• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação de coagulantes no afluente de reator anaeróbio de leito expandido alimentado com esgoto sanitário. / Application of coagulants to anaerobic expanded bed reactor influent fed by domestic wastewater

Santos, Hélio Rodrigues dos 20 April 2001 (has links)
Os reatores anaeróbios de tratamento de esgoto possibilitam elevada remoção de matéria orgânica, com menor custo em comparação com os processos aeróbios. Entretanto, esses reatores geralmente são pouco eficientes na remoção de nutrientes e seu efluente pode apresentar valores relativamente elevados de DQO e de sólidos suspensos. Por isso, investigou-se a aplicação de cloreto férrico e auxiliares de floculação no afluente de um reator anaeróbio de leito expandido em escala real (Volume = 32 m3; TDH = 3,2 h), no intuito de elevar as eficiências de remoção de DQO, turbidez, fósforo e sólidos. Foram realizados testes de Atividade Metanogênica para avaliar a toxicidade do cloreto férrico ao lodo do reator, mas nenhum efeito tóxico foi detectado para concentrações de até 500 mg FeCl3/l. Em seguida, foram realizados testes em reator de bancada (jar test), quando foi investigado o uso de cloreto férrico (dosagens entre 40 e 200 mg/l) em conjunto com um polímero catiônico, um polímero aniônico e amido natural de batata (dosagens entre 0,5 e 2,0 mg/l), sendo obtidos os melhores resultados com cloreto férrico e polímero aniônico. As eficiências médias diárias de remoção no reator de leito expandido foram elevadas de 64% para 71%, para DQO; de 47% para 59%, para turbidez; de 17% para 31%, para fósforo; e de 52% para 77%, para SST, quando aplicadas dosagens de 40 mg/l de cloreto férrico e 1,0 mg/l de polímero aniônico. / Anaerobic reactors for wastewater treatment have high capacity in removing organic matter and lower costs in comparison with aerobic processes. Nevertheless, anaerobic reactors generally are less efficient in nutrient removal and their effluents may present relatively high COD and total suspended solid (TSS) concentrations. Hence, the application of ferric chloride (FeCl3) and flocculant aids to a full-scale (Volume = 32 m3; HRT = 3,2 h) anaerobic expanded bed reactor influent was investigated to improve removal of COD, turbidity, phosphorous and solids. Methanogenic activity tests were conducted to evaluate toxicity of ferric chloride against methanogenic anaerobic reactor sludge. Tests showed that no toxic effect occurred before concentrations of FeCl3 reached 500 mg/l. Conventional bench-scale jar tests were conducted and ferric chloride was tested in combination with a cationic polymer, an anionic polymer and natural potato starch. Best results were obtained when ferric chloride was employed with anionic polymer. Average daily removal rates were increased from 64% to 71% for COD, from 47% to 59% for turbidity, from 17% to 31% for phosphorous and from 52% to 77% for TSS when dosages close to 40 mg/l of ferric chloride and 1,0 mg/l of anionic polymer were applied to anaerobic expanded bed reactor influent.
