• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da qualidade de concentrados de hemácias submetidos a temperaturas inadequadas de transporte / Assessment of the quality of red blood cell concentrates submitted to inadequate transport temperatures

Givisiez, Flávia Naves 28 June 2018 (has links)
Segundo a legislação brasileira e normas internacionais, os concentrados de hemácias (CH) devem ser mantidos sob controle rigoroso de temperatura, armazenados de 2 a 6°C e transportados de 1 a 10°C, por até 24 horas. Entretanto, não existem evidências científicas de que estes valores sejam relevantes para manutenção de qualidade, segurança e viabilidade dos CH. O objetivo deste trabalho foi monitorar parâmetros laboratoriais in vitro em dois tipos de CH (CPDA-1, preparado pela metodologia do plasma rico em plaquetas e em SAGM preparado pelo buffy-coat), no decorrer de condições normais de armazenamento e em temperaturas de transporte inadequadas. O trabalho foi executado em três etapas. Na primeira etapa, foram estabelecidos os valores de referência para os dois tipos de CH armazenados em condições normais, através de testes laboratoriais semanais para determinação de hematócrito, hemoglobina total, hemoglobina plasmática, grau de hemólise, glicose, lactato, desidrogenase lática e potássio. Na segunda etapa, amostras de CH foram submetidas a temperaturas entre -2°C e +1°C, ou entre 11 e 15°C, por um período de 6 horas ou 24 horas, no 14º dia de armazenamento. Na terceira etapa os CH foram expostos a condições de estresse extremo, submetendo-os a temperaturas entre -2°C e +1°C ou entre 22°C e 25°C, por período de 48 horas. Os resultados dos testes laboratoriais das segunda e terceira etapas foram comparados com controles e aos valores de referência da primeira etapa. Nas unidades de CH em CPDA-1 foram encontrados valores significativamente mais elevados de potássio, hemoglobina livre, grau de hemólise, lactato e LDH do que nos CH em SAGM, enquanto que a concentração de glicose foi muito mais baixa em CH-CPDA1. Na 2ª etapa, exposições por até 24 horas em temperaturas de até - 2°C ou até 15°C não causaram diferenças significativas nas dosagens de hemoglobina livre, grau de hemólise, glicose, lactato, LDH e potássio quando comparados aos controles. Amostras de CH-CPDA1, quando avaliadas imediatamente após período de 48 horas de exposição, apresentaram resultados de glicose superiores aos controles quando submetidas a -2°C e inferiores ao controle quando a 25°C. Exposições por até 48 horas em temperaturas de até -2°C ou até 25°C não causaram diferenças significativas na hemoglobina livre, grau de hemólise, lactato, LDH e potássio quando comparados aos controles, nos dois tipos de CH. Nesse trabalho foram elaborados perfis padrão de parâmetros laboratoriais para dois tipos de CH. Estes perfis padrão constituirão uma ferramenta de grande utilidade para controle de qualidade e monitoramento das lesões de armazenamento em bolsas de CH produzidas na Fundação HEMOMINAS. Nossos resultados demonstraram que bolsas dos dois tipos de CH submetidas a temperaturas de - 2°C ou 14°C por períodos inferiores a 24 horas não apresentam alterações significativas nos parâmetros laboratoriais avaliados in vitro e permitiram algumas elaboramos recomendações práticas e importantes para serviços de hemoterapia. Entretanto, ainda não existem ainda evidências suficientes na literatura para modificação das normas de temperatura e tempo de transporte atualmente preconizadas pela legislação nacional e internacional. / The Brazilian legislation and international guidelines require that red blood cell concentrates (RBC) are kept under a strict temperature control, stored between 2 and 6°C and transported between 1 and 10°C for up to 24 hours. Nevertheless, there is no scientific evidence that these values are relevant to maintain RBC quality, safety and viability. This study was performed in order to monitor in vitro laboratorial variables of two different RBC types (CPDA-1, prepared using the