• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 140
  • Tagged with
  • 140
  • 140
  • 95
  • 90
  • 41
  • 37
  • 18
  • 18
  • 17
  • 16
  • 16
  • 14
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Reaproveitamento de águas e efluentes inorgânicos de uma indústria petroquímica

Pollo, Liliane Damaris January 2004 (has links)
A escassez de água, o alto custo do tratamento de efluentes e a iminente cobrança pelo uso e descarte da água vêm preocupando a sociedade e incentivando pesquisas na área de otimização do uso da água e minimização de efluentes. O setor industrial é um dos setores que mais tem se preocupado e se empenhado em encontrar soluções para este problema, pois vivencia os dois problemas ao mesmo tempo, a alta demanda de água e o tratamento dos efluentes gerados. É neste contexto que este trabalho se insere, através de um estudo de caso na Companhia Petroquímica do Sul (Copesul), mais especificamente no setor de utilidades. Neste estudo, foi feita uma análise dos principais processos envolvidos, desde a captação da água até seus consumidores finais, para a identificação da demanda de água e dos locais com maior potencial de reaproveitamento. Para tanto, foi necessária a realização de um balanço hídrico da unidade de tratamento de água usando combinações de dados de planta, estimativas e medições em campo, que foram ajustados através de reconciliação de dados. Os resultados obtidos para esta primeira etapa foram satisfatórios, obtendo uma redução do consumo de água estimada em 40 m3.h-1 e economia anual com o tratamento da água e efluentes de aproximadamente R$ 80.000,00. Também foram apresentadas duas propostas de configurações na planta para a aplicação destas alternativas de reaproveitamento. Numa segunda etapa, realizou-se um balanço de massa e energia para a torre de resfriamento, objetivando reduzir tanto o consumo de água de reposição como o descarte de efluente. O potencial de redução obtido na taxa volumétrica de purga do sistema, considerando apenas o efeito evaporativo e estado estacionário, foi estimado em 20 %. As iniciativas de reuso das águas de lavagem e enxágüe dos equipamentos, bem como da otimização do sistema de resfriamento, conduzem a uma redução da demanda de água e da geração de efluentes, trazendo benefícios econômicos e ambientais para a indústria.
32

Geração, caracterização e aplicações das nanobolhas na remoção de poluentes aquosos e reúso de água por flotação

