• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1943
  • 43
  • 24
  • 21
  • 21
  • 21
  • 11
  • 10
  • 9
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 2025
  • 1645
  • 856
  • 732
  • 368
  • 365
  • 257
  • 214
  • 209
  • 207
  • 177
  • 171
  • 170
  • 169
  • 168
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo de uma tecnica pulsante de difração de raios-X

Retz, Claudia Maria 21 July 1978 (has links)
Orientadores: Stephenson Caticha Ellis, Iris Concepcion Linares de Torriani / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-09-27T18:22:52Z (GMT). No. of bitstreams: 1 Retz_ClaudiaMaria_M.pdf: 1955996 bytes, checksum: 41377763b5920390a6eabd188461baf1 (MD5) Previous issue date: 1978 / Resumo: Não informado / Abstract: Not informed / Mestrado / Física / Mestre em Física
12

Obtenção de imagens com raios x fluorescentes

Bicalho, Hamilton Araujo 16 October 1991 (has links)
Orientador: Stephenson Caticha-Ellis / Tese (doutorado) - Universidade Estadualde Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-09-27T18:40:21Z (GMT). No. of bitstreams: 1 Bicalho_HamiltonAraujo_D.pdf: 7138235 bytes, checksum: a04e7af2999c5478c975659de8db6905 (MD5) Previous issue date: 1991 / Resumo: A formação de imagens com raios X fluorescentes não tinha sido desenvolvida até o presente. Neste trabalho são apresentados dois novos métodos de formação de imagens com raios X fluorescentes. Eles produziram imagens que consideramos como o primeiro passo de um novo campo de pesquisa. Eles apresentam algumas vantagens com relação aos tradicionais devido à natureza desta radiação, especialmente a de ser emitida sob forma de raias características. a) Radiografia de um corpo com um feixe de radiação característica que denominamos de Radiografia Monocromática. (Tempos de exposição: da ordem do mseg.). b) Imagem obtida com a fluorescência emitida pelo próprio corpo, excitada com radiação escolhida convenientemente, que denominamos de Imagem Fluorescente. (Tempos de exposição: um par de minutos). Consegue-se um feixe adequado mediante o uso de um elemento fluorescedor, que converte de forma simples, prática e eficiente um certo espectro de radiação (até as bordas de absorção do fluorescedor) em outro, bem determinado, formado pelas linhas características do elemento. Deste modo, radiação branca de um gerador convencional de raios X pode ser transformada em radiação característica de comprimento de onda numa região predeterminada. O método (b) permite obter várias imagens simultaneamente. Duas destas constituem um par estereoscópico e permitem visualizar a imagem tridimensional do interior da amostra. Os métodos desenvolvidos decrescem consideravelmente o risco de irradiação ja que a radiação característica incidente, escolhida convenientemente para excitar o elemento opacificador, é pouco absorvida pelos tecidos animais. A quantidade estimada de opacificador é duas ordens de grandeza menor que nos métodos tradicionais devido a que ele é excitado preferencialmente / Abstract: Imaging by using X-Ray fluorescent radiation had not been developed till now. In this work two new methods of X-ray fluorescent imaging were developed. They have produced images which are to be considered as the first step in a new field. a) "Monochromatic Radiography" (Typical exposure times are of about 1 msec.) .Radiography obtained by using characteristic radiation. b) "Fluorescent Image Method" (Exposure time of about two minutes). The image obtained of a body by using the characteristic radiation emitted by an atom selectively excited by another properly chosen characteristic radiation. An adequate characteristic beam is obtained from a plate made out of a pure element irradiated with a full white spectrum of a conventional generator. This fluorescent element converts it up until the absorption edge, in a practical, efficient and simple way in another spectrum made out of discrete characteristic lines of the element. Thus, white radiation from a conventional generator is transformed to characteristic radiation of wavelengths in a given region. Method (b) may produce several simultaneous images. A couple of them is an stereoscopic pair and the three dimensional internal structure of the body can then be visualized. The new methods have some implicit advantages when compared with traditional methods, with regard to decreased body irradiation since the hard monochromatic radiation is nearly not absorved by the light elements of the animal tissues. In addition, the estimated amount of opacifier is about two orders of magnitude smaller than in classical methods since it is selectively excited here / Doutorado / Física / Doutor em Ciências
13

