• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 187
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 193
  • 193
  • 122
  • 119
  • 73
  • 65
  • 64
  • 58
  • 56
  • 49
  • 49
  • 44
  • 37
  • 35
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Reconfiguração de redes de distribuição em situações de contingências considerando operação ilhada de PCH / Reconfiguration of distribution network in contingency conditions considering islanded operation of small hydro power plant

Lopes, Guilherme Stivanin 22 August 2014 (has links)
One of the main concerns of the power utilities is secure, continuously supplying electric power to customers, thus meeting so satisfy these as to regulatory requirements. Thus, the proposed paper presents a method of restoring the electric power supply applying the concepts of automatic reconfiguration of the aggregate distribution networks the possibility of islanded operation of small hydro (SHP), since the use of PCH so islanded in certain circumstances, or becomes only, or the best solution to be adopted in a contingency situation in order to reduce the impact of unwanted interruptions. Since the intrinsic decision making process of reconfiguration of distribution networks involves multiple objectives and constraints, the proposed methodology uses the Analytic Hierarchy Process (AHP) method, which is a very useful tool for issues involving multicriteria decision taken. Additionally, case studies for analysis and validation of the proposed methodology are presented. / Uma das principais preocupações das empresas distribuidoras de energia elétrica é garantir, de forma contínua, o fornecimento de energia elétrica aos seus clientes, atendendo assim tanto a satisfação desses quanto às exigências regulatórias. Sendo assim, o trabalho proposto visa apresentar uma metodologia de restabelecimento do fornecimento de energia elétrica aplicando os conceitos de reconfiguração automática das redes de distribuição agregados a possibilidade de operação ilhada de pequenas centrais hidroelétricas (PCHs), uma vez que a utilização de PCH de forma ilhada, em determinadas circunstâncias, torna-se ou a única, ou a melhor solução a ser adotada em uma situação de contingência com o objetivo de reduzir o impacto causado por interrupções indesejadas. Visto que a tomada de decisão intrínseca ao processo de reconfiguração das redes de distribuição envolve vários objetivos e restrições, a metodologia proposta utiliza o método Analytic Hierarchy Process (AHP) que representa uma ferramenta muito útil para questões envolvendo tomadas de decisão multicriteriais. Adicionalmente, são apresentados estudos de caso para análises e validações da metodologia proposta.
142

Estudo de características elétricas e térmicas de inversores para sistemas fotovoltaicos conectados à rede

Rampinelli, Giuliano Arns January 2010 (has links)
Os sistemas fotovoltaicos conectados à rede convertem diretamente a energia solar em energia elétrica entregando à rede elétrica de distribuição uma energia limpa e renovável. Esses sistemas são formados basicamente por um conjunto de módulos fotovoltaicos e inversores que são responsáveis por converterem energia elétrica em corrente contínua em energia elétrica em corrente alternada. Esta Tese apresenta um estudo de características elétricas e térmicas de inversores utilizados em sistemas conectados à rede a partir de uma análise teórica e experimental. Os ensaios de inversores foram realizados em duas etapas: a primeira etapa foi desenvolvida no Laboratório de Energia Solar (Labsol) da Universidade Federal do Rio Grande do Sul (UFRGS) onde foi utilizado um sistema fotovoltaico de 4,8 kWP e dez modelos de inversores de diferentes fabricantes. As características elétricas de inversores que foram medidas e analisadas são: eficiência de conversão de corrente contínua em corrente alternada, eficiência do seguidor do ponto de máxima potência, fator de potência e distorção harmônica na corrente e na tensão. Ensaios térmicos de inversores também foram realizados e os resultados apresentados e analisados. A segunda etapa dos ensaios foi desenvolvida no Laboratório de Energia Solar Fotovoltaica do Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT) na Espanha onde foi utilizado um sistema fotovoltaico de 3 kWP e sete modelos de inversores de diferentes fabricantes. Os inversores ensaiados são monofásicos de potência até 5 kW e de diferentes topologias (transformador de alta freqüência, baixa freqüência e sem transformador). A influência da tensão CC de entrada no comportamento da eficiência CC/CA e do fator de potência foi analisada. Os resultados obtidos nos ensaios permitiram o desenvolvimento de modelos matemáticos que descrevem o comportamento elétrico e térmico de inversores. Os modelos matemáticos propostos foram inseridos em um programa de simulação computacional desenvolvido no Labsol da UFRGS, denominado FVConect. A evolução dos resultados da simulação comparada valida plenamente os modelos utilizados. A análise dos resultados do comportamento de inversores amplia o conhecimento sobre o funcionamento desses equipamentos e a sua interação dinâmica com os demais componentes de sistemas fotovoltaicos conectados à rede. / Grid-connected photovoltaic systems directly convert solar energy into electrical energy delivering to the distribution grid a clean and renewable energy. These systems are basically formed by an array of photovoltaic modules and inverters. The inverters are responsible for converting direct current to alternating current. This Thesis presents a study of electrical and thermal characteristics of inverters used in grid-connected photovoltaic systems from a theoretical and experimental analysis. The inverters tests were carried out in two stages: the first stage was performed at Solar Energy Laboratory at Federal University of Rio Grande do Sul where it was used a 4,8 KWP grid-connected photovoltaic system and ten inverters of different manufacturers. The proposed mathematical models were inserted into computer simulation software developed at UFRGS named FVConect. The evolution of the simulation results compared to the experimental results validates the proposed models. The analysis of the behavior of the inverters improves the understanding of the operating of such equipment and their dynamic interaction with other grid-connected photovoltaic system components.
143

