1

Estudio de los espectros de rayos X para la optimización del kerma en los exámenes de diagnóstico

Santa Cruz Delgado, José Santa, Santa Cruz Delgado, José January 2016 (has links)
El trabajo desarrollado tiene por objetivo reducir la dosis absorbida que reciben los pacientes en los exámenes de radiodiagnósticos con rayos X, mediante una evaluación de cada uno de los parámetros que modifican el espectro de rayos X. Por lo tanto, se analiza cómo se modifica el espectro de rayos X con la variación de los siguientes factores: el kilovoltaje en el tubo, la filtración y la corriente multiplicada por el tiempo (mAs), para ello, se determina primero el espectro continuo y discreto del haz de rayos X, empleando una simulación computacional, en donde usamos un programa que calcula la intensidad de los rayos X basados en la teoría de Birch y Marshall a partir de datos de entrada como valores de voltaje de tubo, filtración, corriente de tubo, ángulo del ánodo y factor de paso para la energía, luego, con la respuesta del programa (energía media y fluencia de fotones) y la teoría implicada se analiza la reducción del kerma en las técnicas propuestas. En este trabajo se ha reducido hasta en 56.69 % la dosis absorbida o el kerma para los pacientes en los exámenes radiográficos, Así como también, se propone la factibilidad de implementar, en forma alternativa, el uso de filtros de tantalio. Con la metodología desarrollada en este trabajo se demuestra que es posible optimizar e implementar nuevas técnicas radiológicas, las cuales reducen significativamente la dosis absorbida sobre el paciente, garantizando así la calidad y seguridad en los procedimientos de diagnóstico con rayos X. / --- This research aims to reduce absorbed dose of patients in clinical examinations using diagnostic X-ray, based on the results of the evaluation of each parameters that modify the X-ray spectrum. This study analyzes how to modify the X-ray spectrum with the variation of the following factors: tube potential (kVp), filtration and current multiplied by time (mAs). First, we determine the discrete and continuous X-ray spectrum using a computer simulation, this program that we use to calculate X-ray intensity is founded on the theory of Birch and Marshall. Moreover, from input data as values of tube potential, filtration, tube current, anode angle and a factor for energy, also with the program response (average energy and photon fluence), we analyze kerma reduction in the proposed techniques. We managed to reduce absorbed dose or kerma until 56,69 % in radiographic examinations. Besides this, we are studying the feasibility of implementing alternatively the use of tantalum filters in order to reduce absorbed dose of patients. The advantage of this methodology is that it is possible to optimize as well as implement new radiological techniques, which significantly reduce the absorbed dose. Therefore, guaranteeing the quality and safety in X-ray diagnostic procedures. / Tesis
2

Caracterização das qualidades de radiação X seguindo as recomendações da norma IEC 61267 no laboratório de calibração do IPEN / X RADIATION QUALITIES CHARACTERIZATION FOLLOWING THE STANDARD IEC 61267 RECOMMENDATIONS AT THE CALIBRATION LABORATORY OF IPEN

Franciscatto, Priscila Cerutti 16 September 2009 (has links)
Este trabalho apresenta uma metodologia para a caracterização das qualidades de radiação X, seguindo as novas recomendações do International Electrotechical Commission (IEC) com a norma 61267, para a implantação de um novo procedimento de calibração de sistemas dosimétricos utilizados na área de radiodiagnóstico. As qualidades de radiação de referência: RQR 2 a RQR 10, RQA 2 a RQA 10, RQB 2 a RQB 10 e RQN 2 a RQN 10 foram implantadas no laboratório de calibração do IPEN (LCI). Suas características foram analisadas por meio de medidas dos parâmetros destes feixes como: a tensão de pico prático (PPV), filtrações adicionais específicas para cada qualidade de radiação, 1ª e 2ª camadas semi-redutoras e coeficiente de homogeneidade. Para os filtros adicionais, foi utilizado alumínio de alta pureza em torno de 99,9%. A filtração inerente do tubo de raios X também foi determinada. Com a implantação destas qualidades de radiação, o LCI estará pronto para calibrar os instrumentos medidores de radiação nas novas qualidades recomendadas, permitindo assim, uma melhoria na qualidade dos serviços radiológicos que o IPEN oferece para todo o País. / This work presents a methodology for the X radiation qualities characterization following the new recommendations of the standard 61267 of the International Electrotechnical Commission (IEC) to establish a new procedure for calibration of dosimetric systems used in the field of diagnostic radiology. The reference qualities radiation of IEC 61267: RQR 2 to RQR 10, RQA 2 to RQA 10, RQB 2 to RQB 10 and RQN 2 to RQN 10 were implanted at the calibration laboratory of IPEN (LCI). Their characteristics were analyzed through measurements of beam parameters such as: Practical peak voltage (PPV), specific additional filtrations for each qualities (high purity aluminum of about 99.9%), 1st and 2nd Half Value Layers, homogeneity coefficient. The inherent filtration of the X ray tube was also determined. With the establishment of these radiation qualities, the LCI will be ready to calibrate the measuring instruments of radiation in the new qualities, allowing an improvement in radiological services offered by IPEN.
3