2

Tratamento de esgoto sanitário em um reator de leito expandido em escala plena, operado com regiões anaeróbia e aeróbia sobrepostas / Treatment of sanitary wastewater in a full scale expanded bed reactor, operated with overlap anaerobic and aerobic regions

Rafael Ceribelli da Silva 26 June 2009 (has links)
A presente pesquisa teve como objetivo principal a avaliação do desempenho de um reator de leito expandido (159,0 \'M POT.3\'), em escala plena, operado sob condições anaeróbia e anaeróbia-aeróbia sobrepostas, tratando esgoto sanitário. Como objetivos específicos, foi avaliado o uso de areias comerciais para complementação do leito de partículas, bem como a distribuição do material suporte ao longo da altura do reator. Além disso, houve a simulação da flotação do efluente do sistema a fim de otimizar a eficiência na remoção de sólidos, visto pela ineficiência do sistema na separação dos sólidos biológicos. Dentre os materiais selecionados para compor o leito de partículas, foi escolhida a areia com tamanho médio dos grãos igual a 0,69 mm e massa específica de 2690 kg.\'M POT.-3\'. Esta pesquisa foi dividida em duas etapas experimentais, sendo que a primeira o sistema foi operado somente sob a condição anaeróbia, enquanto na segunda, o sistema foi submetido à condição anaeróbia e aeróbia sobrepostas. Para a primeira etapa, o sistema obteve maior eficiência na remoção de matéria orgânica, com TDH de 14 horas, quando foi removido 0,84 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 1,26 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQObruta, DQOfilt, DBObruta, DBOfilt, SST e SSV foram de 65%; 64%; 80%; 70%; 58% e 69%. O efluente apresentou, em média, 245 mgDQObruta/L, 117 mgDQOfilt/L, 104 mgDBObruta/L, 76 mgDBOfilt/L; 88 mgSST/L e 69 mgSSV/L. O grau de amonificação obtido foi de 90%, evidenciando a potenciabilidade do sistema na conversão de matéria nitrogenado orgânico em amoniacal. Para a segunda etapa, a maior eficiência na remoção de matéria orgânica foi obtida com TDH de 16 horas, quando foi removido 0,29 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 0,84 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQOfilt e DBOfiltr foram de 80% e 95%, respectivamente. O efluente apresentou, em média, 72 mgDQOfiltr/L, e 13 mgDBOfiltr/L. O grau de amonificação obtido foi de 85%, no entanto houve baixa eficiência na oxidação do \'N\'-amoniacal, no máximo 25%, sendo que as concentrações máximas no efluente foram de 4 mg\'N\'-\'NO IND.2\'POT.-\'/L e 2 mg\'NO IND.3\'POT.-\'/L, respectivamente. Em relação à distribuição do material suporte, foi verificada que a proporção de carvão ativado granular e carvão antracitoso foi superior em relação à areia, nos diferentes pontos de coleta, sendo que essa proporção tendeu a se reduzir ao longo das amostragens, além disso, foram verificadas que as características do fluxo não estão adequadas para proporcionar a fluidificação/expansão do leito de partículas. Os melhores resultados obtidos na simulação da flotação do efluente, quando foi aplicada recirculação com concentração de ar de 17,5 mgar/Lam, e velocidade ascensional de 10 cm/min. As eficiências de remoção de SST; SSF; SSV; DQO, cor e turbidez obtidas foram de 64; 82; 62; 62; 53 e 73%, respectivamente. O efluente flotado apresentou 63 mgSST/L; 5 mgSSF/L; 59 mgSSV/L; 127 mgDQObruta/L, 431 uC e 29 uT. / This present research had as main objective the evaluation of the performance of a full scale expanded bed reactor (159.0 \'M POT.3\'), operated under anaerobic and overlapping anaerobic-aerobic, treating sanitary wastewater. As specific objectives, it was evaluated using commercial sand to complement the bed of particles and distribution of material support along the height of reactor. Besides, it was simulated the flotation of the effluent system in order to optimize the efficient removal of solids, due to inefficiency of the system in the separation of biological solids. Among the materials selected to compose the bed of particles was chosen with the average size of sand grains equal to 0.69 mm and density of 2690 kg.\'M POT.-3\'. This research was divided into two experimental stages, the first being that the system was operated only under the anaerobic condition, while the second, the system was submited to anaerobic and aerobic conditions overlaped. For the first step, the system achieved greater efficiency in removing organic matter, with hydraulic detention time of 14 hours, when it was removed from 0.84 kgCODraw/\'M POT.3\'.day, which was applied 1.26 kgCOD/\'M POT.3\'.day. The mean removal efficiencies of DQOraw, DQOfiltered, BODraw, BODfiltered, TSS and VSS were 65%; 64%; 80%; 70%; 58% and 69%. The effluent had an average of 245 mgCODraw/L; 117 mgCODfiltered/L; 104 mgBODraw/L; 76 mgBODfiltered/L; 88 mgTSS/L and 69 mgVSS/L. The ammonification obtained was 90%, demonstrating the potencial of the system in the conversion of organic matter into ammonia nitrogen. For the second stage, the most efficient in the removal of organic matter was obtained with hydraulic detention time of 16 hours when it was removed from 0.29 kgCODraw/\'M POT.\'3.day, which was applied 0.84 kgCODraw/\'M POT.3\'.day. The mean removal efficiencies of CODfiltered and BODfiltered were 80% and 95%, respectively. The effluent had an average of 72 mgCODfiltered/L, and 13 mgBODfiltered/L. The ammonification obtained was 85%, however there was low efficiency in oxidation of ammonia-\'N\', at most 25%, and the maximum concentrations in the effluent were 4 mg\'N\'-\'NO IND.2\'POT.-\'/L and 2 mg\'N\'-\'NO IND.3\'POT.-\'/L, respectively. Regarding the distribution of material support, it was found that the proportion of activated granular carbon and anthracite carbon was higher on sand, in different points of collection, whereas this proportion tended to drop over the sample, moreover, was found that the characteristics of the flow are not adequate to provide fluidization/expansion of the bed of particles. The best results obtained in the simulation of the flotation of the effluent when it was applied with recirculation of air concentration of 17.5 mgair/Lsample, and ascension velocity of 10 cm/min. Removal efficiencies of TSS; FSS; VSS; COD, color and turbidity were obtained from 64; 82; 62; 62; 53 and 73%, respectively. The effluent had 63 mgTSS/L; 5 mgFSS/L; 59 mgVSS/L; 127 mgCODraw/L; 431 uC and 29 uT.