Etchepare, Ramiro Gonçalves January 2016 (has links)
O objetivo desta tese de doutorado foi desenvolver um novo método de geração de nanobolhas de ar (NBs) em meio aquoso via cavitação hidrodinâmica. Foram estudados os principais parâmetros envolvidos na formação e propriedades das NBs, e foram estudadas aplicações na remoção de poluentes aquosos e no reúso de água por flotação. A geração de bolhas foi realizada e comparada utilizando duas técnicas: a primeira inclui a pressurização em vaso saturador e despressurização de água saturada com ar em uma válvula agulha (escala de bancada); e a segunda, por uma bomba multifásica (cisalhamento de ar em rotor aberto) e passagem forçada (despressurização) da mistura ar/líquido em uma válvula de agulha (sistema semi-contínuo). Com estas técnicas, tanto microbolhas (MBs, 30-100 μm) como NBs (150-250 nm) foram geradas em concentrações diferentes que dependem da pressão de saturação (Psat) e da tensão superficial do líquido. Para a caracterização das NBs, um procedimento de separação foi conduzido, explorando o fato de que as MBs ascendem e colapsam na superfície do líquido, enquanto que as NBs permanecem em suspensão durante longos períodos. A distribuição de tamanho e a concentração de NBs (número por volume) foram medidas pela técnica NTA (nanoparticle tracking analysis). Foi observado que a concentração de NBs formadas após a despressurização do fluxo de água saturada é função da quantidade de ar dissolvido na água e aumenta com o tempo de saturação até atingir o equilíbrio em 30 min de saturação. A concentração de NBs mostrou-se inversamente proporcional à Psat utilizada, e a maior concentração de NBs (1,5 x 109 NBs.mL-1) foi obtida com Psat de 2,5 bar e uma tensão superficial da solução de 50 mN.m-1, obtida com 100 mg.L-1 de α-Terpineol. Nos estudos em sistema semi-contínuo, a geração de MBs (D32 = 70 μm) e NBs (D32 = 150-300 nm) de ar foi realizada em um skid (sistema protótipo) tendo como principais componentes do sistema de geração de bolhas por cisalhamento do ar e cavitação hidrodinâmica, uma bomba multifásica, uma válvula agulha e uma coluna cilíndrica. Para a caracterização das NBs, o skid foi operado com a recirculação de um volume fixo de 40 L de água deionizada (DI) em uma vazão de líquido de 1000 L.h-1, razão gás/líquido de 7,5% (v/v) e temperatura controlada (21°C ± 1). Contrariamente ao método em nível de bancada de geração de NBs pela despressurização de água saturada (em vaso saturador), na geração contínua com o skid, maiores concentrações de NBs foram obtidas com o aumento da Psat pela ocorrência de mecanismos de cavitação hidrodinâmica adicionais (cisalhamento) aos do primeiro método. No skid, foi observado que as NBs de ar são resistentes ao cisalhamento ocasionado pelos rotores da bomba e às altas pressões de operação (até 5 bar) ao longo dos ciclos de geração de bolhas. O tamanho médio das NBs permanece constante e a sua concentração aumenta em função destes ciclos, atingindo um valor máximo após 29 ciclos, dependente da Psat e da tensão superficial da solução. As maiores concentrações de NBs (4 x 109 NBs.mL-1) foram obtidas com o aumento da pressão (5 bar) e com a diminuição da tensão superficial (50 mN.m-1). Esses fenômenos podem ser explicados pela lei de Henry e pela menor energia requerida para formação de bolhas quando a tensão interfacial ar/líquido for menor e maior for a diferença de pressão da fase líquida com relação à pressão atmosférica. O diâmetro médio e concentração destas NBs não variaram significativamente em um período de 2 meses, o que demonstrou a alta estabilidade destas NBs em concentrações elevadas. Ainda, quando a bomba multifásica foi operada sem injeção de ar, foi observado o mesmo efeito de aumento de concentração de NBs em função do nº de ciclos de geração. Nestas condições, um aumento da velocidade de fluxo do líquido (de 67 para 127 m.h-1) e um aumento da turbulência na saída da válvula agulha potencializou a formação de cavidades e a formação de um maior número de NBs (até 70% maior). Com relação aos parâmetros de dispersão de ar, altos valores de holdup (percentagem em volume de ar no líquido) de ar e fluxo de área superficial de bolhas (Sb), importantes para a flotação, foram obtidos (6,8% e 235 s-1, respectivamente) em uma pressão de operação de 4 bar. Foram realizados estudos de remoção de íons Fe+3, na forma de precipitados coloidais e nanopartículas de Fe(OH)3 (pH 7) por flotação com MBs e NBs e com NBs isoladas; em baixas pressões de saturação (concentração mais alta de NBs); e em altas pressões (onde a concentração de NBs é menor). A utilização de uma alta concentração de NBs juntamente com as MBs geradas na flotação em uma Psat de 2 bar, foi responsável por uma remoção de Fe(OH)3 superior a 99% (residual = 0,9 mg.L-1) e uma redução de turbidez de 95% (residual = 0,6 NTU). A flotação com uma Psat de 4 bar é mais rápida em função deste maior arraste de agregados por MBs (velocidade média de ascensão de bolhas/precipitados = 0,07 cm.s-1). Os resultados se explicam em termos do aprisionamento ou oclusão das NBs nos precipitados coloidais e do grau de aeração (demonstrado em microfotografias). Como resultado, diminui a densidade relativa destes precipitados, inferior à da água. Estudos de remoção, por flotação com MBs e NBs, de dispersões oleosas de petróleo (com 30 g.L-1 de NaCl) foram estudados após a floculação com 5 mg.L-1 de uma poliacrilamida catiônica (Dismulgan) em pH 7. A melhor remoção de óleo (>99% de eficiência) foi obtida com uma pressão de saturação de 5 bar, pela redução do teor de óleo (concentração inicial = 334–484 mg.L-1 mg/L) na água tratada a < 1 mg.L-1. Adicionalmente, a flotação utilizando uma pressão de 3,5 bar permitiu a obtenção de uma água tratada com teores de óleo inferiores a 29 mg.L-1, meta técnica deste estudo por ser o limite de emissão em plataformas de petróleo para descarte de água produzida em alto mar. A flotação foi bastante rápida e seguiu um modelo de primeira ordem, com constante cinética de flotação de 1,3 e 1,8 min-1 para as Psat de 3,5 e 5 bar, respectivamente. A injeção de NBs isoladas em conjunto com MBs residuais (condicionamento) após a etapa de floculação com 1 e 3 mg.L-1 de Dismulgan aumentou a hidrofobicidade dos agregados, facilitando a adesão entre bolhas e flocos oleosos, e aumentando a eficiência geral do processo de flotação de 73 para 84%, e de 92 para 95%, respectivamente. A flotação com NBs isoladas em conjunto com MBs residuais obteve eficiências de remoção de óleo de 75 e 90%, com e sem NaCl (30 g.L-1), respectivamente. Acredita-se que nestes casos, as NBs se aprisionam e aderem como “pancakes” nas gotículas de óleo floculadas, formando flocos oleosos aerados. O estudo aplicado de floculação-flotação com bomba multifásica para geração de bolhas, associado à ozonização (processo FFO), no tratamento de efluentes e reúso de água na lavagem de veículos demonstrou como principais resultados que a água de reúso era clarificada (turbidez = 10 NTU), sem odor (sulfeto < 1 mg.L-1), sem risco microbiológico (E. coli < 1,8 NMP.100.mL-1) e sem formação de espuma (surfactantes = 1,3 mg.L-1). Uma avaliação de custos mostrou que o período de amortização do equipamento FFO em sistemas de reciclagem de água na lavagem de veículos é dependente principalmente da tarifa da água e da demanda diária de lavagens, podendo ser inferior a 1 ano em municípios brasileiros. Os resultados obtidos nesta tese permitiram aprimorar e determinar as condições ótimas de técnicas de geração de elevadas concentrações de NBs, extremamente estáveis e demonstraram o elevado potencial destas bolhas para viabilizar diferentes rotas de tratamento e aplicações no tratamento de efluentes líquidos e reúso de água por flotação. / The main objective of this doctoral thesis was to develop a new method of generating air nanobubbles (NBs) in aqueous solutions by hydrodynamic cavitation. The main parameters involved in the formation and properties of NBs were assessed and applications were studied in the removal of aqueous pollutants models for water reuse by flotation. The generation of bubbles was carried out and compared using two techniques; i. Pressurization in a saturator vessel and depressurization of air-saturated water in a needle valve (bench level); and ii. Using a multiphase pump (air shearing in an open imeller) and depressurization of the ar/liquid mixture in a needle valve (semi-continuous system). By using these techniques, both microbubbles (MBs 30-100 uM) and NBs (150-200 nm) were generated in different concentrations as a function of the saturation pressure (Psat) and surface tension (liquid/air). For the characterization of NBs, a separation procedure was conducted exploiting the fact that the MBs rise and collapse at the liquid surface, while the NBs remain in suspension for long periods. The size distribution and concentration of NBs (number by volume) were measured by the NTA (nanoparticle tracking analysis) technique. It was found that the concentration of NBs formed after depressurizing the saturated water flow is a function of the amount of air dissolved in the water and increases with the saturation time achieving equilibrium after 30 min saturation. The concentration of NBs was inversely proportional to the Psat values, and more NBs (1.5 x 109 NBs.mL-1) were obtained at Psat - 2.5 bar and at a surface tension of 50 mN.m- 1, obtained with 100 mg.L-1 of α-Terpineol. In the semi-continuous system, the generation of MBs (D32 = 70 μm) and NBs (D32 = 150-300 nm) of air was performed with in a system called in this thesis as skid; with a multiphase pump, a needle valve and a cylindrical column as main components. For the characterization of NBs, the skid was operated with recirculation of a fixed volume of 40 L of deionized (DI) water at a liquid flow rate of 1000 L.h-1, at a gas / liquid ratio of 7.5% and controlled temperature (21°C ± 1). Contrary to the method at bench level, the NBs generation by the depressurization of air-saturated water (in saturator vessel), with the skid, higher concentrations of NBs were obtained increasing Psat due to the hydrodynamic cavitation mechanism (air shearing) in comparison with the first method. In the skid, it was observed that air NBs are resistant to shearing caused by pump impellers and to the high operating pressures (up to 5 bar) throughout the bubble generation cycles. The size of the NBs remained constant and its concentration increases as a function of these cycles, reaching a condition of equilibrium after 29 cycles; this was dependent on Psat and the surface tension of the solution. The highest concentrations of NBs (4 x 109 NBs.mL-1) were obtained with increasing pressure (5 bar) and reducing of surface tension of water (50 mN.m-1). These phenomena can be explained by the Henry's Law and the lower energy required for bubbles formation when the interfacial tension (air / liquid) is smaller and the higher is the difference between the Psat and the atmospheric pressure. The mean diameter and concentration of these NBs did not vary significantly over a period of two months, which demonstrated the high stability of these concentrated NBs. Furthermore, when the multiphase pump was operated without injecting air, it was observed the same effect of increasing concentration of NBs along the generation cycles. Thus, a greater fluid flow rate (from 67 to 127 m.h-1) and the increase of turbulence at the outlet of the valve needle potentiated the formation of cavities and the generation of a greater number of NBs (up to 70% higher). With respect to air dispersion parameters, high holdup (percentage by volume of air in the liquid) and superficial area flow density (Sb) values, important parameters for flotation, were obtained (6.8% and 235 s -1, respectively) at a 4 bar operating pressure. Studies on the removal of Fe+3 ions, as colloidal precipitates and Fe(OH)3 (pH 7) nanoparticles were carried out by flotation with MBs and NBs and with isolated NBs; at low saturation pressures (higher concentration of NBs); and at high pressures (where the concentration of NBs is lower). The use of a high concentration of NBs, together with MBs in a Psat of 2 bar generated along with the flotation, was responsible for a Fe(OH)3 removal of > 99% (residual = 0.9 mg.L-1), a turbidity reduction of 95% (residual = 0.6 NTU). The flotation with a Psat of 4 bar is faster due to this increased entrainment of aggregates by MBs (average rising velocity of the bubbles/precipitates = 0.07 cm.s-1). The flotation with isolated NBs (or “floatation” by NBs entrapment and reduction of the relative density of aggregates), was responsible for the removal of up to 91% of the total iron content, which resulted in a final concentration of 2.7 mg.L-1 (feed iron content =30 mg.L-1). The results are explained in terms of the entrapment or occlusion of NBs in the colloidal precipitates and higher aeration degree (shown in the photomicrographs). As a result, it decreases the relative density of these precipitates, lower than the water´s. The removal of oil dispersions (30 g.L-1 NaCl), by flotation with NBs and MBs, was carried out after flocculation with 5 mg.L-1 of a cationic polyacrylamide (Dismulgan) at pH 7. The best oil removal (> 99% efficiency) was obtained at 5 bar by reducing the oil content (feed concentration = 334-484 mg.L-1) in the treated water to < 1 mg.L-1. Furthermore, it was obtained a treated water with an oil content lower than 29 mg.L-1, which was a technical goal of this study (emission limit) for produced water discharge at offshore oil platforms, by using a Psat of 3.5 bar. The flotation was very fast and followed a first order model with a flotation rate constant of 1.3 and 1.8 min-1 for Psat values of 3.5 and 5 bar, respectively. The injection of isolated NBs in conjunction with residual MBs (conditioning stage) after flocculation with 1 and 3 mg L-1 Dismulgan increased the hydrophobicity of the aggregates, thus facilitating the adhesion between bubbles and oily flocs and increasing the overall efficiency of the flotation process from 73 to 84% and from 92 to 95%, respectively. The flotation with isolated NBs in conjunction with residual MBs resulted in oil removal efficiencies of 75 and 90% with and without NaCl (30 g.L-1), respectively. It is believed that in these cases the NBs entrap and adhere as "pancakes" into the flocculated oil droplets, forming aerated oily flocs. The applied study of flocculation-flotation with multiphase pump, associated with ozonation (FFO process) for wastewater treatment and water reuse in vehicle washing, demonstrated as main results the clarification of the reclaimed water (turbidity = 10 NTU), which was odorless (sulfide <1 mg.L-1) without any microbiological risk (E. coli <1.8 NMP.100.mL-1) and with no foaming (surfactant = 1.3 mg.L-1). A cost assessment showed that FFO equipment amortization period in vehicle washing water recycling systems is dependent mainly on water prices and on the daily washes demand, and it may be less than 1 year in Brazilian municipalities. The results obtained in this thesis allowed to improve and determine the optimal process conditions for the generation of high concentrations of extremely stable NBs, and demonstrated the high potential of these bubbles to enable different routes of treatment and applications in wastewater treatment and water reuse by flotation.
33

