• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Previsão de carga multinodal utilizando redes neurais de regressão generalizada

Nose Filho, Kenji [UNESP] 16 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-16Bitstream added on 2014-06-13T18:08:28Z : No. of bitstreams: 1 nosefilho_k_me_ilha.pdf: 1257365 bytes, checksum: f5d5c54cd646c650661ad9f32be4a6a4 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Neste trabalho, dá-se ênfase à previsão de carga multinodal, também conhecida como previsão de carga por barramento. Para realizar esta demanda, há necessidade de dispor de uma técnica que proporcione a precisão desejada, seja confiável e de baixo tempo de processamento. O conhecimento prévio das cargas locais é de extrema importância para o planejamento e operação dos sistemas de energia elétrica. Para realizar a previsão de carga multinodal foram empregadas duas metodologias, uma que prevê as cargas individualmente e outra que utiliza as previsões dos fatores de participação e a previsão de carga global. O principal objetivo deste trabalho é elaborar um modelo de previsor de carga de curto prazo, genérico e que pode ser aplicado na previsão de carga multinodal. Para tanto, utilizou-se redes neurais de regressão generalizada (GRNN), cujas entradas são compostas de variáveis exógenas globais e de cargas locais, sem a necessidade da inclusão de variáveis exógenas locais. Ainda, projetou-se uma nova arquitetura de rede neural artificial, baseada na GRNN, além de propor um procedimento para a redução do número de entradas da GRNN e um filtro para o pré-processamento do banco de dados de treinamento. Os dados, para testar as metodologias e as redes neurais artificiais, são referentes a um subsistema de distribuição de energia elétrica da Nova Zelândia composto por nove subestações / In this work, it is emphasized the multi-nodal load forecast, also known as bus load forecast. To perform this demand, there it is necessary a technique that is precise, trustable and has a short-time processing. The previous knowledge of the local loads is of extreme importance to the planning and operation of the electrical power and energy systems. To perform the multi-nodal load forecast is employed two different methodologies, one that forecast the loads individually and another that uses the participation factors forecasts and the global load forecast. The main objective of this work is to elaborate a generic model of a short-term load forecaster, which can be applied to the multi-nodal load forecast. For this, it was used general regression neural networks (GRNN), with inputs based on external global factors and local loads, without the need of external local factors. Still, it was developed a new architecture of an artificial neural network based on a GRNN and proposed a procedure to reduce the number of input variables of the GRNN and a filter for preprocessing the training data. The dataset, to test the methodologies and the artificial neural networks, refers to a New Zealand electrical distribution subsystem composed of nine substations
2

Estimadores de frequência aplicados a sistemas elétricos de potência / Frequency estimators applied to electrical power system

Marchesan, Gustavo 08 March 2013 (has links)
The frequency estimation is a problem widely studied in many fields including electric power systems. Several methods have been proposed for this purpose, and most of them perform well when the signal is not distorted by harmonics or noises. This paper presents two new methods based on Artificial Neural Networks for frequency estimation. Both use Clarck s transform to generate a phasor that represent the system s signal. In the first methodology this phasor is normalized and feeds the Generalized Regression Neural Network, that ponders the values. At the end it s obtained a phasor where noisy and harmonics are attenuated. The neural network output is then used to calculate the electrical system frequency. Otherwise, the second methodology uses the Adaptive Linear Neural Network. This work tested also various methodologies of frequency estimation proposed in other knowledge fields such as radar, sonar, communications, biomedicine and aviation however with electrical power systems signals. These methods are: Lavopa (proposed by Lavopa et al. 2007), Quinn (proposed by Quinn, 1994), Jacobsen (proposed by Jacobsen e Kootsookos, 2007), Candan (proposed by Candan, 2011), Macleod (proposed by Macleod, 1998), Aboutanios (proposed by Aboutanios, 2004), Mulgrew (proposed by Aboutanios e Mulgrew, 2005), Ferreira (proposed by Ferreira 2001) e DPLL (proposed by Sithamparanathan, 2008). With the exception of DPLL the remaining methods are based on the Discrete Fourier Transform and seek the spectrum frequency peak to than find the fundamental frequency. The nine methodologies are compared with the proposed methods and with the commonly techniques used or studied for electric power systems. Tests include noisy signals, harmonics, sub-harmonics, frequency variations on step, ramp and sinusoidal, also variations on voltage and phase are considered. The tests also include a simulated signal where a load block is inserted and immediately after removed from the system. At the end a comparison is made between the techniques, been able to point each technique advantage and disadvantage trough the comparison identify the best methods to be applied on electrical power systems. / A estimação de frequência é um problema muito estudado em diversas áreas, dentre elas a dos sistemas elétricos de potência. Inúmeras metodologias foram propostas para esse fim, sendo que a maioria delas apresenta bom desempenho quando o sinal não está distorcido por componentes harmônicas ou ruídos. Este trabalho propõe duas novas metodologias fundamentadas em Redes Neurais Artificiais, de modo a estimar a frequência. Elas utilizam a transformada de Clarck para gerar um fasor que representa o sinal trifásico do sistema. Na primeira metodologia, esse fasor é normalizado e alimenta a Rede Neural de Regressão Generalizada, que faz a ponderação dos valores. Ao final, obtém-se um fasor em que ruídos e harmônicas são atenuados. A saída da rede neural é, então, utilizada para o cálculo da frequência do sistema elétrico. A segunda metodologia utiliza a Rede Neural Linear Adaptativa. Neste trabalho, também são testadas, para uso em sistemas elétricos de potência, diversas metodologias propostas em outras áreas de conhecimento, tais como radar, sonar, comunicação, biomedicina e aviação. São elas: Lavopa (proposta por Lavopa et al. 2007), Quinn (proposta por Quinn, 1994), Jacobsen (proposta por Jacobsen e Kootsookos, 2007), Candan (proposta por Candan, 2011), Macleod (proposta por Macleod, 1998), Aboutanios (proposta por Aboutanios, 2004), Mulgrew (proposta por Aboutanios e Mulgrew, 2005), Ferreira (proposta por Ferreira 2001) e DPLL (proposta por Sithamparanathan, 2008). Com exceção da DPLL, os demais métodos são fundamentados na transformada discreta de Fourier e buscam encontrar o pico do espectro de frequências, para, então, encontrar a frequência fundamental. As nove metodologias são comparadas juntamente com os métodos propostos e as técnicas já comumente usadas ou estudadas para sistemas elétricos. Os testes incluem sinais com ruídos, harmônicas, sub-harmônicas, variações de frequência em degrau, rampa e senoidal, variações de fase e tensão em degrau. Os testes ainda incluem um sinal provindo de simulação em que um bloco de carga é inserido e logo após retirado do sistema. Ao final é realizada uma comparação entre as técnicas, sendo possível identificar as vantagens e desvantagens de cada uma e, assim, indicar as melhores a serem usadas em sistemas elétricos de potência.

Page generated in 0.1168 seconds