Desenvolvimento e implantação de um programa de controle e aquisição de dados na calibração de instrumentos em radiodiagnóstico / DEVELOPMENT AND IMPLANTATION OF A CONTROL AND DATA ACQUISITION PROGRAM FOR THE CALIBRATION OF INSTRUMENTS FOR DIAGNOSTIC RADIOLOGY

Betti, Flavio 27 September 2007 (has links)
Neste trabalho foram desenvolvidas as técnicas para projetar e implantar um sistema automatizado de controle e aquisição de dados para o arranjo de calibração em radiação X níveis diagnóstico e radioproteção do Laboratório de Calibração de Instrumentos (LCI) do IPEN. Os programas desenvolvidos fornecem diretamente os valores de kerma corrigidos para as condições ambientais. A automatização do obturador viabilizou a temporização precisa de exposições de curta duração. A utilização da câmara monitora como padrão de calibração beneficiou-se de um programa para a determinação de seus fatores de calibração a partir de uma câmara de referência para as diferentes qualidades de feixe. Foram utilizados como instrumentos de referência, dois eletrômetros, um para a câmara monitora, e outro para a câmara padrão; um termômetro de dois canais, e um barômetro absoluto, todos comunicando-se com o microcomputador através de interface padrão RS-232. São descritos os métodos computacionais utilizados nos programas de controle do kerma pela câmara monitora, bem como no de obtenção de seus fatores de calibração. A linguagem de programação adotada (LabVIEW MR) permitiu a obtenção de resultados rápidos e adequados. Os resultados obtidos demonstraram que o novo sistema proposto está apto a substituir as técnicas anteriormente adotadas no LCI, com vantagens no que diz respeito à rapidez e precisão na execução das calibrações, notadamente sob situações adversas, como as observadas em exposições muito curtas, ou então longas o suficiente para que sejam substancialmente afetadas pela flutuação de parâmetros tais como a taxa de kerma do gerador de raios X, ou então pelas condições ambientais de temperatura e pressão. / Design techniques of an automatic control system implementing corrected kerma determination and shutter command in the calibration laboratory at IPEN are shown, as well as the periodic calibration program developed for a monitor chamber for several X-ray beam qualities used for diagnostic radiology and radiation protection instruments. Two reference electrometers, a multichannel secondary standard thermometer, and an absolute pressure barometer were connected to the RS-232 interface from a PC computer equipped with a National Instruments multifunction analog and digital I/O card. LabVIEW MR was chosen as programming tool, which allowed for the development of a suite of programs for both controlling the shutter timing cycles and the calibration of the monitor chamber against a reference standard. A detailed description of the methods used for troubleshooting, fine tuning of parameters and evaluation of program results is followed by an analysis showing that considerable advantages regarding reduction of time and precision improvements during the calibrations could be achieved by the use of the developed programs, particularly under adverse conditions like those found during short expositions, or instead during long irradiation intervals where fluctuation of parameters like kerma rate or room conditions (temperature or pressure) can be found.
4

Desenvolvimento e implantação de um programa de controle e aquisição de dados na calibração de instrumentos em radiodiagnóstico / DEVELOPMENT AND IMPLANTATION OF A CONTROL AND DATA ACQUISITION PROGRAM FOR THE CALIBRATION OF INSTRUMENTS FOR DIAGNOSTIC RADIOLOGY

