• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fidelidade de modelos virtuais tridimensionais: avaliação por meio de engenharia reversa

Queiroz, Christiano Sampaio January 2016 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2017-05-19T14:48:31Z No. of bitstreams: 1 CHRISTIANO SAMPAIO QUEIROZ_TESE DE DOUTORADO.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-07-03T15:24:40Z (GMT) No. of bitstreams: 1 CHRISTIANO SAMPAIO QUEIROZ_TESE DE DOUTORADO.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / Made available in DSpace on 2017-07-03T15:24:40Z (GMT). No. of bitstreams: 1 CHRISTIANO SAMPAIO QUEIROZ_TESE DE DOUTORADO.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / A engenharia reversa refere-se a tecnologias capazes de capturar modelos físicos e representá-los com a linguagem da computação como modelos virtuais. Estes modelos virtuais podem ser utilizados com finalidades das mais diversas, sendo, na área da saúde, importantes no diagnóstico e planejamento cirúrgico. Para isto, quanto mais fiéis ao modelo físico, maior a segurança nestes procedimentos. O presente trabalho comparou o volume de modelos tridimensionais gerados por diferentes formas de engenharia reversa: escaneamento tridimensional superficial, tomografia computadorizada helicoidal com uma fileira de detectores, com multidetectores de 4 canais, com multidetectores de 128 canais e tomografia computadorizada de feixe cônico. Foram utilizadas oito mandíbulas secas humanas, as quais foram submetidas aos referidos exames de aquisição de imagem. Os arquivos dos exames feitos pelos tomógrafos foram salvos no formato DICOM em mídia eletrônica e processados no programa 3D Doctor® (Able Corporation, Massachusetts, EUA) para a obtenção das reconstruções virtuais tridimensionais, nas quais foram utilizadas, ainda, duas formas diferentes de segmentação: all boundary e outline only. Todos os modelos foram salvos no formato standard triangle language (STL) e comparados volumetricamente entre si. Concluiu-se que as diferentes formas de engenharia reversa geraram modelos virtuais tridimensionais cujos volumes não apresentaram diferença estatisticamente significante, independente da técnica de segmentação utilizada. Quanto ao uso de diferentes técnicas de segmentação em imagens obtidas por um mesmo tomógrafo houve estatisticamente significante no volume dos modelos virtuais tridimensionais gerados. / Reverse engineering refers to technologies able to capture physical models and represent them through computer language as virtual models. These virtual models can be used for diverse purposes. In the medical field, they are important in diagnosis and surgical planning for patients. For this, the more true to the physical model, the greater the safety in these procedures. Thus, this study compared the volume of threedimensional models generated by different forms of reverse engineering: surface three-dimensional scanning, helical computed tomography with a row of detectors, multidetector 4-channel, multidetector 128 channels and cone beam computed tomography. Eight human dry mandibles were submitted to these image acquisition examinations. File examinations by CT scans were saved in DICOM format on electronic media and processed in 3D Doctor® software (Able Corporation, Massachusetts, USA) to obtain the virtual three-dimensional reconstructions, as well as submitted to two different types of segmentation: all boundary and outline only. All models were saved in a standard triangle language (STL) format and compared volumetrically to each other. It was concluded that the different forms of reverse engineering generated three-dimensional virtual models with volumes without statistical differences between them, regardless of the segmentation technique used, while the use of different segmentation techniques in images obtained by the same scanner generated three-dimensional virtual models with volumes showing statistical differences between them.
2

Fidelidade de modelos virtuais tridimensionais: avaliação por meio de engenharia reversa.

Queiroz, Christiano Sampaio January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2018-02-05T14:49:03Z No. of bitstreams: 1 Tese_ODONTO_ Christiano Sampaio Queiroz.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2018-02-16T16:40:14Z (GMT) No. of bitstreams: 1 Tese_ODONTO_ Christiano Sampaio Queiroz.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / Made available in DSpace on 2018-02-16T16:40:14Z (GMT). No. of bitstreams: 1 Tese_ODONTO_ Christiano Sampaio Queiroz.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / A engenharia reversa refere-se a tecnologias capazes de capturar modelos físicos e representá-los com a linguagem da computação como modelos virtuais. Estes modelos virtuais podem ser utilizados com finalidades das mais diversas, sendo, na área da saúde, importantes no diagnóstico e planejamento cirúrgico. Para isto, quanto mais fiéis ao modelo físico, maior a segurança nestes procedimentos. O presente trabalho comparou o volume de modelos tridimensionais gerados por diferentes formas de engenharia reversa: escaneamento tridimensional superficial, tomografia computadorizada helicoidal com uma fileira de detectores, com multidetectores de 4 canais, com multidetectores de 128 canais e tomografia computadorizada de feixe cônico. Foram utilizadas oito mandíbulas secas humanas, as quais foram submetidas aos referidos exames de aquisição de imagem. Os arquivos dos exames feitos pelos tomógrafos foram salvos no formato DICOM em mídia eletrônica e processados no programa 3D Doctor® (Able Corporation, Massachusetts, EUA) para a obtenção das reconstruções virtuais tridimensionais, nas quais foram utilizadas, ainda, duas formas diferentes de segmentação: all boundary e outline only. Todos os modelos foram salvos no formato standard triangle language (STL) e comparados volumetricamente entre si. Concluiu-se que as diferentes formas de engenharia reversa geraram modelos virtuais tridimensionais cujos volumes não apresentaram diferença estatisticamente significante, independente da técnica de segmentação utilizada. Quanto ao uso de diferentes técnicas de segmentação em imagens obtidas por um mesmo tomógrafo houve estatisticamente significante no volume dos modelos virtuais tridimensionais gerados.
3

