11

Projeto e montagem de um sistema compacto de cogeração: aplicação da análise exergoeconômica

Reis, Joaquim Antônio dos [UNESP] 04 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-04Bitstream added on 2014-06-13T18:47:03Z : No. of bitstreams: 1 reis_ja_dr_guara.pdf: 3822491 bytes, checksum: c9fd5a88d775153288d737de07be90be (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho desenvolve o projeto, aqui entendido como a seleção das unidades que atendam às exigências de obtenção de eletricidade, calor e frio, e a montagem de um sistema de cogeração que usa um motor de pequeno porte associado a uma máquina de absorção e trocadores de calor que satisfarão tais exigências de uma maneira a mais econômica possível, isto é, otimizado em termos de custos. Aplicando-se um método de obtenção dos custos associados à exergia, cria-se um quadro de custos exergéticos para a obtenção de cada produto, e a soma de cada custo constitui o que chama-se de custo de manufatura exergética. O estudo demonstra que é possível aplicar esse método e identificar os pontos de deficiência de um sistema térmico como o mostrado e ,com isso, tomar medidas que venham a melhorar seu desempenho. Essa otimização física não se utiliza de conhecidos algoritmos de otimização matemática, utilizando-se de dados físicos e termodinâmicos medidos, O método permite identificar a forma operacional (basicamente a rotação do motor) que apresente os menores custos. A compreensão dos aspectos gerais da cogeração, das tecnologias envolvidas, com suas vantagens e desvantagens, torna possível aplicar a avaliação exergética associada a conceitos econômicos,e, com essa análise, tomar-se medidas que melhorem o desempenho do sistema em estudo. / This work develop the design of a cogeneration system with a small internal combustion engine coupled with an absorption refrigeration unit utilised in the production of a refrigeration effect, heating effect and electrical power generation with the utilization of exhaust waste heat, in a most possible economic way, i.e., optimized within limits of costs. By developing a method of costs associated to exergy, raises an exergetic costs for each unit, and the total costs is called manufacture exergetic cost. This study demonstrate that the appliance of this method identify the failures in the system and indicate where applies measures that improves its performance. This optimization do not utilizes mathematical algorithms, it is a physical optimization that use thermodynamics and physical data. The objective of this method is to identify the operational form that introduces the smaller cost. This compact cogeneration system have an internal combustion engine coupled with two heat exchangers and an absorption engine. The comprehension of general aspects of cogeneration technologies, its advantages and disadvantages turn possible to apply the exergetic evaluation associated with economic concepts to improve the performance of the system.
12

Projeto e montagem de um sistema compacto de cogeração : aplicação da análise exergoeconômica /

Reis, Joaquim Antônio dos. January 2006 (has links)
Resumo: Este trabalho desenvolve o projeto, aqui entendido como a seleção das unidades que atendam às exigências de obtenção de eletricidade, calor e frio, e a montagem de um sistema de cogeração que usa um motor de pequeno porte associado a uma máquina de absorção e trocadores de calor que satisfarão tais exigências de uma maneira a mais econômica possível, isto é, otimizado em termos de custos. Aplicando-se um método de obtenção dos custos associados à exergia, cria-se um quadro de custos exergéticos para a obtenção de cada produto, e a soma de cada custo constitui o que chama-se de custo de manufatura exergética. O estudo demonstra que é possível aplicar esse método e identificar os pontos de deficiência de um sistema térmico como o mostrado e ,com isso, tomar medidas que venham a melhorar seu desempenho. Essa otimização física não se utiliza de conhecidos algoritmos de otimização matemática, utilizando-se de dados físicos e termodinâmicos medidos, O método permite identificar a forma operacional (basicamente a rotação do motor) que apresente os menores custos. A compreensão dos aspectos gerais da cogeração, das tecnologias envolvidas, com suas vantagens e desvantagens, torna possível aplicar a avaliação exergética associada a conceitos econômicos,e, com essa análise, tomar-se medidas que melhorem o desempenho do sistema em estudo. / Abstract: This work develop the design of a cogeneration system with a small internal combustion engine coupled with an absorption refrigeration unit utilised in the production of a refrigeration effect, heating effect and electrical power generation with the utilization of exhaust waste heat, in a most possible economic way, i.e., optimized within limits of costs. By developing a method of costs associated to exergy, raises an exergetic costs for each unit, and the total costs is called manufacture exergetic cost. This study demonstrate that the appliance of this method identify the failures in the system and indicate where applies measures that improves its performance. This optimization do not utilizes mathematical algorithms, it is a physical optimization that use thermodynamics and physical data. The objective of this method is to identify the operational form that introduces the smaller cost. This compact cogeneration system have an internal combustion engine coupled with two heat exchangers and an absorption engine. The comprehension of general aspects of cogeneration technologies, its advantages and disadvantages turn possible to apply the exergetic evaluation associated with economic concepts to improve the performance of the system. / Orientador: José Luz Silveira / Coorientador: Edson Bazzo / Banca: Pedro Magalhães Sobrinho / Banca: Julio Santana Antunes / Banca: Jose Rui Camargo / Banca: Newton Galvão de Campos Leite / Doutor
13

