• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização do conteúdo harmônico em ambientes residenciais: estudo de caso / Characterization of harmonic content in residential environments: case study.

Carvalho, Flavio Gomes de 26 February 2015 (has links)
Submitted by Maria Suzana Diniz (msuzanad@hotmail.com) on 2015-11-06T13:34:11Z No. of bitstreams: 1 arquivototal.pdf: 8252204 bytes, checksum: ee6c84ddd82f31470862718d3b1b3abc (MD5) / Made available in DSpace on 2015-11-06T13:34:11Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 8252204 bytes, checksum: ee6c84ddd82f31470862718d3b1b3abc (MD5) Previous issue date: 2015-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work a characterization of harmonic content in residential electrical systems through a set of measurements over various periods of time is performed. For each reported case it was a statement of charges that make up the installation and an individual analysis of each of them as a way to assess their influence on the harmonic behavior of the installation as a whole. / Neste trabalho é realizada uma caracterização do conteúdo harmônico em instalações elétricas residenciais por meio de um conjunto de medições realizadas por diversos períodos de tempo. Para cada caso avaliado fez-se um levantamento das cargas que compõem a instalação e uma análise individual de cada uma delas como forma de avaliar sua influência no comportamento harmônico da instalação como um todo.
2

Introducing a new measure of energy transition: Green quality of energy mix and its impact on CO2 emissions

Lau, C.K., Gozgor, Giray, Mahalik, M.K., Patel, G., Li, Jing 30 April 2023 (has links)
Yes / This paper introduces a novel measure of the energy transition, i.e., the green quality of energy mix (GREENQ) across the Organisation for Economic Co-operation and Development (OECD) countries. Then, the paper examines the impact of the GREENQ on CO2 emissions in the panel dataset of 36 OECD countries from 1970 to 2021. The explanatory variables include per capita income, institutional quality and technology. Long-run panel data estimations indicate that per capita income, institutional quality and technology increase CO2 emissions. The novel evidence is that the GREENQ is negatively related to the level of CO2 emissions. These findings are robust to employ different panel data estimation techniques. Potential policy implications are also discussed. / The project was funded by the “Foreign Cultural and Educational Experts Project of the Ministry of Science and Technology of China” (Project Number: DL2022180001L).
3

Análise experimental da qualidade da energia de uma microrrede fotovoltaica com back-up