platelet-rich plasma methodology, or SAGM, prepared using the buffy-coat) stored under normal conditions or under inadequate temperatures during transportation. The study had three phases. In the first phase, weekly laboratorial tests were performed to establish the reference values of hematocrit, total hemoglobin, plasma hemoglobin, rate of hemolysis, glucose, lactate, lactic acid dehydrogenase (LDH) and potassium, for each of the RBC types stored under normal conditions. In the second phase, RBC samples were submitted to temperatures between -2°C and +1°C, or between 11 and 15°C, for 6 hours or 24 hours, on the 14th storage day. Laboratorial test results were compared to a control group (2-6°C) and to the reference values established in the 1st phase. In the third phase, RBCs were exposed to extreme stress, i.e., temperatures between -2°C and +1°C or between 22°C and 25°C, for 48 hours, and the laboratory test results were compared to a control group. CPDA1-RBC had higher levels of potassium, free hemoglobin, rate of hemolysis, lactate and LDH compared to SAGM-RBC, whereas glucose was significantly lower in CPDA1. In the second phase, exposure for up to 24 hours in temperatures until -2°C or 15°C had no effect on free hemoglobin, rate of hemolysis, glucose, lactate, LDH and potassium when compared to control. CPDA1 samples right after the 48-h exposure had higher glucose levels than controls when kept at -2°C and lower than control if exposed to 25°C. Exposures up to -2°C or 25°C for up to 48 hours had no effect on free hemoglobin, rate of hemolysis, lactate, LDH and potassium when compared to control groups, both for CPDA1-RBC and SAGM-RBC. In this study, it was established standards for laboratory analyses for two different RBC types. Such standards will comprise valuable and useful tools for the quality control and monitoring of storage lesions of RBC units produced by Fundação HEMOMINAS. Our results demonstrate that units from both RBC types submitted to -2°C or 14°C for up to 24 hours had no significant changes in in vitro laboratory variables and allow some practical and important recommendations for hemotherapy services. Nevertheless, there are not enough evidences in the literature to support changes in the current guidelines for transportation recommended by national and international legislation.
2

An in vitro comparison of cellular destruction and metabolic effects occurring in stored, leuco-reduced and irradiated red blood cells

Adams, Faieqa January 2016 (has links)
Thesis (MTech (Biomedical Technology))--Cape Peninsula University of Technology, 2016. / Biochemical and haematological changes occur in red blood cellular products during the recommended storage period of 35 to 42 days at 1°C to 6°C. The restriction of the sodium/potassium pump at specified temperatures result in low intracellular potassium ion levels while an increase in sodium ion levels are observed and acidosis occurs as a result of low pH concentrations due to glucose consumption. Structural and morphological changes occur such as the release of free haemoglobin, lactate dehydrogenase and potassium into the supernatant causing the formation of spheroechinocytes and osmotic fragility. All these factors negatively impact the rheological properties of blood. These changes that transpire in the red cells during the storage period are referred to as “storage lesions”. Transfusion-associated graft versus host disease is an immunological and often fatal adverse transfusion reaction with gamma irradiation of cellular blood products used as a preventative measure. Gamma irradiation exacerbates storage lesions and of particular concern has been the increased potassium levels resulting in neonatal and infant hyperkalaemia. The storage lesions occurring in non-irradiated red blood cellular products are well documented although the literature regarding its irradiated counterparts has been less studied. A study of this nature has not previously been done in Cape Town, South Africa.
