Spelling suggestions: "subject:"ceator dde feito expandido"" "subject:"ceator dde leite expandido""
1 |
Reator de leito expandido em escala plena com zonas anaeróbia e aeróbia sobrepostas: remoção conjunta de matéria orgânica e nutrientes e estudo do comportamento microbiológico do biofilme, por respirometria e microsensor de OD / Full scale expanded bed reactor with overlaid anaerobic and aerobic zones: joint removal of organic matter and nutrients and the study of microbiological biofilm behavior and DO microsensorSiman, Renato Ribeiro 15 June 2007 (has links)
A presente pesquisa teve a intenção de desenvolver reator biológico de 159 \'M POT.3\' de volume total, com leito de carvões granulares (ativado e antracito) expandido e parcialmente aerado, para promover remoções de matéria orgânica e nutrientes (N e P) do esgoto sanitário, devido a manutenção de ambientes anaeróbio e aeróbio, estratificados ao longo da altura do reator e ao longo do biofilme cultivado em seu interior. Para avaliar o impacto das modificações operacionais no comportamento biológico dos microrganismos presentes no reator, foram aplicados métodos para análise das atividades nitrificante (ANE), desnitrificante (ADE) e metanogênica (PME), embasados em testes respirométricos padrões descritos na literatura. A estratificação reacional também foi estudada dentro de filmes biológicos com a ajuda de microsensores amperométricos de OD em testes de bancada. Assim, após 451 dias de operação, foi possível verificar remoções médias de \'DQO IND.F\', NTK e fosfato total de, respectivamente 78%, 56% e 42%, quando o reator foi operado por 66 dias com tempo de detenção hidráulica médio de 8,8 h, injetor de oxigênio puro, instalado após placa de orifício em linha de recirculação aerada, a qual funcionava pressurizada (3 a 4 bar) e com razão média de recirculação igual a 3, comparada à vazão de alimentação. Para o restante do período, no qual foram aplicadas taxas de carregamentos volumétricos médios de 0,74 \'+ OU -\' 0,28 kg\'DQO IND.F\'/\'M POT.3\'.dia; 0,17 \'+ OU -\' 0,07 kg NTK/\'M POT.3\'.dia e 0,05 \'+ OU -\' 0,02 kg\'PO IND.4\'POT.-3\'/\'M POT.3\'.dia, o sistema demonstrou remoções médias de 65 \'+ OU -\' 20% para \'DQO IND.F\', 25 \'+ OU -\' 21% para o NTK e 48 \'+ OU -\' 18% para o fosfato total, mesmo operado com tempo de retenção celular médio de 15 \'+ OU -\' 7 dias. Os testes respirométricos foram sensíveis para avaliar a atividade microbiana do material biológico coletado ao longo do reator, com os quais foram verificados PME médio de 0,25 mL\'CH IND.4\'/gSVT.h, para as amostras de material biológico coletado na região anaeróbia, ao fundo do reator; ANE variando entre 1,3 a 4,4 mg\'O IND.2\'/gSVT.h, para as amostras coletadas na região aeróbia, intermediária ao reator; e ADE variando entre 0,024 e 5,20 mg\'N IND.2\'/gSVT.h, para amostras coletadas, respectivamente, no fundo e no topo do reator. As análises do material líquido também corroboram com a idéia de estratificação dos ambientes aeróbio, no fundo do reator, e micro-aerado, em sua região intermediária superior, apontando para região com alto potencial de ocorrerem nitrificação e desnitrificação conjuntas no topo da sua zona reativa. O microsensor amperométrico de OD com ponta entre 10 e 30 \'mü\'m de diâmetro, confeccionados em laboratório especializado, se mostrou sensível para a observação do gradiente de concentração de oxigênio dissolvido dentro de filme biológico, suficientes para a formação de regiões aeróbia e anaeróbia em seu interior, cuja informação pode ser útil para a aprimoramento de reatores com biofilme, projetados para remoções combinadas de matéria orgânica e nutrientes. Entretanto, quando