Becker, Luís Rodrigo 27 March 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-07-10T14:32:15Z No. of bitstreams: 1 Luís Rodrigo Becker_.pdf: 4479543 bytes, checksum: 3a9259e64d112cb88c2414eb122552e9 (MD5) / Made available in DSpace on 2017-07-10T14:32:15Z (GMT). No. of bitstreams: 1 Luís Rodrigo Becker_.pdf: 4479543 bytes, checksum: 3a9259e64d112cb88c2414eb122552e9 (MD5) Previous issue date: 2017-03-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares / Este trabalho apresenta uma análise experimental de uma microrrede fotovoltaica formada por dois subsistemas, um isolado com estocagem e outro conectado à rede. Foi verificado o seu comportamento, sua capacidade no fornecimento de energia para uma carga isolada e rede da concessionária, monitorado a qualidade da energia elétrica entregue à diferentes cargas e rede da concessionária e também quantificado os índices de performance do sistema conectado. O subsistema conectado à rede (SFCR) é formado por um painel de 1080 Wp de silício multicristalino e um inversor c.c./c.a. de 1200 W. O subsistema isolado de back-up (SFI-b) é formado por um painel de 600 Wp de silício monocristalino, controlador de carga, banco de estocagem com baterias chumbo-ácido 24 V / 210 Ah e um inversor off-grid c.c./c.a. de 1000 W. O comportamento e a capacidade do sistema são monitorados durante o atendimento de uma carga, representada por um refrigerador. A qualidade da energia é analisada através de medições de energia ativa, reativa e aparente, fator de potência e geração de correntes harmônicas pelos inversores. O SFI-b é monitorado atendendo diferentes tipos e regimes de cargas. Já o SFCR é monitorado em dias de céu claro, parcialmente encobertos e encobertos. Os índices de performance são calculados em dias de céu claro e parcialmente encoberto ao longo dos seis primeiros meses de 2016. Os resultados demonstram que o SFI-b é capaz de atender a carga de forma confiável, comutando-a automaticamente para a concessionária quando o banco de baterias atinge uma profundidade de descarga pré-definida, enquanto o SFCR injeta a energia produzida na rede da concessionária. Os indicadores de qualidade da energia do inversor do SFI-b mostraram-se adequados, permanecendo dentro dos limites citados na legislação e análogos aos apresentados pela rede da distribuidora local. Já o inversor do SFCR apresentou indicadores de qualidade de energia satisfatórios, também na maior parte do tempo dentro dos limites citados na legislação, exceto nos dias encobertos e períodos de baixa irradiância, constatando-se significativa geração de energia reativa e distorções harmônicas de corrente. Considerando a média entre dias de céu claro e parcialmente encoberto, a eficiência média global do SFCR é de 9,9% e a energia média diária entregue à rede é de 4,7 kWh. Foi verificado que a qualidade da energia produzida pelo SFI-b praticamente independe da irradiância, já o SFCR depende diretamente da irradiância e do nível de carregamento do inversor, na geração de uma energia de qualidade. / This work presents an experimental analysis of a photovoltaic micro-grid formed by two subsystems, one off-grid with storage and another grid-connected. It is intended to verify its operation, its capacity to supply power to an isolated charge and electric utility grid, to monitor the quality of the electric power delivered to different charges and the electric grid power, and also to quantify the performance indexes of the connected system. The grid-connected subsystem (SFCR) consists of a panel of 1080 Wp of multicrystalline silicon and a DC/AC. inverter of 1200 W. The off-grid subsystem of back-up (SFI-b) consists of a 600 Wp monocrystalline silicon panel, charge controller, lead-acid battery storage bench 24 V / 210 Ah, and a DC/AC inverter of 1000 W. The operation and capacity of the system are monitored during the supply of a charge, represented by a refrigerator. The quality of the energy is analyzed through measurements of active, reactive and apparent energy, power factor and generation of harmonic currents by the inverters. SFI-b is monitored for different types and charges regimes, and SFCR is monitored on clear sky, partially and totally cloudy days. Performance indexes are calculated on clear sky and partly cloudy days over the first six months of 2016. The results demonstrate that the SFI-b is capable of servicing the charge reliably, switching it automatically to the utility grid when the batteries bank reaches a predetermined discharge depth, while the SFCR injects the power produced in power line grid. The energy quality indicators of the SFI-b inverter were adequate, staying inside the limits mentioned in the legislation, and analogous to those presented by the power line grid of the local distributor. The SFCR inverter presented satisfactory energy quality indicators, also in most of the time inside the limits mentioned in the legislation, except for the cloudy days and periods of low irradiance, showing significant reactive energy generation and current harmonic distortions. Considering the average between clear and partially cloudy days, the global average efficiency of SFCR is 9,9%, and the average daily energy injected on the grid is 4,7 kWh. It was verified that the quality of the energy produced by the SFI-b practically independent of the irradiance, but the SFCR depends directly on the irradiance and the load level of the inverter, in the quality energy generation.
4

Comparação técnico-econômica entre equipamentos mitigadores de harmônicos e compensadores de energia reativa

