• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Respiratory Motion Correction in PET Imaging: Comparative Analysis of External Device and Data-driven Gating Approaches / Respiratorisk rörelsekorrigering inom PET-avbildning: En jämförande analys av extern enhetsbaserad och datadriven gating-strategi

Lindström Söraas, Nina January 2023 (has links)
Positron Emission Tomography (PET) is pivotal in medical imaging but is prone to artifactsfrom physiological movements, notably respiration. These motion artifacts both degradeimage quality and compromise precise attenuation correction. To counteract this, gatingstrategies partition PET data in synchronization with respiratory cycles, ensuring each gatenearly represents a static phase. Additionally, a 3D deep learning image registration modelcan be used for inter-gate motion correction, maximizing the use of the full acquired data. Thisstudy aimed to implement and evaluate two gating strategies: an external device-based approachand a data-driven centroid-of-distribution (COD) trace algorithm, and assess their impact on theperformance of the registration model. Analysis of clinical data from four subjects indicated thatthe external device approach outperformed its data-driven counterpart, which faced challengesin real-patient settings. Post motion compensation, both methods achieved results comparableto state-of-the-art reconstructions, suggesting the deep learning model addressed some data-driven method limitations. However, the motion corrected outputs did not exhibit significantimprovements in image quality over state-of-the-art standards. / Positronemissionstomografi (PET) är fundamentalt inom medicinsk avbildning men påverkasav artefakter orsakade av fysiologiska rörelser, framför allt andning. Dessa artefakter påverkarbildkvaliteten negativt och försvårar korrekt attenueringskorrigering. För att motverka dettakan tekniker för rörelsekorrigering tillämpas. Dessa innefattar gating-tekniker där PET-dataförst synkroniseras med andningscykeln för att därefter segmenterateras i olika så kalladegater som representerar en specifick respiratorisk fas. Vidare kan en 3D djupinlärningsmodellanvändas för att korrigera för rörelserna mellan gaterna, vilket optimerar användningen av allinsamlad data. Denna studie implementerade och undersökte två gating-tekniker: en externenhetsbaserad metod och en datadriven ”centroid-of-distribution (COD)” spår-algoritm, samtanalyserade hur dessa tekniker påverkar prestandan av bildregistreringsmodellen. Utifrånanalysen av kliniska data från fyra patienter visade sig metoden med den externa enhetenvara överlägsen den datadrivna metoden, som hade svårigheter i verkliga patient-situationer.Trots detta visade bildregistreringsmodellen potential att delvis kompensera för den datadrivnametodens begränsningar, då resultatet från båda strategeierna var jämförbara med befintligaklinisk bildrekonstruktion. Dock kunde ingen markant förbättring i bildkvalitet urskiljas av derörelsekorrigerade bilderna jämfört med nuvarande toppstandard.
2

Extracting Cardiac and Respiratory Self-Gating Signals from Magnetic Resonance Imaging Data / Extrahering av Self-Gating signaler för hjärt- och respirationsrytm från magnetisk resonanstomografi-data

Hellström Karlsson, Rebecca, Peterson, Tobias January 2015 (has links)
Motion artefacts due to cardiac and respiratory motion present a daily challenge in cardiac Magnetic Resonance Imaging (MRI), and many different motion correction procedures are used in clinical routine imaging. To reduce motion artefacts further, patients are required to hold their breath during parts of the data acquisition, which is physically straining – especially when done repetitively. Self-Gating (SG) is a method that extracts cardiac and respiratory motion information from the MRI data in the form of signals, called SG signals, and uses them to divide the data into the specific cardiac and respiratory phases it was acquired from. This method both avoids motion artefacts and allow for free-breathing acquisition. This project’s goal was to find a method for extracting cardiac and respiratory SG signals from MRI data. The data was acquired with a golden angle radial acquisition method for 3-dimensional (3D) scans. Extraction of the raw signal was tested for both raw k-space data and high temporal resolution image series, where the images were reconstructed using a sliding window reconstruction. Filters were then applied to isolate the cardiac and respiratory information, to create separate cardiac and respiratory SG signals. Thereafter trigger points marking the beginning of the cardiac and respiratory cycles were generated. The trigger points were compared against ECG and respiratory trigger points provided by the MR scanner. The conclusion was that the SG signals based on k-space data was functional on the scans from the evaluated subjects and the most effective choice of the two options, but image based SG signals may prove to be functional after further studies. / Rörelseartefakter på grund av hjärt- och respirationsrörelser är idag vardagliga utmaningar inom magnetresonanstomografi (MR) av hjärtat, och många olika metoder används för att eliminera rörelseartefakterna. Patienterna behöver dessutom hålla andan under delar av dataupptagningen, vilket är fysiskt ansträngande – speciellt när det sker upprepade gånger. Self-Gating (SG) är en metod som extraherar information hjärt- och respirationsrytm från MR-datan i form av signaler, kallade SG signaler, och använder dem för att dela in datan i de specifika hjärt- respektive respirationsfaser som var när datan upptogs. Denna metod både undviker rörelseartefakter och tillåter fri andning under dataupptagningen. Målet med det här projektet var att hitta en metod för att extrahera SG signaler för hjärt- och respirationsrytm från MR-data. Datan samlades in med en golden angle radial-upptagning för 3- dimensionella (3D) scanningar. Extraheringen av den råa signalen testades på både rå k-space data och på bildserier av 3D-bilder med hög tidsupplösning, där bilderna var rekonstruerade med en sliding window rekonstruktion. Därefter applicerades filter för att isolera hjärt- och respirationsinformationen, för att få separata SG signaler med endast hjärt- respektive respirationsrytmer. Till slut genererades triggerpunkter för att markera början av hjärt- respektive respirationscyklerna. Dessa jämfördes med triggerpunkter uppmätta med EKG och andningskudde i magnetkameran. Slutsatsen för projektet var att SG signalerna som baserades på k-space data var funktionell för de scanningar som testades och det mest effektiva alternativet, men SG signalerna som baserades på bilder kan visa sig fungera efter mer studier.

Page generated in 0.0916 seconds