se pretende definir parâmetros cinéticos ou de transferência de massa, maior rigor deve ser dispensado na definição dos locais para a aplicação do sensor, nos quais sejam reduzidos os efeitos da heterogeneidade do agregado microbiano no ajuste da modelagem matemática aplicada aos pontos experimentais / The current research aimed the development of a 159 \'M POT.3\' total volume biological reactor, with a expanded and partially aerated granular coal bed (activated and anthracite), to promote organic matter and nutrients (N and P) removal from wastewater due to the maintenance of anaerobic and aerobic environments, stratified throughout the height of the reactor and also all over the biofilm cultivated in its interior. Methods for the analyses of specific nitrifying activities (ENA), denitrifying (EDA) and methanogenic (EMA) were applied to assess the impact of the operational modifications in the biological behavior of microorganisms present in the reactor, based on standard respirometric tests found in literature. The reactional stratification was also studied inside the biological films with the help of DO microsensors in batch tests. Thus, after 451 of operation it was possible to verify mean \'COD IND.F\', TNK and phosphate removal of 78%, 56% and 42%, respectively, when the reactor was operated for 66 days with average hydraulic detention time of 8.8 h, pure oxygen injector which was installed after the aerated recirculation line which was working pressurized (3 to 4 bar) and with mean recirculation ratio equal to 3, when compared to the feeding flow. For the rest of the period where mean volumetric loading rates of 0.74 \'+ OR -\' 0.28 kg\'COD IND.F\'/\'M POT.3\'.day; 0.17 \'+ OR -\' 0.07 kgTNK/\'M POT.3\'.day and 0.05 \'+ OR -\' 0.02 kg\'PO IND.4\'POT.-3\'/\'M POT.3\'.day were applied the system demonstrated average removal of 65 \'+ OR -\' 20% for \'COD IND.F\', 25 \'+ OR -\' 21% for TNK and 48 \'+ OR -\' 18% for total phosphate, even when it operated with mean cellular retention time of 15 \'+ OR -\' 7 days. The respirometric tests were sensible enough to assess the microbial activity from the biological material collected throughout the reactor, and where mean PME of 0.25 mL\'CH IND.4\'/gSVT.h was verified for the samples of biological material collected in the anaerobic region, at the bottom of the reactor; ANE varying between 1.3 to 4.4 mg\'O IND.2\'/gSVT.h, for the samples collected in the aerobic region, reactor\'s intermediary; and ADE varying between 0.024 to 5.20 mg\'N IND.2\'/gSVT.h, for samples collected at the bottom and the top of the reactor, respectively. The analyses of the liquid material also support the idea of stratification of the aerobic environments, at the bottom of the reactor, and micro-aerated, in its superior intermediate region, pointing to the region as a high potential of occurring joint nitrification and denitrification at the top of the reactive zone. The DO amperometric microsensor, with tip between 10 and 30 \'mü\'m of diameter, produced in a special laboratory, is sensible to the determination of dissolved oxygen concentration gradient inside biological film, sufficient for the formation of anaerobic and aerobic regions in its interior, this information can be useful to the improvement of biofilm reactors, projected for the combined removal of organic matter and nutrients. However, when the definition of kinetic parameters or mass transference is intended more strictness must be applied when choosing the locals for microsensor application, where the effects of the microbial aggregate heterogeneity is reduced in the adjustment of the mathematical modeling applied to the experimental points.
