81

Análise de requisitos técnicos para ilhamento intencional de geradores síncronos distribuídos / Analysis of technical requirements for intentional islanding of distributed synchronous generators

Lima, Rogério Lúcio 09 August 2013 (has links)
Havendo qualquer distúrbio em um determinado sistema de distribuição de energia elétrica na presença de geradores distribuídos (GDs), é procedimento habitual exigido pelas concessionárias a desconexão destes na intenção de evitar a formação de um sistema ilhado eletricamente sustentado. Este procedimento tem como objetivo evitar maiores danos tanto ao sistema elétrico como um todo, principalmente ao próprio gerador distribuído, bem como às pessoas envolvidas na manutenção desse sistema. Entretanto, esse fato diminui consideravelmente as contribuições do conceito de geração distribuída à melhoria da qualidade dos serviços de fornecimento de energia elétrica por parte das concessionárias. Neste contexto, este trabalho possui como objetivo analisar os requisitos técnicos necessários para viabilizar a operação ilhada dos geradores distribuídos. Sabendo que a maioria das cargas presentes em um sistema de distribuição é dependente dos níveis de tensão e frequência da energia de suprimento, a análise e o monitoramento dessas grandezas antes e durante o ilhamento deverão ocorrer de forma que não se perca a estabilidade da rede ilhada. Para isto, devem ser avaliadas alterações nos métodos de operação e controle dos geradores distribuídos, de maneira a atender os requisitos técnicos necessários para manter a tensão e a frequência dentro dos parâmetros de qualidade de energia elétrica. Foram propostos quatro índices de desempenho para avaliar a qualidade da energia elétrica no sistema ilhado. Os resultados obtidos demonstram a necessidade de efetuar ações corretivas eficientes para manter o sistema elétrico ilhado operando dentro dos padrões aceitáveis de qualidade de energia elétrica. Foram investigadas soluções potenciais e viáveis para garantir a operação da ilha estável e com qualidade da energia elétrica. Além disso, observou-se que cargas dependentes da tensão podem influenciar significativamente a capacidade do GD em formar de ilhas estáveis. / If disturbances occur in a power distribution systems in the presence of distributed generators (DGs), a common practice required by utilities is to disconnect such generators, aiming at avoiding a self-sustained energized island. This procedure is required on order to prevent damage to the whole distribution system, mainly the DG, and to the utility maintenance personnel, as well. However, this requirement may decrease the possible contributions of the distributed generation concepts to the quality of the power supply. In this context, this work aims at analyzing the technical requirements related to make DGs islanded operation feasible. Since most of the loads are dependent on the supply voltage and frequency, the analysis and monitoring of such quantities before and after an islanding event should occur in such a way that the stability of the energized island is granted. To reach such a goal, changes in the DG control modes must be assessed, so that the technical requirements necessary to keep voltage and frequency within statutory limits are fulfilled. Four performance indices have been proposed to assess the power quality in the islanded system. The results have shown the need to perform efficient corrective actions to ensure reliable islanded operation. Moreover, it was observed that voltage-dependent loads may influence the DG capability to sustain stable islands.
82

Modelagem de lâmpadas de descarga: uma análise de desempenho considerando parâmetros de qualidade da energia / Discharge lamps modeling: a performance analysis considering power quality parameters