Eletrodiálise como tratamento terciário em uma estação de tratamento de efluentes de um Campus Universitário visando o reúso de água

Albornoz, Louidi Lauer January 2017 (has links)
A demanda atual por recursos hídricos com quantidade e qualidade exige que todos os efluentes domésticos sejam tratados de maneira adequada para minimizar os impactos ambientais causados no meio ambiente. As estações de tratamento de efluentes domésticos que utilizam sistemas tradicionais de tratamento em muitos casos não conseguem atingir os valores de remoção de poluentes exigidos pelas legislações ambientais e, portanto, processos avançados de tratamento de efluentes devem ser realizados para garantir tal atendimento. No presente trabalho foi realizada a coleta e caracterização físico-química de amostras em diferentes pontos de processo na estação de tratamento de efluentes do Campus Litoral Norte da Universidade Federal do Rio Grande do Sul. O monitoramento foi realizado durante 33 semanas e mostrou que o efluente tratado final da ETE apresentou valores elevados de poluentes como, por exemplo, nitrogênio total Kjeldahl (NTK), amônia e demanda química de oxigênio (DQO), o que impossibilita seu lançamento. O processo de eletrodiálise do efluente tratado da ETE foi realizada em uma planta piloto onde foram realizados 2 diferentes tipos de ensaios de eletrodiálise. No 1º ensaio o objetivo era avaliar o transporte iônico de poluentes do efluente após a eletrodiálise e os resultados encontrados mostram que, o efluente tratado por eletrodiálise, foram encontrados valores de concentração média abaixo de 1 mg/L para os ânions fluoreto, cloreto, nitrito e nitrato e para os cátions sódio, amônio, potássio e magnésio. Os resultados encontrados na caracterização fisico-química do efluente tratado indicam que o mesmo pode ser utilizado como água de reúso na agricultura, para fins urbanos e na psicicultura se for realizada a correção do pH. O 2º ensaio tinha como objetivo avaliar o comportamento das membranas através da qualidade do efluente após sucessivas eletrodiálises sem realizar a limpeza do sistema e os resultados encontrados mostram que foram obtidos valores de concentração média abaixo de 10 mg/L para todos os ânions e cátions. Os resultados encontrados pela caracterização fisico-química deste efluente tratado por eletrodiálise indicam que o mesmo pode ser utilizado como água de reúso na agricultura e reúso para fins urbanos se for realizada a correção do pH e a remoção da turbidez do efluente. Para o reúso na psicicultura, além da correção do pH, deve ser realizada a remoção do ânion nitrato para valores inferiores a 5 mg/L. / The current demand for water resources with quantity and quality requires that all domestic effluents must be adequately treated to minimize the environmental impacts caused on the environment. Municipal sewage treatment plants (MSTP) using traditional process in many cases fail to achieve the pollutant removal required by environmental. Therefore, advanced wastewater treatment processes must be carried out to ensure such care. The present work carried out the sampling and characterization samples at different process points from the wastewater treatment plant (WWTP) of Campus Litoral Norte of the Universidade Federal do Rio Grande do Sul. The monitoring was performed during 33 weeks and showed that the final treated effluent of the WWTP showed high values of pollutants such as NTK, ammonia and COD, which makes it impossible to discharge in nature. The process of electrodialysis of the final effluent, after the treatment at the WWTP, was carried out in the pilot plant. Two different electrodialysis tests were carried out. On the first test, the objective was to evaluate the ionic transport of pollutants from the effluent after the electrodialysis and the results found show that the effluent treated were found values of average concentration below 1 mg / L were obtained for fluoride, chloride, nitrite and nitrate anions and for sodium, ammonium, potassium and magnesium cations. The results found by the physicochemical characterization of the effluent indicate that it can be used as reuse water in agriculture, for urban proposes and in pisciculture if the pH correction is performed. In the second test, the objective was to evaluate the behavior of the membranes through the quality of the effluent after successive electrodialysis without cleaning the system. The results obtained in the effluent after the second test showed that mean values below 10 mg/L were obtained for all anions and cations. The results obtained by the physicochemical characterization of the effluent indicates that it can be used as reuse water in agriculture and for urban proposes reuse if the correction of the pH and the removal of the turbidity of the effluent is carried out. For reuse in the pisciculture, besides the correction of the pH, the removal of the nitrate anion should be carried out to values below 5 mg/L.
34

Integração de processos no tratamento de efluentes de lavagem de veículos para reciclagem de água