|
2 |
Reator de leito expandido em escala plena com zonas anaeróbia e aeróbia sobrepostas: remoção conjunta de matéria orgânica e nutrientes e estudo do comportamento microbiológico do biofilme, por respirometria e microsensor de OD / Full scale expanded bed reactor with overlaid anaerobic and aerobic zones: joint removal of organic matter and nutrients and the study of microbiological biofilm behavior and DO microsensorRenato Ribeiro Siman 15 June 2007 (has links)
A presente pesquisa teve a intenção de desenvolver reator biológico de 159 \'M POT.3\' de volume total, com leito de carvões granulares (ativado e antracito) expandido e parcialmente aerado, para promover remoções de matéria orgânica e nutrientes (N e P) do esgoto sanitário, devido a manutenção de ambientes anaeróbio e aeróbio, estratificados ao longo da altura do reator e ao longo do biofilme cultivado em seu interior. Para avaliar o impacto das modificações operacionais no comportamento biológico dos microrganismos presentes no reator, foram aplicados métodos para análise das atividades nitrificante (ANE), desnitrificante (ADE) e metanogênica (PME), embasados em testes respirométricos padrões descritos na literatura. A estratificação reacional também foi estudada dentro de filmes biológicos com a ajuda de microsensores amperométricos de OD em testes de bancada. Assim, após 451 dias de operação, foi possível verificar remoções médias de \'DQO IND.F\', NTK e fosfato total de, respectivamente 78%, 56% e 42%, quando o reator foi operado por 66 dias com tempo de detenção hidráulica médio de 8,8 h, injetor de oxigênio puro, instalado após placa de orifício em linha de recirculação aerada, a qual funcionava pressurizada (3 a 4 bar) e com razão média de recirculação igual a 3, comparada à vazão de alimentação. Para o restante do período, no qual foram aplicadas taxas de carregamentos volumétricos médios de 0,74 \'+ OU -\' 0,28 kg\'DQO IND.F\'/\'M POT.3\'.dia; 0,17 \'+ OU -\' 0,07 kg NTK/\'M POT.3\'.dia e 0,05 \'+ OU -\' 0,02 kg\'PO IND.4\'POT.-3\'/\'M POT.3\'.dia, o sistema demonstrou remoções médias de 65 \'+ OU -\' 20% para \'DQO IND.F\', 25 \'+ OU -\' 21% para o NTK e 48 \'+ OU -\' 18% para o fosfato total, mesmo operado com tempo de retenção celular médio de 15 \'+ OU -\' 7 dias. Os testes respirométricos foram sensíveis para avaliar a atividade microbiana do material biológico coletado ao longo do reator, com os quais foram verificados PME médio de 0,25 mL\'CH IND.4\'/gSVT.h, para as amostras de material biológico coletado na região anaeróbia, ao fundo do reator; ANE variando entre 1,3 a 4,4 mg\'O IND.2\'/gSVT.h, para as amostras coletadas na região aeróbia, intermediária ao reator; e ADE variando entre 0,024 e 5,20 mg\'N IND.2\'/gSVT.h, para amostras coletadas, respectivamente, no fundo e no topo do reator. As análises do material líquido também corroboram com a idéia de estratificação dos ambientes aeróbio, no fundo do reator, e micro-aerado, em sua região intermediária superior, apontando para região com alto potencial de ocorrerem nitrificação e desnitrificação conjuntas no topo da sua zona reativa. O microsensor amperométrico de OD com ponta entre 10 e 30 \'mü\'m de diâmetro, confeccionados em laboratório especializado, se mostrou sensível para a observação do gradiente de concentração de oxigênio dissolvido dentro de filme biológico, suficientes para a formação de regiões aeróbia e anaeróbia em seu interior, cuja informação pode ser útil para a aprimoramento de reatores com biofilme, projetados para remoções combinadas de matéria orgânica e nutrientes. Entretanto, quando se pretende definir parâmetros cinéticos ou de transferência de massa, maior rigor deve ser dispensado na definição dos locais para a aplicação do sensor, nos quais sejam reduzidos os efeitos da heterogeneidade do agregado microbiano no ajuste da modelagem matemática aplicada aos pontos experimentais / The current research aimed the development of a 159 \'M POT.3\' total volume biological reactor, with a expanded and partially