• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 15
  • 5
  • 4
  • 2
  • 2
  • Tagged with
  • 117
  • 117
  • 116
  • 25
  • 21
  • 16
  • 15
  • 15
  • 15
  • 11
  • 11
  • 11
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Second law analysis revisited: a critical look at its past development, a clarification of its terminology, and a demonstration of its use as a design tool through microcomputer programming

Rieves, Regina Dugan January 1985 (has links)
The second law is still rarely used as a design decision tool. However, information obtained from second law analysis is valuable in the design process for thermodynamic systems. This investigation reviews the past development of second law analysis. A clear, operational vocabulary is established. Then two examples of microcomputer-based design procedures are presented. The first is a second law analysis of refrigeration cycles. As a part of this example, the correlation of physical property data by simple methods is demonstrated. The second example is a second law analysis of gas turbine systems. The salient point is that all of this can be done on a microcomputer, and consequently is readily available to any engineer. / M.S.
112

Steam jet ejector cooling powered by low grade waste or solar heat

Meyer, Adriaan Jacobus 12 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2006. / A small scale steam jet ejector experimental setup was designed and manufactured. This ejector setup is of an open loop configuration and the boiler can operate in the temperature range of Tb = 85 °C to 140 °C. The typical evaporator liquid temperatures range from Te = 5 °C t o 10 °C while the typical water cooled condenser presure ranges from Pc = 1 . 70 kPa t o 5. 63 kPa (Tc = 15 °C to 35 °C). The boiler is powered by by two 4kW electric elements, while a 3kW electric element simulates the cooling load in the evaporator. The electric elements are controlled by means of variacs. The function ... / Centre for Renewable and Sustainable Energy Studies
113

Avaliação de um sistema de resfriamento passivo para o clima de Curitiba / Evaluation of an indirect passive cooling system under Curitiba climate

Lange, Sérgio Costa 31 May 2016 (has links)
O Resfriamento Evaporativo Direto (RED), baseado na aspersão de água sob a forma de gotículas no interior dos ambientes; e o Resfriamento Evaporativo Indireto (REI), caracterizado pela umidificação de coberturas e por produzir resfriamento sem aumentar a umidade relativa do interior da edificação, são estratégias de projeto bioclimático ainda relativamente pouco usadas no Brasil. O presente estudo tem por objetivo avaliar a aplicação de uma forma particular de REI (que alia o resfriamento evaporativo à inércia térmica propiciada por um reservatório d’água) para o condicionamento térmico de ambientes em situação de calor na cidade de Curitiba. Foram confeccionadas, monitoradas e comparadas inicialmente duas células-teste em escala reduzida: um Módulo de Controle (MC) e um Módulo Experimental (ME), sendo que o ME foi dotado de uma cobertura estanque constituída de um reservatório d’água sujeita à evaporação. Uma segunda configuração de ME também foi testada em um período de monitoramento subsequente, o que possibilitou comparar-se o efeito do resfriamento evaporativo com o uso isolado do sistema sem uso do REI, em situação apenas de aumento da massa térmica. Uma terceira configuração de ME buscou combinar o aumento da massa térmica aliado ao efeito do resfriamento evaporativo. Resultados apontam para a vantagem do uso do REI para o resfriamento interno das células- teste com: redução de 2,5°C da temperatura média e de 8,0°C de redução da temperatura máxima em relação ao caso base. Também foi verificado uma forte relação entre a temperatura interna devido ao resfriamento evaporativo e a depressão da temperatura de bulbo úmido. / Direct evaporative cooling systems (DECS) based on sprinkling water indoors in the form of droplets and indirect evaporative cooling systems (IECS), characterized by the use of wetted roof or wall surfaces for cooling without increasing the indoor air moisture, consist of interesting bioclimatic strategies still not quite explored in Brazil. This study aims to evaluate the use of a particular form of IECS (which combines evaporative cooling and thermal mass brought about by a water reservoir) for indoor thermal control in warm conditions in Curitiba, Two test cells were initially built, monitored and compared to each other: a control module (CM) and an experimental module (EM), the latter provided with an evaporative pond. A subsequent configuration of the system which cancels out the evaporative function of the system and that is solely based on the increase of thermal mass, was tested in a second monitoring round. A third configuration of EM combinig evaporative cooling and the increase of termal mass was tested. Results showed a higher effectiveness of the IECS for the indoor cooling of the tested cells. The average temperature in EM was reduced in 2.5°C and the maximum temperature was reduced in 8.0°C in comparison with the CM. Results also showed a strong relation between the wet-bulb temperature depression and the internal temperature decrease achieved by the evaporative cooling strategy.
114