Transformador de estado sólido no controle de fluxo de potência em redes de distribuição /

Godoi, Lucas Antonio Alves de January 2018 (has links)
Orientador: Júlio Borges de Souza / Resumo: O transformador de estado sólido tem se apresentado como uma ferramenta indispensável na construção das novas redes elétricas inteligentes, uma vez que essa nova estrutura de rede altera o layout tradicional, viabilizando a conexão de fontes de energia descentralizadas. Contudo, essa conexão de sistemas de geração distribuída na rede originou a bidirecionalidade do fluxo de potência, resultando em um novo panorama para as atividades de operação e manutenção das redes para as distribuidoras de energia. A análise dos possíveis impactos técnicos gerados na rede de distribuição deve ser realizada, com o intuito de garantir um nível de qualidade energética dentro dos padrões estabelecidos pela Agência Nacional de Energia Elétrica – ANEEL. Dentre os impactos, destacam-se a elevação do nível de tensão e a alteração do fator de potência, ambos, produzidos pelo excesso de potência injetada na rede por este novo cenário de geração de energia. Nesse contexto, esta dissertação tem como principal objetivo analisar o comportamento de uma rede de distribuição genérica com penetração de geração distribuída e avaliar o perfil de tensão diante de diferentes níveis de inserção dessa geração na rede. As características de ajuste de tensão instantânea e capacidade de interação com sistemas de armazenamento que o transformador de estado sólido possui foram empregadas no auxílio da regulação dos níveis de tensão que se apresentaram fora dos padrões determinados pela resolução 794/2018 da ANEEL, qua... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The solid state transformer has been presented as an essential tool in the construction of new intelligent electric grids, since this new network structure changes the traditional layout, making possible the connection of decentralized energy sources. However, this connection of distributed generation systems in the network created the bidirectionality of the power flow, resulting in a new panorama for the power distributors concerning the networks activities of operation and maintenance. The analysis of the possible technical impacts generated in the distribution network should be carried out with the purpose of guaranteeing a level of energy quality within the standards established by the National Electric Energy Agency (ANEEL). Among the impacts, we highlight the elevation of the voltage level and the change in the power factor, both produced by the excess power injected into the grid by this new energy generation scenario. In this context, the main objective of this dissertation is to analyze the behavior of a generic distribution network with distributed generation penetration and to evaluate the voltage profile before different levels of insertion of this generation in the network. The solid state transformer has instantaneous voltage adjustment characteristics and interaction capacity with storage systems, which were used to aid in the regulation of voltage levels that were out of the standards determined by ANEEL resolution 794/2018, when a high level of distributed g... (Complete abstract click electronic access below) / Mestre
144

Transformador de estado sólido no controle de fluxo de potência em redes de distribuição / Solid state transformer in control of power flow in distribution networks