aerated granular coal bed (activated and anthracite), to promote organic matter and nutrients (N and P) removal from wastewater due to the maintenance of anaerobic and aerobic environments, stratified throughout the height of the reactor and also all over the biofilm cultivated in its interior. Methods for the analyses of specific nitrifying activities (ENA), denitrifying (EDA) and methanogenic (EMA) were applied to assess the impact of the operational modifications in the biological behavior of microorganisms present in the reactor, based on standard respirometric tests found in literature. The reactional stratification was also studied inside the biological films with the help of DO microsensors in batch tests. Thus, after 451 of operation it was possible to verify mean \'COD IND.F\', TNK and phosphate removal of 78%, 56% and 42%, respectively, when the reactor was operated for 66 days with average hydraulic detention time of 8.8 h, pure oxygen injector which was installed after the aerated recirculation line which was working pressurized (3 to 4 bar) and with mean recirculation ratio equal to 3, when compared to the feeding flow. For the rest of the period where mean volumetric loading rates of 0.74 \'+ OR -\' 0.28 kg\'COD IND.F\'/\'M POT.3\'.day; 0.17 \'+ OR -\' 0.07 kgTNK/\'M POT.3\'.day and 0.05 \'+ OR -\' 0.02 kg\'PO IND.4\'POT.-3\'/\'M POT.3\'.day were applied the system demonstrated average removal of 65 \'+ OR -\' 20% for \'COD IND.F\', 25 \'+ OR -\' 21% for TNK and 48 \'+ OR -\' 18% for total phosphate, even when it operated with mean cellular retention time of 15 \'+ OR -\' 7 days. The respirometric tests were sensible enough to assess the microbial activity from the biological material collected throughout the reactor, and where mean PME of 0.25 mL\'CH IND.4\'/gSVT.h was verified for the samples of biological material collected in the anaerobic region, at the bottom of the reactor; ANE varying between 1.3 to 4.4 mg\'O IND.2\'/gSVT.h, for the samples collected in the aerobic region, reactor\'s intermediary; and ADE varying between 0.024 to 5.20 mg\'N IND.2\'/gSVT.h, for samples collected at the bottom and the top of the reactor, respectively. The analyses of the liquid material also support the idea of stratification of the aerobic environments, at the bottom of the reactor, and micro-aerated, in its superior intermediate region, pointing to the region as a high potential of occurring joint nitrification and denitrification at the top of the reactive zone. The DO amperometric microsensor, with tip between 10 and 30 \'mü\'m of diameter, produced in a special laboratory, is sensible to the determination of dissolved oxygen concentration gradient inside biological film, sufficient for the formation of anaerobic and aerobic regions in its interior, this information can be useful to the improvement of biofilm reactors, projected for the combined removal of organic matter and nutrients. However, when the definition of kinetic parameters or mass transference is intended more strictness must be applied when choosing the locals for microsensor application, where the effects of the microbial aggregate heterogeneity is reduced in the adjustment of the mathematical modeling applied to the experimental points.
|
3 |
Tratamento de esgoto sanitário em um reator de leito expandido em escala plena, operado com regiões anaeróbia e aeróbia sobrepostas / Treatment of sanitary wastewater in a full scale expanded bed reactor, operated with overlap anaerobic and aerobic regionsRafael Ceribelli da Silva 26 June 2009 (has links)