An?lise te?rico-experimental do coeficiente de perfomance (COP) de um sistema de refrigera??o por jato-compress?o

Vargas, Luiz Carlos Pereira 26 April 2010 (has links)
Made available in DSpace on 2014-12-17T14:58:05Z (GMT). No. of bitstreams: 1 LuizCPV_DISSERT.pdf: 4145604 bytes, checksum: cc3f28e35e926d7f9d6bd3a0d675dcd3 (MD5) Previous issue date: 2010-04-26 / The use of waste heat of energy conversion equipment to produce a cooling effect, consists currently in a very interesting way of efficiency improvement of energy systems. The present research has as intention the theoretical and experimental study of a new intermittent refrigeration system ejector cycle characteristics, with use of waste heat. Initially, was doing a bibliographical survey about the vapor ejector refrigeration system technology. In the following stage was doing a simulation of the corresponding thermodynamic cycle, with preliminarily intention to evaluate the performance of the system for different refrigerants fluids. On the basis of the results of the simulation were selected the refrigerant fluid and developed an experimental group of benches of the refrigeration system considered, where pressure and temperature sensory had been inserted in strategical points of the refrigeration archetype and connected to a computerized data acquisition system for measure the refrigerant fluid properties in the thermodynamic cycle. The test results obtained show good agreement with the literature / A utiliza??o do calor residual de equipamentos para convers?o de energia para produzir frio, ? uma forma de melhoria da efici?ncia dos sistemas energ?ticos. A presente pesquisa destina-se ao estudo te?rico e experimental das caracter?sticas de um novo sistema de refrigera??o intermitente por jato-compress?o (ejetor) com uso de calor residual. Inicialmente, foi realizado um levantamento bibliogr?fico sobre a tecnologia de sistemas de refrigera??o por jato-compress?o. Na fase seguinte, investigou-se a concep??o do principal elemento da proposta de sistema de refrigera??o, o ejetor. A metodologia emp?rica utilizada no c?lculo do ejetor est? dispon?vel na literatura. Com o aux?lio do software EES (Engineering Equation Solver) foram realizados estudos (simula??es) para diferentes fluidos refrigerantes sint?ticos. O fluido refrigerante R141b apresentou as propriedades termodin?micas e de transporte necess?rios para o funcionamento eficaz do sistema proposto. Com base nos resultados da simula??o foi selecionado o fluido refrigerante e desenvolvida uma bancada experimental do sistema de refrigera??o proposto, onde sensores de press?o e temperatura foram inseridos em pontos estrat?gicos do prot?tipo de refrigera??o e conectados a um sistema de aquisi??o de dados computadorizado para medi??o das propriedades do fluido refrigerante no ciclo termodin?mico. Os resultados obtidos nos ensaios revelam boa concord?ncia com os encontrados na literatura
14

Návrh tepelného čerpadla voda-voda / Water to water heat pump design

Jašek, František January 2012 (has links)
First part of my diploma thesis contains theoretical description of compressor based heat pumps, refrigeration cycle, main components of refrigeration cycle and auxiliary equipment. Second part contains the heat pump WATER-WATER desing. It will be used for heat recovery from cogeneration units in heating plants.
15

