• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 15
  • 2
  • 2
  • 1
  • Tagged with
  • 159
  • 159
  • 35
  • 34
  • 23
  • 22
  • 22
  • 21
  • 21
  • 20
  • 19
  • 19
  • 17
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Projeto, construção e caracterização de um dosímetro para radiação de nêutrons

SOUTO, EDUARDO de B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:56Z (GMT). No. of bitstreams: 0 / Com o objetivo de monitorar o crescente número de trabalhadores potencialmente expostos à radiação de nêutrons, foi projetado e desenvolvido um dosímetro individual para campos mistos nêutron-gama. O dosímetro proposto foi caracterizado para o espectro de energia de uma fonte de Amerício-Berílio e para o intervalo de dose de interesse da proteção radiológica (até 20 mSv). Para tanto utilizou-se a dosimetria termoluminescente de albedo e a dosimetria de traços nucleares, técnicas consagradas na literatura internacional, empregando materiais de fabricação nacional e de baixo custo. Um policarbonato comercial, denominado SS-1, foi caracterizado para aplicação como detector sólido de traços nucleares. Os parâmetros para revelação química e ampliação dos traços, assim como a metodologia de avaliação dos detectores foram determinados. Estudou-se a resposta dos detectores TLD-600, TLD-700 e SS-1 em campos mistos nêutrongama de uma fonte de Amerício-Berílio e definiu-se um algoritmo para cálculo da dose de nêutrons e de radiação gama. A razão entre as respostas para nêutrons térmicos, de albedo e rápidos permite analisar o espectro ao qual o dosímetro foi submetido e corrigir a resposta do detector de traços para variações no ângulo de incidência da radiação. O novo dosímetro está pronto e apresenta desempenho para ser usado como dosímetro de nêutrons no Brasil. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
72

Metodo de coincidencia generalizado para a medida absoluta da atividade de radionuclideos .Aplicacao na determinacao do coeficiente de conversao da transicao de 279KeV do T1 203

MOURA, LAIS P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:29:35Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:36Z (GMT). No. of bitstreams: 1 01292.pdf: 4197340 bytes, checksum: e065f97f212a4098373c6cd14232d7c2 (MD5) / Tese (Doutoramento) / IPEN/T / Universidade Estadual de Campinas - UNICAMP/SP
73

Utilizacao de redes neurais artificiais para determinar o tempo de resposta de sensores de temperatura do tipo RTD / Time response of temperature sensors using neural networks

SANTOS, ROBERTO C. dos 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:08Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:44Z (GMT). No. of bitstreams: 0 / Em um reator nuclear PWR a temperatura do refrigerante do circuito primário e a da água de realimentação são medidas usando RTD (Resistance Temperature Detectors), ou termômetros de resistência. Estes RTDs alimentam os sistemas de controle e segurança da usina e devem, portanto, ser muito precisos e ter bom desempenho dinâmico. O tempo de resposta dos RTDs é caracterizado por um parâmetro denominado de Constante de Tempo, definido como sendo o tempo que o sensor leva para atingir 63,2% do seu valor final após sofrer uma variação de temperatura em forma de degrau. Este valor é determinado em laboratório, porém as condições de operação de reatores nucleares são difíceis de ser reproduzidas. O método LCSR (Loop Current Step Response), ou teste de resposta a um degrau de corrente, foi desenvolvido para medir remotamente o tempo de resposta dos RTDs. A partir desse teste, a constante de tempo do sensor é calculada através de uma transformação LCSR que envolve a determinação das constantes modais do modelo de transferência de calor. Este cálculo não é simples e requer pessoal especializado. Por este motivo, utilizou-se a metodologia de Redes Neurais Artificiais para estimar a constante de tempo do RTD a partir do LCSR. Os testes LCSR foram usados como dados de entrada da RNA; os testes de Imersão Rápida foram usados para determinar a constante de tempo dos sensores, sendo estes os valores desejados de saída da rede. Esta metodologia foi aplicada inicialmente a dados teóricos, simulando dez sensores com diferentes valores de constante de tempo, resultando em um erro médio de aproximadamente 0,74 %. Dados experimentais de 3 diferentes RTDs foram usados para estimar a constante de tempo, resultando em um erro máximo de 3,34 %. Os valores de constante de tempo estimados pelas RNAs foram comparados com aqueles obtidos pelo método tradicional, obtendo-se um erro médio de 18 % o que mostra que as RNAs são capazes de estimar a constante de tempo de uma forma precisa. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
74

Desenvolvimento de um sistema dosimetrico para feixes de eletrons de enegias altas

SOUZA, CLEBER N. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:34Z (GMT). No. of bitstreams: 1 05589.pdf: 5500511 bytes, checksum: e678ea0585ad825ea9f71a7ce347adb4 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
75