Godoi, Lucas Antonio Alves de 17 April 2018 (has links)
Submitted by Lucas Antonio Alves De Godoi (luksg@hotmail.com) on 2018-07-11T15:22:59Z No. of bitstreams: 1 Dissertação_Lucas _Godoi.pdf: 3300304 bytes, checksum: 429eb486ffbb167f9c7394e2d2e4b6f6 (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-07-11T17:29:00Z (GMT) No. of bitstreams: 1 godoy_laa_me_ilha.pdf: 3300304 bytes, checksum: 429eb486ffbb167f9c7394e2d2e4b6f6 (MD5) / Made available in DSpace on 2018-07-11T17:29:00Z (GMT). No. of bitstreams: 1 godoy_laa_me_ilha.pdf: 3300304 bytes, checksum: 429eb486ffbb167f9c7394e2d2e4b6f6 (MD5) Previous issue date: 2018-04-17 / O transformador de estado sólido tem se apresentado como uma ferramenta indispensável na construção das novas redes elétricas inteligentes, uma vez que essa nova estrutura de rede altera o layout tradicional, viabilizando a conexão de fontes de energia descentralizadas. Contudo, essa conexão de sistemas de geração distribuída na rede originou a bidirecionalidade do fluxo de potência, resultando em um novo panorama para as atividades de operação e manutenção das redes para as distribuidoras de energia. A análise dos possíveis impactos técnicos gerados na rede de distribuição deve ser realizada, com o intuito de garantir um nível de qualidade energética dentro dos padrões estabelecidos pela Agência Nacional de Energia Elétrica – ANEEL. Dentre os impactos, destacam-se a elevação do nível de tensão e a alteração do fator de potência, ambos, produzidos pelo excesso de potência injetada na rede por este novo cenário de geração de energia. Nesse contexto, esta dissertação tem como principal objetivo analisar o comportamento de uma rede de distribuição genérica com penetração de geração distribuída e avaliar o perfil de tensão diante de diferentes níveis de inserção dessa geração na rede. As características de ajuste de tensão instantânea e capacidade de interação com sistemas de armazenamento que o transformador de estado sólido possui foram empregadas no auxílio da regulação dos níveis de tensão que se apresentaram fora dos padrões determinados pela resolução 794/2018 da ANEEL, quando um alto nível de geração distribuída foi inserido na rede. / The solid state transformer has been presented as an essential tool in the construction of new intelligent electric grids, since this new network structure changes the traditional layout, making possible the connection of decentralized energy sources. However, this connection of distributed generation systems in the network created the bidirectionality of the power flow, resulting in a new panorama for the power distributors concerning the networks activities of operation and maintenance. The analysis of the possible technical impacts generated in the distribution network should be carried out with the purpose of guaranteeing a level of energy quality within the standards established by the National Electric Energy Agency (ANEEL). Among the impacts, we highlight the elevation of the voltage level and the change in the power factor, both produced by the excess power injected into the grid by this new energy generation scenario. In this context, the main objective of this dissertation is to analyze the behavior of a generic distribution network with distributed generation penetration and to evaluate the voltage profile before different levels of insertion of this generation in the network. The solid state transformer has instantaneous voltage adjustment characteristics and interaction capacity with storage systems, which were used to aid in the regulation of voltage levels that were out of the standards determined by ANEEL resolution 794/2018, when a high level of distributed generation was inserted into the network.
145

Metodologia baseada em medidas dispersas de tensão e árvores de decisão para localização de faltas em sistemas de distribuição modernos / Methodology based on dispersed voltage measures and decision trees for fault location in modern distribution systems

