• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 444
  • 9
  • 8
  • Tagged with
  • 470
  • 273
  • 124
  • 79
  • 68
  • 60
  • 56
  • 53
  • 51
  • 49
  • 45
  • 44
  • 42
  • 41
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Qualificação de calcários brasileiros quanto à absorção de SO2 em leito fluidizado para condições típicas de combustão de carvão / not available

Camargo, Fernando de Lima 16 April 2001 (has links)
As grandes taxas de consumo de calcário são uma característica problemática em relação à absorção de enxofre na combustão de carvão em leito fluidizado. O conhecimento da conversão e das taxas de reação é um fator chave para a redução do consumo, permitindo uma utilização mais eficiente e uma melhor seleção dos absorventes. Neste trabalho a conversão e o coeficiente da taxa de reação global para a absorção de enxofre por diferentes calcários são determinados num reator de leito fluidizado de escala reduzida. O reator é uma coluna de 160 mm de diâmetro interno, utilizando areia como material do leito, e fluidizado por ar pré-aquecido em 750 e 850ºC. Uma fração de SO2 é adicionada ao ar de fluidização, e bateladas de calcário são alimentadas no leito para a remoção de enxofre. O tamanho médio das partículas de areia e de calcário é de 545 &#956m. As temperaturas, o tamanho das partículas e a fração de SO2 no gás são típicos do processo de combustão de carvão em leito fluidizado. Quando as bateladas de calcário são alimentadas no leito previamente aquecido, as concentrações transientes de saída de SO2, CO2 e O2 são monitoradas continuamente no tempo com a temperatura do processo. Cinco calcários de três regiões diferentes foram testados, sendo dois calcíticos, dois dolomíticos e um magnesiano. Os resultados mostraram que o calcário dolomítico, relativamente mais jovem em relação a sua idade geológica, foi o que apresentou uma melhor eficiência para a remoção de SO2. / The high rates of consumption of limestone is a problematic feature regarding sulfur absorption in coal fluidized bed combustion. The knowledge of conversion and reaction rates is a key factor towards reducing that consumption, allowing a more efficient utilization and a better selection of absorbents. In this work the conversion and the global reaction rate coefficient for sulfur absorption by different limestones are determined in a bench scale fluidized bed reactor. The reactor is a 160 mm internal diameter column using silica sand as bed material, fluidized by pre-heated air at 750°C and 850°C. A fraction of SO2 is added to the fluidization air, and batches of limestone are fed to the bed to perform sulfur removal. The mean particle size of both silica sand and limestone is of 545 &#956m. The considered temperatures, particle size and fraction of SO2 in the gas of the bed are typical of the coal fluidized bed combustion process. As the batches of limestone are fed to the previously heated bed, the exit transient concentrations of SO2, CO, CO2 and O2 are continuously recorded alongside with the process temperature. Five different limestones were tested, including two calcitic, two dolomitic and one magnesian. The results show that the dolomitic limestone, relatively younger regarding its geological age, presented a better efliciency for SO2 removal.
12

Avaliação do efeito de variáveis de processo na lixiviação das cinzas de caldeira de recuperação em indústria de papel e celulose

BARROS, E. L. 22 March 2018 (has links)
Made available in DSpace on 2018-08-01T23:29:12Z (GMT). No. of bitstreams: 1 tese_11912_75 - Eduardo_Versao_Final.pdf: 4543218 bytes, checksum: ea084f9050c76600cbf0ef5516e84b40 (MD5) Previous issue date: 2018-03-22 / Os elementos não processáveis (NPE´s) na indústria de papel e celulose, particularmente o cloro (Cl-) e o potássio (K+), eventualmente se acumulam no ciclo do licor na etapa de recuperação química. Esse acúmulo geralmente leva a incrustação e corrosão dentro da caldeira de recuperação. Para superar tais problemas, um sistema de lixiviação de cinzas é tipicamente empregado para remover Cl-/K+ e recuperar Na+/(SO4)-2 das cinzas. Neste contexto, esta pesquisa propõe avaliar os efeitos da temperatura, da concentração da lama e do pH sobre a eficiência de separação em um sistema de lixiviação em escala laboratorial utilizando cinzas de caldeira de recuperação de uma fábrica de celulose e papel. Conforme reportado pela literatura, o resultado revela que a concentração tem o efeito mais significativo sobre as variáveis de resposta, enquanto que o pH - não mencionado na literatura - também tem um efeito significativo. As condições operacionais ótimas (84% de eficiência de recuperação de sulfato e 97% de eficiência de remoção de cloreto) podem ser alcançadas a 60ºC, 50% de concentração na lama e pH 9,0.
13