3

Avaliação da qualidade de concentrados de hemácias submetidos a temperaturas inadequadas de transporte / Assessment of the quality of red blood cell concentrates submitted to inadequate transport temperatures

Flávia Naves Givisiez 28 June 2018 (has links)
Segundo a legislação brasileira e normas internacionais, os concentrados de hemácias (CH) devem ser mantidos sob controle rigoroso de temperatura, armazenados de 2 a 6°C e transportados de 1 a 10°C, por até 24 horas. Entretanto, não existem evidências científicas de que estes valores sejam relevantes para manutenção de qualidade, segurança e viabilidade dos CH. O objetivo deste trabalho foi monitorar parâmetros laboratoriais in vitro em dois tipos de CH (CPDA-1, preparado pela metodologia do plasma rico em plaquetas e em SAGM preparado pelo buffy-coat), no decorrer de condições normais de armazenamento e em temperaturas de transporte inadequadas. O trabalho foi executado em três etapas. Na primeira etapa, foram estabelecidos os valores de referência para os dois tipos de CH armazenados em condições normais, através de testes laboratoriais semanais para determinação de hematócrito, hemoglobina total, hemoglobina plasmática, grau de hemólise, glicose, lactato, desidrogenase lática e potássio. Na segunda etapa, amostras de CH foram submetidas a temperaturas entre -2°C e +1°C, ou entre 11 e 15°C, por um período de 6 horas ou 24 horas, no 14º dia de armazenamento. Na terceira etapa os CH foram expostos a condições de estresse extremo, submetendo-os a temperaturas entre -2°C e +1°C ou entre 22°C e 25°C, por período de 48 horas. Os resultados dos testes laboratoriais das segunda e terceira etapas foram comparados com controles e aos valores de referência da primeira etapa. Nas unidades de CH em CPDA-1 foram encontrados valores significativamente mais elevados de potássio, hemoglobina livre, grau de hemólise, lactato e LDH do que nos CH em SAGM, enquanto que a concentração de glicose foi muito mais baixa em CH-CPDA1. Na 2ª etapa, exposições por até 24 horas em temperaturas de até - 2°C ou até 15°C não causaram diferenças significativas nas dosagens de hemoglobina livre, grau de hemólise, glicose, lactato, LDH e potássio quando comparados aos controles. Amostras de CH-CPDA1, quando avaliadas imediatamente após período de 48 horas de exposição, apresentaram resultados de glicose superiores aos controles quando submetidas a -2°C e inferiores ao controle quando a 25°C. Exposições por até 48 horas em temperaturas de até -2°C ou até 25°C não causaram diferenças significativas na hemoglobina livre, grau de hemólise, lactato, LDH e potássio quando comparados aos controles, nos dois tipos de CH. Nesse trabalho foram elaborados perfis padrão de parâmetros laboratoriais para dois tipos de CH. Estes perfis padrão constituirão uma ferramenta de grande utilidade para controle de qualidade e monitoramento das lesões de armazenamento em bolsas de CH produzidas na Fundação HEMOMINAS. Nossos resultados demonstraram que bolsas dos dois tipos de CH submetidas a temperaturas de - 2°C ou 14°C por períodos inferiores a 24 horas não apresentam alterações significativas nos parâmetros laboratoriais avaliados in vitro e permitiram algumas elaboramos recomendações práticas e importantes para serviços de hemoterapia. Entretanto, ainda não existem ainda evidências suficientes na literatura para modificação das normas de temperatura e tempo de transporte atualmente preconizadas pela legislação nacional e internacional. / The Brazilian legislation and international guidelines require that red blood cell concentrates (RBC) are kept under a strict temperature control, stored between 2 and 6°C and transported between 1 and 10°C for up to 24 hours. Nevertheless, there is no scientific evidence that these values are relevant to maintain RBC quality, safety and viability. This study was performed in order to monitor in vitro laboratorial variables of two different RBC types (CPDA-1, prepared using the platelet-rich plasma methodology, or SAGM, prepared using the buffy-coat) stored under normal conditions or under inadequate temperatures during transportation. The study had three phases. In the first phase, weekly laboratorial tests were performed to establish the reference values of hematocrit, total hemoglobin, plasma hemoglobin, rate of hemolysis, glucose, lactate, lactic acid dehydrogenase (LDH) and potassium, for each of the RBC types stored under normal conditions. In the second phase, RBC samples were submitted to temperatures between -2°C and +1°C, or between 11 and 15°C, for 6 hours or 24 hours, on the 14th storage day. Laboratorial test results were compared to a control group (2-6°C) and to the reference values established in the 1st phase. In the third phase, RBCs were exposed to extreme stress, i.e., temperatures between -2°C and +1°C or between 22°C and 25°C, for 48 hours, and the laboratory test results were compared to a control group. CPDA1-RBC had higher levels of potassium, free hemoglobin, rate of hemolysis, lactate and LDH compared to SAGM-RBC, whereas glucose was significantly lower in CPDA1. In the second phase, exposure for up to 24 hours in temperatures until -2°C or 15°C had no effect on free hemoglobin, rate of hemolysis, glucose, lactate, LDH and potassium when compared to control. CPDA1 samples right after the 48-h exposure had higher glucose levels than controls when kept at -2°C and lower than control if exposed to 25°C. Exposures up to -2°C or 25°C for up to 48 hours had no effect on free hemoglobin, rate of hemolysis, lactate, LDH and potassium when compared to control groups, both for CPDA1-RBC and SAGM-RBC. In this study, it was established standards for laboratory analyses for two different RBC types. Such standards will comprise valuable and useful tools for the quality control and monitoring of storage lesions of RBC units produced by Fundação HEMOMINAS. Our results demonstrate that units from both RBC types submitted to -2°C or 14°C for up to 24 hours had no significant changes in in vitro laboratory variables and allow some practical and important recommendations for hemotherapy services. Nevertheless, there are not enough evidences in the literature to support changes in the current guidelines for transportation recommended by national and international legislation.