Andreoli, André Luiz 08 April 2011 (has links)
Este trabalho apresenta pesquisa relativa à modelagem de lâmpadas de descarga. A metodologia desenvolvida fornece meios de se construir modelos baseados em ferramentas inteligentes, especificamente através de redes neurais artificiais, de forma a representar o dispositivo com características que descrevam seus aspectos operacionais, bem como o comportamento de tais dispositivos diante de eventos relacionados à qualidade da energia elétrica. Um modelo matemático do conjunto lâmpada-reator, caracterizado como carga não-linear foi implementado inicialmente através da ferramenta SIMULINK®, integrante do pacote de software MATLAB®, e os resultados de simulações obtidas com este modelo são apresentados e comparados com os dados de operação obtidos experimentalmente, servindo como base de modelo para a lâmpada de descarga estudada e ponto de partida para a modelagem baseada em ferramentas computacionais inteligentes. Como contribuição, foi proposta a arquitetura de um modelo baseado em um conjunto de redes neurais artificiais destinado a representar a operação do conjunto lâmpada de descarga e reator. Empregando a massa de dados obtida através de ensaios realizados em diversas condições operacionais, e com o auxílio do pacote de software MATLAB®, realizou-se o treinamento de duas redes neurais artificiais que em conjunto foram capazes de representar com elevado grau de fidelidade o comportamento de uma lâmpada de descarga, incluindo as respostas transitórias a eventos relacionados à qualidade da energia elétrica. Comparado com o modelo matemático, o modelo neural proposto demonstrou maior facilidade de aplicação e boa representação do dispositivo e exigiu esforço computacional consideravelmente menor para simulações envolvendo grandes períodos de tempo e elevado número de dispositivos. Além destas vantagens, a metodologia adotada possibilita a obtenção de modelos de outras famílias de lâmpadas de descarga a partir de dados experimentais apenas, sem necessidade de conhecimento dos dados físicos e construtivos do dispositivo. O elevado desempenho do modelo obtido permitiu a simulação de conjuntos de lâmpadas de descargas inseridos em um sistema de distribuição em tempos de simulação muito menores que os exigidos pelo modelo matemático, justificando sua aplicação nas representações desta família de cargas inseridas nos sistemas elétricos de potência. A representação do comportamento do dispositivo frente a distúrbios de qualidade da energia também se mostrou como uma ferramenta útil para estudos mais complexos no sistema de distribuição. / This work presents research related to the modeling of discharge lamps. This methodology made possible to build models based on intelligent tools, specifically artificial neural networks, to represent the device characteristics concerning operational aspects as well as the behavior of such devices facing power quality events. The mathematical model of a lamp-reactor, characterized as an non-linear load, was implemented using SIMULINK® toolbox, part of the software MATLAB®. The simulation results obtained from this model are compared with data obtained experimentally, serving as a base model for discharge lamps as well as a starting point for the modeling tools based on computational intelligence. As a contribution, an architecture of a model based on artificial neural networks designed to represent the operation of the discharge lamp and reactor was proposed. Employing the data obtained from tests performed under various operating conditions, and with the aid of the software MATLAB®, the training of two neural networks was performed. These networks were able to represent with high fidelity the behavior a discharge lamp, including the response to transient events related to power quality. Comparing to the mathematical model, the neural model demonstrated greater adaptation and good representation of the device and required a considerably lower computational effort for simulations involving large periods of time and a great number of devices. Besides these advantages, the methodology allows to obtain models from other families of discharge lamps from experimental data only, without the knowledge of the physical data of the device. The high performance of the neural model allowed the simulation of a group of discharge lamps in a distribution system with simulation time much smaller than those required by the mathematical model, justifying its application in electric power systems. The representation of such a device facing power quality disturbances also proved to be a useful tool for more complex studies in a distribution system.
83

Utilização da Transformada de Fourier Janelada para caracterização de distúrbios na qualidade da energia elétrica / The use of the Windowed Fourier Transform for the characterization of disturbances in power quality