Lemes, Marcelo Inácio 10 December 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Soothing Equipment of harmonics and compensating reactive power have been widely discussed and applied successfully in recent years in the most varied industrial and commercial installations, encouraged by eliminating the fine for low power factor and by problems arising out of the significant increase in nonlinear loads connected to these electrical systems. Currently, various types of equipment that do the dual function of reducing harmonic content and power factor correction are applied using simulation techniques and well-known studies (through programmes computational load flow and flow harmonics) to ensure the most appropriate field response. In this sense, the proposed work is to show a technical-economical comparison between the equipment most frequently used as a solution of power factor and problems with harmonics, being them: Bank capacitors, passive harmonic filter detuned, passive harmonic filter tuned active harmonic filter, and harmonic hybrid filter. Evaluates the performance of each of these equipment mentioned above, where the following technical aspects will be assessed: voltage, current effective, total harmonic distortion of voltage (DTT), total harmonic distortion of current (DTI), active power, reactive, apparent, harmonic distortion and power factor. Simulations with the application of all types of equipment cited, power factor correction and filtering of harmonics, provide results with their respective implementation costs. Finally, the results obtained will be presented by monitoring in the field of the main electrical magnitudes in analysis, the solution adopted in the light of better cost x benefit and the performance of equipment installed for the desired by the company consumer goals. / Equipamentos mitigadores de harmônicos e compensadores de energia reativa têm sido bastante discutidos e aplicados nos últimos anos com sucesso nas mais variadas instalações comerciais e industriais, fomentados pela eliminação da tarifação por baixo fator de potência e por problemas advindos do aumento significativo de cargas não lineares conectadas a estes sistemas elétricos. Atualmente, diversos tipos de equipamentos que fazem à dupla função de redução do conteúdo harmônico e correção do fator de potência são aplicados, utilizando técnicas de simulação e estudos bem conhecidos (através de programas computacionais de fluxo de carga e fluxo harmônicos) visando garantir a resposta em campo mais adequada. Neste sentido, o trabalho proposto tem por objetivo mostrar uma comparação técnico-econômica entre os equipamentos mais utilizados como solução do fator de potência e de problemas com harmônicos, sendo eles: banco de capacitores, filtro harmônico passivo dessintonizado, filtro harmônico passivo sintonizado, filtro harmônico ativo e filtro harmônico híbrido. Será avaliado o desempenho destes equipamentos através dos seguintes aspectos técnicos: tensão eficaz, corrente eficaz, distorção harmônica total de tensão (DTT), distorção harmônica total de corrente (DTI), potência ativa, reativa, aparente, distorção harmônica e fator de potência. As simulações com a aplicação de todos os tipos de equipamentos citados, de correção do fator de potência e filtragem de harmônicos, proporcionarão resultados com seus respectivos custos de aplicação. Finalmente, serão apresentados os resultados obtidos através do monitoramento em campo das principais grandezas elétricas em análise, da solução adotada em função de uma melhor relação custo x benefício, bem como do desempenho dos equipamentos instalados, para os objetivos desejados pela empresa consumidora. / Mestre em Ciências
5

ANÁLISE PROBABILÍSTICA DE VARIAÇÕES DE TENSÃO DE CURTA DURAÇÃO EM REDES DE DISTRIBUIÇÃO / PROBABILIST ANALYSIS OF SHORT VARIATIONS TENSION DURATION IN DISTRIBUTION NETS