Curriculum in mathematics for air conditioning and refrigeration

Soares, Darrow P. 01 January 1996 (has links)
No description available.
115

Anisotropic parameters of mesh fillers relevant to miniature cryocoolers

Landrum, Evan 08 April 2009 (has links)
Computational fluid dynamics (CFD) modeling is possibly the best available technique in designing and predicting the performance of Stirling and pulse tube refrigerators (PTR). One of the limitations of CFD modeling of these systems, however, is that it requires closure relations for the micro porous materials housed within their regenerators and heat exchangers. Comprehensive prediction of fluid-solid interaction through this media can be obtained only by direct pore level simulation, a process which is time consuming and impractical for system level examination. Through the application of empirical correlations including the Darcy permeability and Forchheimer's inertial coefficient, the microscopic momentum equations governing fluid behavior within the porous structure can be recast as viable macroscopic governing equations. With these constitutive relationships, CFD can be an efficient and powerful tool for system modeling and optimization. The purpose of this study is to determine the hydrodynamic parameters of two mesh fillers relevant to miniature PTRs; stacked screens of 635 mesh stainless steel and 325 mesh phosphor-bronze wire cloth. Experimental setups were designed and fabricated to measure steady and oscillatory pressures and mass flow rates of the working fluid, research-grade helium. Hydrodynamic parameters for the two mesh fillers were determined for steady-state and steady periodic flow in both the axial and radial directions for a range of flow rates, operating frequencies and charge pressures. The effect of average pressure on the steady axial flow hydrodynamic parameters of other common PTR filler materials was also investigated. The determination of sample hydrodynamic parameters and their subsequent computational and experimental methodologies utilized are explained.
116

Desenvolvimento e caracterização de compósitos sanduíche para isolamento térmico

Sartori, Ana Paola 26 October 2009 (has links)
Um painel sanduíche consiste essencialmente em duas faces, podendo inclusive possuir reforços metálicos e um núcleo formado normalmente por um polímero celular. As faces deste tipo de painel podem estar unidas por um adesivo estrutural, ou por espuma rígida de poliuretano (PU) injetado diretamente sobre os substratos, quando a união ocorrerá naturalmente. A propriedade de maior relevância que o painel sanduíche deve ter para o transporte de cargas congeladas (0ºC a -30ºC) ou refrigeradas (7ºC a 1ºC) é a condutividade térmica (k). Dentro deste contexto o objetivo deste trabalho foi propor e caracterizar painéis sanduíches que possam ser utilizados em câmaras frigoríficas. Este trabalho apresenta as seguintes alternativas para compósito sanduíche: amostra 1 (PRFV/PU/PRFV); amostra 2 (AG/PU/AG); amostra 3 (Frisado/PU/PRFV); e amostra 4 (Al/PU/Al), onde PRFV é poliéster reforçado com fibra de vidro, PU é espuma rígida de poliuretano, AG é aço galvanizado, Frisado é alumínio frisado, e Al é alumínio. Estes painéis foram caracterizados quanto às propriedades físico-mecânicas, térmicas, morfológicas e custo. Foi possível concluir que o sistema (AG/PU/AG) mostrou o melhor custo versus desempenho dentre os compósitos propostos. / Submitted by Marcelo Teixeira (mvteixeira@ucs.br) on 2014-05-29T19:30:53Z No. of bitstreams: 1 Dissertacao Ana Paola Sartori.pdf: 3882091 bytes, checksum: c7530ac27f11dffba880ed97ee828f31 (MD5) / Made available in DSpace on 2014-05-29T19:30:53Z (GMT). No. of bitstreams: 1 Dissertacao Ana Paola Sartori.pdf: 3882091 bytes, checksum: c7530ac27f11dffba880ed97ee828f31 (MD5) / A sandwich panel consists essentially of two face sheets and may even have metal reinforcements and a core formed, usually by a cellular polymer. The faces of this type of panel may be joined by a structural adhesive or in cases where the core is a rigid polyurethane foam injected directly on the substrates the union will occur naturally. The most relevant property of the sandwich panels for the transport of frozen (0ºC a -30ºC) or chilled (7ºC a 1ºC) cargo is thermal conductivity (k). Within this context the objective of this work is to obtain and characterize sandwich panels which can be used in refrigerated chambers. This work presents four alternatives for composite sandwich, sample 1 (PRFV/PU/PRFV), sample 2 (AG/PU/AG), sample 3 (Al Crimpy/PU/PRFV) and sample 4 (Al /PU/Al), were PRFV is a glass fibre reinforced plastics, PU is a rigid polyurethane, AG is galvanized steel, Al Crimpy is crimpy aluminum and Al is aluminum. These composites were characterized by physicalmechanical, thermal, morphologic and cost. It could be concluded that the AG/PU/AG showed the best cost versus performance.
117