Desenvolvimento de novos materiais de carbono mesoporosos para a ozonização de poluentes orgânicos

Fonseca, Carla Alexandra Orge January 2008 (has links)
Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2008
14

Avaliação da eficiência da eletrodiálise na remoção de cloretos

Macedo, Thais Helena January 2018 (has links)
A crescente demanda de água compromete rios, lagos e reservatórios. Tecnologias para tratamento de efluentes que permitam a reutilização da água vêm se tornando cada vez mais necessárias. Entre os contaminantes, o cloreto, por suas propriedades corrosivas, caracteriza um desafio para a utilização da água em diversas aplicações. Tratamentos físicoquímicos não removem o cloreto a níveis adequados, sendo assim, tecnologias alternativas, como a eletrodiálise, devem ser estudadas para garantir operação com alta eficiência e inserir estas alternativas mais significativamente no Brasil. A avaliação do transporte iônico está relacionada aos fenômenos que ocorrem na interface membrana-solução. Neste trabalho foi avaliada a eficiência de eletrodiálise na remoção de cloreto por uma membrana aniônica heterogênea comercial (HDX-200). Soluções de NaCl, NiCl2, CaCl2 e AlCl3 foram avaliadas, a fim de verificar o efeito dos co-íons no transporte de cloreto. Os diagramas de especiação química das soluções indicaram a necessidade de ajustes de pH anteriores ao tratamento e trouxeram informações sobre a ocorrência de complexos. Após a determinação da corrente limite para cada solução, estas foram tratadas e a eficiência do tratamento foi avaliada. A corrente limite foi mais elevada para a solução de NaCl, onde a extração percentual de cloreto foi maior que às demais soluções, indicando que o raio iônico hidratado do co-íon influencia no transporte do contra-íon cloreto. Verificou-se a ocorrência de duas correntes limites para a solução NiCl2, que podem estar associadas à uma fração de sal não dissociada e a variações de pH na interface membrana-solução. Para os sais de níquel e alumínio, uma baixa eficiência de corrente foi verificada e pode estar relacionada à ocorrência de precipitação. Parâmetros como o peso molecular e raio iônico hidratado do co-íon (cátion), além da força de Coulomb para cada sal, influenciaram no transporte de cloreto e dos co-íons. Avaliações anteriores ao tratamento por eletrodiálise, pelo diagrama de especiação química das soluções, e a determinação da corrente limite para cada solução, pode garantir melhor eficiência do processo de tratamento. / The increasing water demand jeopardizes rivers, lakes and reservoirs. Technologies for the treatment of effluents which allow water reuse have become more and more necessary. Among the contaminants there is the chloride, which due to its corrosive properties characterizes a challenge in water reuse in several applications. Physico-chemical treatments do not remove sufficiently the chloride; thus, alternative technologies, such as electrodialysis, must be studied in order to increase its efficiency and insert it more significantly in Brazil. The evaluation of ionic transport is related to the phenomena that occur on the membrane-solution interface. The efficiency of electrodialysis in the removal of chloride through a commercial heterogeneous anionic membrane (HDX-200) was evaluated in this study. NaCl, NiCl2, CaCl2 and AlCl3 solutions were assessed in order to verify the co-ions effects on chloride transport. The chemical speciation diagrams of the solutions indicated the need to adjust pH previously to treatment and provided information about the occurrence of complexes. After determining the limiting current for each solution, these were treated, and treatment efficiency was evaluated. The NaCl solution presented the highest limiting current, in which the percentual extraction of chloride was higher than to the other solutions indicating that the hydrated ionic radius of the co-ion influences the transport of the counterion chloride. The occurrence of two limiting currents for the NiCl2 solution was verified, which can be related to a non-dissociated fraction of salt and pH variations on the membrane-solution interface. A low efficiency of current was verified for nickel and aluminum salts, and it may be associated to precipitation occurrence. Molecular weight and the hydrated ionic radius of the co-ions (cations) besides the Coulomb force for each salt influenced chloride and co-ions transport. Previous evaluation of electrodialysis treatment, with diagrams of chemical speciation of the solutions and determination of limiting current for each solution may ensure the best efficiency in the treatment process.
15