Flavio Betti 27 September 2007 (has links)
Neste trabalho foram desenvolvidas as técnicas para projetar e implantar um sistema automatizado de controle e aquisição de dados para o arranjo de calibração em radiação X níveis diagnóstico e radioproteção do Laboratório de Calibração de Instrumentos (LCI) do IPEN. Os programas desenvolvidos fornecem diretamente os valores de kerma corrigidos para as condições ambientais. A automatização do obturador viabilizou a temporização precisa de exposições de curta duração. A utilização da câmara monitora como padrão de calibração beneficiou-se de um programa para a determinação de seus fatores de calibração a partir de uma câmara de referência para as diferentes qualidades de feixe. Foram utilizados como instrumentos de referência, dois eletrômetros, um para a câmara monitora, e outro para a câmara padrão; um termômetro de dois canais, e um barômetro absoluto, todos comunicando-se com o microcomputador através de interface padrão RS-232. São descritos os métodos computacionais utilizados nos programas de controle do kerma pela câmara monitora, bem como no de obtenção de seus fatores de calibração. A linguagem de programação adotada (LabVIEW MR) permitiu a obtenção de resultados rápidos e adequados. Os resultados obtidos demonstraram que o novo sistema proposto está apto a substituir as técnicas anteriormente adotadas no LCI, com vantagens no que diz respeito à rapidez e precisão na execução das calibrações, notadamente sob situações adversas, como as observadas em exposições muito curtas, ou então longas o suficiente para que sejam substancialmente afetadas pela flutuação de parâmetros tais como a taxa de kerma do gerador de raios X, ou então pelas condições ambientais de temperatura e pressão. / Design techniques of an automatic control system implementing corrected kerma determination and shutter command in the calibration laboratory at IPEN are shown, as well as the periodic calibration program developed for a monitor chamber for several X-ray beam qualities used for diagnostic radiology and radiation protection instruments. Two reference electrometers, a multichannel secondary standard thermometer, and an absolute pressure barometer were connected to the RS-232 interface from a PC computer equipped with a National Instruments multifunction analog and digital I/O card. LabVIEW MR was chosen as programming tool, which allowed for the development of a suite of programs for both controlling the shutter timing cycles and the calibration of the monitor chamber against a reference standard. A detailed description of the methods used for troubleshooting, fine tuning of parameters and evaluation of program results is followed by an analysis showing that considerable advantages regarding reduction of time and precision improvements during the calibrations could be achieved by the use of the developed programs, particularly under adverse conditions like those found during short expositions, or instead during long irradiation intervals where fluctuation of parameters like kerma rate or room conditions (temperature or pressure) can be found.
5

Desenvolvimento de uma metodologia para a calibração de instrumentos de medida utilizados no controle da qualidade em radiodiagnóstico intervencional / Development of a calibration methodology for instruments used to interventional radiology quality control