4

Estudo do impacto da doação de concentrados de hemácias duplas por aférese nos estoques de ferro de doadores de sangue do Centro Regional de Hemoterapia do HCFMRP-USP / Study of the impact of double red cell donation by apheresis on the iron storage of blood donors at the Regional Blood Center of Ribeirão Preto - HCFMRP-USP

Brunello, Aline Shiramizu Hisamitsu 14 March 2017 (has links)
Introdução: A técnica de doação de duplos concentrados de hemácias por aférese está disponível nos hemocentros desde 1997, quando este procedimento foi aprovado pela Food and Drug Administration (FDA). A legislação brasileira vigente segue as normas americanas para seleção de potenciais doadores de hemocomponentes por aférese e orienta que cada serviço tenha seu próprio protocolo para realizar esses procedimentos. Objetivo: Analisar o comportamento das reservas de ferro de doadores de duplos concentrados de hemácias por aférese, selecionados de acordo com as normas brasileiras vigentes a fim de auxiliar na definição de critérios seguros para seleção desses doadores. Casuística e Métodos: Foram coletadas amostras de sangue para exames de hemograma, ferro sérico, ferritina e UIBC (capacidade latente de ligação de ferro) de 75 doadores de hemácias duplas por aférese nos momentos pré-doação e quatro, cinco, seis e sete meses após a doação. A análise dos dados foi realizada com o uso do Graph Pad Prism versão 5.0. Resultados: A dosagem de ferritina pré-doação foi significativamente maior que nos meses subsequentes, mesmo após sete meses da coleta (148 ng/mL x 84,7 ng/mL x 91,2 ng/mL x 93,9 ng/mL x 112 ng/mL, p<0,0001). Não foi observada diferença significativa dos valores de hematócrito, ferro sérico e UIBC ao longo do estudo. Interessantemente, os doadores apresentaram contagem de hemoglobina na pré-doação menor que a coletada no sétimo mês após a doação de duplos concentrados de hemácias por aférese (15,3 g/dL x 15,7 g/dL , p<0.05). Os valores do volume corpuscular médio (VCM) foram significativamente menores com quatro e cinco meses após doação, comparados com os valores basais (87,67 FL x 86,74 FL, p<0,0001 e 87,67 FL x 87,27 FL, p<0,0161) e significativamente maiores com sete meses após a doação (87,67 FL x 88,14 FL, p=0,01). Foi observado aumento dos níveis de Hemoglobina corpuscular média (HCM) nos sexto (29,45 PG x 29,84 PG, p=0,0044) e sétimo meses após a doação (29,45 PG x 30,22 PG, p<0,0001), em comparação com os valores basais. Verificou-se, também, que os estoques de ferro apresentaram queda significativa após uma doação de duplos concentrados de hemácias, obtidos por aférese e que até sete meses após a doação não houve a devida recuperação dos estoques de ferro ao nível basal dos doadores em estudo. Houve, ainda, aumento dos valores da hemoglobina e do HCM e VCM a partir do sexto mês após a doação de hemácias duplas por aférese. Conclusão: Concluiu-se que, em doadores do sexo masculino de duplos concentrados de hemácias por aférese, a dosagem de ferritina deve ser realizada para melhor controle e segurança dos mesmos, e que se os valores da dosagem da ferritina forem <30 ng/dl, o doador deve ser impedido de doar; e se >30 ng/mL, recomenda-se liberar para nova doação somente após seis meses da doação anterior. Assim, novos estudos serão necessários para se adequarem as normas vigentes à população de doadores brasileiros, visando maior segurança e menor impacto da doação nos estoques de ferro do doador. / Introduction: The technique of double red cell donation by apheresis has been available in blood establishments since 1997, when this procedure was approved by the American FDA. The Brazilian legislation follows the American standards for the selection of potential donors of blood components by apheresis and advises every establishment to have their own protocol to carry out these procedures. Aim: The aim of this study was to analyze the behavior of the iron reserves of donors of double red cells concentrate by apheresis, selected in accordance with current Brazilian standards, in order to help define safer criteria for the selection of