Utilização do resíduo do processamento do camarão na adsorção de ânions

Borges, Adriana Moret January 2002 (has links)
o objetivo do presente trabalho foi desenvolver um material adsorvente alternativo de íons sulfato a partir de um resíduo industrial abundante e renovável. Apesar da baixa toxicidade, concentrações elevadas destes íons inviabilizam o reciclo, o reuso e o descarte de efluentes. Para tanto, foi utilizado o resíduo do processamento de camarão que, após etapas de desmineralização, desproteinização e desacetilação, forneceu materiais quitinosos em forma de flakes com diferentes graus de desacetilação (GD), tendo sido selecionada a quitina com GD da ordem de 25% como sólido adsorvente. Os estudos de adsorção de íons sulfàto, realizados em frascos agitados com soluções sintéticas, mostraram valores de remoção da ordem de 92%, correspondente a uma capacidade de adsorção de 3,2 mEq.g-l. Estes resultados foram obtidos com o emprego de uma razão sólido/SO/- de 8,5 mg.mg-I, tempo de contato de 15 minutos e um pH de equilíbrio de 4,3 :t 0,3. Além da adsorção de íons sulfato, os resultados revelaram que quiti.na adsorve também íons molibdato (82% em 15 minutos e 92% em 60 minutos) sem qualquer interferência na adsorção de íons sulfato, fato considerado relevante no tratamento de efluentes de mineração de cobre e molibdênio. A adsorção dos íons sulfàto por quiti.na ocorre através do mecanismo de fisissorção por atração eletrostática, seguindo um modelo cinético de pseudo-segunda ordem, onde as etapas de transferência de massa dos íons não foram limitantes. A reversibilidade da adsorção, uma das características de processos que envolvem interações eletrostáticas, foi confirmada através de estudos de dessorção utilizando soluções de NaOH e permitiram verificar a possibilidade de regeneração do adsorvente. A cinética de adsorção em coluna de percolação, para uma granulometria de sólido e pH inicial do meio inferiores, foi maior do que a obtida no sistema de frascos agitados. Por outro lado, a capacidade de adsorção obtida a partir da curva de saturação em coluna de percolação foi praticamente a mesma obtida no sistema de :fIascosagitados. Nos estudos com efluentes industriais, o desempenho da quitina foi praticamente similar ao obtido com efluentes sintéticos, tendo sido atingidos elevados percentuais de adsorção. Estes resultados confirmam o potencial deste bioadsorvente para o tratamento de efluentes contendo altas concentrações de íons sulfato. Finalmente, são discutidas as considerações gerais do processo no contexto geral do tratamento de efluentes líquidos contendo compostos inorgânicos.
16

A transferência de empregados no processo de descentralização industrial: casos de empresas francesas

Ramirez, Elena Lucia Vivas 07 June 1991 (has links)
Made available in DSpace on 2010-04-20T20:17:19Z (GMT). No. of bitstreams: 0 Previous issue date: 1991-06-07T00:00:00Z / Tem por objetivo geral pesquisar as práticas de empresas cuja descentralização tenha tido uma transferência bem sucedida no que se refere aos problemas e aspectos vinculados às condições de vida afetadas pela mudança dos indivíduos transferidos.
17

Estudo da remoção de cor de efluente têxtil por eletrocoagulação / Study of the color removal of textile wastewater by electrocoagulation