3

Tratamento de esgoto sanitário em um reator de leito expandido em escala plena, operado com regiões anaeróbia e aeróbia sobrepostas / Treatment of sanitary wastewater in a full scale expanded bed reactor, operated with overlap anaerobic and aerobic regions

Silva, Rafael Ceribelli da 26 June 2009 (has links)
A presente pesquisa teve como objetivo principal a avaliação do desempenho de um reator de leito expandido (159,0 \'M POT.3\'), em escala plena, operado sob condições anaeróbia e anaeróbia-aeróbia sobrepostas, tratando esgoto sanitário. Como objetivos específicos, foi avaliado o uso de areias comerciais para complementação do leito de partículas, bem como a distribuição do material suporte ao longo da altura do reator. Além disso, houve a simulação da flotação do efluente do sistema a fim de otimizar a eficiência na remoção de sólidos, visto pela ineficiência do sistema na separação dos sólidos biológicos. Dentre os materiais selecionados para compor o leito de partículas, foi escolhida a areia com tamanho médio dos grãos igual a 0,69 mm e massa específica de 2690 kg.\'M POT.-3\'. Esta pesquisa foi dividida em duas etapas experimentais, sendo que a primeira o sistema foi operado somente sob a condição anaeróbia, enquanto na segunda, o sistema foi submetido à condição anaeróbia e aeróbia sobrepostas. Para a primeira etapa, o sistema obteve maior eficiência na remoção de matéria orgânica, com TDH de 14 horas, quando foi removido 0,84 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 1,26 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQObruta, DQOfilt, DBObruta, DBOfilt, SST e SSV foram de 65%; 64%; 80%; 70%; 58% e 69%. O efluente apresentou, em média, 245 mgDQObruta/L, 117 mgDQOfilt/L, 104 mgDBObruta/L, 76 mgDBOfilt/L; 88 mgSST/L e 69 mgSSV/L. O grau de amonificação obtido foi de 90%, evidenciando a potenciabilidade do sistema na conversão de matéria nitrogenado orgânico em amoniacal. Para a segunda etapa, a maior eficiência na remoção de matéria orgânica foi obtida com TDH de 16 horas, quando foi removido 0,29 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 0,84 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQOfilt e DBOfiltr foram de 80% e 95%, respectivamente. O efluente apresentou, em média, 72 mgDQOfiltr/L, e 13 mgDBOfiltr/L. O grau de amonificação obtido foi de 85%, no entanto houve baixa eficiência na oxidação do \'N\'-amoniacal, no máximo 25%, sendo que as concentrações máximas no efluente foram de 4 mg\'N\'-\'NO IND.2\'POT.-\'/L e 2 mg\'NO IND.3\'POT.-\'/L, respectivamente. Em relação à distribuição do material suporte, foi verificada que a proporção de carvão ativado granular e carvão antracitoso foi superior em relação à areia, nos diferentes pontos de coleta, sendo que essa proporção tendeu a se reduzir ao longo das amostragens, além disso, foram verificadas que as características do fluxo não estão adequadas para proporcionar a fluidificação/expansão do leito de partículas. Os melhores resultados obtidos na simulação da flotação do efluente, quando foi aplicada recirculação com concentração de ar de 17,5 mgar/Lam, e velocidade ascensional de 10 cm/min. As eficiências de remoção de SST; SSF; SSV; DQO, cor