[en] EVALUATION OF THE GAS LOAD INFLUENCE ON AN AUTOMOTIVE AIR CONDITIONING SYSTEM / [pt] AVALIAÇÃO DA INFLUÊNCIA DA CARGA DE GÁS EM UM SISTEMA DE CONDICIONAMENTO DE AR AUTOMOTIVO

RAFAEL PRUDENCIO SACSA DIAZ 07 July 2003 (has links)
[pt] A tecnologia automotiva moderna alcança progressos consideráveis tanto no aspecto mecânico como funcional, com esses avanços tecnológicos, o maior progresso foi feito na estrutura dos automóveis e dos sistemas de ar condicionado. O presente trabalho é desenvolvido considerando a importância da utilização de gás refrigerante, já que se tornou um assunto ambiental de grande importância pelo fato de ter um papel na destruição da camada de ozônio. Foi construída uma bancada experimental que consta de duas câmaras isoladas para a colocação do equipamento, instrumentos, dispositivos de medição e geração de carga térmica, em seguida foi montado um condicionador de ar automotivo composto por componentes originais do sistema de condicionamento de ar de um automóvel para simular funcionamentos, com a finalidade de avaliar os parâmetros de funcionamento afetados quando são utilizadas diferentes cargas de gás refrigerante. Foram realizados testes controlando a temperatura e umidade constantes no habitáculo automotivo (câmara 1), para variações de temperatura na câmara (2), da vazão mássica no sistema e variações de torque e velocidade, no sistema motor - compressor, com diferentes quantidades de gás refrigerante originando situações de insuficiência de carga, carga adequada e sobre carga. Para o controle da carga térmica dentro das câmaras foram utilizados controladores de potência e um software aplicativo. Os parâmetros de operação do equipamento foram obtidos e arquivados mediante um sistema automático de aquisição de dados. Os resultados experimentais mostraram o comportamento real do ciclo de refrigeração, a queda de pressão nas linhas de descarga e de sucção, assim como no condensador e no evaporador. Apresenta-se o sub-resfriamento do refrigerante na saída do condensador bem como o superaquecimento na sucção. Verifica-se uma tendência politrópica, no lugar do processo isentrópico do ciclo ideal. Esta divergência do ciclo faz com que a temperatura de descarga do compressor (T2) seja elevada. A carga de gás refrigerante exerce influência no desempenho de um sistema de condicionamento de ar e os resultados do presente trabalho concordaram bem com as expectativas teóricas do problema considerado. / [en] The modern automotive technology reaches considerable progress s in the mechanical aspect as in the functional, with these technological advances, the biggest progress was made in the structure of the automobiles and in the air conditioning systems. Considering the importance of the use of refrigerant, the present work is developed, because the refrigerant gas became a great importance ambient subject for its paper in the ozone layer destruction. An experimental bench was constructed; it consists of two isolated chambers, where equipment, instruments, devices of measurement and thermal load generation were installed. After that, an automotive air conditioner was mounted, made up of original components from an automobile air conditioning system to simulate operation, with the purpose to evaluate the operation parameters affected when using different refrigerant loads. Tests with constant temperature and humidity in the simulated automotive chamber (1) for variations of chamber (2) temperature, of mass outflow in the system and variations of torque and speed in the motor-compressor system were performed with different refrigerating amounts creating situations of insufficient load, adequate load and over load. For the chambers thermal load controlling, power controlling and appropriate software were used. The equipment operational parameters had been gotten and filed by means of an automatic data acquisition system. The experimental results had shown the real behavior of the refrigeration cycle, the pressure drop in the discharge and suction lines, as well as in the condenser and the evaporator. Also the refrigerant sub-cooling in the exit of the condenser, the gas overheating in the suction, the polytrophic trend instead of the ideal cycle isentropic process was observed. This divergence from the ideal cycle makes the discharge compressor temperature (T2) was higher. The refrigerant gas charge influences the performance of an air conditioning system and the present work results agreed well with the theoretical expectations for the considered problem.