• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

MALHAS DE AMOSTRAGEM RETANGULAR E HEXAGONAL NA GERAÇÃO DE MAPAS DE FERTILIDADE E APLICAÇÃO PARA AGRICULTURA DE PRECISÃO / SAMPLING GRID RECTANGULAR AND HEXAGONAL GENERATION OF MAPS OF FERTILITY AND APLICATION FOR AGRICULTURE OF PRECISION

Schio, Leonice 15 September 2016 (has links)
Sample grid s are essential when we want to represent the variation in chemical and physical properties of the soil, being essential to know its features. In this way, this study aimed to relate the efficiency and practicality of using soil sampling knits of rectangular and hexagonal type in a farm located countryside Ivorá- RS. In order to get features that help the researcher and producer in choosing the appropriate mesh to represent and diagnose their crops by means of fertility maps and application. The methodological procedures consisted of structuring the rectangular and hexagonal sampling knits of 1 ha in the CR Campeiro 7, without user interference in the point s distribution. Soil samples were collected in June 2015. So, after analysis of the spatial distribution of points in the area for each of the cases the fertility maps and application were structured. Among the main results, it is noted that both knits can represent similarly the trends that the soil presents nevertheless, the rectangular grid, due to a higher number of points, can represent the variability more expressively, but was found that when there is a change in the position and number of sampling points in a crop, the representations of the maps have differences, which at first, analyzing only the fertility maps, these differences seem small, but when structured a map of application, this difference becomes significant as it will result in greater or lesser purchase of inputs. It is emphasized that each mesh has characteristics that will inevitably vary from crop to crop, and a sampling grid should be, always, planned and adjusted according to each case, combining the knowledge of the producer and additional data available to define the same. / As malhas de amostragem são fundamentais quando desejamos representar a variação de atributos químicos e físicos do solo, sendo imprescindível conhecer suas características. Desta forma, este trabalho teve como objetivo relacionar a eficiência e a praticidade da utilização das malhas de amostragem de solo do tipo retangular e hexagonal, em uma lavoura localizada no município de Ivorá- RS. Com o propósito de buscar características que auxiliem o pesquisador e o produtor na escolha da malha adequada para representar e diagnosticar suas lavouras, através de mapas de fertilidade e de aplicação. Os procedimentos metodológicos consistiram em estruturar as malhas de amostragem retangular e hexagonal de 1 ha no Sistema CR Campeiro 7, sem a interferência do usuário na distribuição dos pontos. As respectivas coletas de solo ocorreram no mês de junho de 2015. Assim, após a análise da distribuição espacial dos pontos na área para cada um dos casos e estruturados os mapas de fertilidade e aplicação. Entre os principais resultados encontrados, salienta-se que ambas as malhas conseguem representar de forma similar as tendências que o solo apresenta, no entanto, a malha retangular, por apresentar maior número de pontos, consegue representar a variabilidade de forma mais expressiva, mas nota-se que quando há uma alteração na posição e no número de pontos amostrais em uma lavoura, as representações dos mapas apresentam diferenças, que num primeiro momento, analisando somente os mapas de fertilidade, essas diferenças parecem ser pequenas, mas quando estruturado um mapa de aplicação, essa diferença passa a ser significativa, pois resultará em maior ou menor aquisição de insumos. Salienta-se que cada malha apresenta características que, inevitavelmente, variam de lavoura para lavoura, e uma malha de amostragem deve ser, sempre, planejada e ajustada conforme cada caso, aliando o conhecimento do produtor e dados adicionais disponíveis para definição da mesma.
2

Medição e análise de planeza de superfícies metrológicas usando nível eletrônico e os métodos de Moody e malha retangular

Andrade, Joab Sobreira de 23 July 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-05-30T12:14:08Z No. of bitstreams: 1 arquivototal.pdf: 3048567 bytes, checksum: 90279484ba802361ba0d5d0da55c46d9 (MD5) / Made available in DSpace on 2017-05-30T12:14:08Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3048567 bytes, checksum: 90279484ba802361ba0d5d0da55c46d9 (MD5) Previous issue date: 2015-07-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Surface tables are extremely important in engineering due to the fact that they serve as a primary reference in both the measurement and inspection of workpieces. Such surfaces must be properly calibrated to provide high quality level in the measurement and inspection tests. Flatness is the metrological characteristic used to evaluate the accuracy level of the surface tables. There are several norms that deals with surface tables flatness and establish tolerance limit or accuracy degrees regarding to the surface tables dimensions. This study aims to measure and analyze the surface table flatness by using electronic level along with Moody and rectangular grid methods according to the ISO 8512 standard. An electronic level was used to measure the inclining level of the surface tables, using the well-known Moody and rectangular grid methods. The Optical Analysis Software calculated all flatness deviations, showing them in isometric and numeric charts. The calculated closure errors show the high quality in the measurement data acquisition because the values showed in all tests satisfy the electronic level manufacturer’s recommendation, which means that the closure errors did not exceed 90% of the maximum peak. Therefore, the results of evaluated surface tables are validated as regards metrological quality. The results point out that the surface tables belongs to the “0” accuracy degree according to the ISO 8512 norms. This classification is extremely important in the determination and analysis of uncertainty and of traceability since surface tables are primary reference to obtain tolerance measures and analysis of engineering workpieces. Additionally, a computer system developed for determining the flatness was used to assess its capacity as a system alternative for data analysis and determination of flatness. Their results were satisfactory, with reliable values. / As mesas metrológicas são extremamente importantes na engenharia, pois elas servem de referência primária na medição e na inspeção de peças. Tais superfícies devem estar devidamente calibradas para que se garanta alto grau de qualidade nas medições e testes de inspeção. A planeza é a característica metrológica utilizada para avaliar o grau de exatidão das mesas desempeno. Há diversas normas que tratam sobre planeza de superfícies metrológicas e estabelecem limites de tolerância ou graus de exatidão em função das dimensões das mesas desempeno. O objetivo deste estudo foi determinar a planeza e consequentemente o grau de exatidão de duas mesas metrológicas utilizadas como mesas de referência em pesquisas realizadas no Laboratório de Engenharia de Precisão (LEP) da UFPB, em acordo com a norma ISO 8512. Um nível eletrônico de precisão foi utilizado para medir as inclinações das mesas metrológicas, utilizando os já conhecidos e difundidos métodos de Moody e de grade retangular. O Optical Analysis Software calculou todos os desvios de planeza, exibindo-os em forma de gráfico isométrico e em quadro de valores numéricos. Os erros de fechamento calculados mostram alta qualidade na aquisição de dados de medição, pois os valores apresentados em todos os testes satisfazem a recomendação do fabricante do nível eletrônico, ou seja, os erros de fechamento não excederam 90% do pico máximo (maximum peak). Portanto, os resultados de planeza obtidos estão validados do ponto de vista da qualidade metrológica. Os resultados apontaram que a mesas metrológicas avaliadas pertencem ao grau de exatidão “0”, segundo a norma ISO 8512. Esta classificação é muito importante na análise e determinação de incerteza e rastreabilidade, uma vez que as mesas metrológicas servem de referência primária na obtenção de medidas e análise de tolerâncias de peças de engenharia. Adicionalmente, um sistema computacional desenvolvido para a determinação da planeza foi utilizado a fim de avaliar sua capacidade como uma alternativa de sistema para análise de dados e determinação da planeza. Seus resultados mostraram-se satisfatórios, apresentando valores confiáveis.

Page generated in 0.0699 seconds