Contribuição do efeito de tamanho de grão cristalino a largura de linha Raman e de difração de raios-x

Santos, Denise Ribeiro dos 30 April 1992 (has links)
Orientador: Iris Concepcion Linares de Torriani / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-09-27T18:30:59Z (GMT). No. of bitstreams: 1 Santos_DeniseRibeirodos_M.pdf: 1895377 bytes, checksum: 6a4dbc0fd4b0ba660c304372792426ad (MD5) Previous issue date: 1992 / Resumo: É bem sabido que a forma de linha de difração de raios-x está relacionada com a cristalinidade do material, e que podemos estimar o tamanho médio dos grãos cristalinos (L) em várias direções na rede analisando o pico de raios-x correspondente. Um efeito equivalente ocorre no espectro de espalhamento Raman de um semicondutor microcristalino, conforme pode ser observado em publicações de vários grupos experimentais e teóricos nos últimos anos. Com base na teoria proposta por Richter e outros [Ri1] para o espectro Raman devido a fônons semi-confinados no volume de pequenos grãos esféricos, obtemos uma expressão analítica para a forma de linha Raman de germânio microcristalino. Utilizando uma subrotina de ajuste de curvas baseada no método de mínimos quadrados, ajustamos a expressão obtida aos dados experimentais de vários filmes de mc-Ge, obtendo como resultado do ajuste o diâmetro médio dos grãos. Considerando que estes obedecem uma distribuição gaussiana de tamanhos, determinamos também a largura aL dessa distribuição para cada amostra, conseguindo uma concordância muito boa entre a expressão teórica e os dados experimentais. Comparando os valores encontrados com os resultados obtidos pela técnica usual de raios-x, concluímos que o novo método de cálculo de L é viável, sendo que os resultados têm uma boa concordância com L medido por raios-x nos casos em que se pode dizer que a aproximação de grãos esféricos é válida / Abstract: It is well known that the X-ray diffraction line shape is related to the crystallinity of the sample material. The average size of the crystallites (L) in certain lattice directions can be evaluated from the broadening of the corresponding X-ray line. A similar effect is observed in the Raman spectrum of micro-crystalline semiconductors. This subject has been discussed and applied in sever al publications of experimental and theoretical groups during the last few years. Based on the theory proposed by Richter et at [Ri1] for the Raman spectrum due to partially confined fonons in the volume of small spherical grains we can obtain an analytical expression for the Raman line of micro-crystalline Ge. Using a curve fitting sub-routine based on the least squares method we proceeded to fit the experimental data obtained from several mc-Ge samples with the proposed analytical expression. The average crystallite size was obtained directly from the fitting parameters. Assuming a Gaussian size distribution we determined the corresponding aL parameters for each sample, getting to a very good agreement between the experimental data and the theoretical calculation. Making a comparison of the values obtained using this analysis of the Raman line and the usual X-ray diffraction technique, we were able to conclude that both techniques will give similar results for the crystallite measurement only in those cases in which the approximation of "spherical" grains is valid / Mestrado / Física / Mestre em Física
14

Segmentação da grade costal em imagens de Raio-X pulmonar

Moreira, Rui André Areias da Silva January 2005 (has links)
Tese de mestrado. Faculdade de Engenharia. Universidade do Porto. 1998
15

Pára-raios de óxido de zinco

Moura, António Carlos Sepúlveda Machado e January 1983 (has links)
Trabalho complementar das provas de doutoramento na Faculdade de Engenharia da Universidade do Porto
16

Detector para raios X usando sensor LDR para mensurar a energia dos fótons emitidos e testar a eficiência de aparelhos hospitalares / Detector for X-rays using LDR sensor to measure of energy and photon emission testing the efficiency of hospital equipment