Marcel Ayres de Araújo 06 October 2017 (has links)
Nos sistemas de distribuição, a grande ramificação, radialidade, heterogeneidade, dinâmica das cargas e demais particularidades, impõem dificuldades à localização de faltas, representando um desafio permanente na busca por melhores indicadores de continuidade e confiabilidade no fornecimento de energia elétrica. A regulação incisiva dos órgãos do setor, a penetração de geração distribuída e a tendência de modernização trazida pelas redes inteligentes, demandam detalhados estudos para readequação dos sistemas elétricos a conjuntura atual. Neste contexto, esta tese propõe o desenvolvimento de uma metodologia para localização de faltas em sistemas de distribuição empregando a capacidade dos medidores inteligentes de monitoramento e de aquisição de tensão em diferentes pontos da rede elétrica. A abordagem proposta baseia-se na estimação, por ferramentas de aprendizado de máquina, das impedâncias de sequência zero e positiva entre os pontos de alocação dos medidores inteligentes e de ocorrência de falta, e do estado de sensibilização destes medidores frente a correntes de falta. Assim, calculando-se as respectivas distâncias elétricas em função das impedâncias estimadas e definidas as direções das mesmas em relação a topologia da rede, busca-se identificar o ponto ou área com maior sobreposição de distâncias elétricas como o local ou a região de maior probabilidade da falta em relação aos medidores inteligentes. Para tanto, faz-se uso combinado de ferramentas convencionais e inteligentes pela aplicação dos conceitos de análise de sistemas elétricos, diagnóstico dos desvios de tensão, e classificação de padrões por meio da técnica de aprendizado de máquina denominada Árvore de Decisão. Os resultados obtidos pela aplicação desta metodologia demonstram que o uso de informações redundantes fornecidas pelos medidores inteligentes minimiza os erros de estimação. Além disso, para a maior parte dos casos testados o erro absoluto máximo de localização da falta se concentra entre 200 m e 1000 m, o que reduz a busca pelo local de ocorrência da falta pelas equipes de manutenção da rede elétrica. / In distribution systems, the dense branching, radial pattern, heterogeneity, dynamic of the loads, and other characteristics create several difficulties in defining the fault location, representing a great challenge in the search for better continuity and reliability indicators of the electrical energy supply. The intense government regulations, the increasing use of distributed generation, and the trend towards modernization via smart grids require a detailed study in order to upgrade the current systems. In this context, this thesis proposes a methodology development for fault location in distribution systems with the use of smart meters monitors and the acquisition of voltage at different points in the electrical network. The proposed method is based on the estimation, using machine learning, of the state of awareness of smart meters across the fault currents and of the zero and positive sequence impedance between the location of these meters and of the fault occurrence. Therefore, by calculating the electrical distances as a function of the estimated impedances and defining its the direction in relation to the network topology, the point/region with the biggest superposition of the electrical distances can be assigned as the point/region with the highest probability of fault occurrence in relation to the smart probes. For this purpose, a machine learning technique named decision tree is used to apply concept analyses to the electrical systems, diagnosis of voltage deviations, and pattern recognition of the electrical systems. The results obtained by the application of this methodology demonstrate that the use of redundant information provided by the smart meters minimizes estimation errors. In addition, for most of the cases tested, the maximum absolute error of the fault location is concentrated between 200 m and 1000 m, which reduces the search for the fault location by the maintenance teams of the electrical network.
146

Estratégia de controle para inversores monofásicos conectados a redes com ampla faixa de parâmetros / Control strategy for single-phase grid-tied inverters with wide range of grid parameters