e turbidez obtidas foram de 64; 82; 62; 62; 53 e 73%, respectivamente. O efluente flotado apresentou 63 mgSST/L; 5 mgSSF/L; 59 mgSSV/L; 127 mgDQObruta/L, 431 uC e 29 uT. / This present research had as main objective the evaluation of the performance of a full scale expanded bed reactor (159.0 \'M POT.3\'), operated under anaerobic and overlapping anaerobic-aerobic, treating sanitary wastewater. As specific objectives, it was evaluated using commercial sand to complement the bed of particles and distribution of material support along the height of reactor. Besides, it was simulated the flotation of the effluent system in order to optimize the efficient removal of solids, due to inefficiency of the system in the separation of biological solids. Among the materials selected to compose the bed of particles was chosen with the average size of sand grains equal to 0.69 mm and density of 2690 kg.\'M POT.-3\'. This research was divided into two experimental stages, the first being that the system was operated only under the anaerobic condition, while the second, the system was submited to anaerobic and aerobic conditions overlaped. For the first step, the system achieved greater efficiency in removing organic matter, with hydraulic detention time of 14 hours, when it was removed from 0.84 kgCODraw/\'M POT.3\'.day, which was applied 1.26 kgCOD/\'M POT.3\'.day. The mean removal efficiencies of DQOraw, DQOfiltered, BODraw, BODfiltered, TSS and VSS were 65%; 64%; 80%; 70%; 58% and 69%. The effluent had an average of 245 mgCODraw/L; 117 mgCODfiltered/L; 104 mgBODraw/L; 76 mgBODfiltered/L; 88 mgTSS/L and 69 mgVSS/L. The ammonification obtained was 90%, demonstrating the potencial of the system in the conversion of organic matter into ammonia nitrogen. For the second stage, the most efficient in the removal of organic matter was obtained with hydraulic detention time of 16 hours when it was removed from 0.29 kgCODraw/\'M POT.\'3.day, which was applied 0.84 kgCODraw/\'M POT.3\'.day. The mean removal efficiencies of CODfiltered and BODfiltered were 80% and 95%, respectively. The effluent had an average of 72 mgCODfiltered/L, and 13 mgBODfiltered/L. The ammonification obtained was 85%, however there was low efficiency in oxidation of ammonia-\'N\', at most 25%, and the maximum concentrations in the effluent were 4 mg\'N\'-\'NO IND.2\'POT.-\'/L and 2 mg\'N\'-\'NO IND.3\'POT.-\'/L, respectively. Regarding the distribution of material support, it was found that the proportion of activated granular carbon and anthracite carbon was higher on sand, in different points of collection, whereas this proportion tended to drop over the sample, moreover, was found that the characteristics of the flow are not adequate to provide fluidization/expansion of the bed of particles. The best results obtained in the simulation of the flotation of the effluent when it was applied with recirculation of air concentration of 17.5 mgair/Lsample, and ascension velocity of 10 cm/min. Removal efficiencies of TSS; FSS; VSS; COD, color and turbidity were obtained from 64; 82; 62; 62; 53 and 73%, respectively. The effluent had 63 mgTSS/L; 5 mgFSS/L; 59 mgVSS/L; 127 mgCODraw/L; 431 uC and 29 uT.