A presente pesquisa teve como objetivo principal a avaliação do desempenho de um reator de leito expandido (159,0 \'M POT.3\'), em escala plena, operado sob condições anaeróbia e anaeróbia-aeróbia sobrepostas, tratando esgoto sanitário. Como objetivos específicos, foi avaliado o uso de areias comerciais para complementação do leito de partículas, bem como a distribuição do material suporte ao longo da altura do reator. Além disso, houve a simulação da flotação do efluente do sistema a fim de otimizar a eficiência na remoção de sólidos, visto pela ineficiência do sistema na separação dos sólidos biológicos. Dentre os materiais selecionados para compor o leito de partículas, foi escolhida a areia com tamanho médio dos grãos igual a 0,69 mm e massa específica de 2690 kg.\'M POT.-3\'. Esta pesquisa foi dividida em duas etapas experimentais, sendo que a primeira o sistema foi operado somente sob a condição anaeróbia, enquanto na segunda, o sistema foi submetido à condição anaeróbia e aeróbia sobrepostas. Para a primeira etapa, o sistema obteve maior eficiência na remoção de matéria orgânica, com TDH de 14 horas, quando foi removido 0,84 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 1,26 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQObruta, DQOfilt, DBObruta, DBOfilt, SST e SSV foram de 65%; 64%; 80%; 70%; 58% e 69%. O efluente apresentou, em média, 245 mgDQObruta/L, 117 mgDQOfilt/L, 104 mgDBObruta/L, 76 mgDBOfilt/L; 88 mgSST/L e 69 mgSSV/L. O grau de amonificação obtido foi de 90%, evidenciando a potenciabilidade do sistema na conversão de matéria nitrogenado orgânico em amoniacal. Para a segunda etapa, a maior eficiência na remoção de matéria orgânica foi obtida com TDH de 16 horas, quando foi removido 0,29 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 0,84 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQOfilt e DBOfiltr foram de 80% e 95%, respectivamente. O efluente apresentou, em média, 72 mgDQOfiltr/L, e 13 mgDBOfiltr/L. O grau de amonificação obtido foi de 85%, no entanto houve baixa eficiência na oxidação do \'N\'-amoniacal, no máximo 25%, sendo que as concentrações máximas no efluente foram de 4 mg\'N\'-\'NO IND.2\'POT.-\'/L e 2 mg\'NO IND.3\'POT.-\'/L, respectivamente. Em relação à distribuição do material suporte, foi verificada que a proporção de carvão ativado granular e carvão antracitoso foi superior em relação à areia, nos diferentes pontos de coleta, sendo que essa proporção tendeu a se reduzir ao longo das amostragens, além disso, foram verificadas que as características do fluxo não estão adequadas para proporcionar a fluidificação/expansão do leito de partículas. Os melhores resultados obtidos na simulação da flotação do efluente, quando foi aplicada recirculação com concentração de ar de 17,5 mgar/Lam, e velocidade ascensional de 10 cm/min. As eficiências de remoção de SST; SSF; SSV; DQO, cor e turbidez obtidas foram de 64; 82; 62; 62; 53 e 73%, respectivamente. O efluente flotado apresentou 63 mgSST/L; 5 mgSSF/L; 59 mgSSV/L; 127 mgDQObruta/L, 431 uC e 29 uT. / This present research had as main objective the evaluation of the performance of a full scale expanded bed reactor (159.0 \'M POT.3\'), operated under anaerobic and overlapping anaerobic-aerobic, treating sanitary wastewater. As specific objectives, it was evaluated using commercial sand to complement the bed of particles and distribution of material support along the height of reactor. Besides, it was simulated the flotation of the effluent system in order to optimize the efficient removal of solids, due to inefficiency of the system in the separation of biological solids. Among the materials selected to compose the bed of particles was chosen with the average size of sand grains equal to 0.69 mm and density of 2690 kg.\'M POT.-3\'. This research was divided into two experimental stages, the first being that the system was operated only under the anaerobic condition, while the second, the system was submited to anaerobic and aerobic conditions overlaped. For the first step, the system achieved greater efficiency in removing organic matter, with hydraulic detention time of 14 hours, when it was removed from 0.84 kgCODraw/\'M POT.3\'.day, which was applied 1.26 kgCOD/\'M POT.3\'.day. The mean removal efficiencies of DQOraw, DQOfiltered, BODraw, BODfiltered, TSS and VSS were 65%; 64%; 80%; 70%; 58% and 69%. The effluent had an average of 245 mgCODraw/L; 117 mgCODfiltered/L; 104 mgBODraw/L; 76 mgBODfiltered/L; 88 mgTSS/L and 69 mgVSS/L. The ammonification obtained was 90%, demonstrating the potencial of the system in the conversion of organic matter into ammonia nitrogen. For the second stage, the most efficient in the removal of organic matter was obtained with hydraulic detention time of 16 hours when it was removed from 0.29 kgCODraw/\'M POT.