Pessoa, Germana de Paiva 27 June 2008 (has links)
PESSOA, G. P. Estudo da remoção de cor de efluente têxtil por eletrocoagulação. 2008. 69 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2008. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-10T19:51:39Z No. of bitstreams: 1 2008_dis_gppessoa.pdf: 837488 bytes, checksum: 88f35370f1235a81e6632ee1cb18114c (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-11T16:22:54Z (GMT) No. of bitstreams: 1 2008_dis_gppessoa.pdf: 837488 bytes, checksum: 88f35370f1235a81e6632ee1cb18114c (MD5) / Made available in DSpace on 2016-05-11T16:22:54Z (GMT). No. of bitstreams: 1 2008_dis_gppessoa.pdf: 837488 bytes, checksum: 88f35370f1235a81e6632ee1cb18114c (MD5) Previous issue date: 2008-06-27 / The textile effluent color resultant from dyes polymeric structures is a problem for textile industries. Amongst the treatment techniques for this type of effluent, it is emphasized the electrocoagulation (EC), which consists of a physicochemical technique applied for either color or organic pollutants removal. In this work, three stages of the EC process, in batch, for dye color removal were assessed. In the first stage (synthetic effluent and primary aluminum electrodes), the reactive dye Remazol Blue RR was used and the effect of operational parameters such as electric current density, initial solution pH, electrolysis time, initial dye concentration, solution conductivity, chemical oxygen demand (COD) and the energy consumption was verified, reaching a color removal of 98% and 100%, for the treatment time of 20 and 40 minutes, respectively. In the optimized operational conditions, 98% of color removal and 97 % of DQO removal were obtained, resulting a process cost of R$ 2,62 per m3 of treated effluent. In the second stage (synthetic effluent and electrodes made from cans), a color removal of 90% and 95%, for the treatment time of 20 and 30 minutes, was verified, respectively. It is important to mention that, for the time of 20 minutes, the operational cost was R$ 0,95, whereas, for 30 minutes, was R$ 1,42 per m3 of treated effluent. In the third stage, real textile effluent from Benatêxtil, a textile industry located in Fortaleza city – Ceará, and primary aluminum electrodes were used. The best result for color removal was 77,63%, with dilution of 5%, treatment time of 30 minutes and initial pH 3,0. The calculated energy cost for this stage was of R$ 2,01 per m3 of treated effluent. In this study it was possible to verify that the electrocoagulation process can be efficient in the color removal of a synthetic textile effluent composed of dyes, but, for the real textile effluent without a previous treatment, it is necessary to dilute it due to its high dye concentration and conductivity. / A cor dos efluentes têxteis oriunda das estruturas poliméricas dos corantes é um problema para as indústrias têxteis. Dentre as técnicas para o tratamento desse tipo de efluente, ressalta-se a eletrocoagulação (EC), a qual consiste em uma técnica físico-química aplicada tanto para remoção de cor como para poluentes orgânicos. Neste trabalho, avaliaram-se, em sistema de batelada, três etapas do processo EC na remoção de cor de corantes. Na primeira etapa (efluente sintético e eletrodos de alumínio primário) foi utilizado o corante reativo, Remazol Blue RR, onde verificou-se o efeito dos parâmetros operacionais, tais como: densidade de corrente, o pH inicial da solução, tempo de eletrólise, concentração inicial do corante, condutividade da solução, demanda química de oxigênio (DQO) e o consumo de energia, obtendo-se uma remoção de cor de 98% e 100%, em um tempo de tratamento de 20 e 40 minutos, respectivamente. Nas condições operacionais otimizadas, foram obtidos 98% remoção de cor e 97% de DQO, sendo o custo do processo de R$ 2,62 por m3 de efluente tratado. Na segunda etapa (efluente sintético e eletrodos de latinhas recicláveis), verificou-se uma remoção de cor de 90% e 95% para o tempo de tratamento de 20 e 30 minutos, respectivamente. Ressalta-se que, para o tempo de 20 minutos, o custo operacional foi de R$ 0,95, enquanto que, para 30 minutos foi de R$ 1,42 por m³ de efluente tratado. Na terceira etapa utilizou-se efluente têxtil real, proveniente da indústria Benatêxtil localizada na cidade de Fortaleza - Ceará e eletrodo de alumínio primário. O melhor resultado de remoção de cor foi de 77,63%, com diluição de 5%, tempo de tratamento de 30 minutos e pH inicial 3,0. O custo energético calculado para essa etapa foi de R$ 2,01 por m3 de efluente tratado. Nesse estudo foi possível verificar que o processo de eletrocoagulação pode ser eficiente na remoção de cor de um efluente sintético constituído por corantes, mas que, para o efluente têxtil real sem nenhum tratamento prévio faz-se necessário a diluição do mesmo, devido à alta concentração do corante e elevada condutividade.
18

