absorption des matériaux constructifs ordinaires comme isolation, plâtre, béton, bois… Elle pourrait postérieurement être combinée avec une méthode thermique pour apporter des informations complémentaires. / Buildings represent a large share in terms of energy consumption, such as 35% in the member countries of IEA (2010) and 39.8% in U.S. (2015). Climate controlling (space heating and space cooling) occupies more than half of the consumption. While this consumption can be reduced by improving the building energy efficiency, in which the thermal performance of building envelope plays a critical role. Therefore, the thermal diagnosis of building envelope is of great important, for example, in the case of new building accreditation, retrofitting energy efficiency of old building and the building resale and renting. However, very few diagnostic methods exist for the characterization of thick walls. The present measurement standards that based on steady state heat transfer regime need a long time (several days). The classical transient technologies, such as flash method, are difficult to implement on the walls because of the large thickness of walls and the complex conditions in situ. This thesis aims to explore innovative methodologies for thermal quantitative diagnosis of building envelope. Two experimental cases were carried out: one is in laboratory (IFSTTAR, Nantes) and the other is in situ (IUT, Bordeaux). Different sensors and instruments were studied to measure the wall heat flux and surface temperature, and provided some guidelines for the choice of sensors and data processing protocols as well. Using these measured data, three estimation approaches were proposed to estimate the thermal parameters of the multilayer thick wall: pulse response curve method, step response curve method and inverse method, which can be applied for different diagnostic situations. In addition, an innovative NDE (non-destructive evaluation) method using terahertz (THz) radiation was also investigated. Measurements were carried out in I2M laboratory to characterize the absorption coefficient of standard building materials (insulation, plaster, concrete, wood ...). This THz method can be combined with a previous thermal method to provide some complementary information.

Page generated in 0.0494 seconds