Miranda, Jurema Aparecida de 30 April 2009 (has links)
Radiologia intervencional é a prática na qual imagens geradas por radiação-X são usadas como uma ferramenta na condução de procedimentos diagnósticos - terapêuticos. Tanto nos procedimentos para diagnósticos como nos terapêuticos, os tempos de exposição são longos, podendo causar graves lesões no paciente, e contribuindo para a dose espalhada no corpo clínico. O Brasil ainda não possui regras bem definidas quanto às doses e dosimetria de feixes fluoroscópicos. Há um grande interesse no estudo destes feixes, quanto a qualidade do feixe, camada-semi-redutora, entre outros parâmetros. Neste trabalho foi desenvolvida uma metodologia para a calibração de instrumentos de medida utilizados no controle de qualidade em radiodiagnóstico intervencional utilizando um sistema de radiação X clínico Medicor Neo Diagnomax, no modo fluoroscópico. Foi utilizada uma câmara de ionização plana marca PTW como monitora. Algumas câmaras de ionização recomendadas para fluoroscopia foram avaliadas e calibradas em relação à câmara de ionização de referência do laboratório de calibração do IPEN. Foram implantadas as qualidades de radiação RQR3, RQR5 e RQR7 e as específicas para a fluoroscopia RQC3, RQC5 e RQC7 seguindo as recomendações da norma IEC 61267. Todas as características dos feixes foram determinadas. Para a realização deste trabalho foi construído um sistema de posicionamento de câmaras de ionização. Para a determinação de dose de entrada e saída do paciente e de radiação espalhada na posição do corpo clínico, foram construídos simuladores de acrílico. Os resultados obtidos mostram uma taxa de Kerma de entrada no simulador de 4,5 x10-3, 1,2 x10-2 e 1,9 x 10-2 Gy/min para RQC 3, RQC 5, RQC 7 respectivamente. Foram realizados testes sem e com a colimação posicionada entre a câmara monitora e o simulador e os resultados encontrados mostram uma diferença de +5,5%, +0,6% e +0,8 %. Comprovando a importância da colimação nestes procedimentos intervencionistas. / Interventional radiology is the technique where X radiation images are used as a tool in the conduction of diagnostic or/and therapeutic procedures. The exposition times are long for both procedures, diagnostic and therapeutic, may cause serious injuries in the patient, and also contribute to the dose of the clinical staff. In Brazil there are not yet well established rules to determine the doses and to make the dosimetry in fluoroscopic beams. There is great interest in this study, in relation to the beam quality, the half-value-layer, and others parameters. In this work a Medicor Neo Diagnomax clinical X ray generator, fluoroscopy mode, was used to develop a calibration methodology for instruments used in interventional radiology quality control. One plane parallel ionization chamber PTW was used as monitor. The ionization chambers recommended for fluoroscopy measurements had been evaluated and calibrated in relation to the IPEN Calibration Laboratory reference ionization chamber. The RQR3, RQR5 and RQR7 radiation qualities and the specific ones for fluoroscopy, RQC3, RQC5 and RQC7, were established following the norm IEC 61267. All beams characteristics were determined. Ionization chambers positioning system and the acrylic phantoms to the entrance and exit doses determination were developed and constructed. The results obtained show air kerma rates of 4.5x10-3, 1.2x10-2 and 1.9x10-2 Gy/min for RQC3, RQC5 and RQC7 respectively. Tests with and without the collimation just after the monitor chamber, were carried out and the results showed a difference of +5.5%, +0.6% e + 0.8%, confirming the importance of the collimation use in these interventionist procedures.
6

Desenvolvimento de uma metodologia para a calibração de instrumentos de medida utilizados no controle da qualidade em radiodiagnóstico intervencional / Development of a calibration methodology for instruments used to interventional radiology quality control

Jurema Aparecida de Miranda 30 April 2009 (has links)
Radiologia intervencional é a prática na qual imagens geradas por radiação-X são usadas como uma ferramenta na condução de procedimentos diagnósticos - terapêuticos. Tanto nos procedimentos para diagnósticos como nos terapêuticos, os tempos de exposição são longos, podendo causar graves lesões no paciente, e contribuindo para a dose espalhada no corpo clínico. O Brasil ainda não possui regras bem definidas quanto às doses e dosimetria de feixes fluoroscópicos. Há um grande interesse no estudo destes feixes, quanto a qualidade do feixe, camada-semi-redutora, entre outros parâmetros. Neste trabalho foi desenvolvida uma metodologia para a calibração de instrumentos de medida utilizados no controle de qualidade em radiodiagnóstico intervencional utilizando um sistema de radiação X clínico Medicor Neo Diagnomax, no modo fluoroscópico. Foi utilizada uma câmara de ionização plana marca PTW como monitora. Algumas câmaras de ionização recomendadas para fluoroscopia foram avaliadas e calibradas em relação à câmara de ionização de referência do laboratório de calibração do IPEN. Foram implantadas as qualidades de radiação RQR3, RQR5 e RQR7 e as específicas para a fluoroscopia RQC3, RQC5 e RQC7 seguindo as recomendações da norma IEC 61267. Todas as características dos feixes foram determinadas. Para a realização deste trabalho foi construído um sistema de posicionamento de câmaras de ionização. Para a determinação de dose de entrada e saída do paciente e de radiação espalhada na posição do corpo clínico, foram construídos simuladores de acrílico. Os resultados obtidos mostram uma taxa de Kerma de entrada no simulador de 4,5 x10-3, 1,2 x10-2 e 1,9 x 10-2 Gy/min para RQC 3, RQC 5, RQC 7 respectivamente. Foram realizados testes sem e com a colimação posicionada entre a câmara monitora e o simulador e os resultados encontrados mostram uma diferença de +5,5%, +0,6% e +0,8 %. Comprovando a importância da colimação nestes procedimentos intervencionistas. / Interventional radiology is the technique where X radiation images are used as a tool in the conduction of diagnostic or/and therapeutic procedures. The exposition times are long for both procedures, diagnostic and therapeutic, may cause serious injuries in the patient, and also contribute to the dose of the clinical staff. In Brazil there are not yet well established rules to determine the doses and to make the dosimetry in fluoroscopic beams. There is great interest in this study, in relation to the beam quality, the half-value-layer, and others parameters. In this work a Medicor Neo Diagnomax clinical X ray generator, fluoroscopy mode, was used to develop a calibration methodology for instruments used in interventional radiology quality control. One plane parallel ionization chamber PTW was used as monitor. The ionization chambers recommended for fluoroscopy measurements had been evaluated and calibrated in relation to the IPEN Calibration Laboratory reference ionization chamber. The RQR3, RQR5 and RQR7 radiation qualities and the specific ones for fluoroscopy, RQC3, RQC5 and RQC7, were established following the norm IEC 61267. All beams characteristics were determined. Ionization chambers positioning system and the acrylic phantoms to the entrance and exit doses determination were developed and constructed. The results obtained show air kerma rates of 4.5x10-3, 1.2x10-2 and 1.9x10-2 Gy/min for RQC3, RQC5 and RQC7 respectively. Tests with and without the collimation just after the monitor chamber, were carried out and the results showed a difference of +5.5%, +0.6% e + 0.8%, confirming the importance of the collimation use in these interventionist procedures.
7