Avaliação da eficiência da eletrodiálise na remoção de cloretos

Macedo, Thais Helena January 2018 (has links)
A crescente demanda de água compromete rios, lagos e reservatórios. Tecnologias para tratamento de efluentes que permitam a reutilização da água vêm se tornando cada vez mais necessárias. Entre os contaminantes, o cloreto, por suas propriedades corrosivas, caracteriza um desafio para a utilização da água em diversas aplicações. Tratamentos físicoquímicos não removem o cloreto a níveis adequados, sendo assim, tecnologias alternativas, como a eletrodiálise, devem ser estudadas para garantir operação com alta eficiência e inserir estas alternativas mais significativamente no Brasil. A avaliação do transporte iônico está relacionada aos fenômenos que ocorrem na interface membrana-solução. Neste trabalho foi avaliada a eficiência de eletrodiálise na remoção de cloreto por uma membrana aniônica heterogênea comercial (HDX-200). Soluções de NaCl, NiCl2, CaCl2 e AlCl3 foram avaliadas, a fim de verificar o efeito dos co-íons no transporte de cloreto. Os diagramas de especiação química das soluções indicaram a necessidade de ajustes de pH anteriores ao tratamento e trouxeram informações sobre a ocorrência de complexos. Após a determinação da corrente limite para cada solução, estas foram tratadas e a eficiência do tratamento foi avaliada. A corrente limite foi mais elevada para a solução de NaCl, onde a extração percentual de cloreto foi maior que às demais soluções, indicando que o raio iônico hidratado do co-íon influencia no transporte do contra-íon cloreto. Verificou-se a ocorrência de duas correntes limites para a solução NiCl2, que podem estar associadas à uma fração de sal não dissociada e a variações de pH na interface membrana-solução. Para os sais de níquel e alumínio, uma baixa eficiência de corrente foi verificada e pode estar relacionada à ocorrência de precipitação. Parâmetros como o peso molecular e raio iônico hidratado do co-íon (cátion), além da força de Coulomb para cada sal, influenciaram no transporte de cloreto e dos co-íons. Avaliações anteriores ao tratamento por eletrodiálise, pelo diagrama de especiação química das soluções, e a determinação da corrente limite para cada solução, pode garantir melhor eficiência do processo de tratamento. / The increasing water demand jeopardizes rivers, lakes and reservoirs. Technologies for the treatment of effluents which allow water reuse have become more and more necessary. Among the contaminants there is the chloride, which due to its corrosive properties characterizes a challenge in water reuse in several applications. Physico-chemical treatments do not remove sufficiently the chloride; thus, alternative technologies, such as electrodialysis, must be studied in order to increase its efficiency and insert it more significantly in Brazil. The evaluation of ionic transport is related to the phenomena that occur on the membrane-solution interface. The efficiency of electrodialysis in the removal of chloride through a commercial heterogeneous anionic membrane (HDX-200) was evaluated in this study. NaCl, NiCl2, CaCl2 and AlCl3 solutions were assessed in order to verify the co-ions effects on chloride transport. The chemical speciation diagrams of the solutions indicated the need to adjust pH previously to treatment and provided information about the occurrence of complexes. After determining the limiting current for each solution, these were treated, and treatment efficiency was evaluated. The NaCl solution presented the highest limiting current, in which the percentual extraction of chloride was higher than to the other solutions indicating that the hydrated ionic radius of the co-ion influences the transport of the counterion chloride. The occurrence of two limiting currents for the NiCl2 solution was verified, which can be related to a non-dissociated fraction of salt and pH variations on the membrane-solution interface. A low efficiency of current was verified for nickel and aluminum salts, and it may be associated to precipitation occurrence. Molecular weight and the hydrated ionic radius of the co-ions (cations) besides the Coulomb force for each salt influenced chloride and co-ions transport. Previous evaluation of electrodialysis treatment, with diagrams of chemical speciation of the solutions and determination of limiting current for each solution may ensure the best efficiency in the treatment process.
19