Lope, Miriam Dora Chávez 14 March 2005 (has links)
Made available in DSpace on 2016-08-17T14:52:57Z (GMT). No. of bitstreams: 1 Miriam Dora Chavez Lope.pdf: 1604085 bytes, checksum: 7eec68bb32ad68dca944d6146d4e5c5f (MD5) Previous issue date: 2005-03-14 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / In the whole world, the restructuring of the electrical sector promoted by the deregulation of the electric utilities has brought economical benefits for the society; furthermore there has been an increase of the pertinent interest in the subject of power quality. The competitive environment created by the deregulation forces the electric companies of generation and transmission to redefine their objectives in order to reduce their operation costs and to maximize their profits to guarantee their survival. Some of the measures adopted to reach these objectives, such as the postponement of the maintenance and investments for the expansion in the electric network, have as direct consequence the deterioration on the levels of reliability and quality of the supply. In distribution systems, this situation is more critical due to the monopolist nature of the electrical utilities. In other words, the consumers are subjected to the lucrative interests of these companies and, for that reasons, in several countries, the regulatory entities have been establishing goals for the reliability and quality of the supply aiming to punish the distribution utilities that violate these goals. In this new environment the interest of the electric utilities, consumers and regulatory entities for the quality of energy have been increasing due to the economical impact experienced by them. One of the problems of the quality of energy are the voltage sags effects, which has increased in recent years due to the crescent use of new equipments, which are more sensitive to voltage variations. The aim of this work is to develop a probabilistic methodology to analyse voltage sags in distribution networks. With the proposed methodology, power quality índices associated with voltage sags can be estimated in distribution systems, considering the system s topology and failure data. Due to the stochastic nature of the frequency and duration of fault, the proposed methodology is based on probabilistic models that permit to represent the system´s operation under faults. The proposed methodology is based on the combination of the Monte Carlo Method with the Admittance Summation Method. The Monte Carlo Method with sequential simulation is used to sample the failure scenarios and the Admittance Summation Method to evaluate fault currents. These fault currents are evaluated using a phase coordinate model of the distribution system. This model has been used due to the distribution networks unbalance caused by loads and untransposed overhead lines. Furthermore, voltage sags duration has been estimated using the current×time curves of the protection devices (fuses, breakers, reclosers). The proposed methodology has been tested in a feeder belonging to the Maranhão Electric Utility(CEMAR) and the results indicate that the proposed methodology is a good tool for studies of sags in distribution systems because it permits the evaluation of the system s performance against voltage sags, also estimating the compatibility between the system and the customer equipments. The results are shown through probability distributions of the SARFI%V, SARFICBEMA and SARFIITIC índices; cumulative and individual probability distributions, scattering diagrams and coordination charts of the voltage sags. / No mundo todo, a reestruturação do setor de energia promovida pela desregulamentação das empresas elétricas trouxe benefícios econômicos para a sociedade, resultando no aumento do interesse pertinente a questão da qualidade de energia. O ambiente competitivo criado pela desregulamentação obriga às empresas elétricas de geração e transmissão a redefinirem seus objetivos a fim de reduzir seus custos operacionais e maximizar seus lucros para garantir sua sobrevivência. Algumas das medidas adotadas para conseguir estes objetivos, tais como o adiamento da manutenção e investimentos de expansão na rede elétrica têm como conseqüência direta a deterioração dos níveis de qualidade e confiabilidade do fornecimento de energia. Em sistemas de distribuição esta situação é mais crítica devido à natureza monopolista das redes de distribuição. Os consumidores estão sujeitos aos interesses lucrativos destas empresas e, por causa disto, geralmente os órgãos reguladores estabelecem metas de confiabilidade e qualidade do fornecimento de energia elétrica a fim de evitar a deterioração da qualidade de fornecimento de energia e penalizar as empresas que violarem estas metas. Um dos problemas da qualidade de energia que basicamente preocupa são as variações de tensão de curta duração, cujos efeitos aumentaram em anos recentes devido ao crescente uso de equipamentos mais sensíveis à variações de tensão. Este trabalho tem como objetivo desenvolver uma metodologia probabilística para analisar as variações de tensão de curta duração em redes de distribuição. Com a metodologia proposta pode-se estimar índices de qualidade de energia associados as variações de tensão de curta duração em sistemas de distribuição, considerando-se a topologia e dados de falha do sistema. Devido à natureza estocástica da freqüência e duração das faltas, sendo o curto circuito a principal causa das variações de tensão de curta duração, a metodologia proposta se baseia em modelos probabilísticos que permitem representar a operação do sistema frente às faltas. A metodologia proposta se baseia na combinação do Método de Monte Carlo com o Método de Soma de Admitâncias. O Método de Monte Carlo com simulação seqüencial é usado para a amostra de cenários de faltas e o Método de Soma de Admitância para estimar as correntes de faltas. Estas correntes de faltas são estimadas usando-se o modelo de coordenadas de fase do sistema de distribuição. Este modelo é usado devido ao desequilíbrio das redes de distribuição causado pelas cargas e pelas linhas aéreas não transpostas. Além disso, a duração das variações de tensão de curta duração é estimada usando-se as curvas de tempo×corrente dos dispositivos de proteção (fusíveis, disjuntores, religadores). Para comprovar a aplicação prática, a metodologia foi testada em um alimentador da Companhia Energética do Maranhão (CEMAR). Os resultados são apresentados como: distribuições de probabilidade dos índices SARFI%V, SARFICBEMA e SARFIITIC; distribuições de probabilidade individual-cumulativa, diagramas de dispersão e cartas de coordenação das variações de tensão de curta duração. A metodologia proposta é uma ferramenta útil tanto para as empresas elétricas como para consumidores, porque permite avaliar o desempenho do sistema frente às variações de tensão de curta duração e estima a compatibilidade entre o sistema e os equipamentos do consumidor.

Page generated in 0.0907 seconds