Mass Transfer of Ionic Species in Direct and Reverse Osmosis Processes

Ghiu, Silvana Melania Stefania 31 October 2003 (has links)
This dissertation investigates the importance of diffusional and convective fluxes for salts in reverse osmosis (RO) and nanofiltration (NF) membranes. Moreover, the physical and thermodynamic factors controlling the salt permeability are analyzed. The study utilizes direct osmosis (DO) experiments and RO experiments, the later using both flat sheet and spiral wound membrane configurations. The salts considered are chlorides and acetates of alkali metals and alkaline earth metals. The equation governing the salt transport in DO experiments is derived and a phenomenon inverse to concentration polarization in RO is observed. The salt permeability in DO is equal to the salt permeability calculated for the valid cases of the used RO models. DO is suggested as an alternative method in characterizing the salt transport in membranes. The method can be more advantageous than RO due to the lower costs and simplicity of the apparatus. The models used to calculate the salt transport parameters in RO experiments are Spiegler-Kedem model, which considers both diffusion and convection of salt, and Kimura-Sourirajan model, which considers only diffusion of salt. It is found that diffusion is the dominant mechanism of transport in both RO and NF membranes. The percentage of the salt diffusional flux of the total flux is highest for seawater membranes and it is approximately equal for brackish water and nanofiltration membranes. The salt diffusive flux contribute more to the total flux for the 1:2 salts than for 1:1 salts. The two RO models are found equivalent in determining the salt permeability for only the seawater membranes. The Kimura-Sourirajan model overestimates the salt permeability coefficient for salts with rejection coefficient lower than 86%. The permeation rates for studied salts follow the lyotropic series regardless the membrane type (RO or NF), the membrane configuration (flat sheet or spiral wound), the process (DO or RO), or the models used for the calculations. This order of salt permeability is explained by the hydration of the cations, which is quantified by the enthalpy and entropy of hydration. The relative free energy theory can also be used to predict the salt permeability in a membrane based on preliminary data.
2

Avaliação do pré-tratamento de uma corrente de purga para um sistema de filtração com membranas de osmose inversa descartadas

Frick, Julia Menegotto January 2013 (has links)
A Osmose Inversa (OI) é amplamente utilizada nos processos de desmineralização, onde são utilizados módulos espirais que após 3 a 5 anos de uso são descartados devido à queda de seu desempenho. Estes módulos ainda podem ser reaproveitados em tratamentos que não exijam um efluente final com qualidade tão elevada, como por exemplo, em correntes de reuso. Um efluente com potencial para ser reutilizado é a purga, a qual é drenada da bacia da torre de resfriamento com a finalidade de reduzir a concentração de sais e outras impurezas da água de recirculação. Estes processos industriais utilizam grandes quantidades de água, sendo de grande importância estudos que visem o seu reaproveitamento. Uma alternativa seria o tratamento desta corrente utilizando as membranas de OI descartadas, porém um fator limitante é a qualidade do efluente que irá alimentar os módulos de OI descartados, devido à pequena espessura dos canais de alimentação. A proposta deste trabalho foi ajustar o pré-tratamento para um sistema de filtração com membranas de OI descartadas com o objetivo de tratar e reutilizar a corrente de purga de uma torre de resfriamento, como água de reposição. Foram avaliados como pré-tratamentos processos de coagulação/floculação, filtração com filtro de areia,sorção com carvão ativado comercial e combinações destes. A avaliação da eficiência dos tratamentos foi realizada através de análises de pH, condutividade elétrica, turbidez, dureza total, DQO, sílica e SDI. Após cada pré-tratamento, o efluente tratado foi alimentado no sistema de OI, avaliando-se o fluxo de permeado, permeabilidade hidráulica, retenção salina e a propensão ao fouling, para, então, determinar a eficiência do tratamento proposto. O permeado foi analisado e os parâmetros foram comparados com a água de reposição utilizada na torre de resfriamento. Verificou-se que o melhor tratamento obtido foi utilizando a coagulação/floculação seguida do filtro de areia, apresentando SDI5 5,5 e turbidez de 0,3 NTU; o processo de sorção com carvão ativado não demonstrou bons resultados para as condições testadas. Através das análises das membranas utilizadas para as medidas de SDI e dos valores dos contaminantes presentes após os pré-tratamentos, pôde-se perceber uma diminuição de incrustações referentes aos teores de sílica e dureza, principais causadores de fouling, indicando uma melhora na qualidade da corrente de purga pré-tratada, que apresentou características adequadas para alimentação do sistema de OI. Ainda, as membranas de OI apresentaram uma retenção salina em torno de 97% e as análises dos permeados obtidos indicaram valores de contaminantes inferiores aos da água de reposição da torre, demonstrando a possibilidade de reutilização. / Reverse Osmosis (RO) is widely used in demineralization processes, where spiral wound modules are used, which after 3-5 years are discarded to lose their performance. However, these modules can be reused for treatments that do not require final effluent with so high quality. The blowdown is drained from the basin of the cooling tower in order to reduce the concentration of salts and other impurities from recirculating water. These industrial processes use large quantities of water, so it’s important to study reuse possibilities. An alternative would be treating this stream using RO discarded membranes, but some limiting factors are the quality of the feed water and the thin feed channels. Thus, the aim of the study is to set a pretreatment to a RO system that uses discarded membranes from the demineralization process to treat the blowdown stream of a cooling tower, with will reuse as make-up water. Steps of coagulation and flocculation, sand filter filtration, sorption with activated carbon and combinations of these were proposed as pre-treatments. Analysis of pH, conductivity, turbidity, total hardness, COD, silica and SDI were used to evaluate the efficiency of the pretreatments. After each proposed pre-treatment, the treated effluent was tested in RO system and the permeate flow, salt retention and hydraulic permeability were evaluated to identify the presence of fouling and the membranes performance. Also the permeate analysis were compared with the makeup water used in the cooling tower. The sand filter as only step treatment is not effective for good treatment of the stream, obtaining the best result when coupled with coagulation/flocculation process. The GAC had not shown good results for the tested conditions. RO discarded membranes presented high salt retention, about 97% and analysis of the permeates indicate the reuse possibility. Through MEV and EDS analysis of SDI membranes, we could notice a decrease of scale related to silica and hardness, which are the main cause of fouling, indicating an improvement of the quality of the treated stream, which presents suitable characteristics for feed RO systems with discarded modules.
3