Etchepare, Ramiro Gonçalves January 2012 (has links)
Foram estudados processos integrados para o tratamento e reciclagem de água de um lava rápido comercial (LRC) e de efluentes de um posto de manutenção de locomotivas (PML), em nível de bancada e piloto. Os processos envolvidos foram a floculação-flotação em coluna, seguida de filtração em areia (FFC-A) e polimento com hipoclorito de sódio e adsorção em carvão ativado. A caracterização dos efluentes do LRC, com amostras coletadas afluentes de um separador (caixa) água-óleo – SAO, analisou concentrações médias de surfactantes de 20 mg.L-1 (dez vezes superiores ao limite de emissão local – 2 mg.L-1), baixas tensões superficiais (33 mN.m-1), cargas orgânicas moderadas (DQO = 239 mg.L-1 e DBO = 104 mg.L-1) e concentrações de coliformes totais de 2,4E+06 N.M.P.100mL-1 e de E. coli de 5,2E+02 N.M.P.100mL-1. O estudo de reciclagem de água no LRC foi dividido em duas campanhas. Na Campanha 1, com o processo FFC-A, a água de reúso apresentou uma alta clarificação (turbidez = 8 NTU). Entretanto, os resultados mostraram uma tendência de aumento tanto da concentração da DBO como da condutividade do efluente em função dos ciclos de água. Foi verificada ainda, uma alta concentração de coliformes totais e de E. coli no efluente, que foram causadores, entre outros fatores, de maus odores na pista de lavagem. Na Campanha 2, com a inclusão de uma cloração final (hipoclorito de sódio) ao tratamento proposto (FFC-AC), os coliformes totais e E. coli foram reduzidos em 92 e 96%, respectivamente, e além da elevada clarificação na água de reúso (turbidez média de 10 NTU), os odores não foram perceptíveis. Ao longo de todo o estudo no LRC, um percentual de reciclagem de água próximo a 70% foi alcançado, com mais de 2800 carros lavados usando um volume médio de 130 L por veículo. As principais vantagens do sistema incluíram a redução de emissão de efluentes na rede de drenagem pluvial e do consumo de água potável, utilizada apenas no enxágue final dos veículos como água de makeup. O risco microbiológico do efluente e da água de reúso do LRC foi estimado com a utilização de um modelo do tipo beta-Poisson e o micro-organismo E. coli como agente etiológico. Os resultados mostraram que, em um cenário de exposição dos usuários (clientes) do LRC, o risco foi sempre baixo. Entretanto, esse risco foi relativamente alto (1,0E-01, no caso do efluente e 3,7E-03, para a água de reúso) para os operadores. Um limite de 200 N.M.P.100 mL-1 de E. coli na água de reúso foi proposto para que o risco aos operadores seja aceitável (10-3) e uma dosagem de hipoclorito de sódio em concentrações entre 15 e 20 mgCl2.L-1 (obtida em estudos de bancada) foi sugerida para atingir este nível de desinfecção. A partir deste aprimoramento da dosagem de cloro e testes de jarros em laboratório com diferentes reagentes (polímero base tanino – PBT e cloreto de polialuminio – PAC), foi aplicado um balanço de massa para estimar as concentrações de parâmetros de qualidade na água de reúso com o aumento do número de ciclos de água. Os resultados indicaram que, para 70% de reciclagem de água, as concentrações de SDT e de íons cloreto estabilizaram a partir do 40° ciclo para os dois reagentes avaliados e foram menores que os valores limites de referência da literatura (SDT = 1000 mg.L-1 e íons cloreto = 400 mg.L-1), sugerindo um baixo potencial corrosivo desta água tratada. Uma pré-avaliação econômica operacional do sistema de reciclagem de água mostrou que o payback do equipamento FFC-A poderia ocorrer em um tempo próximo de 62 meses. Com relação aos estudos realizados no PML, foram observadas as seguintes características do efluente: pH alcalino, baixa biodegradabilidade, elevada carga orgânica (DQO = 1608 mg.L-1 e DBO = 525 mg.L-1) e de surfactantes (17 mg.L-1) e a presença de micro-organismos fecais (E. coli = 2,4E+05 NMP.100mL-1). O efluente não atendeu aos padrões de emissão local dos parâmetros pH, DBO, DQO, SST, óleos e graxas, surfactantes, sulfetos e fósforo, o que mostra um alto potencial poluidor aos corpos receptores. O tratamento proposto em nível piloto, com etapas de equalização, coagulação e processo FFC-A, foi altamente eficiente na remoção/redução dos parâmetros: turbidez (97%), SST (91%), DQO (76%), DBO (70%), fósforo (80%), nitrogênio (57%), sulfeto (76%) e óleos e graxas (51%). Com exceção a DQO, DBO e surfactantes, os demais parâmetros de qualidade monitorados foram enquadrados nos limites de emissão, sendo que um polimento com carvão ativado (3 kg.m-3, pH 7 e tr = 30 min), em nível de bancada, possibilitaria o enquadramento de todos os parâmetros analisados do efluente final aos limites de emissão locais (Resolução Consema n.° 128/2006). Os estudos de cloração com hipoclorito de sódio em laboratório indicaram uma dosagem de cloro muito elevada (200 mg.L-1) para assegurar uma desinfecção efetiva do efluente tratado no PML. Acredita-se que o presente trabalho contribuiu para o embasamento técnico de processos e para a definição de parâmetros específicos de qualidade de água de reúso na lavagem de veículos, contribuindo para a elaboração de leis com parâmetros de controle de qualidade e propiciando informação técnica aos setores acadêmicos e produtivos. / This work presents studies integrating processes for the wastewater treatment and water reuse in a commercial car wash (CCW) and locomotives maintenance station (LMC), at bench and pilot scales. The processes consisted of a flocculation column-flotation, followed by sand filtration (FCF-S) and polishing with sodium hypochlorite and/or adsorption on activated carbon. The characterization of the wastewater of the CCW, with samples collected after an oil-water separator device (API) showed mean concentrations values of surfactants of about 20 mg.L-1 (ten times higher than the local emission limit – 2 mg.L-1), low surface tension (33 mN.m-1), moderate organic load (DQO = 239 mg.L-1 e DBO = 104 mg.L-1) and high concentrations of total coliforms (2,4E+06 N.M.P.100mL-1) and E. coli (5,2E+02 N.M.P.100mL-1). The application of water recycling at the CCW was divided into two distinct campaigns. Campaign 1, with the FCF-S process, yielded a reclaimed water with high clarification (turbidity = 8 NTU). Yet, results showed a trend of buildup both in the concentration of BOD and conductivity of the feed wastewater as a function of water cycles. It was also observed a high concentration of total coliforms and E. coli in the wastewater, which were the cause, among other factors, of odors at the car wash pit. In Campaign 2, with the inclusion of a final chlorination (FCF-SC), the total coliforms and E. coli were reduced by 92 and 96%, respectively (2 log removal), in addition to the high clarification of the reclaimed water (average turbidity of 10 NTU), the odors were not noticeable. During the whole study at the LRC, a percentage of water recycling close to 70% was reached for more than 2700 cars washed with an average volume of 130 L per vehicle. The main advantages of the system included the reduction of both: wastewater emission in the storm water drainage network (there was no discharge during both campaigns) and consumption of fresh water, used only in the final rinse of the vehicles as makeup water. The microbiological risk of wastewater and reclaimed water of the CCW was estimated using a beta-Poisson model and the microorganism E. coli as the etiological agent. The results showed that in an exposure scenario of users (customers) of the CCW, the risk was always low. However, these risks were relatively high (10-3 in the case of the wastewater and 10-3 for the reclaimed water) for the operators. Thus, a limit of 200 CFU.100mL-1 of E. coli in the reclaimed water has been proposed so that the risk is acceptable to the operators (10-3) and a dose of sodium hypochlorite at concentrations between 15 and 20 mgCl2.L-1 (obtained in bench-studies) was suggested to reach this level of disinfection. After determining chlorine dosage and after jar-tests at laboratory with different reagents (tannin based polymer - TBP and polyaluminium chloride - PAC), it was applied a mass balance to estimate the concentrations of water quality parameters in the reclaimed water with increasing water cycles. The results indicated that, by fixing the percentage of water recycling at 70%, the TDS and chloride concentrations stabilized after 40 water cycles for the two evaluated reagents and these values were lower than literature reference limits (TDS = 1000 mg.L-1 and chloride = 400 mg.L-1), suggesting a low corrosion potential of this treated water. A preliminary economic-operational assessment of the proposed water recycling system showed that the payback of the FCF-S equipment could occur within a period of time close to 62 months. Regarding the studies at the LMS, the following characteristics of the wastewater were observed: alkaline pH, low biodegradability, high organic load (COD = 1608 mg.L-1 and BOD = 525 mg.L-1);17 mg.L- 1 surfactants concentration and the presence of coliform organisms (E. coli = 2,4E+05 NMP.100mL-1). Thus, the wastewater did not meet the local emission limits of the parameters pH, BOD, COD, TSS, oil and grease, surfactants, phosphorus and sulfide, which shows a high pollution potential for the receiving water bodies. The treatment conducted at pilot-scale, with stages of equalization, coagulation and FCF-S process resulted in a high efficiency for the removal/reduction of the parameters: turbidity (97%), TSS (91%), COD (76%), BOD (70 %), phosphorus (80%), nitrogen (57%), sulfide (76%) and oil and grease (51%). With the exception of COD, BOD and surfactants, other monitored parameters were below the standard emission limits, and a polishing stage with activated carbon (3 kg.m-3, pH 7 and 30 min of contact), at bench level, would allow a discharging water having those parameters meeting the local environmental standards. The breakpoint chlorination studies in laboratory indicated a very high dosage of chlorine (200 mg.L-1) to ensure effective disinfection of the treated wastewater in the LMS. This work contributed for technical advances of processes assisting the specification of the quality parameters in reclaimed water for washing vehicles; contribute for the development of legislation on quality control parameters (especially those related to microbiological risks) and provides technical information for the academic and industrial sectors.
35