Utilização do resíduo do processamento do camarão na adsorção de ânions

Borges, Adriana Moret January 2002 (has links)
o objetivo do presente trabalho foi desenvolver um material adsorvente alternativo de íons sulfato a partir de um resíduo industrial abundante e renovável. Apesar da baixa toxicidade, concentrações elevadas destes íons inviabilizam o reciclo, o reuso e o descarte de efluentes. Para tanto, foi utilizado o resíduo do processamento de camarão que, após etapas de desmineralização, desproteinização e desacetilação, forneceu materiais quitinosos em forma de flakes com diferentes graus de desacetilação (GD), tendo sido selecionada a quitina com GD da ordem de 25% como sólido adsorvente. Os estudos de adsorção de íons sulfàto, realizados em frascos agitados com soluções sintéticas, mostraram valores de remoção da ordem de 92%, correspondente a uma capacidade de adsorção de 3,2 mEq.g-l. Estes resultados foram obtidos com o emprego de uma razão sólido/SO/- de 8,5 mg.mg-I, tempo de contato de 15 minutos e um pH de equilíbrio de 4,3 :t 0,3. Além da adsorção de íons sulfato, os resultados revelaram que quiti.na adsorve também íons molibdato (82% em 15 minutos e 92% em 60 minutos) sem qualquer interferência na adsorção de íons sulfato, fato considerado relevante no tratamento de efluentes de mineração de cobre e molibdênio. A adsorção dos íons sulfàto por quiti.na ocorre através do mecanismo de fisissorção por atração eletrostática, seguindo um modelo cinético de pseudo-segunda ordem, onde as etapas de transferência de massa dos íons não foram limitantes. A reversibilidade da adsorção, uma das características de processos que envolvem interações eletrostáticas, foi confirmada através de estudos de dessorção utilizando soluções de NaOH e permitiram verificar a possibilidade de regeneração do adsorvente. A cinética de adsorção em coluna de percolação, para uma granulometria de sólido e pH inicial do meio inferiores, foi maior do que a obtida no sistema de frascos agitados. Por outro lado, a capacidade de adsorção obtida a partir da curva de saturação em coluna de percolação foi praticamente a mesma obtida no sistema de :fIascosagitados. Nos estudos com efluentes industriais, o desempenho da quitina foi praticamente similar ao obtido com efluentes sintéticos, tendo sido atingidos elevados percentuais de adsorção. Estes resultados confirmam o potencial deste bioadsorvente para o tratamento de efluentes contendo altas concentrações de íons sulfato. Finalmente, são discutidas as considerações gerais do processo no contexto geral do tratamento de efluentes líquidos contendo compostos inorgânicos.
20

Remoção de algas de efluentes de lagoa de estabilização por meio de filtração vertical ascendente em pedregulho e brita nº2 / Algae removal of wastewater stabilization pond by vertical upflow roughing filters