Avaliação do pré-tratamento de uma corrente de purga para um sistema de filtração com membranas de osmose inversa descartadas

Frick, Julia Menegotto January 2013 (has links)
A Osmose Inversa (OI) é amplamente utilizada nos processos de desmineralização, onde são utilizados módulos espirais que após 3 a 5 anos de uso são descartados devido à queda de seu desempenho. Estes módulos ainda podem ser reaproveitados em tratamentos que não exijam um efluente final com qualidade tão elevada, como por exemplo, em correntes de reuso. Um efluente com potencial para ser reutilizado é a purga, a qual é drenada da bacia da torre de resfriamento com a finalidade de reduzir a concentração de sais e outras impurezas da água de recirculação. Estes processos industriais utilizam grandes quantidades de água, sendo de grande importância estudos que visem o seu reaproveitamento. Uma alternativa seria o tratamento desta corrente utilizando as membranas de OI descartadas, porém um fator limitante é a qualidade do efluente que irá alimentar os módulos de OI descartados, devido à pequena espessura dos canais de alimentação. A proposta deste trabalho foi ajustar o pré-tratamento para um sistema de filtração com membranas de OI descartadas com o objetivo de tratar e reutilizar a corrente de purga de uma torre de resfriamento, como água de reposição. Foram avaliados como pré-tratamentos processos de coagulação/floculação, filtração com filtro de areia,sorção com carvão ativado comercial e combinações destes. A avaliação da eficiência dos tratamentos foi realizada através de análises de pH, condutividade elétrica, turbidez, dureza total, DQO, sílica e SDI. Após cada pré-tratamento, o efluente tratado foi alimentado no sistema de OI, avaliando-se o fluxo de permeado, permeabilidade hidráulica, retenção salina e a propensão ao fouling, para, então, determinar a eficiência do tratamento proposto. O permeado foi analisado e os parâmetros foram comparados com a água de reposição utilizada na torre de resfriamento. Verificou-se que o melhor tratamento obtido foi utilizando a coagulação/floculação seguida do filtro de areia, apresentando SDI5 5,5 e turbidez de 0,3 NTU; o processo de sorção com carvão ativado não demonstrou bons resultados para as condições testadas. Através das análises das membranas utilizadas para as medidas de SDI e dos valores dos contaminantes presentes após os pré-tratamentos, pôde-se perceber uma diminuição de incrustações referentes aos teores de sílica e dureza, principais causadores de fouling, indicando uma melhora na qualidade da corrente de purga pré-tratada, que apresentou características adequadas para alimentação do sistema de OI. Ainda, as membranas de OI apresentaram uma retenção salina em torno de 97% e as análises dos permeados obtidos indicaram valores de contaminantes inferiores aos da água de reposição da torre, demonstrando a possibilidade de reutilização. / Reverse Osmosis (RO) is widely used in demineralization processes, where spiral wound modules are used, which after 3-5 years are discarded to lose their performance. However, these modules can be reused for treatments that do not require final effluent with so high quality. The blowdown is drained from the basin of the cooling tower in order to reduce the concentration of salts and other impurities from recirculating water. These industrial processes use large quantities of water, so it’s important to study reuse possibilities. An alternative would be treating this stream using RO discarded membranes, but some limiting factors are the quality of the feed water and the thin feed channels. Thus, the aim of the study is to set a pretreatment to a RO system that uses discarded membranes from the demineralization process to treat the blowdown stream of a cooling tower, with will reuse as make-up water. Steps of coagulation and flocculation, sand filter filtration, sorption with activated carbon and combinations of these were proposed as pre-treatments. Analysis of pH, conductivity, turbidity, total hardness, COD, silica and SDI were used to evaluate the efficiency of the pretreatments. After each proposed pre-treatment, the treated effluent was tested in RO system and the permeate flow, salt retention and hydraulic permeability were evaluated to identify the presence of fouling and the membranes performance. Also the permeate analysis were compared with the makeup water used in the cooling tower. The sand filter as only step treatment is not effective for good treatment of the stream, obtaining the best result when coupled with coagulation/flocculation process. The GAC had not shown good results for the tested conditions. RO discarded membranes presented high salt retention, about 97% and analysis of the permeates indicate the reuse possibility. Through MEV and EDS analysis of SDI membranes, we could notice a decrease of scale related to silica and hardness, which are the main cause of fouling, indicating an improvement of the quality of the treated stream, which presents suitable characteristics for feed RO systems with discarded modules.
4