Desenvolvimento e calibracao de um dosimetro pessoal para neutrons utilizando detectores solidos de tracos nucleares

VILELA, EUDICE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:14Z (GMT). No. of bitstreams: 1 02811.pdf: 5186762 bytes, checksum: f178f608c95e9fecbaf736562e08dae5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:94/03409-4
76

Sobre a influencia de fatores ambientais nos niveis de radonio em cavernas dos Parques Estaduais do Vale do Ribeira, SP e avaliacao do equilibrio radioativo e fator de equilibrio entre radonio e seus descendentes / On the influence of environmental factors on radon levels in caves of Ribeira Valley State Parks, SP and evaluation of radioactive equilibrium and equilibrium factor between radon and its progeny

ALBERIGI, SIMONE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:13Z (GMT). No. of bitstreams: 0 / No presente estudo foi realizado monitoramento de radônio em cavernas distribuídas em três parques estaduais de São Paulo. As concentrações de radônio foram determinadas nas cavernas Morro Preto e Santana pertencentes ao Parque Estadual Turístico do Alto Ribeira (PETAR), na caverna do Diabo pertencente ao Parque Estadual de Jacupiranga (PEJ) e na caverna Colorida localizada no Parque Estadual Intervales (PEI). O monitoramento abrangeu medidas entre Abril de 2009 e Junho de 2010. As concentrações de radônio foram determinadas utilizando a técnica de detecção passiva com detectores de traços nucleares do estado sólido tipo CR-39 e câmaras de difusão NRPB. Os detectores foram expostos em períodos variando desde 30 até 150 dias. As concentrações de radônio variaram de 132 Bq/m3 a 9456 Bq/m3. Os resultados das concentrações de radônio foram analisados juntamente com informações sobre quantidade de chuvas no local monitorado, valores de temperatura interna e externa ao ambiente da caverna Santana e informações da literatura de chuva e temperatura na região para uma possível relação entre as variações nos níveis de radônio e informações climáticas. A determinação de 226Ra em amostras de água coletadas em algumas cavernas e rios da região e de radônio emanado da estalactite coletada na caverna Santana permitiu verificar que o radônio nas cavernas é proveniente das rochas das paredes. A verificação do equilíbrio radioativo entre 222Rn, 218Po e 214Po nos detectores expostos foi prejudicada pelas altas densidades de traços, comprometendo a eficácia da metodologia empregada. A dose efetiva anual foi calculada adotando três valores obtidos da literatura para o fator de equilíbrio. Para o cenário mais realista com fator de equilíbrio igual a 0,5 e considerando 52 semanas de trabalho, a dose efetiva anual foi de 5,1 mSv/a. Para o pior cenário que simula uma situação extrema adotando fator de equilíbrio igual a 1 e 52 semanas de trabalho, a dose efetiva anual é 10,2 mSv/a. Também com informações recebidas de uma empresa de monitoria da região sobre as horas que seus guias turísticos gastam mensalmente no interior das cavernas, foi feita estimativa de dose que resultou em uma dose efetiva anual total de 8,5 mSv/a para fator de equilíbrio 0,5 e, para a pior situação o resultado foi de 17,0 mSv/a para fator de equilíbrio 1. Todas as estimativas de doses mantiveram-se abaixo do limite para dose efetiva anual para exposição ocupacional de 20 mSv/a recomendado pela Comissão Internacional de Proteção Radiológica. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
77

Estudo espectroscopico nuclear no Sn-117 pela tecnica da correlacao angular

BORGES, JOAO B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:43Z (GMT). No. of bitstreams: 1 11261.pdf: 1447800 bytes, checksum: f0826edbe9dea480c0e4f236affa2502 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
78

Estudo e projeto de um sistema detetor nacionalizado para monitoracao de radiacao em embarcacoes

MORGADO, MARIO M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:27Z (GMT). No. of bitstreams: 1 06120.pdf: 6194545 bytes, checksum: 546fbeba149c18a9299f241f5498c61b (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
79

Desenvolvimento do processo de deposicao eletroforetica de boro em substratos de aluminio destinados a construcao de detectores de neutrons

SAMPA, MARIA H. de O. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:32Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:09Z (GMT). No. of bitstreams: 1 03259.pdf: 2834364 bytes, checksum: fcbdf9e370a39ffdb27be573e65f253c (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
80

Desenvolvimento de um sistema fonte-detector de radiacao para perfilagem gama em colunas de fracionamento de petroleo

VASQUEZ SALVADOR, PABLO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:52Z (GMT). No. of bitstreams: 1 09668.pdf: 6341914 bytes, checksum: 8514c212809df88b758a80f7ad2d2fd8 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0863 seconds