Souza, Silvio Aparecido de 31 March 2004 (has links)
Este trabalho apresenta um estudo da aplicação da Transformada de Fourier Janelada à Qualidade da Energia Elétrica. Esta abordagem procura, pela implementação de um algoritmo computacional, detectar, localizar e classificar eventuais distúrbios que ocorrem em um determinado Sistema Elétrico. Da situação atual, tem-se que variações nas formas de ondas dos sinais de tensão como elevação, afundamento e interrupção de tensão, oscilações transitórias e ruídos, são freqüentes, chamando a atenção para a qualidade da energia elétrica fornecida pelas concessionárias. A análise de tais fenômenos, que normalmente é descrita no domínio do tempo (resolução de equação diferencial) ou no domínio da freqüência (através da Transformada de Fourier), pode agora ser analisada simultaneamente em ambos os domínios do tempo e da freqüência, dispondo-se da Transformada de Fourier Janelada. As janelas utilizadas para esta finalidade foram as de Hanning, retangular e a de Kaiser. Para esta análise em específico, a simulação dos diversos distúrbios ocorridos no sistema de distribuição foi realizada através do software ATP - Alternative Transients Program - cujas características seguem corretamente um sistema real da concessionária CPFL - Companhia Paulista de Força. Os testes efetuados mostraram que a Transformada de Fourier Janelada possui uma grande potencialidade quanto à sua aplicação na avaliação da qualidade da energia elétrica. / This dissertation presents a study of Windowed Fourier Transform applied to Power Quality. By the implementation of a computational algorithm, this approach aims to detect, locate and classify disturbances that may occur in Power Systems. Variations in voltage waveforms, such as sag, swell, interruption, oscillatory transient and noise have became frequent in electric systems, attracting the attention to the power quality supplied. The analysis of such phenomena, which is usually described either in the time domain (differential equation resolution) or in the frequency domain (Fourier Transform), can now be analyzed simultaneously in both domains: time and frequency, by the windowed Fourier Transform. The windows used to provide this information are the Hanning, rectangular and Kaiser. The simulation of the diverse disturbances occurred in the distribution system was accomplished by means of ATP software - Alternative Transients Program - whose characteristics correctly follow a real distribution system of CPFL electric utility. The tests show the windowed Fourier Transform has a great potentiality when applied to evaluate the power quality.
84

Análise de supraharmônicos em equipamentos eletrônicos e caracterização utilizando a transformada wavelet / Analysis of supraharmonics in electronic equipment and characterization using the wavelet transform

RODRIGUES, Carlos Eduardo Moreira 10 September 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-10-16T14:59:25Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Análisesupraharmônicosequipamentos.pdf: 6997766 bytes, checksum: c986065c4af63643d869b704982eb088 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-10-16T14:59:52Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Análisesupraharmônicosequipamentos.pdf: 6997766 bytes, checksum: c986065c4af63643d869b704982eb088 (MD5) / Made available in DSpace on 2018-10-16T14:59:52Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Análisesupraharmônicosequipamentos.pdf: 6997766 bytes, checksum: c986065c4af63643d869b704982eb088 (MD5) Previous issue date: 2018-09-10 / Esta dissertação objetiva analisar a emissão, a propagação e a interação entre equipamentos envolvendo componentes harmônicas que possuem frequência na faixa entre 2 kHz e 150 kHz, denominadas supraharmônicos. A literatura especializada já reportou a emissão de supraharmônicos por equipamentos eletrônicos como lâmpadas fluorescentes, lâmpadas LED, inversores de frequência e nobreaks, além de impactos relacionados ao aquecimento de cabos e terminações, ruído acústico e interferência em sistemas PLC (Power Line Communication). No presente trabalho, foram realizadas campanhas de medição, em ambiente laboratorial, em inversores de frequência e um conjunto de lâmpadas LED. As medições se dividiram em dois grupos distintos: com os equipamentos conectados à rede elétrica e a uma fonte eletrônica trifásica, com o objetivo de verificar as ordens e os níveis, tanto das emissões provenientes dos equipamentos, quanto da distorção emitida pela própria fonte eletrônica, além da interação entre a fonte e os equipamentos alimentados. Foram empregadas a Transformada de Fourier e a Transformada Wavelet Packet para efetuar a análise e caracterização das distorções observadas. As medições mostraram uma contribuição significativa dos equipamentos observados e da fonte eletrônica para a emissão de supraharmônicos, além da amplificação da distorção quando os equipamentos são por ela alimentados. / Esta dissertação objetiva analisar a emissão, a propagação e a interação entre equipamentos envolvendo componentes harmônicas que possuem frequência na faixa entre 2 kHz e 150 kHz, denominadas supraharmônicos. A literatura especializada já reportou a emissão de supraharmônicos por equipamentos eletrônicos como lâmpadas fluorescentes, lâmpadas LED, inversores de frequência e nobreaks, além de impactos relacionados ao aquecimento de cabos e terminações, ruído acústico e interferência em sistemas PLC (Power Line Communication). No presente trabalho, foram realizadas campanhas de medição, em ambiente laboratorial, em inversores de frequência e um conjunto de lâmpadas LED. As medições se dividiram em dois grupos distintos: com os equipamentos conectados à rede elétrica e a uma fonte eletrônica trifásica, com o objetivo de verificar as ordens e os níveis, tanto das emissões provenientes dos equipamentos, quanto da distorção emitida pela própria fonte eletrônica, além da interação entre a fonte e os equipamentos alimentados. Foram empregadas a Transformada de Fourier e a Transformada Wavelet Packet para efetuar a análise e caracterização das distorções observadas. As medições mostraram uma contribuição significativa dos equipamentos observados e da fonte eletrônica para a emissão de supraharmônicos, além da amplificação da distorção quando os equipamentos são por ela alimentados.
85