Avaliação do pré-tratamento de uma corrente de purga para um sistema de filtração com membranas de osmose inversa descartadas

Frick, Julia Menegotto January 2013 (has links)
A Osmose Inversa (OI) é amplamente utilizada nos processos de desmineralização, onde são utilizados módulos espirais que após 3 a 5 anos de uso são descartados devido à queda de seu desempenho. Estes módulos ainda podem ser reaproveitados em tratamentos que não exijam um efluente final com qualidade tão elevada, como por exemplo, em correntes de reuso. Um efluente com potencial para ser reutilizado é a purga, a qual é drenada da bacia da torre de resfriamento com a finalidade de reduzir a concentração de sais e outras impurezas da água de recirculação. Estes processos industriais utilizam grandes quantidades de água, sendo de grande importância estudos que visem o seu reaproveitamento. Uma alternativa seria o tratamento desta corrente utilizando as membranas de OI descartadas, porém um fator limitante é a qualidade do efluente que irá alimentar os módulos de OI descartados, devido à pequena espessura dos canais de alimentação. A proposta deste trabalho foi ajustar o pré-tratamento para um sistema de filtração com membranas de OI descartadas com o objetivo de tratar e reutilizar a corrente de purga de uma torre de resfriamento, como água de reposição. Foram avaliados como pré-tratamentos processos de coagulação/floculação, filtração com filtro de areia,sorção com carvão ativado comercial e combinações destes. A avaliação da eficiência dos tratamentos foi realizada através de análises de pH, condutividade elétrica, turbidez, dureza total, DQO, sílica e SDI. Após cada pré-tratamento, o efluente tratado foi alimentado no sistema de OI, avaliando-se o fluxo de permeado, permeabilidade hidráulica, retenção salina e a propensão ao fouling, para, então, determinar a eficiência do tratamento proposto. O permeado foi analisado e os parâmetros foram comparados com a água de reposição utilizada na torre de resfriamento. Verificou-se que o melhor tratamento obtido foi utilizando a coagulação/floculação seguida do filtro de areia, apresentando SDI5 5,5 e turbidez de 0,3 NTU; o processo de sorção com carvão ativado não demonstrou bons resultados para as condições testadas. Através das análises das membranas utilizadas para as medidas de SDI e dos valores dos contaminantes presentes após os pré-tratamentos, pôde-se perceber uma diminuição de incrustações referentes aos teores de sílica e dureza, principais causadores de fouling, indicando uma melhora na qualidade da corrente de purga pré-tratada, que apresentou características adequadas para alimentação do sistema de OI. Ainda, as membranas de OI apresentaram uma retenção salina em torno de 97% e as análises dos permeados obtidos indicaram valores de contaminantes inferiores aos da água de reposição da torre, demonstrando a possibilidade de reutilização. / Reverse Osmosis (RO) is widely used in demineralization processes, where spiral wound modules are used, which after 3-5 years are discarded to lose their performance. However, these modules can be reused for treatments that do not require final effluent with so high quality. The blowdown is drained from the basin of the cooling tower in order to reduce the concentration of salts and other impurities from recirculating water. These industrial processes use large quantities of water, so it’s important to study reuse possibilities. An alternative would be treating this stream using RO discarded membranes, but some limiting factors are the quality of the feed water and the thin feed channels. Thus, the aim of the study is to set a pretreatment to a RO system that uses discarded membranes from the demineralization process to treat the blowdown stream of a cooling tower, with will reuse as make-up water. Steps of coagulation and flocculation, sand filter filtration, sorption with activated carbon and combinations of these were proposed as pre-treatments. Analysis of pH, conductivity, turbidity, total hardness, COD, silica and SDI were used to evaluate the efficiency of the pretreatments. After each proposed pre-treatment, the treated effluent was tested in RO system and the permeate flow, salt retention and hydraulic permeability were evaluated to identify the presence of fouling and the membranes performance. Also the permeate analysis were compared with the makeup water used in the cooling tower. The sand filter as only step treatment is not effective for good treatment of the stream, obtaining the best result when coupled with coagulation/flocculation process. The GAC had not shown good results for the tested conditions. RO discarded membranes presented high salt retention, about 97% and analysis of the permeates indicate the reuse possibility. Through MEV and EDS analysis of SDI membranes, we could notice a decrease of scale related to silica and hardness, which are the main cause of fouling, indicating an improvement of the quality of the treated stream, which presents suitable characteristics for feed RO systems with discarded modules.
5