4

Aplicação de coagulantes no afluente de reator anaeróbio de leito expandido alimentado com esgoto sanitário. / Application of coagulants to anaerobic expanded bed reactor influent fed by domestic wastewater

Hélio Rodrigues dos Santos 20 April 2001 (has links)
Os reatores anaeróbios de tratamento de esgoto possibilitam elevada remoção de matéria orgânica, com menor custo em comparação com os processos aeróbios. Entretanto, esses reatores geralmente são pouco eficientes na remoção de nutrientes e seu efluente pode apresentar valores relativamente elevados de DQO e de sólidos suspensos. Por isso, investigou-se a aplicação de cloreto férrico e auxiliares de floculação no afluente de um reator anaeróbio de leito expandido em escala real (Volume = 32 m3; TDH = 3,2 h), no intuito de elevar as eficiências de remoção de DQO, turbidez, fósforo e sólidos. Foram realizados testes de Atividade Metanogênica para avaliar a toxicidade do cloreto férrico ao lodo do reator, mas nenhum efeito tóxico foi detectado para concentrações de até 500 mg FeCl3/l. Em seguida, foram realizados testes em reator de bancada (jar test), quando foi investigado o uso de cloreto férrico (dosagens entre 40 e 200 mg/l) em conjunto com um polímero catiônico, um polímero aniônico e amido natural de batata (dosagens entre 0,5 e 2,0 mg/l), sendo obtidos os melhores resultados com cloreto férrico e polímero aniônico. As eficiências médias diárias de remoção no reator de leito expandido foram elevadas de 64% para 71%, para DQO; de 47% para 59%, para turbidez; de 17% para 31%, para fósforo; e de 52% para 77%, para SST, quando aplicadas dosagens de 40 mg/l de cloreto férrico e 1,0 mg/l de polímero aniônico. / Anaerobic reactors for wastewater treatment have high capacity in removing organic matter and lower costs in comparison with aerobic processes. Nevertheless, anaerobic reactors generally are less efficient in nutrient removal and their effluents may present relatively high COD and total suspended solid (TSS) concentrations. Hence, the application of ferric chloride (FeCl3) and flocculant aids to a full-scale (Volume = 32 m3; HRT = 3,2 h) anaerobic expanded bed reactor influent was investigated to improve removal of COD, turbidity, phosphorous and solids. Methanogenic activity tests were conducted to evaluate toxicity of ferric chloride against methanogenic anaerobic reactor sludge. Tests showed that no toxic effect occurred before concentrations of FeCl3 reached 500 mg/l. Conventional bench-scale jar tests were conducted and ferric chloride was tested in combination with a cationic polymer, an anionic polymer and natural potato starch. Best results were obtained when ferric chloride was employed with anionic polymer. Average daily removal rates were increased from 64% to 71% for COD, from 47% to 59% for turbidity, from 17% to 31% for phosphorous and from 52% to 77% for TSS when dosages close to 40 mg/l of ferric chloride and 1,0 mg/l of anionic polymer were applied to anaerobic expanded bed reactor influent.
5

Coagulação/precipitação de efluentes de reator anaeróbio de leito expandido e de sistema de lodo ativado precedido de reator UASB, com remoção de partículas por sedimentação ou flotação / Coagulation/precipitation of effluents from anaerobic expanded bed reactor and activated sludge system preceded by UASB reactor, with particle removal by sedimentation or flotation

Santos, Hélio Rodrigues dos 08 June 2006 (has links)
Os reatores anaeróbios de concepção mais moderna (e.g., UASB e RALEx) possibilitam a remoção de 65 a 75% de matéria orgânica do esgoto sanitário, com custos de implantação e operação relativamente baixos, em comparação com os processos aeróbios convencionais. Entretanto, esses reatores geralmente são pouco eficientes na remoção de nutrientes e seus efluentes podem apresentar concentrações relativamente elevadas de material orgânico e de sólidos suspensos. Para melhorar a qualidade dos efluentes desses reatores, algumas configurações de pós-tratamento têm sido empregadas no Brasil, dentre as quais os sistemas de lodo ativado e a coagulação/precipitação com sais metálicos, geralmente seguida de flotação por ar dissolvido. Nesta pesquisa, foi avaliada a aplicabilidade da coagulação/precipitação com cloreto férrico, a partir de testes em unidades de coagulação em escala de bancada (jar test e flotateste), para três sistemas de pós-tratamento de efluentes de reatores anaeróbios, a saber: coagulação/precipitação do efluente de um reator anaeróbio (RALEx); co-precipitação em um sistema de lodo ativado; e pós-precipitação do efluente do sistema de lodo ativado. Cada um desses sistemas foi testado com separação de sólidos por sedimentação ou por flotação por ar dissolvido, constituindo seis distintas