Extração de características combinadas com árvore de decisão para detecção e classificação dos distúrbios de qualidade da energia elétrica / Features extraction combined with decision tree for detection and classification of disorders of power quality

Borges, Fábbio Anderson Silva 11 July 2013 (has links)
Este trabalho apresenta uma metodologia de detecção e classificação de distúrbios relacionados à qualidade da energia elétrica. A detecção é feita utilizando-se somente uma regra para inferir na presença ou não do distúrbio em uma janela analisada. Para a classificação é proposto um método baseado em árvore de decisão. A árvore recebe como entrada as características do sinal extraídas tanto no domínio do tempo como no domínio da frequência, sendo a última obtida pela Transformada de Fourier. Destaca-se que toda a metodologia de extração de características foi idealizada como tentativa de se reduzir ao máximo o esforço computacional das tarefas de detecção e classificação de distúrbios. Em suma, verifica-se que os resultados obtidos são satisfatórios para a proposta desta pesquisa. / This work presents a methodology for detection and classification of disturbance related to the electric power quality. The detection is performed using only one rule to infer in the presence or not of the disturbance in a window analyzed. For the classification is proposed a method based on decision tree. The tree receives as input features of the extracted signal both in time domain and in the frequency domain, being the last obtained by Fourier transform. It is emphasized that all the features extraction methodology was idealized as an attempt to reduce to the maximum the computational effort for the tasks of detection and classification of disturbances. In short, it is possible to verify that the results obtained are satisfactory for the purpose of this research.
86

Controle fuzzy para melhoria do perfil de tensão em sistemas de distribuição de energia elétrica / Fuzzy control to improve voltage profile in distribution system

Wesley Fernando Usida 28 February 2007 (has links)
Os objetivos deste trabalho compõem apresentar o andamento das pesquisas relacionadas à regulação de tensão em sistemas de distribuição de energia elétrica e propor um controle baseado em sistemas inteligentes para melhoria do perfil de tensão, permitindo que sejam atendidas as regulamentações mais exigentes do setor elétrico brasileiro. São considerados os aspectos sazonal, diário e não previsto do comportamento das cargas referentes à subestação de distribuição. Para isso, o trabalho propõe um relé regulador de tensão baseado em sistemas fuzzy que irá atuar diretamente no comutador de tap em transformadores de potência instalados em subestações de distribuição. Tal relé foi implementado por meio de um algoritmo computacional no Matlab. Os resultados foram obtidos por meio de simulações do real comportamento de carga indicando a viabilidade do sistema proposto. / The aim of this work is to present some research applied to voltage regulation in distribution systems and to propose a control system based on intelligent tools to improve the voltage profile of the system, considering the most demanding requirements of brazilian utilities. Periodical, daily and not foreseen aspects of the electrical loads in distribution system were considered. Therefore, the work proposes an automatic voltage regulator relay based on fuzzy systems, acting directly on load tap changing of transformers installed in a substation of the distribution system. This relay was implemented by computational algorithm in Matlab. The results were obtained by simulation of the real load behavior indicating the applicability of the proposed system.
87