Liston Júnior, Roner André 20 April 2018 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta o projeto e análise de uma estratégia de controle para inversores monofásicos conectados a rede de distribuição de energia elétrica. A estratégia é projetada com o objetivo de atender os limites harmônicos do padrão IEEE 1547.2-2008 e ao mesmo tempo suportar uma faixa de variação dos parâmetros da rede elétrica, como frequência, resistência e indutância. Neste sentido, a estratégia envolve um conjunto de técnicas como: um sincronizador de fase e frequência; controladores de corrente e potência, com rejeição de harmônicos; amortecimento ativo; estimador de corrente; filtro digitais; entre outras. Para essa estratégia de controle, foi escolhido o controlador proporcional ressonante (PR) e um sincronizador de fase e frequência de segunda ordem (MSOGI-FLL) com capacidade de suportar variações usuais de frequência. Ainda, um filtro de conexão passivo do tipo LCL-LC e um algoritmo de rejeição o de harmônicos (HC) são utilizados para atender os limites de conteúdo harmônico. Para aumentar a margem de estabilidade do sistema é utilizado uma técnica de amortecimento ativo. Para implementação dessa técnica de amortecimento ativo é proposto um novo estimador da corrente do capacitor do filtro de conexão de fácil implementação e que suporta variações da impedância da rede elétrica, entre redes fracas e redes fortes. Esse trabalho também contribui com o projeto dos ganhos do controlador PR com amortecimento ativo apresentado a estabilidade em uma ampla de faixa de parâmetros da rede elétrica, o que pode caracterizar desde uma rede fraca até uma rede forte. Para validação experimental da estratégia proposta foi construído um protótipo de um inversor monofásico de 1 kW, com características similares de produtos comerciais, como custo e dimensões reduzidas. O funcionamento da estratégia de controle proposta e do conversor de potência foi verificado por meio de resultados experimentais. Os vários resultados apresentados no trabalho corroboram o bom desempenho do sistema projetado e analisado em simulações computacionais. A distorção harmônica total (DHT) da forma de onda de corrente ´e inferior a 2,3% em todos os casos analisados, atendendo o padrão IEEE 1547.2-2008. / This work presents the design and analysis of a control strategy for single-phase inverters connected to the electric power distribution network. The strategy is designed to comply with the harmonic limits of the IEEE 1547.2-2008 standard and at the same time support a range of grid parameters variation such as frequency, resistance and inductance. In this sense, the strategy involves a set of techniques such as: a phase and frequency syn- chronizer; current and power controllers with harmonic compensation; active damping; current estimator; digital filter; among others. For this control strategy, a resonant pro- portional controller (PR) and a second-order phase-frequency synchronizer (MSOGI-FLL) with the capacity to withstand usual frequency variations were chosen. Furthermore, a LCL-LC passive connection filter and a harmonic compensation algorithm (HC) are used to comply with the harmonic limits. To increase the stability of the system an active damping technique is used. To implement this active damping technique, it is proposed a new estimator of the filter capacitor current with an easy implementation and support for electrical grid impedance variations between weak grids and strong grids. This work contributes to the PR controller with active damping gains design seeking stability in a wide range of parameters of the electrical grid that characterizes from a weak grid to a strong grid. For experimental validation of the proposed strategy a prototype of a 1 kW single-phase inverter was built, with characteristics of commercial products, such as cost and dimensions restrictions. The operation of the power converter and the proposed control strategy was verified through experimental results. The various results presented in the paper corroborate the good performance of the system analyzed in computational simulations. The total harmonic distortion (DHT) of the current waveform is lower than % in all analyzed cases, meeting the IEEE 1547.2-2008 standard.
147

Medidor inteligente com uma interface para visualização de parâmetros elétricos e de qualidade de energia com suporte à detecção de origem de faltas / Smart meter with an interface for visualization of electrical and power quality parameters and fault source detection capability

Silva, João Vitor da 27 April 2018 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho é proposto e apresentado um medidor inteligente de energia elétrica considerando os métodos de medição classe S especificados no PRODIST e na norma IEC 61000-4-30. O medidor proposto calcula os valores eficazes de tensão e corrente, as potências aparente, ativa e reativa, o fator de potência, a frequência, as distorções harmônicas e detecta a ocorrência de variações de tensão de curta duração. Como principais contribuições deste trabalho, pode-se citar a avaliação de métodos existentes e a proposta de um novo método para detectar a origem de distúrbios em relação à localização do medidor. Propôs-se também uma interface gráfica que permite o monitoramento dos parâmetros elétricos e de qualidade de energia, e ainda possibilita a interação do consumidor para a obtenção o de informações detalhadas sobre o estado da rede. O medidor pode ser utilizado como um registrador de dados e permite o acesso à sua interface gráfica por meio da utilização da porta de comunicação ethernet. Para a validação inicial, realizaram-se simulações computacionais, a partir de um modelo de consumidor residencial, em diferentes cenários de operação. Na etapa de validação experimental, foi utilizada uma fonte de geração de sinais e realizaram se testes com o medidor conectado à rede de distribuição de baixa tensão. A partir destas etapas foi possível verificar o funcionamento da interface gráfica e validar o funcionamento do medidor inteligente proposto. / In this study, a smart meter is presented, which considers the class S measurement methods specified at IEC 61000-4-30 standard and PRODIST. The proposed smart meter calculates RMS voltage and current values, active, reactive and apparent powers, power factor, frequency, harmonic distortions and detects short duration voltage variations. As main contributions of this study, it can be mentioned the evaluation of existing methods and the proposal of a new method to determine on which side of a recording device a disturbance originates. It’s also developed a graphical interface that allows the monitoring of electrical and power quality parameters and it enables consumer interaction to get detailed power grid information. The smart meter can also be used as a data logger and it allows access to its graphical interface through ethernet communication port. For the initial validation, computer simulations were performed through a residential consumer model in different operating scenarios. The experimental validation tests were carried out using an AC power source and the smart meter has been connected to low-voltage distribution grid. Through these steps, it was possible to verify the interface operation and to validate the proposed smart meter operation.
148