Caracterização das qualidades de radiação X seguindo as recomendações da norma IEC 61267 no laboratório de calibração do IPEN / X RADIATION QUALITIES CHARACTERIZATION FOLLOWING THE STANDARD IEC 61267 RECOMMENDATIONS AT THE CALIBRATION LABORATORY OF IPEN

Priscila Cerutti Franciscatto 16 September 2009 (has links)
Este trabalho apresenta uma metodologia para a caracterização das qualidades de radiação X, seguindo as novas recomendações do International Electrotechical Commission (IEC) com a norma 61267, para a implantação de um novo procedimento de calibração de sistemas dosimétricos utilizados na área de radiodiagnóstico. As qualidades de radiação de referência: RQR 2 a RQR 10, RQA 2 a RQA 10, RQB 2 a RQB 10 e RQN 2 a RQN 10 foram implantadas no laboratório de calibração do IPEN (LCI). Suas características foram analisadas por meio de medidas dos parâmetros destes feixes como: a tensão de pico prático (PPV), filtrações adicionais específicas para cada qualidade de radiação, 1ª e 2ª camadas semi-redutoras e coeficiente de homogeneidade. Para os filtros adicionais, foi utilizado alumínio de alta pureza em torno de 99,9%. A filtração inerente do tubo de raios X também foi determinada. Com a implantação destas qualidades de radiação, o LCI estará pronto para calibrar os instrumentos medidores de radiação nas novas qualidades recomendadas, permitindo assim, uma melhoria na qualidade dos serviços radiológicos que o IPEN oferece para todo o País. / This work presents a methodology for the X radiation qualities characterization following the new recommendations of the standard 61267 of the International Electrotechnical Commission (IEC) to establish a new procedure for calibration of dosimetric systems used in the field of diagnostic radiology. The reference qualities radiation of IEC 61267: RQR 2 to RQR 10, RQA 2 to RQA 10, RQB 2 to RQB 10 and RQN 2 to RQN 10 were implanted at the calibration laboratory of IPEN (LCI). Their characteristics were analyzed through measurements of beam parameters such as: Practical peak voltage (PPV), specific additional filtrations for each qualities (high purity aluminum of about 99.9%), 1st and 2nd Half Value Layers, homogeneity coefficient. The inherent filtration of the X ray tube was also determined. With the establishment of these radiation qualities, the LCI will be ready to calibrate the measuring instruments of radiation in the new qualities, allowing an improvement in radiological services offered by IPEN.
8

Análise comparativa de técnicas de cronometria de raios X aplicado ao radiodiagnóstico