these donors. Casuistic and Methods: Blood samples were collected from 75 donors of double red blood cells by apheresis for tests of blood count, serum iron, ferritin and UIBC at the moment before donation and at four, five, six and seven months after donation. Data analysis was done using Graph Pad Prism version 5.0. Results: Pre-donation ferritin was significantly higher than in the subsequent months, even after seven months of the collection (148 x 84.7 x 91.2 x 93.9 x 112 ng/mL, p<0.0001). Interestingly, donors showed hemoglobin count at pre-donation lower than the hemoglobin collected at the seventh month after the donation of double concentrates by apheresis (15.3 x 15.7 g/dL, p<0.05). No significant difference was observed in the values of hematocrit, serum iron, UIBC (iron binding capacity) four, five, six and seven months after the donation of double concentrates by apheresis when compared to basal levels. The MCV values were significantly lower four and five months after donation, compared to basal levels (87.67 x 86.74 FL, p<0.0001 and 87.67 x 87.27 FL, p<0.0161) and significantly higher after seven months after donation (87.67 x 88.14 FL, p=0.01). We observed an increase in MHC in the sixth month (29.45 x 29.84 PG, p=0.004 PG 4) and seventh month after donation compared to basal levels (29.45 x 30.22 PG, p<0.0001). This study observed that a donation of double blood red cell concentrates obtained by apheresis caused a significant drop in iron stores that persisted even after seven months after donation. Conclusion: We also verified an increase of hemoglobin, MCV and MHC values from the sixth month after donation, compared to basal levels. Probably, both the double red cell donation by apheresis and the stimulus of erythropoiesis might have influenced the slow recovery of donors\' iron stores in this study. Thus, novel studies are necessary to adjust the current standards to the population of Brazilian donors, aiming a greater safety and lower impact of donation in the donor\'s iron storage.
5

Estudo do impacto da doação de concentrados de hemácias duplas por aférese nos estoques de ferro de doadores de sangue do Centro Regional de Hemoterapia do HCFMRP-USP / Study of the impact of double red cell donation by apheresis on the iron storage of blood donors at the Regional Blood Center of Ribeirão Preto - HCFMRP-USP

Aline Shiramizu Hisamitsu Brunello 14 March 2017 (has links)
Introdução: A técnica de doação de duplos concentrados de hemácias por aférese está disponível nos hemocentros desde 1997, quando este procedimento foi aprovado pela Food and Drug Administration (FDA). A legislação brasileira vigente segue as normas americanas para seleção de potenciais doadores de hemocomponentes por aférese e orienta que cada serviço tenha seu próprio protocolo para realizar esses procedimentos. Objetivo: Analisar o comportamento das reservas de ferro de doadores de duplos concentrados de hemácias por aférese, selecionados de acordo com as normas brasileiras vigentes a fim de auxiliar na definição de critérios seguros para seleção desses doadores. Casuística e Métodos: Foram coletadas amostras de sangue para exames de hemograma, ferro sérico, ferritina e UIBC (capacidade latente de ligação de ferro) de 75 doadores de hemácias duplas por aférese nos momentos pré-doação e quatro, cinco, seis e sete meses após a doação. A análise dos dados foi realizada com o uso do Graph Pad Prism versão 5.0. Resultados: A dosagem de ferritina pré-doação foi significativamente maior que nos meses subsequentes, mesmo após sete meses da coleta (148 ng/mL x 84,7 ng/mL x 91,2 ng/mL x 93,9 ng/mL x 112 ng/mL, p<0,0001). Não foi observada diferença significativa dos valores de hematócrito, ferro sérico e UIBC ao longo do estudo. Interessantemente, os doadores apresentaram contagem de hemoglobina na pré-doação menor que a coletada no sétimo mês após a doação de duplos concentrados de hemácias por aférese (15,3 g/dL x 15,7 g/dL , p<0.05). Os valores do volume corpuscular médio (VCM) foram significativamente menores com quatro e cinco meses após doação, comparados