Estudo para proposta de critérios de qualidade da água para reúso urbano. / Proposal of guidelines to water quality for urban reuse.

Vanessa Dias da Cunha 01 October 2008 (has links)
A cada dia a disputa pelo uso da água entre os diversos setores aumenta gerando sérios conflitos entre os usuários. Para minimizar a crise da água, tem-se desenvolvido técnicas, estudos, projetos e medidas que visem a proteção e conservação dos recursos disponíveis. Neste contexto, a possibilidade de substituição de parte da água potável, para usos menos restritivos, por uma de qualidade inferior está cada vez mais em evidência. No entanto, a falta de regulamentação específica sobre o assunto pode trazer conseqüências indesejáveis como riscos à saúde pública e ao meio ambiente, criação de práticas inadequadas; conflitos de competências e de interesses e, até, o descrédito da prática do reúso de água por parte da população. Este trabalho visa propor as variáveis de qualidade e seus respectivos limites para água de reúso urbano não potável de modo a garantir que esta prática seja viável e segura. Para tanto, são apresentados os potenciais usos urbanos da água de reúso e os riscos associados; as experiências internacionais e nacionais dos programas de reúso; a legislação e diretrizes existentes. Com base na pesquisa concluiu-se que a qualidade da água está relacionada aos perigos do reúso de água, contaminação química e contaminação microbiológica, sendo esta a mais relevante. Desta forma, definiu-se como variáveis de controle: os coliformes termotolerantes que indicam a contaminação por microorganismos patogênicos; de sólidos dissolvidos totais que causam danos materiais como incrustação e corrosão; da matéria orgânica que pode causar o ressurgimento dos microorganismos e aumentar o consumo do agente de desinfecção; da turbidez que interfere no processo da desinfecção; do cloro residual que deverá garantir a eliminação dos organismos patogênicos e garantir um residual para evitar o ressurgimento de bactérias. / Every day the dispute for the use of water between the sectors increases creating serious conflicts between the users. To minimize the water crisis, several options have been looked for through development of techniques, studies, projects and measures that seek the protection and conservation of the available resources. In this context, the possibility of replacing part of the potable water for one of lower quality is more and more in evidence. However, the lack of specific regulation on the issue can bring undesirable consequences as risk to public health and to the environment; creation of inadequate practices; conflicts of competences and of interests; and mainly the precipitate condemnation of water reuse from part of the population. This paper aims to propose the variables and quality of their water limits for urban non-potable reuse in order to ensure that this practice is feasible and safe. For that, are presented the potential uses of reuse water and the associate risks; the national and international experiences of reuse programs; the existing legislation and guidelines; and proposed quality criteria for the reuse water seeking a safe practice. Each one of these items will be evaluated and then the quality criteria will be proposed as well as their concentration for urban reuse. Based on the research concluded that water quality is related to the dangers of reuse of water contamination, chemical and microbiological contamination, which is the more relevant. Thus, it was defined as control variables of the limits of the thermotolerant coliforms that indicate the contamination by pathogenic microorganisms; of total dissolved solids that cause incrustation and corrosion problems; of organic matter that can cause the resurgence of the microorganisms; of the turbidity that interferes in the disinfection process; of the residual chlorine that must guarantee the elimination of pathogenic organisms.
36

Reúso de água em indústria metalúrgica rolamenteira - estudo de caso da SKF do Brasil Ltda. / Reuse of water in bearing industry - case study of SKF of Brazil Ltda.

Romário Maron Júnior 25 April 2006 (has links)
Com a globalização do mercado, muitas empresas procuraram se modernizar objetivando tornarem-se mais competitivas, com o crescimento industrial os recursos naturais apresentam-se mais escassos levando ao desenvolvimento de leis ambientais cada vez mais rígidas. Os custos envolvidos com o uso dos recursos naturais, têm levado as indústrias a buscarem alternativas a curto e médio prazos para minimizarem estes custos, procurando reduzir os seus impactos ambientais. A busca para um menor consumo de água através de técnicas de reúso e reciclagem nos processos industriais passam a fazer parte do planejamento estratégico de várias empresas, inclusive das rolamenteiras. O presente trabalho foi desenvolvido com o objetivo de avaliar o potencial de reúso da água da atividade de tamboreamento de rolos cônicos com espessura entre 5 a 8 mm e altura de 6 a 8 mm, sendo uma atividade de suma importância para garantir um padrão de qualidade satisfatório, de forma que as atividades subsequentes sejam efetuadas sem anomalias técnicas, conduzindo à obtenção de um produto final de qualidade. Por não requerer uma água com padrões elevados de qualidade, neste trabalho foi demonstrado o potencial de reúso de efluentes na atividade de tamboreamento, viabilizando-se sobre maneira o objeto deste estudo, onde é possível avaliar os aspectos físicos e químicos antes e após o tratamento da água para futura implantação contínua. / With the globalization of the market, many companies had looked for to be modernized for becoming more competitive. With the industrial growth, natural resources scarcity, and environmental pollution result in the development of more stringent laws. The costs associated with the use of the natural resources are taking the industries to search alternatives of short and long terms to minimize these costs looking for the reduction of its environmental impacts. The searching for reduced water consumption through techniques of reuse and recycling in its processes start to be integrated in the strategic planning of some companies including the bearing industry. The present work has been developed with the objective of evaluating the potential of water reuse in the activity of tumbling conical coils with thickness in the range of 5 to 8 mm, and height of 6 to 8 mm, being an activity of utmost importance to guarantee a satisfactory quality standard, in order that the subsequent activities are effected without anomalies, leading to the attainment of an end product of quality. By not requiring water with high standards of quality, in this work the potential of effluent reuse was demonstrated in the activity of tumbling, making possible to achieve the objective of this study, where it was possible to evaluate water physical and chemical aspects before and after the treatment for future implantation in continue way.
37

