• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 234
  • 9
  • Tagged with
  • 244
  • 244
  • 188
  • 182
  • 154
  • 82
  • 79
  • 75
  • 70
  • 62
  • 54
  • 54
  • 47
  • 46
  • 44
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Sistema de aquisição de dados para monitoramento de malha de terra energizada

SOUSA, Kleiber Tenório de 18 November 2015 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-03-28T12:22:30Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_SistemaAquisicaoDados.pdf: 3177228 bytes, checksum: 3408b379c597bb67d4cb3bf470a0812a (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-28T13:36:45Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_SistemaAquisicaoDados.pdf: 3177228 bytes, checksum: 3408b379c597bb67d4cb3bf470a0812a (MD5) / Made available in DSpace on 2017-03-28T13:36:45Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_SistemaAquisicaoDados.pdf: 3177228 bytes, checksum: 3408b379c597bb67d4cb3bf470a0812a (MD5) Previous issue date: 2015-11-18 / O bom desempenho do sistema de aterramento de subestações e de usinas geradoras é uma condição essencial para que tais plantas possam operar dentro dos padrões de qualidade estabelecidos. Portanto, um sistema de monitoramento contínuo da malha de aterramento é uma ferramenta importante para auxiliar as equipes técnicas na identificação de falhas que afetem a operação dos Sistemas Elétricos de Potência. Alguns dos métodos tradicionais de medição nas malhas de aterramento necessitam do desligamento das instalações. No entanto, os contratos de concessão preveem penalidades por indisponibilidade da Geração e Transmissão, de modo que a adoção de procedimentos de avaliação constante do sistema de aterramento, sem o desligamento das instalações é essencial. Atendendo a essas especificações, esta Dissertação apresenta o desenvolvimento de um sistema embarcado de aquisição de sinais de tensão e corrente em pontos selecionados da malha de aterramento. Outro componente do sistema proposto é um software capaz de gerenciar a rede formada pelos diversos instrumentos de medição, organizar as informações coletadas em uma base de dados e produzir relatórios de acompanhamento das condições de operação da malha de aterramento. Um aspecto importante do sistema é a adoção da tecnologia de redes sem fio para comunicação entre um computador servidor e o conjunto de instrumentos de medição. Os resultados obtidos experimentalmente reforçam a contribuição do sistema desenvolvido e encorajam novos esforços de aperfeiçoamento. / The good performance of grounding system in substations and generating plants is an essential condition for their operation according with established quality standards. Therefore a continuous monitoring system for grounding grid is an important tool to aid technical teams to identify failed zones that depreciate the Power Systems operation. Some traditional measuring methods in grounding grids need the power system shutdown. However the concession contracts allow penalties for the unavailability of generation and transmission facilities. Therefore the constant adoption of grounding grid evaluation without the plant shutdown is important. Having these specifications as target this Dissertation presents an embedded system development for voltage and current measurement. Another proposed system component is the software to manage the measuring network and organize the collected information in a database to produce grounding system operation reports. An important aspect of the system is the adoption of wireless network technology to data transfer between each measuring instrument and a web server installed in the power plant operation center. The experimentally obtained results reinforce the system contribution and encourage new developments.
242

Estudos dos efeitos das descargas atmosféricas nos índices de desempenho da subestação de Vila do Conde e subestação de Marabá