Realização experimental de uma rede de fusíveis aleatórios via diluição / Experimental realization of a random fuse network via dilution

Vilela, Tatiane de Souza 26 February 2013 (has links)
Made available in DSpace on 2015-03-26T13:35:23Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1333032 bytes, checksum: 5720bc6ef2b28326d1e36d524df0c987 (MD5) Previous issue date: 2013-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The study of the process of fracture in disordered materials is of huge importance in various fields of science and technology. Thus, several network models have been proposed to investigate the process of rupture of these materials, in particular, the random fuse model (RFM).The fuse model is the electrical analog to the mechanic model where the elastic force is represented by the electric current and the displacement is represented by voltage. In this work, our main objective was to experimentally study the influence of disorder in the rupture process of a random network of fuses. The experimental apparatus consisted of a square lattice of size L x L, in which the edges are fuses (copper wires). The network vertices were connected with copper wires (diameter 0.031 mm and resistivity ρ = 1.69 x 10-8 Ωm). This process generates an weakly disordered system. The disorder was introduced via a dilution of the network, where copper wires edges randomly removed from the network. The rupture process consisted of applying a potential difference on the network and measuring the corresponding current. After this process we obtain did information, such as the behavior of the was network as a function of the degree of disorder represented by the parameter p, and plot depending on the size L of the network, which were analyzed according to the percolation theory and fractures. Our results indicate that near the critical parameter pc, quantities such as the average number of burned fuses that form the percolation cluster, the average size of the percolation cluster and the average resistance of the network, obey power laws with critical exponents that are apparently not related to the exponents provided by the percolation theory. / O estudo do processo de fratura em materiais desordenados é de imensa importância em vários ramos da ciência e da tecnologia. Assim, vários modelos de rede foram propostos para investigar o processo de ruptura destes materiais, em particular, o modelo de fusível aleatório (RFM). O modelo de fusíveis é o análogo elétrico do modelo elástico onde a força é representada pela corrente elétrica e o deslocamento é representado pela tensão elétrica. Neste trabalho nosso principal objetivo foi estudar, experimentalmente, a influência da desordem no processo de ruptura de uma rede de fusíveis aleatórios. O aparato experimental consiste de uma rede quadrada de tamanho L x L, na qual os lados dos quadrados são os fusíveis (fios de cobre). A rede foi preenchida com fios de cobre (com diâmetro de com 0,031 mm e resistividade ρ = 1.69 x 10-8 Ωm). Este processo gera um sistema fracamente desordenado. A desordem na rede foi introduzida via processo de diluição, onde alguns fios de cobre foram aleatoriamente removidos da rede. O processo de ruptura consiste em aplicar uma diferença de potencial na rede e medir a respectiva corrente. Após este processo podemos obter informações, como gráficos em função do grau de desordem representada pelo parâmetro p e gráficos em função do tamanho L da rede, que foram analisados de acordo com a teoria de percolação e fraturas. Nossos resultados indicam que próximo do parâmetro crítico pc, algumas grandezas tais como: o número médio de fusíveis queimados e retirados que formam o agregado de percolação, o tamanho médio do agregado de percolação e a resistência média da rede, obedecem a uma lei de potência, com expoentes críticos que aparentemente não estão relacionados com os expoentes previstos na teoria da percolação por ligação.
149