Banhados construídos como sistema terciário para reúso da água industrial em uma empresa metal-mecânica

Curia, Ana Cristina January 2010 (has links)
Com a poluição dos recursos hídricos e o substancial aumento do custo com água, o reúso da água tornou-se uma alternativa a ser considerada nas operações industriais. Essa iniciativa pode auxiliar na busca de uma solução para problemas de escassez de recursos hídricos e na diminuição de custos operacionais das empresas. O problema a ser abordado neste estudo está relacionado com as dificuldades técnicas do tratamento de efluentes para atingir a qualidade necessária ao reúso da água e a necessidade de atender os padrões de lançamento de efluentes estabelecidos pela legislação ambiental tendo em vista a impossibilidade de reúso total do efluente tratado. O principal objetivo deste trabalho foi estudar a remoção de poluentes gerados em uma indústria metal-mecânica por meio de plantas aquáticas em escala piloto e industrial e avaliar o potencial de reúso do efluente como água industrial em diferentes aplicações (descarga de vaso sanitário, irrigação paisagística, torre de resfriamento, lavagem de equipamentos, usinagem de peças e água de incêndio). Para este estudo foram projetadas e construídas uma planta piloto e outra planta em escala industrial em uma empresa situada na região metropolitana de Porto Alegre. O sistema foi constituído por um banhado construído como sistema terciário para simular as condições de tratamento do efluente industrial. As macrófitas foram acondicionadas em tanques de polietileno com capacidade total de 1 m3 considerando o tratamento de efluente de 2 m3/dia. O efluente circulou com um fluxo sub-superficial horizontal através da matriz porosa de areia grossa e brita, na quais estavam presentes as raízes das macrófitas das espécies Junco (Scirpus sp.) e Taboa (Typha sp.). A planta em escala industrial foi executada seguindo os mesmos padrões da planta piloto, porém, com algumas modificações. A planta industrial é constituída de 4 lagoas de fluxo sub-superficial horizontal com dimensões idênticas de 11,50 m de largura, 7,0 m de comprimento e 0,8 m de profundidade útil; camada suporte composta de brita zero; construção das lagoas com argila compactada; uso das espécies Junco (Scirpus sp.) e Taboa (Typha sp.) nas quatros lagoas de forma intercalada; estação de bombeamento e rede para o reúso do efluente tratado. O estudo de tratabilidade da planta em escala piloto e industrial foi realizado por monitoramento dos parâmetros físico-químicos e biológicos. Mesmo com algumas variações de carga e problemas operacionais, o sistema apresentou um comportamento adequado para a remoção de poluentes na planta piloto/ industrial, cujos resultados médios de eficiência de remoção foram de 73%/49%, 61%/42%, 56%/46%, 54%/49%, 57%/46% e 66%/69% de fósforo total, NTK, NH4-N, DQO, DBO, SS, respectivamente. As análises da camada suporte em conjunto com o sistema radicular e parte aérea apontam um possível potencial de emprego destes resíduos no solo como adubo devido a sua composição. O sistema de tratamento com banhado construído para reúso da água mostrou ser efetivo para redução de custos cujo período de payback médio é de 4,5 anos. Durante o experimento foi possível verificar que o reúso de água consiste em uma estratégia de sustentabilidade para redução do consumo de água potável (economia de 18 % em média e 44% máxima do consumo total). / With the pollution of water resources and the substantial increase in the cost of water, water reuse has become an alternative to be considered in industrial operations. This initiative can support in finding a solution to problems of scarcity water resources and minimizing operating costs in the companies. The problem to be considering in this study is related to the technical difficulties of treating effluent to aiming the quality necessary for water reuse and the need to reach effluent discharge standards set by environmental legislation considering the impossibility of total effluent treated reuse. The objective of this work was to study the pollutants removal generated in a metalworking industry effluent by aquatic plants in pilot and industrial scales and evaluate the potential for effluent reuse as industrial water in different applications (flushing, landscape irrigation, cooling tower, vehicles washing, machining of parts and firefighting). A pilot plant was built in an industry consisting of a constructed wetland as a tertiary system to simulate the conditions of treatment of an industrial effluent. The macrophytes were conditioned in polyethylene tanks with a total capacity of 1 m3 foreseeing the treatment of 2 m3/day. The effluent circulated in a horizontal subsurface flow through a porous matrix of thick sand and gravel in which the roots of macrophytes of the species Reed (Scirpus sp.) and Cattail (Typha sp.) were developed. The industrial scale plant was executed following the same standards by the pilot plant with some modifications. The industrial plant was composed by four horizontal sub-surface flow lagoons with equal dimensions of 11m width, 7m length and 0.8m useful depth; a support layer composed by gravel; lagoons with compacted clay; Reed (Scirpus sp.) and Cattail (Typha sp.) aquatic plant were interchangeably introduced in the four lagoons; pump station and network of pipes for the reuse of the treated effluent. The study of the treatment was carried out by monitoring of the physical-chemical and biological parameters. Even though some operational load variations and operational problems, the system showed an adequate behavior for the removal of pollutants, in pilot and industrial scales whose the average removal efficiency results were 73%/49%, 61%/42%, 56%/46%, 54%/49%, 57%/46% e 66%/69%, respectively. The analyses of the support layer with the root system and aerial part of the plant pointed out a possible potential of use of these wastes in the ground as fertilizer due to its composition. The constructed wetland treatment system for reuse of water showed to be effective for reduction of costs and the payback is very attractive (4.5 years). During the experiment it was possible to verify that reuse of water is a useful sustainability strategy to reduction of utilization of drinking water in industrial operations (saving of 18 % in average and 44% maximum of total consumption).
38

Avaliação do processo de eletrodiálise reversa no tratamento de efluentes de refinaria de petróleo