Análise de requisitos técnicos para ilhamento intencional de geradores síncronos distribuídos / Analysis of technical requirements for intentional islanding of distributed synchronous generators

Rogério Lúcio Lima 09 August 2013 (has links)
Havendo qualquer distúrbio em um determinado sistema de distribuição de energia elétrica na presença de geradores distribuídos (GDs), é procedimento habitual exigido pelas concessionárias a desconexão destes na intenção de evitar a formação de um sistema ilhado eletricamente sustentado. Este procedimento tem como objetivo evitar maiores danos tanto ao sistema elétrico como um todo, principalmente ao próprio gerador distribuído, bem como às pessoas envolvidas na manutenção desse sistema. Entretanto, esse fato diminui consideravelmente as contribuições do conceito de geração distribuída à melhoria da qualidade dos serviços de fornecimento de energia elétrica por parte das concessionárias. Neste contexto, este trabalho possui como objetivo analisar os requisitos técnicos necessários para viabilizar a operação ilhada dos geradores distribuídos. Sabendo que a maioria das cargas presentes em um sistema de distribuição é dependente dos níveis de tensão e frequência da energia de suprimento, a análise e o monitoramento dessas grandezas antes e durante o ilhamento deverão ocorrer de forma que não se perca a estabilidade da rede ilhada. Para isto, devem ser avaliadas alterações nos métodos de operação e controle dos geradores distribuídos, de maneira a atender os requisitos técnicos necessários para manter a tensão e a frequência dentro dos parâmetros de qualidade de energia elétrica. Foram propostos quatro índices de desempenho para avaliar a qualidade da energia elétrica no sistema ilhado. Os resultados obtidos demonstram a necessidade de efetuar ações corretivas eficientes para manter o sistema elétrico ilhado operando dentro dos padrões aceitáveis de qualidade de energia elétrica. Foram investigadas soluções potenciais e viáveis para garantir a operação da ilha estável e com qualidade da energia elétrica. Além disso, observou-se que cargas dependentes da tensão podem influenciar significativamente a capacidade do GD em formar de ilhas estáveis. / If disturbances occur in a power distribution systems in the presence of distributed generators (DGs), a common practice required by utilities is to disconnect such generators, aiming at avoiding a self-sustained energized island. This procedure is required on order to prevent damage to the whole distribution system, mainly the DG, and to the utility maintenance personnel, as well. However, this requirement may decrease the possible contributions of the distributed generation concepts to the quality of the power supply. In this context, this work aims at analyzing the technical requirements related to make DGs islanded operation feasible. Since most of the loads are dependent on the supply voltage and frequency, the analysis and monitoring of such quantities before and after an islanding event should occur in such a way that the stability of the energized island is granted. To reach such a goal, changes in the DG control modes must be assessed, so that the technical requirements necessary to keep voltage and frequency within statutory limits are fulfilled. Four performance indices have been proposed to assess the power quality in the islanded system. The results have shown the need to perform efficient corrective actions to ensure reliable islanded operation. Moreover, it was observed that voltage-dependent loads may influence the DG capability to sustain stable islands.
88

Modelagem de lâmpadas de descarga: uma análise de desempenho considerando parâmetros de qualidade da energia / Discharge lamps modeling: a performance analysis considering power quality parameters