configurações de pós-tratamento. O pós-tratamento do efluente do reator anaeróbio por coagulação/precipitação se mostrou uma alternativa viável técnica e economicamente, tanto para a sedimentação quanto para a flotação por ar dissolvido. Os diagramas de coagulação obtidos tanto nos ensaios de sedimentação quanto nos de flotação demonstraram que a coagulação/precipitação do efluente do RALEx ocorria de modo mais eficiente para valores de pH entre 5 e 7. A coagulação/precipitação do licor misto com cloreto férrico também se mostrou uma opção atrativa, propiciando a obtenção de efluente bastante clarificado, com possibilidades de reúso. Nessa opção, obtiveram-se eficiências adicionais (i.e., em relação ao sobrenadante do licor misto) de remoção de turbidez, DQO e fósforo de, respectivamente, 80%, 72% e 85%, com dosagem de 80 mg de \'FE\'\'CL IND.3\'.6\'H IND.2\'O/L (48 mg de \'FE\'\'CL IND.3\'/L). Para a coagulação com cloreto férrico, a flotação não apresentou bons resultados na remoção de turbidez, DQO e fósforo para separação de sólidos do licor misto. O mesmo ocorreu para o efluente final da ETE quando a etapa de separação de sólidos foi a sedimentação. Quando a separação de sólidos foi feita por flotação, obtiveram-se eficiências de remoção de turbidez, DQO e fósforo de, respectivamente, 68%, 53% e 83%, com dosagem de 80 mg de \'FE\'\'CL IND.3\'.6\'H IND.2\'O/L / The anaerobic reactors of modern conception (e.g., UASB and RALEx) remove from 65 to 75% of sanitary wastewater organic matter with relatively low construction, operation, and maintenance costs, in comparison with conventional aerobic processes. Nevertheless, that reactors are usually little efficient in nutrient removal and their effluents may present relatively high organic matter and suspended solid concentrations. In order to improve the quality of effluents from anaerobic reactors, some post-treatment concepts have been employed in Brazil, among which activated sludge systems and coagulation/precipitation with metallic salts, generally followed by dissolved air flotation. In this research, coagulation/precipitation with ferric chloride was assessed using sedimentation and flotation lab-scale test units (jar test and flotateste, respectively) to three post-treatment systems, namely: coagulation/precipitation of effluent from anaerobic reactor; co-precipitation (in the mixed liquor from activated sludge system); and post-precipitation of effluent from activated sludge system. Each system was assessed with solids separation with sedimentation and dissolved air flotation, constituting six different post-treatment scenarios. Coagulation/precipitation of the effluent from the anaerobic reactor showed to be technical and economically attractive, not only for sedimentation but also for dissolved air flotation. Coagulation diagrams obtained in sedimentation and flotation essays showed that coagulation/precipitation of the effluent from RALEX was more efficient when pH values were between 5 and 7. The mixed liquor coagulation/flocculation with ferric chloride were also an attractive option, resulting in a low turbidity effluent suitable for reuse. In this option, additional removals (i.e., in relation to decanted mixed liquor) of turbidity, COD e phosphorus were obtained: 80%, 72% and 85%, respectively, with the dosage of 80 mg \'FE\'\'CL IND.3\'.6\'H IND.2\'O/L (48 mg \'FE\'\'CL IND.3\'/L). Flotation did not presented good results in the removal of turbidity, COD and phosphorus in mixed liquor coagulation/precipitation with ferric chloride. The same was to the effluent from the WWTP when sedimentation was employed in the solids separation step. When solids separation was made using flotation, the removal efficiencies of turbidity, COD and phosphorus were, respectively, 68%, 53%, and 83% for the dosage of 80 mg \'FE\'\'CL IND.3\'.6\'H IND.2\'O/L
6

Coagulação/precipitação de efluentes de reator anaeróbio de leito expandido e de sistema de lodo ativado precedido de reator UASB, com remoção de partículas por sedimentação ou flotação / Coagulation/precipitation of effluents from anaerobic expanded bed reactor and activated sludge system preceded by UASB reactor, with particle removal by sedimentation or flotation

Hélio Rodrigues dos Santos 08 June 2006 (has links)