Machado, Mara de Barros January 2008 (has links)
Este trabalho teve como objetivo avaliar a aplicação da eletrodiálise reversa no tratamento de efluente final de refinaria para reuso em sistema de resfriamento. O estudo foi conduzido nas instalações da Refinaria Gabriel Passos (REGAP)- MG, com efluente real, proveniente da saída da Estação de Tratamento de Despejos Industriais (E.T.D.I.), e utilizando para os testes uma unidade-piloto de eletrodiálise reversa com capacidade de tratamento de 2 m3/h. A utilização do processo de dessalinização por EDR teve o objetivo de reduzir sólidos totais dissolvidos no efluente de aproximadamente 1.240 mg/L para 310 mg/L, o que equivale a cloretos de 460 mg/L e 100 mg/L respectivamente, para atingir a qualidade requerida para água de make-up da torre de resfriamento da REGAP. Inicialmente foi feita uma avaliação comparativa com o processo de osmose inversa, no qual foi constatada, com o uso da EDR, a maior continuidade operacional, menores problemas de incrustação e menor exigência para o pré-tratamento do efluente. No estudo com a EDR foram realizados testes variando-se a vazão, de 600 a 2000 L/h de produto; voltagem de 200 a 370V e número de estágios. Durante os testes foi realizado o monitoramento operacional e analítico da água de alimentação da EDR, do produto (solução diluída) e do rejeito (concentrado salino), sendo os dados avaliados e correlacionados para determinação da densidade de corrente, taxa hidráulica, eficiência e taxa de remoção de sais. A análise da formação de incrustações e deposições na superfície das membranas levou ao estabelecimento de um procedimento de limpeza química. O estudo foi conduzido de forma a obter a otimização da operação com rendimento necessário na remoção de sólidos dissolvidos, menor custo energético e de manutenção. Após os testes foi selecionada a condição otimizada da unidade piloto: módulo em 2 estágios, vazão de 1,1 m3/h e voltagem de 275V. Para este condição o consumo energético foi de 1,95 KWh/m3 de efluente tratado. Os resultados mostraram a viabilidade técnica-econômica do uso da EDR para remoção de sais de efluente final de refinaria para aplicação em reposição de sistemas de resfriamento. / This study aimed the evaluation of the application of electrodialysis reversal in final effluent treatment targeting the reuse in cooling towers. The study was done in Gabriel Passos Refinery (REGAP) - MG, with real effluent, from the Industrial Effluent Treatment Station (ETDI), and was held in a pilot plant of electrodialysis reversal with a treatment capacity of 2 m3 / h. The use of the desalination process with EDR target the reduction of total dissolved solids in the effluent of about 1.240 mg / L to 310 mg / L, equivalent to chlorides of 460 mg / L and 100 mg / L respectively, to reach the required quality of make-up water in the REGAP cooling tower. It was originally done a comparative evaluation with reverse osmosis process, another method of membrane desalination. Electrodialysis was selected because of its operating stability, less problems with scaling and fouling, dispensing the use of conditioning chemicals, and the requirement of a simpler pre- treatment The tests with EDR were carried out ranging the product flux for 600 to 2.000 L/h, the voltage for 200 to 370V and the number of hydraulic stages. During the tests were analyzed operational and analytical data in the EDR feed, product (diluted solution) and reject (concentrated solution), being the parameters analyzed and correlated to determine the current density, hydraulic rate, efficiency and salts removal rate. The analysis of fouling and deposition formation on the membranes surface led to an establishment of a chemical cleaning procedure. This study was conducted in order to obtain the operational optimizing with the necessary income to remove dissolved solids, with lower energy cost and maintenance. After the tests was selected the optimum condition for the pilot plant: stack in 2 stages, flow rate of 1.1 m3/h and voltage of 275V. In this condition the power consumption was 1.95 KWh/m3 of treated effluent. The results showed the technical and economic feasibility for the EDR in removing salts from refinery effluents for reuse in make up of cooling systems.
39

Reaproveitamento de águas e efluentes inorgânicos de uma indústria petroquímica

Pollo, Liliane Damaris January 2004 (has links)
A escassez de água, o alto custo do tratamento de efluentes e a iminente cobrança pelo uso e descarte da água vêm preocupando a sociedade e incentivando pesquisas na área de otimização do uso da água e minimização de efluentes. O setor industrial é um dos setores que mais tem se preocupado e se empenhado em encontrar soluções para este problema, pois vivencia os dois problemas ao mesmo tempo, a alta demanda de água e o tratamento dos efluentes gerados. É neste contexto que este trabalho se insere, através de um estudo de caso na Companhia Petroquímica do Sul (Copesul), mais especificamente no setor de utilidades. Neste estudo, foi feita uma análise dos principais processos envolvidos, desde a captação da água até seus consumidores finais, para a identificação da demanda de água e dos locais com maior potencial de reaproveitamento. Para tanto, foi necessária a realização de um balanço hídrico da unidade de tratamento de água usando combinações de dados de planta, estimativas e medições em campo, que foram ajustados através de reconciliação de dados. Os resultados obtidos para esta primeira etapa foram satisfatórios, obtendo uma redução do consumo de água estimada em 40 m3.h-1 e economia anual com o tratamento da água e efluentes de aproximadamente R$ 80.000,00. Também foram apresentadas duas propostas de configurações na planta para a aplicação destas alternativas de reaproveitamento. Numa segunda etapa, realizou-se um balanço de massa e energia para a torre de resfriamento, objetivando reduzir tanto o consumo de água de reposição como o descarte de efluente. O potencial de redução obtido na taxa volumétrica de purga do sistema, considerando apenas o efeito evaporativo e estado estacionário, foi estimado em 20 %. As iniciativas de reuso das águas de lavagem e enxágüe dos equipamentos, bem como da otimização do sistema de resfriamento, conduzem a uma redução da demanda de água e da geração de efluentes, trazendo benefícios econômicos e ambientais para a indústria.
40

Integração de processos no tratamento de efluentes de lavagem de veículos para reciclagem de água