André Luiz Andreoli 08 April 2011 (has links)
Este trabalho apresenta pesquisa relativa à modelagem de lâmpadas de descarga. A metodologia desenvolvida fornece meios de se construir modelos baseados em ferramentas inteligentes, especificamente através de redes neurais artificiais, de forma a representar o dispositivo com características que descrevam seus aspectos operacionais, bem como o comportamento de tais dispositivos diante de eventos relacionados à qualidade da energia elétrica. Um modelo matemático do conjunto lâmpada-reator, caracterizado como carga não-linear foi implementado inicialmente através da ferramenta SIMULINK®, integrante do pacote de software MATLAB®, e os resultados de simulações obtidas com este modelo são apresentados e comparados com os dados de operação obtidos experimentalmente, servindo como base de modelo para a lâmpada de descarga estudada e ponto de partida para a modelagem baseada em ferramentas computacionais inteligentes. Como contribuição, foi proposta a arquitetura de um modelo baseado em um conjunto de redes neurais artificiais destinado a representar a operação do conjunto lâmpada de descarga e reator. Empregando a massa de dados obtida através de ensaios realizados em diversas condições operacionais, e com o auxílio do pacote de software MATLAB®, realizou-se o treinamento de duas redes neurais artificiais que em conjunto foram capazes de representar com elevado grau de fidelidade o comportamento de uma lâmpada de descarga, incluindo as respostas transitórias a eventos relacionados à qualidade da energia elétrica. Comparado com o modelo matemático, o modelo neural proposto demonstrou maior facilidade de aplicação e boa representação do dispositivo e exigiu esforço computacional consideravelmente menor para simulações envolvendo grandes períodos de tempo e elevado número de dispositivos. Além destas vantagens, a metodologia adotada possibilita a obtenção de modelos de outras famílias de lâmpadas de descarga a partir de dados experimentais apenas, sem necessidade de conhecimento dos dados físicos e construtivos do dispositivo. O elevado desempenho do modelo obtido permitiu a simulação de conjuntos de lâmpadas de descargas inseridos em um sistema de distribuição em tempos de simulação muito menores que os exigidos pelo modelo matemático, justificando sua aplicação nas representações desta família de cargas inseridas nos sistemas elétricos de potência. A representação do comportamento do dispositivo frente a distúrbios de qualidade da energia também se mostrou como uma ferramenta útil para estudos mais complexos no sistema de distribuição. / This work presents research related to the modeling of discharge lamps. This methodology made possible to build models based on intelligent tools, specifically artificial neural networks, to represent the device characteristics concerning operational aspects as well as the behavior of such devices facing power quality events. The mathematical model of a lamp-reactor, characterized as an non-linear load, was implemented using SIMULINK® toolbox, part of the software MATLAB®. The simulation results obtained from this model are compared with data obtained experimentally, serving as a base model for discharge lamps as well as a starting point for the modeling tools based on computational intelligence. As a contribution, an architecture of a model based on artificial neural networks designed to represent the operation of the discharge lamp and reactor was proposed. Employing the data obtained from tests performed under various operating conditions, and with the aid of the software MATLAB®, the training of two neural networks was performed. These networks were able to represent with high fidelity the behavior a discharge lamp, including the response to transient events related to power quality. Comparing to the mathematical model, the neural model demonstrated greater adaptation and good representation of the device and required a considerably lower computational effort for simulations involving large periods of time and a great number of devices. Besides these advantages, the methodology allows to obtain models from other families of discharge lamps from experimental data only, without the knowledge of the physical data of the device. The high performance of the neural model allowed the simulation of a group of discharge lamps in a distribution system with simulation time much smaller than those required by the mathematical model, justifying its application in electric power systems. The representation of such a device facing power quality disturbances also proved to be a useful tool for more complex studies in a distribution system.
89

Uma análise comparativa entre a simulação do modelo clássico de capacitores de potência e capacitores de potência reais testados em um ambiente laboratorial controlado / An analysis by comparing the classical power capacitors model simulated with the real power capacitors testes in a controlled laboratory environment

Alexandre Moriel da Silva 01 July 2013 (has links)
Esta pesquisa tem como principal objetivo apresentar uma análise do comportamento dos elementos passivos mais utilizados para compensação reativa e na composição dos filtros passivos sintonizados: os capacitores de potência. Tal análise foi focada na comparação de resultados obtidos via simulação computacional com os resultados oriundos de ensaios laboratoriais em ambiente controlado, servindo de base para estabelecer os limites de validade do modelo computacional hoje implementado em softwares comerciais de simulação de fluxo de carga e fluxo de harmônicos de uso bastante difundido no ambiente industrial. Os resultados alcançados demonstram que o modelo clássico de capacitores apresenta uma excelente precisão quando operando em condições ideais. Porém, quando operando na presença de situações adversas às ideais, o modelo demonstrou possuir limitações que serão devidamente reportadas neste documento. / This research has as aim to present a behaviors analysis of the electrical power capacitors which are used for reactive compensation and in the tuned harmonic passive filters. Such analysis was focused on the results comparison obtained via computer simulation with the results obtained in laboratory tests done in a controlled environment, providing the basis to establish the validity limits of the computational model implemented in today\'s commercial load flow and harmonic flow software simulation widespread use in industrial environments. Results show that the classical model capacitor has excellent accuracy when operating under ideal conditions. However, when operating in presence of adverse situations the classical model has demonstrated limitations that will be duly and reported in this work.
90