SANTOS, Luciano Silva dos 10 May 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-04-27T14:05:39Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-05-04T12:57:18Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) / Made available in DSpace on 2017-05-04T12:57:18Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) Previous issue date: 2016-05-10 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este trabalho tem como objetivo apresentar os efeitos de descargas atmosféricas nos índices de desempenho na subestação de Vila do Conde (SE VDC) e de Marabá (SE MB), onde estão situadas na região norte, no estado do Pará, integrando o Sistema Norte - Nordeste de Transmissão da ELETRONORTE, estando interligadas às Usinas Hidrelétrica de Tucuruí (UHE Tucuruí). Foram estudadas, estabelecendo as relações entre as informações meteorológicas cedidas pelo SIPAM e dados fornecidos pelo centro de operações da Eletronorte no período de 2005 a 2013 de forma a determinar os efeitos nocivos das descargas atmosféricas, as quais são responsáveis pela intensificação de interrupções no fornecimento de energia elétrica. A análise por restrita à área de atuação da Eletronorte SE VDC e SE MB. O estudo desenvolvido evidência os desligamentos por descargas atmosféricas na linha de transmissão VDC/CASTANHAL de 230 KV e no disjuntor de 500 KV VCDJ7-08 e linha de transmissão MB/Imperatriz de 500 KV. Os resultados demonstram que a incidência de um raio pode causar surtos diretos e indiretos em linhas de transmissão e subestações de alta potência. Neste contexto justifica o estudo de formas eficientes de prevenção, sendo uma das finalidades deste trabalho. / This paper aims to present the effects of lightning in the performance indices in Vila do Conde substation (SE VDC) and Maraba (SE MB), which are situated in the north, in the state of Pará, integrating the North System - Eletronorte Transmission northeast, being connected to the Tucuruí Hydroelectric Power Plants (HPP Tucuruí). They were studied, establishing relations between the weather information provided by the SIPAM and data provided by central Eletronorte's operations in the period 2005-2013 in order to determine the harmful effects of lightning, which are responsible for the intensification of supply interruptions electricity. The analysis restricted to the area of operation of Eletronorte SE and SE VDC MB. The study developed evidence disconnections by lightning on transmission line VDC / CASTANHAL 230 KV and 500 KV breaker VCDJ7-08 and transmission line MB / Empress of 500 KV. The results demonstrate that a lightning strike may cause direct and indirect surges in transmission lines and high power substations. In this context it justifies the study of efficient forms of prevention, one of the purposes of this work.
243

Sistema inteligente de iluminação de estado sólido com controle remoto e análise de parâmetros da rede elétrica

Soares, Guilherme Marcio 25 June 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-02-05T17:06:52Z No. of bitstreams: 1 guilhermemarciosoares.pdf: 5349685 bytes, checksum: 1085aed638a3213e03844d5e5e68f7d1 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-02-26T11:52:22Z (GMT) No. of bitstreams: 1 guilhermemarciosoares.pdf: 5349685 bytes, checksum: 1085aed638a3213e03844d5e5e68f7d1 (MD5) / Made available in DSpace on 2016-02-26T11:52:22Z (GMT). No. of bitstreams: 1 guilhermemarciosoares.pdf: 5349685 bytes, checksum: 1085aed638a3213e03844d5e5e68f7d1 (MD5) Previous issue date: 2014-06-25 / Este trabalho propõe um sistema inteligente de iluminação pública utilizando diodos emissores de luz (LEDs). Neste âmbito, é proposta uma topologia para o acionamento dos LEDs com controle de intensidade luminosa. Além disso, funções adicionais são propostas de modo a expandir o conjunto de funcionalidades da luminária. Para o acionamento dos LEDs foi desenvolvido um conversor baseado na topologia Ćuk operando em modo de condução descontínuo (DCM) com um interruptor estático em série com a carga, sendo uma solução para o acionamento de LEDs de estágio único. Deste modo, este conversor foi projetado para desempenhar simultaneamente as funções de correção do fator de potência e controle da potência na carga. Através da análise da resposta fotométrica dos diodos emissores de luz perante ondulações de baixa frequência em sua corrente, foi possível criar uma metodologia de projeto que evita o uso de capacitores eletrolíticos no circuito de acionamento dos LEDs, aumentando assim a confiabilidade do sistema. A modelagem e o controle do conversor também foram feitas e estão mostradas no trabalho. De modo a controlar e gerenciar o sistema eletrônico da luminária, foi proposta uma arquitetura baseada no microcontrolador TM4C123GE6PM. Este sistema digital é responsável ainda por promover outras funcionalidades como controle automático de intensidade luminosa, proteção do circuito e ainda monitoramento de parâmetros de qualidade de energia da tensão de entrada do conversor, tais como afundamentos e elevações. A fim de avaliar experimentalmente o sistema proposto, foram desenvolvidos um programa de computador capaz de gerenciar as funcionalidades da luminária e um protótipo de 70W deste equipamento. Os resultados experimentais obtidos mostraram um bom desempenho tanto do circuito de acionamento dos LEDs, como das funcionalidades da luminária. / This paper proposes a smart lighting system based on light-emitting diodes (LEDs) for street lighting applications. In this context, a power converter with dimming capability was designed. Furthermore, additional functions are proposed in order to expand the feature set of the luminaire. To drive the LEDs, a topology based on Ćuk converter operating in discontinuous conduction mode (DCM) with an electronic switch in series with the load was proposed. This converter was designed to perform simultaneously the functions of power factor correction and power control, being a single-stage LED driver solution. By analyzing the LEDs photometric response due to low-frequency current ripple, a design methodology that avoids the use of electrolytic capacitors in the proposed converter was developed. The modeling and control of the converter were also done in order to ensure that the system is always operating within the desired specifications. To control and manage the electronic system of the luminaire, it was developed an architecture based on the microcontroller TM4C123GE6PM. Beside the aforementioned functions, this digital system was designed aiming the promotion of other features, such as automatic dimming, protection of the driver and even monitoring some power quality parameters related to the input voltage, such as sags and swells. In order to experimentally evaluate the proposed system, a software, able to manage the luminaire functionalities, and a 70W prototype were built. The experimental results demonstrated a good performance of the LED driver as well as the functionalities of the proposed luminaire.
244