com os valores basais (87,67 FL x 86,74 FL, p<0,0001 e 87,67 FL x 87,27 FL, p<0,0161) e significativamente maiores com sete meses após a doação (87,67 FL x 88,14 FL, p=0,01). Foi observado aumento dos níveis de Hemoglobina corpuscular média (HCM) nos sexto (29,45 PG x 29,84 PG, p=0,0044) e sétimo meses após a doação (29,45 PG x 30,22 PG, p<0,0001), em comparação com os valores basais. Verificou-se, também, que os estoques de ferro apresentaram queda significativa após uma doação de duplos concentrados de hemácias, obtidos por aférese e que até sete meses após a doação não houve a devida recuperação dos estoques de ferro ao nível basal dos doadores em estudo. Houve, ainda, aumento dos valores da hemoglobina e do HCM e VCM a partir do sexto mês após a doação de hemácias duplas por aférese. Conclusão: Concluiu-se que, em doadores do sexo masculino de duplos concentrados de hemácias por aférese, a dosagem de ferritina deve ser realizada para melhor controle e segurança dos mesmos, e que se os valores da dosagem da ferritina forem <30 ng/dl, o doador deve ser impedido de doar; e se >30 ng/mL, recomenda-se liberar para nova doação somente após seis meses da doação anterior. Assim, novos estudos serão necessários para se adequarem as normas vigentes à população de doadores brasileiros, visando maior segurança e menor impacto da doação nos estoques de ferro do doador. / Introduction: The technique of double red cell donation by apheresis has been available in blood establishments since 1997, when this procedure was approved by the American FDA. The Brazilian legislation follows the American standards for the selection of potential donors of blood components by apheresis and advises every establishment to have their own protocol to carry out these procedures. Aim: The aim of this study was to analyze the behavior of the iron reserves of donors of double red cells concentrate by apheresis, selected in accordance with current Brazilian standards, in order to help define safer criteria for the selection of these donors. Casuistic and Methods: Blood samples were collected from 75 donors of double red blood cells by apheresis for tests of blood count, serum iron, ferritin and UIBC at the moment before donation and at four, five, six and seven months after donation. Data analysis was done using Graph Pad Prism version 5.0. Results: Pre-donation ferritin was significantly higher than in the subsequent months, even after seven months of the collection (148 x 84.7 x 91.2 x 93.9 x 112 ng/mL, p<0.0001). Interestingly, donors showed hemoglobin count at pre-donation lower than the hemoglobin collected at the seventh month after the donation of double concentrates by apheresis (15.3 x 15.7 g/dL, p<0.05). No significant difference was observed in the values of hematocrit, serum iron, UIBC (iron binding capacity) four, five, six and seven months after the donation of double concentrates by apheresis when compared to basal levels. The MCV values were significantly lower four and five months after donation, compared to basal levels (87.67 x 86.74 FL, p<0.0001 and 87.67 x 87.27 FL, p<0.0161) and significantly higher after seven months after donation (87.67 x 88.14 FL, p=0.01). We observed an increase in MHC in the sixth month (29.45 x 29.84 PG, p=0.004 PG 4) and seventh month after donation compared to basal levels (29.45 x 30.22 PG, p<0.0001). This study observed that a donation of double blood red cell concentrates obtained by apheresis caused a significant drop in iron stores that persisted even after seven months after donation. Conclusion: We also verified an increase of hemoglobin, MCV and MHC values from the sixth month after donation, compared to basal levels. Probably, both the double red cell donation by apheresis and the stimulus of erythropoiesis might have influenced the slow recovery of donors\' iron stores in this study. Thus, novel studies are necessary to adjust the current standards to the population of Brazilian donors, aiming a greater safety and lower impact of donation in the donor\'s iron storage.

Page generated in 0.1259 seconds