\'3.day, which was applied 0.84 kgCODraw/\'M POT.3\'.day. The mean removal efficiencies of CODfiltered and BODfiltered were 80% and 95%, respectively. The effluent had an average of 72 mgCODfiltered/L, and 13 mgBODfiltered/L. The ammonification obtained was 85%, however there was low efficiency in oxidation of ammonia-\'N\', at most 25%, and the maximum concentrations in the effluent were 4 mg\'N\'-\'NO IND.2\'POT.-\'/L and 2 mg\'N\'-\'NO IND.3\'POT.-\'/L, respectively. Regarding the distribution of material support, it was found that the proportion of activated granular carbon and anthracite carbon was higher on sand, in different points of collection, whereas this proportion tended to drop over the sample, moreover, was found that the characteristics of the flow are not adequate to provide fluidization/expansion of the bed of particles. The best results obtained in the simulation of the flotation of the effluent when it was applied with recirculation of air concentration of 17.5 mgair/Lsample, and ascension velocity of 10 cm/min. Removal efficiencies of TSS; FSS; VSS; COD, color and turbidity were obtained from 64; 82; 62; 62; 53 and 73%, respectively. The effluent had 63 mgTSS/L; 5 mgFSS/L; 59 mgVSS/L; 127 mgCODraw/L; 431 uC and 29 uT.
|
4 |
Tratamento de esgoto sanitário em um reator de leito expandido em escala plena, operado com regiões anaeróbia e aeróbia sobrepostas / Treatment of sanitary wastewater in a full scale expanded bed reactor, operated with overlap anaerobic and aerobic regionsSilva, Rafael Ceribelli da 26 June 2009 (has links)
A presente pesquisa teve como objetivo principal a avaliação do desempenho de um reator de leito expandido (159,0 \'M POT.3\'), em escala plena, operado sob condições anaeróbia e anaeróbia-aeróbia sobrepostas, tratando esgoto sanitário. Como objetivos específicos, foi avaliado o uso de areias comerciais para complementação do leito de partículas, bem como a distribuição do material suporte ao longo da altura do reator. Além disso, houve a simulação da flotação do efluente do sistema a fim de otimizar a eficiência na remoção de sólidos, visto pela ineficiência do sistema na separação dos sólidos biológicos. Dentre os materiais selecionados para compor o leito de partículas, foi escolhida a areia com tamanho médio dos grãos igual a 0,69 mm e massa específica de 2690 kg.\'M POT.-3\'. Esta pesquisa foi dividida em duas etapas experimentais, sendo que a primeira o sistema foi operado somente sob a condição anaeróbia, enquanto na segunda, o sistema foi submetido à condição anaeróbia e aeróbia sobrepostas. Para a primeira etapa, o sistema obteve maior eficiência na remoção de matéria orgânica, com TDH de 14 horas, quando foi removido 0,84 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 1,26 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQObruta, DQOfilt, DBObruta, DBOfilt, SST e SSV foram de 65%; 64%; 80%; 70%; 58% e 69%. O efluente apresentou, em média, 245 mgDQObruta/L, 117 mgDQOfilt/L, 104 mgDBObruta/L, 76 mgDBOfilt/L; 88 mgSST/L e 69 mgSSV/L. O grau de amonificação obtido foi de 90%, evidenciando a potenciabilidade do sistema na conversão de matéria nitrogenado orgânico em amoniacal. Para a segunda etapa, a maior eficiência na remoção de matéria orgânica foi obtida com TDH de 16 horas, quando foi removido 0,29 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 0,84 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQOfilt e DBOfiltr foram de 80% e 95%, respectivamente. O efluente apresentou, em média, 72 mgDQOfiltr/L, e 13 mgDBOfiltr/L. O grau de amonificação obtido foi de 85%, no entanto houve baixa eficiência na oxidação do \'N\'-amoniacal, no máximo 25%, sendo que as concentrações máximas no efluente foram de 4 mg\'N\'-\'NO IND.2\'POT.