Método híbrido baseado no algoritmo k-means e regras de decisão para localização das fontes de variações de tensões de curta duração no contexto de Smart Grid / Hybrid method based on k-means algorithm and decision rules for short-duration voltages source location in the context of smart grid

Fábbio Anderson Silva Borges 07 July 2017 (has links)
No contexto de Smart Grids, determinar a correta localização das fontes causadoras de Variação de Tensão de Curta Duração (VTCD) não é uma tarefa simples, devido à curta duração destes eventos e também, por sua rápida propagação nas redes de distribuição de energia elétrica. Neste sentido, esse trabalho apresentou um método híbrido recursivo baseado em ferramentas da área de aprendizado de máquinas (algoritmo de agrupamento e base de regras), o qual é capaz de localizar as fontes de VTCD, a partir da análise dos das características dos distúrbios disponibilizadas pelos smart meters instalados no sistema. Assim, o trabalho destinouse ao desenvolvimento de uma plataforma em hardware para aquisição, detecção e classificação dos distúrbios, através de um Sistema Operacional de Tempo Real. Em seguida o algoritmo de agrupamento (k-means) agrupou os dados dos medidores de forma a definir dois clusters, onde um deles correspondeu aos medidores que estão longe da região que ocorreu o distúrbio e o outro, correspondeu aos medidores que estavam localizados próximos da região de ocorrência do distúrbio. Na segunda etapa, um sistema baseado em regras determinou qual dos clusters abrangeu o nó de origem. No entanto, quando o algoritmo determinou uma região muito grande, essa região é introduzida recursivamente, como entrada da metodologia desenvolvida, para refinar a região de localização. O sistema resultante foi capaz de estimar a região de localização com uma taxa de acerto acima de 90%. Assim, o método teve sua concepção adequada ao empregado nos centros de controle e operações de concessionárias de energia elétrica, visando apoiar a decisão do corpo técnico para que ações corretivas fossem estabelecidas de forma assertiva. / In the Smart Grids context, the correct location of short-duration voltage variations sources is not a trivial task, because of the short duration of these events and for rapid propagation in the distribution feeder. In this sense, aiming to develop a recursive hybrid method based on machine learning area tools (clustering algorithm and rule base) that is able to locate the sources of short-duration voltage variations, it was used data from smart meters installed along the distribution feeder. The recursive hybrid method, as input, received the disturbance characteristics provided by the meters installed in the system. Thus, this thesis aimed to development of a measurement hardware for signal acquisition, detection, classification through a realtime operating system. Then, k-means clustering algorithm grouped the meters data in order to define two clusters, where one of them corresponded to the meters that were distant from the region that occurred the disturbance and the other one corresponded to the meters, which were located near to the disturbance occurrence region. In a second step, a rule-based system determined which of the clusters corresponded to the source node. When the algorithm determined a very large region, that region was recursively introduced as input of the developed methodology to decrease its size. The resulting system was able to estimate the location region with a accuracy above 90%. Therefore, this method showed a suitable design for employment by operation control centers of power sector concessionaires, aiming to support technical staff decision to stablish assertive corrective actions.

Page generated in 0.0508 seconds