Os reatores anaeróbios de concepção mais moderna (e.g., UASB e RALEx) possibilitam a remoção de 65 a 75% de matéria orgânica do esgoto sanitário, com custos de implantação e operação relativamente baixos, em comparação com os processos aeróbios convencionais. Entretanto, esses reatores geralmente são pouco eficientes na remoção de nutrientes e seus efluentes podem apresentar concentrações relativamente elevadas de material orgânico e de sólidos suspensos. Para melhorar a qualidade dos efluentes desses reatores, algumas configurações de pós-tratamento têm sido empregadas no Brasil, dentre as quais os sistemas de lodo ativado e a coagulação/precipitação com sais metálicos, geralmente seguida de flotação por ar dissolvido. Nesta pesquisa, foi avaliada a aplicabilidade da coagulação/precipitação com cloreto férrico, a partir de testes em unidades de coagulação em escala de bancada (jar test e flotateste), para três sistemas de pós-tratamento de efluentes de reatores anaeróbios, a saber: coagulação/precipitação do efluente de um reator anaeróbio (RALEx); co-precipitação em um sistema de lodo ativado; e pós-precipitação do efluente do sistema de lodo ativado. Cada um desses sistemas foi testado com separação de sólidos por sedimentação ou por flotação por ar dissolvido, constituindo seis distintas configurações de pós-tratamento. O pós-tratamento do efluente do reator anaeróbio por coagulação/precipitação se mostrou uma alternativa viável técnica e economicamente, tanto para a sedimentação quanto para a flotação por ar dissolvido. Os diagramas de coagulação obtidos tanto nos ensaios de sedimentação quanto nos de flotação demonstraram que a coagulação/precipitação do efluente do RALEx ocorria de modo mais eficiente para valores de pH entre 5 e 7. A coagulação/precipitação do licor misto com cloreto férrico também se mostrou uma opção atrativa, propiciando a obtenção de efluente bastante clarificado, com possibilidades de reúso. Nessa opção, obtiveram-se eficiências adicionais (i.e., em relação ao sobrenadante do licor misto) de remoção de turbidez, DQO e fósforo de, respectivamente, 80%, 72% e 85%, com dosagem de 80 mg de \'FE\'\'CL IND.3\'.6\'H IND.2\'O/L (48 mg de \'FE\'\'CL IND.3\'/L). Para a coagulação com cloreto férrico, a flotação não apresentou bons resultados na remoção de turbidez, DQO e fósforo para separação de sólidos do licor misto. O mesmo ocorreu para o efluente final da ETE quando a etapa de separação de sólidos foi a sedimentação. Quando a separação de sólidos foi feita por flotação, obtiveram-se eficiências de remoção de turbidez, DQO e fósforo de, respectivamente, 68%, 53% e 83%, com dosagem de 80 mg de \'FE\'\'CL IND.3\'.6\'H IND.2\'O/L / The anaerobic reactors of modern conception (e.g., UASB and RALEx) remove from 65 to 75% of sanitary wastewater organic matter with relatively low construction, operation, and maintenance costs, in comparison with conventional aerobic processes. Nevertheless, that reactors are usually little efficient in nutrient removal and their effluents may present relatively high organic matter and suspended solid concentrations. In order to improve the quality of effluents from anaerobic reactors, some post-treatment concepts have been employed in Brazil, among which activated sludge systems and coagulation/precipitation with metallic salts, generally followed by dissolved air flotation. In this research, coagulation/precipitation with ferric chloride was assessed using sedimentation and flotation lab-scale test units (jar test and flotateste, respectively) to three post-treatment systems, namely: coagulation/precipitation of effluent from anaerobic reactor; co-precipitation (in the mixed liquor from activated sludge system); and post-precipitation of effluent from activated sludge system. Each system was assessed with solids separation with sedimentation and dissolved air flotation, constituting six different post-treatment scenarios. Coagulation/precipitation of the effluent from the anaerobic reactor showed to be technical and economically attractive, not only for sedimentation but also for dissolved air flotation. Coagulation diagrams obtained in sedimentation and flotation essays showed that coagulation/precipitation of the effluent from RALEX was more efficient when pH values were between 5 and 7. The mixed liquor coagulation/flocculation with ferric chloride were also an attractive option, resulting in a low turbidity effluent suitable for reuse. In this option, additional removals (i.e., in relation to decanted mixed liquor) of turbidity, COD e phosphorus were obtained: 80%, 72% and 85%, respectively, with the dosage of 80 mg \'FE\'\'CL IND.3\'.6\'H IND.2\'O/L (48 mg \'FE\'\'CL IND.3\'/L). Flotation did not presented good results in the removal of turbidity, COD and phosphorus in mixed liquor coagulation/precipitation with ferric chloride. The same was to the effluent from the WWTP when sedimentation was employed in the solids separation step. When solids separation was made using flotation, the removal efficiencies of turbidity, COD and phosphorus were, respectively, 68%, 53%, and 83% for the dosage of 80 mg \'FE\'\'CL IND.3\'.6\'H IND.2\'O/L

Page generated in 0.0664 seconds