Avaliação da acurácia de reconstruções 3d por diferentes softwares e tomógrafos: estudo experimental ex vivo

Pimentel, Poliana Andrade January 2011 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-11-18T16:35:54Z No. of bitstreams: 1 Dissertação_ODONTO_ Poliana Andrade Pimentel.pdf: 953776 bytes, checksum: bb56eef45edcdb25caa67055dc51d189 (MD5) / Rejected by Flávia Ferreira (flaviaccf@yahoo.com.br), reason: Por favor verificar nome do orientador(a) on 2013-11-19T12:01:01Z (GMT) / Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-11-19T17:24:39Z No. of bitstreams: 1 Dissertação_ODONTO_ Poliana Andrade Pimentel.pdf: 953776 bytes, checksum: bb56eef45edcdb25caa67055dc51d189 (MD5) / Approved for entry into archive by Flávia Ferreira (flaviaccf@yahoo.com.br) on 2013-11-19T20:48:18Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_ Poliana Andrade Pimentel.pdf: 953776 bytes, checksum: bb56eef45edcdb25caa67055dc51d189 (MD5) / Made available in DSpace on 2013-11-19T20:48:19Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_ Poliana Andrade Pimentel.pdf: 953776 bytes, checksum: bb56eef45edcdb25caa67055dc51d189 (MD5) / FAPESB / O objetivo deste estudo foi avaliar a acurácia de reconstruções tridimensionais (3D) de tomografia computadorizada (TC) geradas por diferentes softwares, equipamentos tomográficos e espessura de cortes. Foram utilizadas dez mandíbulas secas humanas, as quais foram submetidas a exame de TC fan beam (TC médica) e cone beam (TC de feixe cônico - TCFC). Os arquivos dos exames salvos no formato DICOM em mídia eletrônica foram processados em diferentes softwares [Onis-Viewer® (DigitalCore, Co. Ltd, Tóquio, Japão); InVesalius® (CTI, Campinas, Brasil); 3D Doctor® (Able Corporation, Massachusetts, EUA); e OsiriX Imaging Software® (Pixmeo SARL, Genebra, Suiça)] para confecção das reconstruções 3D. Foram realizadas medidas lineares verticais e horizontais dos defeitos ósseos, produzidos nas mandíbulas secas, com auxílio de um paquímetro eletrônico digital, e em suas respectivas reconstruções virtuais utilizando as réguas oferecidas pelos softwares. As medidas foram realizadas por dois examinadores, duas vezes, e os dados foram comparados e submetidos à análise estatística. Os resultados mostraram haver diferenças estatisticamente significativas nas distâncias lineares dos defeitos ósseos, entre as mandíbulas secas humanas e suas respectivas reconstruções 3D, tanto geradas por diferentes softwares, quanto pelos diferentes tomógrafos (TCFC e TC médica) e espessuras (0,3mm e 0,4mm). O erro relativo para as imagens obtidas a partir da TCFC variou de 3,10% a 4,82% a depender do software e espessura utilizada, e para aquelas obtidas a partir da TC fan beam variou de 3,40 a 5,92%, a depender do software. Apesar dos resultados, as discrepâncias não foram maiores que 0,6mm em média, e portanto os erros encontrados não devem afetar o planejamento terapêutico nem a confecção de um biomodelo.
4

Avaliação da acurácia de reconstruções 3d por diferentes softwares e tomógrafos: estudo experimental ex vivo

