• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de glucuronídeos em urina humana com injeção direta de amostras por cromatografia líquida acoplada à espectrometria de massa / Glucuronide analysis with direct injection of human urine by liquid chromatography mass spectrometry

Castral, Thaís Corrêa 17 December 2013 (has links)
Made available in DSpace on 2016-06-02T20:34:53Z (GMT). No. of bitstreams: 1 6024.pdf: 16349859 bytes, checksum: 7382f8d4bf5a05fb4df9d51d782682b1 (MD5) Previous issue date: 2013-12-17 / Universidade Federal de Minas Gerais / This work describes the results obtained from studies carried out to quantify phenyl-β-D-glucuronide (FG) and nitrophenyl-β-D-glucuronide (NFG) in human urine by direct injection sample using LC-MS/MS system. The columns RAM-BSA SAX and RAM-BSA C8 were prepared and evaluated in relation to their exclusion capability of urine macromolecules and retention capability of FG by direct injection samples. Both columns presented good retention capability for glucuronide, however, the RAM-BSA SAX column was more efficient in exclusion since this column did not have any interferences eluting after the exclusion time. However, the RAM-BSA SAX column can not be used for FG quantification by LC-MS/MS because the chromatographic condition of this column presented high buffer concentration (40 mM ammonium formate), which resulted in total suppression of the FG signal. Therefore, the column RAM-BSA C8 was selected for the development of the methods. In this study we evaluated triple quadrupole (QqQ) and ion trap (IT) mass spectrometry for both selected glucuronides. It was not possible to obtain selectivity in the analytical conditions developed using UHPLC-QqQ. When we used the IT analyzer, we obtained selectivity in a multidimensional mode for the FG using the column RAM-BSA C8 in the first dimension and the column Ascentis Express F5 in the second dimension. For the NFG we achieved selectivity in a unidimensional mode. The figures of merit obtained with external standarization calibration curve with spiked pooled urines were accurate and precise. For FG, the LQ and LD were 1.0 μg/mL and 0.5 μg/mL, respectively, and to NFG, the LQ and LD were 4.0 μg/mL and 3.0 μg/mL. For the method application we adopted calibration by standard addition to minimize the individual differences between urine donors. To all six toxicological samples analyzed, just one exceeded the regulatory limits for urinary phenol. For NFG, there were no toxicological samples available, thus the method was applied in spiked samples in the laboratory. / Este trabalho descreve os resultados obtidos nos estudos feitos para quantificar fenil-β-D-glucuronídeo (FG) e nitrofenil-β-D-glucuronídeo (NFG), em urina humana por injeção direta de amostra, utilizando-se sistemas LC-MS/MS. Para injeção direta de amostras, as colunas RAM-BSA SAX e RAM-BSA C8 foram preparadas e avaliadas em relação à capacidade de exclusão das macromoléculas da urina e à capacidade de retenção do FG. Ambas as colunas apresentaram boa capacidade de retenção para o glucuronídeo, no entanto, quanto à exclusão, a coluna RAM-BSA SAX mostrou-se mais eficiente, visto que nesta coluna não houve eluição de interferentes, após o tempo de exclusão. Porém, a coluna RAM-BSA SAX não pode ser utilizada para a quantificação de FG por LCMS/ MS, pois as condições cromatográficas estabelecidas para esta coluna envolveram alta concentração de tampão (formiato de amônio 40 mM), o que acarretou na supressão total do sinal referente ao FG. Portanto, a coluna RAMBSA C8 foi selecionada para o desenvolvimento dos métodos. Neste trabalho avaliaram-se os analisadores do tipo triplo quadrupolo (QqQ) e ion trap (IT) para ambos os glucuronídeos estudados. Nas condições analíticas desenvolvidas utilizando-se UHPLC-QqQ, não foi possível se obter seletividade. Quando o IT foi utilizado como analisador, a seletividade foi obtida no modo multidimensional para o FG, utilizando-se a coluna RAM-BSA C8 na primeira dimensão e a coluna Ascentis Express F5 na segunda dimensão, e no modo simples para o NFG. As figuras de méritos obtidas por padronização externa, a partir de uma curva construída fortificando-se um pool de urinas, foram exatas e precisas, com LQ de 1,0 μg/mL e LD de 0,5 μg/mL, para FG, e LQ de 4,0 μg/mL e LD de 3,0 μg/mL, para o NFG. Para aplicação dos métodos, a calibração por adição de padrão foi adotada para contornar as diferenças individuais entre as urinas dos doadores. Das seis amostras toxicológicas analisadas, uma amostra ultrapassou o valor de referência da normalidade para fenol urinário. Para o NFG, na ausência de amostras toxicológicas, o método foi aplicado em amostras-padrão preparadas no laboratório.

Page generated in 0.0123 seconds