• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 29
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 81
  • 29
  • 22
  • 17
  • 15
  • 15
  • 13
  • 12
  • 11
  • 11
  • 11
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Stereotactic radiosurgery as salvage treatment for locally recurrent nasopharyngeal carcinoma

Chua, T. T., Daniel. January 2006 (has links)
Thesis (M. D.)--University of Hong Kong, 2006. / Title proper from title frame. Also available in printed format.
2

Investigation of Rotational Deviations on Single Fiducial Tumor Tracking with Simulated Respiratory Motion using Synchrony® Respiratory Motion Tracking for Cyberknife® Treatment

Unknown Date (has links)
It is hypothesized that the uncertainty of the Synchrony® model from the rotation of a geometrically asymmetrical single fiducial shall be non-zero during the motion tracking. To validate this hypothesis, the uncertainty was measured for a Synchrony® model built for a respiratory motion phantom oriented at different yaw angles on a Cyberknife® treatment table. A Mini-ball Cube with three cylindrical GoldMark™ (1mmx5mm Au) numbered fiducials was placed inside a respiratory phantom and used for all tests. The fiducial with the least artifact interference was selected for the motion tracking. A 2cm periodic, longitudinal, linear motion of the Mini-ball cube was executed and tested for yaw rotational angles, 0° – 90°. The test was repeated over 3 nonconsecutive days. The uncertainty increased with the yaw angle with the most noticeable changes seen between20° and 60° yaw, where uncertainty increased from 23.5% to 57.9%. A similar test was performed using a spherical Gold Anchor™ fiducial. The uncertainties found when using the Gold Anchor™ were statistically lower than those found when using the GoldMark™ fiducial for all angles of rotation. For the first time, it is found that Synchrony® model uncertainty depends on fiducial geometry. In addition, this research has shown that tracking target rotation using a single fiducial can be accomplished with the Synchrony® model uncertainty as it is displayed on the treatment console. The results of this research could lead to decreased acute toxicity effects related to multiple fiducials. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2018. / FAU Electronic Theses and Dissertations Collection
3

Stereotactic radiosurgery as salvage treatment for locally recurrent nasopharyngeal carcinoma

Chua, T. T., Daniel., 蔡清淟. January 2006 (has links)
published_or_final_version / abstract / Medicine / Master / Doctor of Medicine
4

Computation and optimization of dose distributions for rotational stereotactic radiosurgery

Fox, Timothy Harold 05 1900 (has links)
No description available.
5

Using regression techniques for the automated selection of radiosurgery plans

Wenner, Lisa Ellen 05 1900 (has links)
No description available.
6

Is waiting time a quality service indicator for radiotherapy treatment? the effect of waiting time on local tumour control for nasopharyngeal carcinoma patients in Hong Kong /

Tze, Mei-yu, Jadie. January 2006 (has links)
Thesis (M. P. H.)--University of Hong Kong, 2006. / Also available in print.
7

Is waiting time a quality service indicator for radiotherapy treatment? : the effect of waiting time on local tumour control for nasopharyngeal carcinoma patients in Hong Kong /

Tze, Mei-yu, Jadie. January 2006 (has links)
Thesis (M.P.H.)--University of Hong Kong, 2006.
8

Physical parameters of very small diameter 10 MV x-ray beams for linac-based stereotactic radiosurgery

Sham, Edwin. January 2008 (has links)
No description available.
9

Dosimetric and Radiobiological Comparison of the Effects of High Definition versus Normal Collimation on Treatment Plans for Stereotactic Lung Cancer Radiation Therapy

Unknown Date (has links)
Stereotactic Body Radiation Therapy (SBRT) is a modern precision radiation therapy to deliver the dose in 1 to 5 fractions with high target dose conformity, and steep dose gradient towards healthy tissues. The dose delivered is influenced by the leaf width of the MLC, especially in case of SBRT. Treatment plans with high definition (HD) MLC having leaf-width 2.5 mm and normal MLC having leaf-width 5 mm, were compared to quantify dosimetric and radiobiological parameters. Dosimetric parameters conformity indices (CI), gradient indices (GI) and heterogeneity indices (HI) were compared. The radiobiological parameters were evaluated by normal tissue complication probability (NTCP) and tumor control probability (TCP) based on the equivalent uniform dose (EUD). The results show that there is dosimetric and radiobiological merit of the HD MLC over the normal MLC. However, the improvement is not consistent with all the plans and thus further research is required prior to conclusion. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2018. / FAU Electronic Theses and Dissertations Collection
10

Influence de la distribution de dose d’irradiation dans la variation de l’effet radiobiologique du traitement radiochirurgical par Gamma Knife / Influence of radiation dose distribution in radiobiological modifications after Gamma Knife radiosurgery

Massager, Nicolas 18 February 2008 (has links)
La radiochirurgie par Gamma Knife constitue une modalité thérapeutique reconnue de certaines affections cérébrales. Le traitement se base sur l’administration d’un rayonnement focalisé au niveau d’une cible intracrânienne. L’efficacité de ce traitement repose sur la délivrance d’une dose d’irradiation efficace au sein d’un volume-cible associé à la délivrance d’une dose d’irradiation négligeable à l’extérieur de ce même volume-cible. En pratique, la dose d’irradiation administrée à l’intérieur du volume-cible n’est pas distribuée de manière homogène, et la dose d’irradiation reçue par les tissus situés en-dehors du volume-cible n’est pas nécessairement faible. Notre travail est basé sur l’hypothèse que l’imperfection de la distribution de la dose d’irradiation au sein du volume-cible et en-dehors de celui-ci peut être responsable des échecs et des complications rencontrées en radiochirurgie. Dans deux modèles cliniques de traitement radiochirurgical, le schwannome vestibulaire et la névralgie du trijumeau, nous avons montré qu’il existait une relation entre les paramètres de distribution de dose d’irradiation et certains résultats du traitement radiochirurgical par Gamma Knife de ces pathologies. Nous avons développé deux modèles expérimentaux d’irradiation radiochirurgicale de rats, l’un ciblé sur le striatum et l’autre sur le nerf trijumeau, permettant d’analyser les conséquences histologiques des variations de la distribution de dose à l’intérieur du volume-cible ainsi qu’à distance de celui-ci. Nous avons démontré que la réponse radiobiologique des tissus irradiés était fortement dépendante de ce paramètre dosimétrique, et que ce dernier constituait une donnée de la planification chirurgicale aussi importante que la dose de prescription. Nous avons corrélé ces résultats avec certaines observations réalisées dans d’autres indications de traitement radiochirurgical ainsi que dans l’analyse histologique de tumeurs traitées par Gamma Knife. Ces études mettent en évidence le rôle important joué par l’optimalisation de la distribution de la dose d’irradiation dans l’amélioration des résultats cliniques du traitement radiochirurgical. Les valeurs optimales de la distribution de dose dans les différentes indications de traitement radiochirurgical doivent être recherchées, et les différentes méthodes mises à notre disposition lors de la planification dosimétrique pour améliorer la distribution de dose doivent être utilisées avec discernement pour obtenir la dosimétrie radiochirurgicale la plus parfaite possible.

Page generated in 0.0409 seconds