Vasconcelos, Edgard Rogério de Siqueira 28 February 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós- Graduação em Engenharia Biomédica, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2014-07-01T13:59:53Z No. of bitstreams: 1 2014_EdgardRogerioSiqueiraVasconcelos.pdf: 4164864 bytes, checksum: 7fc2ef139b3818d1a4e3eafcb9e6d85e (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-07-01T17:17:57Z (GMT) No. of bitstreams: 1 2014_EdgardRogerioSiqueiraVasconcelos.pdf: 4164864 bytes, checksum: 7fc2ef139b3818d1a4e3eafcb9e6d85e (MD5) / Made available in DSpace on 2014-07-01T17:17:57Z (GMT). No. of bitstreams: 1 2014_EdgardRogerioSiqueiraVasconcelos.pdf: 4164864 bytes, checksum: 7fc2ef139b3818d1a4e3eafcb9e6d85e (MD5) / A presente pesquisa descreve o estudo com um sensor de LDR desenvolvido para detectar raios X. Com o sensor, foi possível medir a voltagem produzida pelo sensor quando irradiado por feixe de raios X e relacionar com a intensidade relativa do feixe e comparar este resultado por meio da relação voltagem medida/intensidade relativa para testar a eficiência do aparelho de raios X testado e a relação entre o kV e mAs usados durante os testes. Pelos testes, contatou-se que o sensor de LDR é sensível aos raios X e os resultados encontrados foram satisfatórios. A relação V/IR permitiu estabelecer um coeficiente padrão para realização de testes de comparação com outros aparelhos de raios X com as mesmas características do aparelho testado. Com os resultados encontrados foi realizado teste de significância das estimativas pelo modelo da significância dos efeitos da medida pelo Teste de Wald por meio do SPSS. Este recurso traduziu excelentemente os valores do p-valor calculados, considerando a significância de 5%. Pelos resultados encontrados menores que 0,001 para o p-valor foi possível concluir que os valores estimados são estatisticamente diferentes de zero. Com relação ao R² também calculado, ele expressou o quanto as variáveis utilizadas no teste estão explicando a variável resposta (valor líquido da voltagem medida pelo sensor), considerando que esse valor esteve acima de 0,9 e, portanto mais próximo de 1, mostrando que a variável independente está explicando as respostas de forma excelente. Os resultados obtidos foram acima de 90%, mostrando que as variáveis inseridas explicaram muito bem o valor líquido e que, portanto, o sensor de LDR mostrouse eficiente para detecção de raios X. ______________________________________________________________________________ ABSTRACT / This study describes a study with a LDR sensor designed to detect X-rays with the sensor, it was possible to measure the voltage produced by the sensor when irradiated by X-ray beam and relate to the relative intensity of the beam and comparing this result by the measured voltage ratio/relative intensity to test the efficiency of the X-ray unit tested and the relationship between kV and mAs used during testing. By testing if contacted that the LDR sensor is sensitive to X-rays and the results were satisfactory. The V/IR relation allowed us to establish a standard coefficient for conducting comparison with other X-ray machines with the same characteristics of the tested unit tests. Based on the results was performed by the model estimates significance of the significance of the effects of the Wald test using SPSS test. This feature excellently translated values of the p-value calculated considering the significance of 5%. By less than 0,001 results found for the pvalue was possible to conclude that the estimated values are statistically different from zero. With respect to R² also calculated, he expressed how the variables used in the test are explaining the answer (net value of the voltage measured by the sensor) variable, where as this value was above 0.9 and therefore closer to 1, showing that the independent variable is explaining the answers excellently. The results were above 90%, showing that the inserted variables explained very well the net value and therefore, the sensor LDR was efficient to detect X-ray.
17

Desenvolvimento de um sistema de digitalização tridimencional de superfícies baseado em visão computacional com varredura a laser para uso em metrologia dimensional