-\'/L e 2 mg\'NO IND.3\'POT.-\'/L, respectivamente. Em relação à distribuição do material suporte, foi verificada que a proporção de carvão ativado granular e carvão antracitoso foi superior em relação à areia, nos diferentes pontos de coleta, sendo que essa proporção tendeu a se reduzir ao longo das amostragens, além disso, foram verificadas que as características do fluxo não estão adequadas para proporcionar a fluidificação/expansão do leito de partículas. Os melhores resultados obtidos na simulação da flotação do efluente, quando foi aplicada recirculação com concentração de ar de 17,5 mgar/Lam, e velocidade ascensional de 10 cm/min. As eficiências de remoção de SST; SSF; SSV; DQO, cor e turbidez obtidas foram de 64; 82; 62; 62; 53 e 73%, respectivamente. O efluente flotado apresentou 63 mgSST/L; 5 mgSSF/L; 59 mgSSV/L; 127 mgDQObruta/L, 431 uC e 29 uT. / This present research had as main objective the evaluation of the performance of a full scale expanded bed reactor (159.0 \'M POT.3\'), operated under anaerobic and overlapping anaerobic-aerobic, treating sanitary wastewater. As specific objectives, it was evaluated using commercial sand to complement the bed of particles and distribution of material support along the height of reactor. Besides, it was simulated the flotation of the effluent system in order to optimize the efficient removal of solids, due to inefficiency of the system in the separation of biological solids. Among the materials selected to compose the bed of particles was chosen with the average size of sand grains equal to 0.69 mm and density of 2690 kg.\'M POT.-3\'. This research was divided into two experimental stages, the first being that the system was operated only under the anaerobic condition, while the second, the system was submited to anaerobic and aerobic conditions overlaped. For the first step, the system achieved greater efficiency in removing organic matter, with hydraulic detention time of 14 hours, when it was removed from 0.84 kgCODraw/\'M POT.3\'.day, which was applied 1.26 kgCOD/\'M POT.3\'.day. The mean removal efficiencies of DQOraw, DQOfiltered, BODraw, BODfiltered, TSS and VSS were 65%; 64%; 80%; 70%; 58% and 69%. The effluent had an average of 245 mgCODraw/L; 117 mgCODfiltered/L; 104 mgBODraw/L; 76 mgBODfiltered/L; 88 mgTSS/L and 69 mgVSS/L. The ammonification obtained was 90%, demonstrating the potencial of the system in the conversion of organic matter into ammonia nitrogen. For the second stage, the most efficient in the removal of organic matter was obtained with hydraulic detention time of 16 hours when it was removed from 0.29 kgCODraw/\'M POT.\'3.day, which was applied 0.84 kgCODraw/\'M POT.3\'.day. The mean removal efficiencies of CODfiltered and BODfiltered were 80% and 95%, respectively. The effluent had an average of 72 mgCODfiltered/L, and 13 mgBODfiltered/L. The ammonification obtained was 85%, however there was low efficiency in oxidation of ammonia-\'N\', at most 25%, and the maximum concentrations in the effluent were 4 mg\'N\'-\'NO IND.2\'POT.-\'/L and 2 mg\'N\'-\'NO IND.3\'POT.-\'/L, respectively. Regarding the distribution of material support, it was found that the proportion of activated granular carbon and anthracite carbon was higher on sand, in different points of collection, whereas this proportion tended to drop over the sample, moreover, was found that the characteristics of the flow are not adequate to provide fluidization/expansion of the bed of particles. The best results obtained in the simulation of the flotation of the effluent when it was applied with recirculation of air concentration of 17.5 mgair/Lsample, and ascension velocity of 10 cm/min. Removal efficiencies of TSS; FSS; VSS; COD, color and turbidity were obtained from 64; 82; 62; 62; 53 and 73%, respectively. The effluent had 63 mgTSS/L; 5 mgFSS/L; 59 mgVSS/L; 127 mgCODraw/L; 431 uC and 29 uT.
|
Page generated in 0.0612 seconds