Desenvolvimento e caracterização de compósitos sanduíche para isolamento térmico

Sartori, Ana Paola 26 October 2009 (has links)
Um painel sanduíche consiste essencialmente em duas faces, podendo inclusive possuir reforços metálicos e um núcleo formado normalmente por um polímero celular. As faces deste tipo de painel podem estar unidas por um adesivo estrutural, ou por espuma rígida de poliuretano (PU) injetado diretamente sobre os substratos, quando a união ocorrerá naturalmente. A propriedade de maior relevância que o painel sanduíche deve ter para o transporte de cargas congeladas (0ºC a -30ºC) ou refrigeradas (7ºC a 1ºC) é a condutividade térmica (k). Dentro deste contexto o objetivo deste trabalho foi propor e caracterizar painéis sanduíches que possam ser utilizados em câmaras frigoríficas. Este trabalho apresenta as seguintes alternativas para compósito sanduíche: amostra 1 (PRFV/PU/PRFV); amostra 2 (AG/PU/AG); amostra 3 (Frisado/PU/PRFV); e amostra 4 (Al/PU/Al), onde PRFV é poliéster reforçado com fibra de vidro, PU é espuma rígida de poliuretano, AG é aço galvanizado, Frisado é alumínio frisado, e Al é alumínio. Estes painéis foram caracterizados quanto às propriedades físico-mecânicas, térmicas, morfológicas e custo. Foi possível concluir que o sistema (AG/PU/AG) mostrou o melhor custo versus desempenho dentre os compósitos propostos. / A sandwich panel consists essentially of two face sheets and may even have metal reinforcements and a core formed, usually by a cellular polymer. The faces of this type of panel may be joined by a structural adhesive or in cases where the core is a rigid polyurethane foam injected directly on the substrates the union will occur naturally. The most relevant property of the sandwich panels for the transport of frozen (0ºC a -30ºC) or chilled (7ºC a 1ºC) cargo is thermal conductivity (k). Within this context the objective of this work is to obtain and characterize sandwich panels which can be used in refrigerated chambers. This work presents four alternatives for composite sandwich, sample 1 (PRFV/PU/PRFV), sample 2 (AG/PU/AG), sample 3 (Al Crimpy/PU/PRFV) and sample 4 (Al /PU/Al), were PRFV is a glass fibre reinforced plastics, PU is a rigid polyurethane, AG is galvanized steel, Al Crimpy is crimpy aluminum and Al is aluminum. These composites were characterized by physicalmechanical, thermal, morphologic and cost. It could be concluded that the AG/PU/AG showed the best cost versus performance.

Page generated in 0.0827 seconds