Ginani, Luciano Selva 28 May 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2008. / Submitted by Thaíza da Silva Santos (thaiza28@hotmail.com) on 2011-02-12T18:01:21Z No. of bitstreams: 1 2008_LucianoSelvaGinani.pdf: 6242846 bytes, checksum: 682889473487bde256638d9042a1a436 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2011-04-02T00:41:38Z (GMT) No. of bitstreams: 1 2008_LucianoSelvaGinani.pdf: 6242846 bytes, checksum: 682889473487bde256638d9042a1a436 (MD5) / Made available in DSpace on 2011-04-02T00:41:38Z (GMT). No. of bitstreams: 1 2008_LucianoSelvaGinani.pdf: 6242846 bytes, checksum: 682889473487bde256638d9042a1a436 (MD5) / A grande maioria dos sistemas atuais de digitalização tridimensional de superfícies baseia-se no uso de sensores de posicionamento para a medição da rotação de uma fonte emissora de luz. Esses sensores impõem restrições sobre o volume e a distância de trabalho do digitalizador e, como a reconstrução é normalmente baseada em equações de triangulação, eles também geram incertezas de medição devido à relação não-linear entre a posição angular e a distância. Para superar essas dificuldades, removendo a necessidade do uso de sensores angulares de posição de alto custo e aumentando a distância de medição, apresenta-se nesse trabalho o desenvolvimento de um sistema de digitalização tridimensional de superfícies compacto, de fácil transporte e auto-calibrável. Com o uso de técnicas de visão computacional elimina-se a necessidade de qualquer tipo de sensor de posicionamento e com o sistema de auto-calibração desenvolvido dispensa-se a necessidade de outros sistemas de medição para a calibração. Todas as técnicas de calibração de câmeras, processamento de imagens e a arquitetura completa do sistema são discutidas e apresentadas junto com um comparativo do sistema desenvolvido e sistema comerciais e em desenvolvimento em diferentes instituições de pesquisa e desenvolvimento. _________________________________________________________________________________ ABSTRACT / Most of today’s 3D laser scanning systems for object model digitalization rely on angular position sensors to measure rotation of a laser diode and to reconstruct the object. However, those types of sensors restrict the object size in target and its distance from the image sensor, since reconstruction is usually based on equations for geometric triangulation, leading to high measurement errors due to the non-linear relation between angular positions and distances. In order to overcome the need of high cost angular position sensors and to increase measurement distances it is proposed here a 3D surface scanner based on computer vision that is compact, easy to transport and self-calibrated. The system calibration includes camera calibration using radial alignment constraints, image processing routines and determination of system parameters. The complete system architecture with two laser diodes and a single camera is shown, the theoretical basis, hardware implementation and practical results obtained are presented, discussed and compared with different systems available.
18

Investigação dos Efeitos do Campo Magnético no Transporte no Supercondutor (Hg,Re)-1223.

ROCHA, J. R. 14 December 2012 (has links)
Made available in DSpace on 2018-08-01T22:29:36Z (GMT). No. of bitstreams: 1 tese_6208_.pdf: 2111562 bytes, checksum: 1d27a253dbdd298cb2dee8db6a7f6e3b (MD5) Previous issue date: 2012-12-14 / Realizamos o estudo do efeito da oxigenação nas propriedades de transporte no sistema policristalino Hg0,82Re0,18Ba2Ca2Cu3O8+d (Hg,Re)-1223. Especificamente, o nosso objetivo é determinar a influência da oxigenação nas medidas de resistividade elétrica, além disto, propor um método sistemático para medir a resistividade elétrica. Para este fim foram obtidas amostras de Hg0,82Re0,18Ba2Ca2Cu3O8+d preparada através de precursores tratados termicamente com diferentes pressões parciais de oxigênio 5% (amosta A), 10% (Amostra B), 15% (Amostra C) . Em principio, utilizou-se 1 mol de Ba2Ca2Cu3O7,17 foram adicionados 0,18 moles de ReO2 em forma de p´o . Os percusores preparados termicamente foram então misturados a HgO. Através de MEV e Raios X (EDS) verificou se que as amostras têm morfologia semelhante dos grãos. Utilizando imagens de SEM um histograma com o tamanho das junções foi feito e verificou se que os tamanho médio das junções é representado por uma função de distribuição gama . Finalmente, as amostras foram submetidas a resistividade elétrica AC com baixo campo aplicado (400 Oe). As medições foram feitas por meio de técnica de sondas e barras de aproximadamente 7x1x1mm3. A temperatura em que a resistência é zero (TZ) foram determinados a partir de R(T). Os resultados foram qualitativamente analisados por meio do aprisionamento (flux traping) do campo pelos grãos .
19