Power Line Communication: análise da viabilidade e desempenho técnico do padrão G3-PLC para o monitoramento de variáveis em ambiente industrial / Power Line Communication: analysis of technical feasibility of the standard G3-PLC for data transmission in industrial environment

Farias, Luiz da Rocha 22 February 2017 (has links)
Este trabalho apresenta uma análise da utilização da comunicação de banda estreita via rede elétrica (Power Line Communication - PLC) em ambiente industrial. Para análise, utilizou-se um kit de desenvolvimento para aplicações baseadas em PLC de acordo com o padrão G3-PLC. Ensaios experimentais e resultados são apresentados para diferentes cenários que simulam diversas situações existentes em um ambiente industrial. Demonstra-se a influência da inserção de ruídos no canal PLC, através do acionamento de inversores e motores, afim de verificar a influência desses elementos no desempenho da comunicação PLC. Como base comparativa, utilizou-se a distância máxima de transmissão normalizada da rede ASInterface, muito difundida em ambientes industriais. Recomendações relativas à técnica de modulação e tamanho do pacote de dados são apresentadas. Como resultado final, conclui-se que o padrão de comunicação G3-PLC e sua técnica de modulação ROBO atendem os requisitos de comunicação industrial, principalmente para aplicações de monitoramento de variáveis industriais, onde o tempo não é crítico. / This work presents an analysis of the narrowband communication through the power line (PLC) in an industrial environment. For analysis, a development kit for PLCbased applications according to the G3-PLC standard was used. Experimental tests and results for different scenarios that simulate various situations existing in an industrial environment. An influence of the insertion of noise in the PLC channel is demonstrated by the drive of inverters and motors, in order to verify a nonperformance influence of the PLC communication. As a comparative basis, a maximum standard transmission distance of the AS-Interface network was used, very widespread in industrial environments. Recommendations regarding the modulation technique and the size of the data packet are presented. As a final result, it is concluded that the G3-PLC communication standard and its ROBO modulation technique meet the requirements of industrial communication, especially for industrial variable monitoring applications where time is not critical.
150

Power Line Communication: análise da viabilidade e desempenho técnico do padrão G3-PLC para o monitoramento de variáveis em ambiente industrial / Power Line Communication: analysis of technical feasibility of the standard G3-PLC for data transmission in industrial environment

Farias, Luiz da Rocha 22 February 2017 (has links)
Este trabalho apresenta uma análise da utilização da comunicação de banda estreita via rede elétrica (Power Line Communication - PLC) em ambiente industrial. Para análise, utilizou-se um kit de desenvolvimento para aplicações baseadas em PLC de acordo com o padrão G3-PLC. Ensaios experimentais e resultados são apresentados para diferentes cenários que simulam diversas situações existentes em um ambiente industrial. Demonstra-se a influência da inserção de ruídos no canal PLC, através do acionamento de inversores e motores, afim de verificar a influência desses elementos no desempenho da comunicação PLC. Como base comparativa, utilizou-se a distância máxima de transmissão normalizada da rede ASInterface, muito difundida em ambientes industriais. Recomendações relativas à técnica de modulação e tamanho do pacote de dados são apresentadas. Como resultado final, conclui-se que o padrão de comunicação G3-PLC e sua técnica de modulação ROBO atendem os requisitos de comunicação industrial, principalmente para aplicações de monitoramento de variáveis industriais, onde o tempo não é crítico. / This work presents an analysis of the narrowband communication through the power line (PLC) in an industrial environment. For analysis, a development kit for PLCbased applications according to the G3-PLC standard was used. Experimental tests and results for different scenarios that simulate various situations existing in an industrial environment. An influence of the insertion of noise in the PLC channel is demonstrated by the drive of inverters and motors, in order to verify a nonperformance influence of the PLC communication. As a comparative basis, a maximum standard transmission distance of the AS-Interface network was used, very widespread in industrial environments. Recommendations regarding the modulation technique and the size of the data packet are presented. As a final result, it is concluded that the G3-PLC communication standard and its ROBO modulation technique meet the requirements of industrial communication, especially for industrial variable monitoring applications where time is not critical.

Page generated in 0.074 seconds