Menezes, Olga Rubênia da Silva Caminha de 10 June 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-10-23T16:32:20Z No. of bitstreams: 1 2014_OlgaRubêniadaSilvaCaminhadeMenezes.pdf: 2448261 bytes, checksum: 4e109a8a6eb6567d48a2d2ed9db955e5 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-26T13:48:54Z (GMT) No. of bitstreams: 1 2014_OlgaRubêniadaSilvaCaminhadeMenezes.pdf: 2448261 bytes, checksum: 4e109a8a6eb6567d48a2d2ed9db955e5 (MD5) / Made available in DSpace on 2014-11-26T13:48:54Z (GMT). No. of bitstreams: 1 2014_OlgaRubêniadaSilvaCaminhadeMenezes.pdf: 2448261 bytes, checksum: 4e109a8a6eb6567d48a2d2ed9db955e5 (MD5) / A utilização de filtros com meios filtrantes diversos como alternativa de pós-tratamento de efluentes de lagoas de estabilização, com os custos e simplicidade compatível aos das lagoas, vêm sendo estudada desde a década de 1970. Apesar disso, sua aplicação à situações específicas demandam estudos detalhados sobre os parâmetros de projetos dos filtros. Assim, este trabalho teve como objetivo avaliar a influência da distribuição granulométrica e da taxa de filtração na eficiência de filtros de escoamento vertical ascendente na remoção de algas de efluentes de lagoas de estabilização de alta taxa. Osistema piloto utilizado no estudo consistia em dois filtros com escoamento ascendente,sendo um filtro preenchido com pedregulho de granulometria decrescente (FP) e o outro preenchido com brita nº 2 (FB), ambos com espessura de 1,5m, alimentados com e fluente de lagoa de estabilização de alta taxa da ETE Paranoá, Brasília. Os filtros operaram com taxa de filtração de 3 e 1 m3/m2.dia (2 e 0,7 m3/m3.dia), em duas fases experimentais. Odesempenho dos filtros foi avaliado a partir dos dados de Clorofila-a, DQO e SST, tendocomo parâmetros complementares a turbidez, o fósforo, o nitrogênio (amoniacal, nitrito enitrato) e o pH. Esporadicamente, foi realizada a quantificação do fitoplâncton presente nalagoa e nos filtros. Apesar dos filtros FP e FB demonstrarem potencial para redução deSST, DQO e clorofila-a com uso da taxa de filtração de 3 m3/m2.dia, as eficiências deremoção foram baixas. A eficiência de remoção de clorofila-a, DQO e SST aumentou significativamente nos dois filtros quando a taxa de filtração de 1 m3/m2.dia foi utilizada.Os valores médios de remoção de clorofila-a foram de 61% e 71%, respectivamente no FPe no FB e a remoção média de DQO no FP foi de 37% e no FB de 41%. A remoção de SST aumentou cerca de 40% da primeira para a segunda taxa. De modo geral, o FB se mostrou mais eficiente do que o FP, porém o teste de Mann-Whitney indicou não haver diferenças significativas entre os filtros. _____________________________________________________________________________ ABSTRACT / The use of roughing filters with different media as an alternative post-treatment ofwastewater stabilization ponds, with the cost and simplicity compatible with the lagoons,has been studied since 1970 decade. Nevertheless, its use for a specific effluent demandsdetailed investigation about the design parameters of the filters. In this context, this studyaimed to evaluate the influence of the media size distribution and filtration rate on theefficiency of upflow vertical roughing filters in removing algae of high rate stabilizationpond. The pilot system used consisted of two upflow filters fed with effluent of high ratestabilization pond of Paranoá WWTP, Brasilia - Brazil. A 1.5m media layer was used inboth filters, however, one filter was filled with a five sub-layer of decreasing grain size inthe range of 50 to 6.4 mm (FP) and other filter was filled with grain size in the range of 19-50 mm (FB). The filters were operated with a filtration rate of 3 and 1 m3/m2.day (2 e 0.7m3/m3.day) in two experimental phases. The performance of each filter was estimatedbased on Chlorophyll-a, COD and TSS data. Turbidity, phosphorous, nitrogen(ammonium, nitrite and nitrate) and pH were used as complementary parameters.Occasionally, quantification of phytoplankton in the pond and filters was performed.Although the FP and FB filters operating with filtration rate of 3 m3/m2.day have shownpotential to reduce TSS, COD and chlorophyll-a, the removal efficiencies were low. Theremoval efficiency of chlorophyll-a, COD and TSS was significantly increased when filterswere operated with the lower filtration rate, 1 m3/m2.day. The average removal ofchlorophyll-a was 61% and 71%, respectively, for FP and FB. The FP was able to remove,in average, 37% of COD and the FB 42% of COD. The TSS removal increased about 40%from first to second filtration rate. In general, FB was slightly more efficient than FP,however, the Mann-Whitney hypothesis test showed no significant difference between thetwo filters.

Page generated in 0.0257 seconds