Estudo da liga de aluminio-cobre, como filtração alternativa para radiação X

Gonçalves, Andrea 28 June 2000 (has links)
Orientador: Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-26T21:18:16Z (GMT). No. of bitstreams: 1 Goncalves_Andrea_D.pdf: 2751016 bytes, checksum: d2197243c4236383286bc9a4952e0c59 (MD5) Previous issue date: 2000 / Resumo: Neste trabalho foi estudado o efeito da filtração alternativa de liga de alumínio-cobre em aparelho de raios X odontológicos, avaliando a redução da taxa de kerma no ar, o espectro de energia dos raios X e as alterações na qualidade da imagem radiográfica. O estudo foi realizado comparando várias espessuras do filtro de liga de alumínio-cobre, utilizando porcentagens de 2%, 3% e 4% do elemento cobre na liga, com o filtro padrão de alumínio. Os experimentos foram feitos utilizando-se um aparelho de raios X odontológico convencional operando com 60kVp e 70kVp, utilizando filmes do grupo D e E, obtendo radiografias com auxílio de um fantoma de segmento de mandíbula e de uma escala de densidade confeccionada com alumínio laminado. A liga de alumínio-cobre permitiu o endurecimento e a filtração do feixe de raios X em relação ao filtro de alumínio. O uso do filtro de liga de alumínio-cobre resultou em 4,33% a 47,33% de redução da taxa média de kerma no ar e indicou contraste da imagem radiográfica sem alteração, quando comparado com a filtração de alumínio, mostrando que os filtros de liga de alumínio-cobre tomam-se alternativas aceitáveis em relação aos filtros de alumínio, considerando que, para o filtro de liga de alumínio-cobre, os tempos de exposição foram iguais ou menores que os utilizados para o filtro padrão de alumínio / Abstract: This investigation studied the effect of aluminum-copper alloy filtration as an alternative to the dental x-ray beam to assess reduction in x-ray exposure, photon spectra and changes in image quality. The study was made by comparing various thicknesses of aluminum-copper alloy in three different percentages, 2%, 3% and 4% of copper in the alloy, with an aluminum filter. Trials were conducted with an intra-oral dental x-ray unit, using 60kVp and 70kVp, and were done in mandible phantom and in step wedge. Depending on the thickness of the aluminum-copper alloy, the beam could be hardened and filtrated, when compared to using aluminum filtration. The use of the aluminum-copper alloy filters resulted in 4,33% to 47,33% reduction in x-ray exposure and the same image contrast when compared with aluminum filtration, which made them viable as acceptable alternatives to aluminum filtration, considering that the time exposure to aluminum copper alloy filtration was the same as or less than that for aluminum filtration / Doutorado / Doutor em Radiologia Odontológica
20

Análise de eventos Centauro

Barroso, Sergio Luiz Carmelo 22 January 2001 (has links)
Orientador: Edison Hiroyuki Shibuya / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin" / Made available in DSpace on 2018-07-27T17:24:45Z (GMT). No. of bitstreams: 1 Barroso_SergioLuizCarmelo_D.pdf: 2270709 bytes, checksum: fb11ff8df774dee844a6f4c2e3561d08 (MD5) Previous issue date: 2001 / Resumo: Ao longo de sua existência, a Colaboração Brasil Japão para o Experimento com Câmara de Emulsões de Chacaltaya tem colhido resultados importantes nas áreas da Física de Raios Cósmicos, Altas Energias e de Partículas. Um destes resultados é a observação das famílias atmosféricas conhecidas como eventos do tipo Centauro. Sua característica principal é a predominância da componente hadrônica entre os secundários observados e é esta característica que permite sua identificação. A identificação da componente hadrônicade uma família é feita usando-se certos critérios baseados em características observáveis. Apesar de sua fundamentação teórica, estes critérios são, por vezes, considerados subjetivos, o que coloca em dúvida a existência de famílias do tipo Centauro. Apresentamos neste trabalho uma análise que comprova a singularidade das famílias do tipo Centauro já identi.cadas, análise esta que não utiliza os critérios acima citados / Abstract: Along its existence, the Brasil-Japan Collaboration for the Chacaltaya Emulsion Chamber Experiment has obtained important results in the fields of Cosmic Rays, High Energy and Particle Physics. One of these results is the observation of the atmospheric families known as Centauro type events. Its main characteristic is the predominance of the hadronic component among the observed secondaries and it is this characteristic that allows its identification. The identification of the hadronic component of a family is made using some criterions based on observable characteristics. In spite of its theoretical basis, these criterions are, sometimes, considered subjective, what places in doubt the existence of Centauro families. We will present an analysis that is able to corroborate the singular nature of the families identified as Centauro. We will also show that this alternative analysis is able to accomplish this without using the criterions above / Doutorado / Física / Doutor em Ciências

Page generated in 0.1167 seconds