Pimentel, Poliana Andrade 16 December 2011 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-04-11T16:20:31Z No. of bitstreams: 1 Dissertação_ODONTO_Poliana Andrade Pimentel.pdf: 1365077 bytes, checksum: fb2ddd9821ad5312c14054a041273b04 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-07-03T15:39:12Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_Poliana Andrade Pimentel.pdf: 1365077 bytes, checksum: fb2ddd9821ad5312c14054a041273b04 (MD5) / Made available in DSpace on 2017-07-03T15:39:12Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_Poliana Andrade Pimentel.pdf: 1365077 bytes, checksum: fb2ddd9821ad5312c14054a041273b04 (MD5) / FAPESB / O objetivo deste estudo foi avaliar a acurácia de reconstruções tridimensionais (3D) de tomografia computadorizada (TC) geradas por diferentes softwares, equipamentos tomográficos e espessura de cortes. Foram utilizadas dez mandíbulas secas humanas, as quais foram submetidas a exame de TC fan beam (TC médica) e cone beam (TC de feixe cônico - TCFC). Os arquivos dos exames salvos no formato DICOM em mídia eletrônica foram processados em diferentes softwares [Onis-Viewer® (DigitalCore, Co. Ltd, Tóquio, Japão); InVesalius® (CTI, Campinas, Brasil); 3D Doctor® (Able Corporation, Massachusetts, EUA); e OsiriX Imaging Software® (Pixmeo SARL, Genebra, Suiça)] para confecção das reconstruções 3D. Foram realizadas medidas lineares verticais e horizontais dos defeitos ósseos, produzidos nas mandíbulas secas, com auxílio de um paquímetro eletrônico digital, e em suas respectivas reconstruções virtuais utilizando as réguas oferecidas pelos softwares. As medidas foram realizadas por dois examinadores, duas vezes, e os dados foram comparados e submetidos à análise estatística. Os resultados mostraram haver diferenças estatisticamente significativas nas distâncias lineares dos defeitos ósseos, entre as mandíbulas secas humanas e suas respectivas reconstruções 3D, tanto geradas por diferentes softwares, quanto pelos diferentes tomógrafos (TCFC e TC médica) e espessuras (0,3mm e 0,4mm). O erro relativo para as imagens obtidas a partir da TCFC variou de 3,10% a 4,82% a depender do software e espessura utilizada, e para aquelas obtidas a partir da TC fan beam variou de 3,40 a 5,92%, a depender do software. Apesar dos resultados, as discrepâncias não foram maiores que 0,6mm em média, e portanto os erros encontrados não devem afetar o planejamento terapêutico nem a confecção de um biomodelo.
5

Avaliação da acurácia de reconstruções 3d por diferentes softwares e tomógrafos: estudo experimental ex vivo/

Pimentel, Poliana Andrade 16 December 2011 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-07-27T17:18:02Z No. of bitstreams: 1 Dissertação_ODONTO_ Poliana Andrade Pimentel.pdf: 1223428 bytes, checksum: 16d0290736d8b540edb36ba563d2f2f9 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-07-28T14:37:31Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_ Poliana Andrade Pimentel.pdf: 1223428 bytes, checksum: 16d0290736d8b540edb36ba563d2f2f9 (MD5) / Made available in DSpace on 2017-07-28T14:37:31Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_ Poliana Andrade Pimentel.pdf: 1223428 bytes, checksum: 16d0290736d8b540edb36ba563d2f2f9 (MD5) / FAPESB / O objetivo deste estudo foi avaliar a acurácia de reconstruções tridimensionais (3D) de tomografia computadorizada (TC) geradas por diferentes softwares, equipamentos tomográficos e espessura de cortes. Foram utilizadas dez mandíbulas secas humanas, as quais foram submetidas a exame de TC fan beam (TC médica) e cone beam (TC de feixe cônico - TCFC). Os arquivos dos exames salvos no formato DICOM em mídia eletrônica foram processados em diferentes softwares [Onis-Viewer® (DigitalCore, Co. Ltd, Tóquio, Japão); InVesalius® (CTI, Campinas, Brasil); 3D Doctor® (Able Corporation, Massachusetts, EUA); e OsiriX Imaging Software® (Pixmeo SARL, Genebra, Suiça)] para confecção das reconstruções 3D. Foram realizadas medidas lineares verticais e horizontais dos defeitos ósseos, produzidos nas mandíbulas secas, com auxílio de um paquímetro eletrônico digital, e em suas respectivas reconstruções virtuais utilizando as réguas oferecidas pelos softwares. As medidas foram realizadas por dois examinadores, duas vezes, e os dados foram comparados e submetidos à análise estatística. Os resultados mostraram haver diferenças estatisticamente significativas nas distâncias lineares dos defeitos ósseos, entre as mandíbulas secas humanas e suas respectivas reconstruções 3D, tanto geradas por diferentes softwares, quanto pelos diferentes tomógrafos (TCFC e TC médica) e espessuras (0,3mm e 0,4mm). O erro relativo para as imagens obtidas a partir da TCFC variou de 3,10% a 4,82% a depender do software e espessura utilizada, e para aquelas obtidas a partir da TC fan beam variou de 3,40 a 5,92%, a depender do software. Apesar dos resultados, as discrepâncias não foram maiores que 0,6mm em média, e portanto os erros encontrados não devem afetar o planejamento terapêutico nem a confecção de um biomodelo.

Page generated in 0.1256 seconds