Etchepare, Ramiro Gonçalves January 2012 (has links)
Foram estudados processos integrados para o tratamento e reciclagem de água de um lava rápido comercial (LRC) e de efluentes de um posto de manutenção de locomotivas (PML), em nível de bancada e piloto. Os processos envolvidos foram a floculação-flotação em coluna, seguida de filtração em areia (FFC-A) e polimento com hipoclorito de sódio e adsorção em carvão ativado. A caracterização dos efluentes do LRC, com amostras coletadas afluentes de um separador (caixa) água-óleo – SAO, analisou concentrações médias de surfactantes de 20 mg.L-1 (dez vezes superiores ao limite de emissão local – 2 mg.L-1), baixas tensões superficiais (33 mN.m-1), cargas orgânicas moderadas (DQO = 239 mg.L-1 e DBO = 104 mg.L-1) e concentrações de coliformes totais de 2,4E+06 N.M.P.100mL-1 e de E. coli de 5,2E+02 N.M.P.100mL-1. O estudo de reciclagem de água no LRC foi dividido em duas campanhas. Na Campanha 1, com o processo FFC-A, a água de reúso apresentou uma alta clarificação (turbidez = 8 NTU). Entretanto, os resultados mostraram uma tendência de aumento tanto da concentração da DBO como da condutividade do efluente em função dos ciclos de água. Foi verificada ainda, uma alta concentração de coliformes totais e de E. coli no efluente, que foram causadores, entre outros fatores, de maus odores na pista de lavagem. Na Campanha 2, com a inclusão de uma cloração final (hipoclorito de sódio) ao tratamento proposto (FFC-AC), os coliformes totais e E. coli foram reduzidos em 92 e 96%, respectivamente, e além da elevada clarificação na água de reúso (turbidez média de 10 NTU), os odores não foram perceptíveis. Ao longo de todo o estudo no LRC, um percentual de reciclagem de água próximo a 70% foi alcançado, com mais de 2800 carros lavados usando um volume médio de 130 L por veículo. As principais vantagens do sistema incluíram a redução de emissão de efluentes na rede de drenagem pluvial e do consumo de água potável, utilizada apenas no enxágue final dos veículos como água de makeup. O risco microbiológico do efluente e da água de reúso do LRC foi estimado com a utilização de um modelo do tipo beta-Poisson e o micro-organismo E. coli como agente etiológico. Os resultados mostraram que, em um cenário de exposição dos usuários (clientes) do LRC, o risco foi sempre baixo. Entretanto, esse risco foi relativamente alto (1,0E-01, no caso do efluente e 3,7E-03, para a água de reúso) para os operadores. Um limite de 200 N.M.P.100 mL-1 de E. coli na água de reúso foi proposto para que o risco aos operadores seja aceitável (10-3) e uma dosagem de hipoclorito de sódio em concentrações entre 15 e 20 mgCl2.L-1 (obtida em estudos de bancada) foi sugerida para atingir este nível de desinfecção. A partir deste aprimoramento da dosagem de cloro e testes de jarros em laboratório com diferentes reagentes (polímero base tanino – PBT e cloreto de polialuminio – PAC), foi aplicado um balanço de massa para estimar as concentrações de parâmetros de qualidade na água de reúso com o aumento do número de ciclos de água. Os resultados indicaram que, para 70% de reciclagem de água, as concentrações de SDT e de íons cloreto estabilizaram a partir do 40° ciclo para os dois reagentes avaliados e foram menores que os valores limites de referência da literatura (SDT = 1000 mg.L-1 e íons cloreto = 400 mg.L-1), sugerindo um baixo potencial corrosivo desta água tratada. Uma pré-avaliação econômica operacional do sistema de reciclagem de água mostrou que o payback do equipamento FFC-A poderia ocorrer em um tempo próximo de 62 meses. Com relação aos estudos realizados no PML, foram observadas as seguintes características do efluente: pH alcalino, baixa biodegradabilidade, elevada carga orgânica (DQO = 1608 mg.L-1 e DBO = 525 mg.L-1) e de surfactantes (17 mg.L-1) e a presença de micro-organismos fecais (E. coli = 2,4E+05 NMP.100mL-1). O efluente não atendeu aos padrões de emissão local dos parâmetros pH, DBO, DQO, SST, óleos e graxas, surfactantes, sulfetos e fósforo, o que mostra um alto potencial poluidor aos corpos receptores. O tratamento proposto em nível piloto, com etapas de equalização, coagulação e processo FFC-A, foi altamente eficiente na remoção/redução dos parâmetros: turbidez (97%), SST (91%), DQO (76%), DBO (70%), fósforo (80%), nitrogênio (57%), sulfeto (76%) e óleos e graxas (51%). Com exceção a DQO, DBO e surfactantes, os demais parâmetros de qualidade monitorados foram enquadrados nos limites de emissão, sendo que um polimento com carvão ativado (3 kg.m-3, pH 7 e tr = 30 min), em nível de bancada, possibilitaria o enquadramento de todos os parâmetros analisados do efluente final aos limites de emissão locais (Resolução Consema n.° 128/2006). Os estudos de cloração com hipoclorito de sódio em laboratório indicaram uma dosagem de cloro muito elevada (200 mg.L-1) para assegurar uma desinfecção efetiva do efluente tratado no PML. Acredita-se que o presente trabalho contribuiu para o embasamento técnico de processos e para a definição de parâmetros específicos de qualidade de água de reúso na lavagem de veículos, contribuindo para a elaboração de leis com parâmetros de controle de qualidade e propiciando informação técnica aos setores acadêmicos e produtivos. / This work presents studies integrating processes for the wastewater treatment and water reuse in a commercial car wash (CCW) and locomotives maintenance station (LMC), at bench and pilot scales. The processes consisted of a flocculation column-flotation, followed by sand filtration (FCF-S) and polishing with sodium hypochlorite and/or adsorption on activated carbon. The characterization of the wastewater of the CCW, with samples collected after an oil-water separator device (API) showed mean concentrations values of surfactants of about 20 mg.L-1 (ten times higher than the local emission limit – 2 mg.L-1), low surface tension (33 mN.m-1), moderate organic load (DQO = 239 mg.L-1 e DBO = 104 mg.L-1) and high concentrations of total coliforms (2,4E+06 N.M.P.100mL-1) and E. coli (5,2E+02 N.M.P.100mL-1). The application of water recycling at the CCW was divided into two distinct campaigns. Campaign 1, with the FCF-S process, yielded a reclaimed water with high clarification (turbidity = 8 NTU). Yet, results showed a trend of buildup both in the concentration of BOD and conductivity of the feed wastewater as a function of water cycles. It was also observed a high concentration of total coliforms and E. coli in the wastewater, which were the cause, among other factors, of odors at the car wash pit. In Campaign 2, with the inclusion of a final chlorination (FCF-SC), the total coliforms and E. coli were reduced by 92 and 96%, respectively (2 log removal), in addition to the high clarification of the reclaimed water (average turbidity of 10 NTU), the odors were not noticeable. During the whole study at the LRC, a percentage of water recycling close to 70% was reached for more than 2700 cars washed with an average volume of 130 L per vehicle. The main advantages of the system included the reduction of both: wastewater emission in the storm water drainage network (there was no discharge during both campaigns) and consumption of fresh water, used only in the final rinse of the vehicles as makeup water. The microbiological risk of wastewater and reclaimed water of the CCW was estimated using a beta-Poisson model and the microorganism E. coli as the etiological agent. The results showed that in an exposure scenario of users (customers) of the CCW, the risk was always low. However, these risks were relatively high (10-3 in the case of the wastewater and 10-3 for the reclaimed water) for the operators. Thus, a limit of 200 CFU.100mL-1 of E. coli in the reclaimed water has been proposed so that the risk is acceptable to the operators (10-3) and a dose of sodium hypochlorite at concentrations between 15 and 20 mgCl2.L-1 (obtained in bench-studies) was suggested to reach this level of disinfection. After determining chlorine dosage and after jar-tests at laboratory with different reagents (tannin based polymer - TBP and polyaluminium chloride - PAC), it was applied a mass balance to estimate the concentrations of water quality parameters in the reclaimed water with increasing water cycles. The results indicated that, by fixing the percentage of water recycling at 70%, the TDS and chloride concentrations stabilized after 40 water cycles for the two evaluated reagents and these values were lower than literature reference limits (TDS = 1000 mg.L-1 and chloride = 400 mg.L-1), suggesting a low corrosion potential of this treated water. A preliminary economic-operational assessment of the proposed water recycling system showed that the payback of the FCF-S equipment could occur within a period of time close to 62 months. Regarding the studies at the LMS, the following characteristics of the wastewater were observed: alkaline pH, low biodegradability, high organic load (COD = 1608 mg.L-1 and BOD = 525 mg.L-1);17 mg.L- 1 surfactants concentration and the presence of coliform organisms (E. coli = 2,4E+05 NMP.100mL-1). Thus, the wastewater did not meet the local emission limits of the parameters pH, BOD, COD, TSS, oil and grease, surfactants, phosphorus and sulfide, which shows a high pollution potential for the receiving water bodies. The treatment conducted at pilot-scale, with stages of equalization, coagulation and FCF-S process resulted in a high efficiency for the removal/reduction of the parameters: turbidity (97%), TSS (91%), COD (76%), BOD (70 %), phosphorus (80%), nitrogen (57%), sulfide (76%) and oil and grease (51%). With the exception of COD, BOD and surfactants, other monitored parameters were below the standard emission limits, and a polishing stage with activated carbon (3 kg.m-3, pH 7 and 30 min of contact), at bench level, would allow a discharging water having those parameters meeting the local environmental standards. The breakpoint chlorination studies in laboratory indicated a very high dosage of chlorine (200 mg.L-1) to ensure effective disinfection of the treated wastewater in the LMS. This work contributed for technical advances of processes assisting the specification of the quality parameters in reclaimed water for washing vehicles; contribute for the development of legislation on quality control parameters (especially those related to microbiological risks) and provides technical information for the academic and industrial sectors.

Page generated in 0.1035 seconds