Silva, Danubia Batista da 31 January 2013 (has links)
Submitted by Amanda Silva (amanda.osilva2@ufpe.br) on 2015-03-03T13:13:14Z No. of bitstreams: 2 Dissertação Danubia Batista.pdf: 2591234 bytes, checksum: 1ceb3b94f9bb6ef8b6897bc045393cca (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-03T13:13:14Z (GMT). No. of bitstreams: 2 Dissertação Danubia Batista.pdf: 2591234 bytes, checksum: 1ceb3b94f9bb6ef8b6897bc045393cca (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013 / FACEPE / O Ministério da Saúde publicou normas visando o controle de qualidade de equipamentos de radiodiagnóstico utilizados em clínicas ou hospitais com o propósito de garantir a qualidade dos serviços de exames de diagnose, os quais têm os raios X como ferramenta. Um dos parâmetros a ser monitorado é o tempo de exposição que os pacientes se submetem durante o exame de radiodiagnóstico. No entanto, existem poucos instrumentos capazes de cronometrar a exposição aos feixes de raios X, sobretudo quando se trata de um equipamento que emite raios X pulsados. Este trabalho apresenta comparações entre quatro diferentes instrumentos (Osciloscópio, ThinX, Dynalyzer e CronoX) que podem cronometrar o tempo de exposição de equipamentos de raios X. O instrumento de referência utilizado foi um osciloscópio digital calibrado contra um padrão secundário de tempo, o relógio atômico de rubídio. O ThinX e o Dynalyzer foram outros instrumentos eletrônicos de reconhecimento internacional que também forneceram medidas da cronometria de radiação. O CronoX, sistema de instrumentação desenvolvido pelo CRCN-NE, atualmente em fase de registro de patente, consistiu no principal instrumento deste trabalho pelo fato de que, além de fornecer resultados com alta precisão e resolução de microssegundos, ele também pode cronometrar o tempo dos feixes de raios X pulsados, o que representa uma inovação do estado da técnica na cronometria em radiodiagnóstico. Assim, este estudo apresenta um novo procedimento padrão para cronometria da exposição aos feixes de raios X diagnósticos baseado no CronoX.
9

Avaliação da utilidade do 99mTc (V) DMSA na detecção de metástase ósseas

CORREIA, Marília Bezerra Libório January 2007 (has links)
Made available in DSpace on 2014-06-12T23:17:13Z (GMT). No. of bitstreams: 2 arquivo9148_1.pdf: 4473190 bytes, checksum: 885ade50a3ae503aa32fb6e5626cf62f (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / As metástases ósseas são uma grande causa de morbidade e mortalidade nos pacientes com câncer, podendo acarretar em dores, hipercalcemia, fraturas patológicas e deficiências neurológicas. A cintilografia óssea, empregada na detecção dessas metástases, é um método sensível à alterações no metabolismo ósseo, no entanto, como as lesões benignas também captam os fármacos 99mTcdifosfonatos, sua especificidade torna-se baixa tendo sido propostas novas alternativas para orientar um diagnóstico mais específico. Radiofármacos marcados com 99mTc para diagnóstico de tumores são limitados quanto a seus propósitos, mas muitos estudos tem se dirigido ao 99mTc(V)DMSA, que é um radiofármaco com afinidade tumoral cuja captação é descrita em metástases ósseas e tumores de tecidos moles. Seu mecanismo de acumulação tem sido investigado para elucidar o comportamento biológico e aplicabilidade clínica, no entanto o 99mTc(V)DMSA ainda não é produzido no Brasil como um kit liofilizado. O objetivo deste trabalho foi obter o 99mTc(V)DMSA a partir de um kit liofilizado nacional de DMSA e avaliar sua utilidade na detecção de metástases ósseas em humanos mediante imagem cintilográfica, com emprego prévio em modelo animal. O 99mTc(V)DMSA foi preparado a partir de kits comercialmente viáveis de DMSA (IPEN), pela redução do pH, o 99mTc-DMSA e o 99mTc-MDP foram preparados segundo as instruções do fabricante. A qualidade dos fármacos foi analisada por testes de pH, pureza radionuclídica e radioquímica. Os ensaios de biodistribuição foram realizados em camundongos: os grupos controle receberam 99mTc-DMSA (veia da cauda), enquanto os grupos experimentais receberam 99mTc(V)DMSA, após 30min ou 1h, os animais foram sacrificados e a atividade específica dos órgãos determinada. Na experimentação humana, dez pacientes com neoplasias malignas comprovadas histologicamente se submeteram à aquisição de imagens de corpo inteiro 3h após a administração de 99mTc-MDP (exame de rotina) assim como 3h e 24h após a administração de 99mTc(V)DMSA, foram analisados ainda outros exames de imagem (TC, RMN, Rx). Os resultados do controle de qualidade indicaram que o 99mTc(V)DMSA apresentou marcação e estabilidade adequadas para o uso clínico. A biodistribuição revelou uma redução na razão rim/osso de 16,30 ± 2,24 (III-DMSA) para 0,77 ± 0,24 (V-DMSA), estando os percentuais de captação/g de acordo com a literatura. Na experimentação humana, as imagens de 99mTc(V)DMSA foram concordantes com as de 99mTc-MDP em 80% dos casos. O 99mTc(V)DMSA não foi captado em lesões provocadas por trauma e houve um caso de falso negativo. Os resultados deste estudo sugerem que o 99mTc(V)DMSA poderia ser útil da diferenciação entre lesões traumáticas e metastáticas, devendo a captação do 99mTc(V)DMSA ser observada quanto às implicações prognósticas
10