Mass transfer of ionic species in direct and reverse osmosis processes [electronic resource] / by Silvana Melania Stefania Ghiu.

Ghiu, Silvana Melania Stefania. January 2003 (has links)
Includes vita. / Title from PDF of title page. / Document formatted into pages; contains 187 pages. / Thesis (Ph.D.)--University of South Florida, 2003. / Includes bibliographical references. / Text (Electronic thesis) in PDF format. / ABSTRACT: This dissertation investigates the importance of diffusional and convective fluxes for salts in reverse osmosis (RO) and nanofiltration (NF) membranes. Moreover, the physical and thermodynamic factors controlling the salt permeability are analyzed. The study utilizes direct osmosis (DO) experiments and RO experiments, the later using both flat sheet and spiral wound membrane configurations. The salts considered are chlorides and acetates of alkali metals and alkaline earth metals. The equation governing the salt transport in DO experiments is derived and a phenomenon inverse to concentration polarization in RO is observed. The salt permeability in DO is equal to the salt permeability calculated for the valid cases of the used RO models. DO is suggested as an alternative method in characterizing the salt transport in membranes. The method can be more advantageous than RO due to the lower costs and simplicity of the apparatus. / ABSTRACT: The models used to calculate the salt transport parameters in RO experiments are Spiegler-Kedem model, which considers both diffusion and convection of salt, and Kimura-Sourirajan model, which considers only diffusion of salt. It is found that diffusion is the dominant mechanism of transport in both RO and NF membranes. The percentage of the salt diffusional flux of the total flux is highest for seawater membranes and it is approximately equal for brackish water and nanofiltration membranes. The salt diffusive flux contribute more to the total flux for the 1:2 salts than for 1:1 salts. The two RO models are found equivalent in determining the salt permeability for only the seawater membranes. The Kimura-Sourirajan model overestimates the salt permeability coefficient for salts with rejection coefficient lower than 86%. / ABSTRACT: The permeation rates for studied salts follow the lyotropic series regardless the membrane type (RO or NF), the membrane configuration (flat sheet or spiral wound), the process (DO or RO), or the models used for the calculations. This order of salt permeability is explained by the hydration of the cations, which is quantified by the enthalpy and entropy of hydration. The relative free energy theory can also be used to predict the salt permeability in a membrane based on preliminary data. / System requirements: World Wide Web browser and PDF reader. / Mode of access: World Wide Web.