Metodologia de análise de variações de tensão causadas pela proteção anti-ilhamento de geradores síncronos distribuídos / Methodology for analysis of voltage variations caused by anti-island protection of distributed synchronous generators

Klaus Vieira do Nascimento 17 June 2013 (has links)
Nos últimos anos, fatores como a reestruturação do setor de energia elétrica, a necessidade de aproveitamento de diferentes fontes primárias de energia, dificuldades na construção de grandes unidades geradoras e linhas de transmissão causadas por normas de proteção ambiental têm provocado o aumento considerável do interesse por geração distribuída. O conceito de geração distribuída tornou-se muito interessante, entretanto, sua aplicação pode provocar problemas de qualidade de energia elétrica, caso sua influência não seja devidamente estudada. Neste contexto, este documento caracteriza as variações de tensão causadas pela atuação da proteção anti-ilhamento de geradores síncronos distribuídos. Este problema pode ser considerado uma nova abordagem sobre os impactos dos geradores distribuídos na qualidade da energia elétrica, visto que as causas das variações de tensão são tipicamente relacionadas às tomadas ou alívios de grandes blocos carga, partidas de motores de indução, curtos-circuitos, desligamentos de linhas etc. Para estudar o problema, inicialmente foi feito um estudo sobre normatização técnica da área com um apanhado dos guias de diversas concessionárias. Posteriormente, simulações computacionais utilizando o programa SimPowerSystems e um sistema teste foram utilizados para que análises estáticas e dinâmicas do problema fossem feitas no intuito de investigar a natureza das variações de tensão e os fatores que influenciam suas magnitudes e durações. Índices para avaliar as variações de tensão foram criados, e um método para obtenção dos mesmos foi proposto. Tal método utiliza apenas ferramentas de análise estática (fluxo de carga) para a obtenção dos índices, evitando o uso de ferramentas dinâmicas (domínio do tempo) reduzindo o custo computacional e financeiro para análise do problema. Em seguida, o mesmo foi aplicado a um sistema que simula uma rede de distribuição real propondo-se a inserção de bancos de capacitores como medida mitigatória para o problema estudado neste trabalho. / In recent years, factors such as the restructuring of the electricity sector, the necessity to use different primary energy sources as a way to diversify sources of energy, barriers in the construction of large generating units and transmission lines caused by environmental protection standards, as well as technological advances in the generation of electricity, have caused a considerable increase in the interest for distributed generation. The concept of distributed generation has become very interesting; however, its application can result in poor power quality, if its influence is not well studied. In this context, this document characterizes voltage variations caused by the action of anti-islanding protection of distributed synchronous generators. This problem can be considered a new approach on the impact of distributed generators in power quality, since the cause of voltage variations are typically related load switching, induction motors start-up, short circuits, lines disconnection, etc. To investigate the problem, initially a study was carried out on technical standardization in the area with an overview of various utilities guides. Later, computer simulations using the SimPowerSystems software and a test system were employed for static and dynamic analysis of the problem, aiming at investigating the nature of voltage variations and the main factors that influence their magnitudes and durations. Indices to assess the voltage variations were created, and a method for obtaining them was proposed. This method uses only static approach tools (power flow calculations) to obtain the indices, avoiding the use of dynamic tools (time-domain simulations) and reducing computational and financial costs to analyses the problem. The proposed method was applied to a larger system and the insertion of capacitors bank was proposed as mitigating solution for the problem studied in this work.

Page generated in 0.0797 seconds