Avaliação do código de simulação Monte Carlo PENELOPE para aplicações em geometrias delgadas e feixes de radiodiagnóstico / Evaluation of the PENELOPE Monte Carlo simulation code for applications in thin geometry and radiodiagnostic beams

Pianoschi, Thatiane Alves 28 November 2008 (has links)
O uso de códigos de simulação Monte Carlo em radiologia vem crescendo com o aparecimento de diferentes códigos de simulação, desenvolvidos especificamente para aplicações em radiologia, como, por exemplo, PENELOPE. Cada um desses códigos utiliza diferentes algoritmos para o transporte de partículas resultando em diferentes níveis de dificuldade de uso, acurácia nos resultados e desempenho nas simulações. O código de simulação Monte Carlo PENELOPE utiliza um algoritmo misto de transporte da radiação, definido por meio dos parâmetros de entrada da simulação. Normalmente utilizado para aplicações em feixes de altas energias, a influência desses parâmetros no transporte de partículas com o código PENELOPE ainda não foi completamente estabelecida para aplicações que utilizam feixes de radiodiagnóstico e geometrias delgadas. Especificamente em estudos de características dosimétricas de detectores de radiação que possuem espessuras delgadas, como câmaras de ionização, o tipo de algoritmo de transporte pode influenciar nos resultado das simulações. Neste trabalho, o estudo da influência dos parâmetros que controlam o algoritmo de transporte utilizado pelo código de simulação Monte Carlo PENELOPE em feixes de radiodiagnóstico e geometrias delgadas foi realizado através da simulação dos coeficientes de atenuação linear em diferentes materiais, espessuras e energias. A validação desse código nessa faixa de energia permitiu a determinação do fator de retroespalhamento para feixes polienergéticos, contribuindo para sua aplicação em radiodiagnóstico. / The use of Monte Carlo simulation in radiology has been growing with the appearance of different simulation codes that have been developed specifically for applications in radiology, as for example PENELOPE. Each of these codes use different algorithms for particle transport resulting in different levels of difficulty for its use as well as of accuracy and performance. The PENELOPE code uses a mixed algorithm for radiation transport that is defined by entrance parameters. Most of the applications of PENELOPE code have been performed with high energy beams, however the influence of the entrance parameters in the particle transport is not established for applications evolving radiodiagnostic beams and thin geometries. Specifically for the study of dosimetric characteristics of radiation detectors that have small thicknesses, as ionization chambers, the algorithm transport influences the results of the simulation. In this work, the study of the influence of entrance parameters on the transport algorithm used in PENELOPE Monte Carlo simulation code was performed by the simulation of the linear attenuation coefficients in different materials, thickness and energies used in radiodiagnostic. The validation of this code in such energy range allowed the determination of the backscatter factor for polienergetic beams, aiding its application in radiodianogsis.