• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 33
  • 33
  • 13
  • 11
  • 10
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Développement d’une nouvelle méthode d’analyse multi-résidus par LDTD/APCI-MS/MS pour la quantification de pesticides et de produits pharmaceutiques dans les eaux usées

Boisvert, Michel 04 1900 (has links)
Une nouvelle méthode d'extraction en phase solide (SPE) couplée à une technique d'analyse ultrarapide a été développée pour la détermination simultanée de neuf contaminants émergents (l'atrazine, le déséthylatrazine, le 17(béta)-estradiol, l'éthynylestradiol, la noréthindrone, la caféine, la carbamazépine, le diclofénac et le sulfaméthoxazole) provenant de différentes classes thérapeutiques et présents dans les eaux usées. La pré-concentration et la purification des échantillons a été réalisée avec une cartouche SPE en mode mixte (Strata ABW) ayant à la fois des propriétés échangeuses de cations et d'anions suivie d'une analyse par une désorption thermique par diode laser/ionisation chimique à pression atmosphérique couplée à la spectrométrie de masse en tandem (LDTD-APCI-MS/MS). La LDTD est une nouvelle méthode d'introduction d'échantillon qui réduit le temps total d'analyse à moins de 15 secondes par rapport à plusieurs minutes avec la chromatographie liquide couplée à la spectrométrie de masse en tandem traditionnelle (LC-MS/MS). Plusieurs paramètres SPE ont été évalués dans le but d'optimiser l'efficacité de récupération lors de l'extraction des analytes provenant des eaux usées, tels que la nature de la phase stationnaire, le débit de chargement, le pH d'extraction, le volume et la composition de la solution de lavage et le volume de l'échantillon initial. Cette nouvelle méthode a été appliquée avec succès à de vrais échantillons d'eaux usées provenant d'un réservoir de décantation primaire. Le recouvrement des composés ciblés provenant des eaux usées a été de 78 à 106%, la limite de détection a été de 30 à 122 ng L-1, alors que la limite de quantification a été de 88 à 370 ng L-1. Les courbes d'étalonnage dans les matrices d'eaux usées ont montré une bonne linéarité (R2 > 0,991) pour les analytes cibles ainsi qu’une précision avec un coefficient de variance inférieure à 15%. / A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants (atrazine, desethylatrazine, 17(beta)-estradiol, ethynylestradiol, northindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole) comprising drugs from different therapeutic classes present in wastewater. Sample pre-concentration and clean-up was performed with a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties followed by analysis by laser diode thermal desorption/atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 seconds compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of stationary phase, the loading flow rate, the extraction pH, the various volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from a primary sedimentation tank. Recoveries of target compounds from wastewater ranged from 78 to 106 %, the limit of detection ranged from 30 to 122 ng L-1 while the limit of quantification ranged from 88 to 370 ng L-1. Calibration curves in wastewater matrix showed good linearity (R2 > 0.991), for all target analytes, and precision (intraday and interday) showed a coefficient of variance below 15%.
32

Développement d’une nouvelle méthode d’analyse multi-résidus par LDTD/APCI-MS/MS pour la quantification de pesticides et de produits pharmaceutiques dans les eaux usées

Boisvert, Michel 04 1900 (has links)
Une nouvelle méthode d'extraction en phase solide (SPE) couplée à une technique d'analyse ultrarapide a été développée pour la détermination simultanée de neuf contaminants émergents (l'atrazine, le déséthylatrazine, le 17(béta)-estradiol, l'éthynylestradiol, la noréthindrone, la caféine, la carbamazépine, le diclofénac et le sulfaméthoxazole) provenant de différentes classes thérapeutiques et présents dans les eaux usées. La pré-concentration et la purification des échantillons a été réalisée avec une cartouche SPE en mode mixte (Strata ABW) ayant à la fois des propriétés échangeuses de cations et d'anions suivie d'une analyse par une désorption thermique par diode laser/ionisation chimique à pression atmosphérique couplée à la spectrométrie de masse en tandem (LDTD-APCI-MS/MS). La LDTD est une nouvelle méthode d'introduction d'échantillon qui réduit le temps total d'analyse à moins de 15 secondes par rapport à plusieurs minutes avec la chromatographie liquide couplée à la spectrométrie de masse en tandem traditionnelle (LC-MS/MS). Plusieurs paramètres SPE ont été évalués dans le but d'optimiser l'efficacité de récupération lors de l'extraction des analytes provenant des eaux usées, tels que la nature de la phase stationnaire, le débit de chargement, le pH d'extraction, le volume et la composition de la solution de lavage et le volume de l'échantillon initial. Cette nouvelle méthode a été appliquée avec succès à de vrais échantillons d'eaux usées provenant d'un réservoir de décantation primaire. Le recouvrement des composés ciblés provenant des eaux usées a été de 78 à 106%, la limite de détection a été de 30 à 122 ng L-1, alors que la limite de quantification a été de 88 à 370 ng L-1. Les courbes d'étalonnage dans les matrices d'eaux usées ont montré une bonne linéarité (R2 > 0,991) pour les analytes cibles ainsi qu’une précision avec un coefficient de variance inférieure à 15%. / A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants (atrazine, desethylatrazine, 17(beta)-estradiol, ethynylestradiol, northindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole) comprising drugs from different therapeutic classes present in wastewater. Sample pre-concentration and clean-up was performed with a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties followed by analysis by laser diode thermal desorption/atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 seconds compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of stationary phase, the loading flow rate, the extraction pH, the various volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from a primary sedimentation tank. Recoveries of target compounds from wastewater ranged from 78 to 106 %, the limit of detection ranged from 30 to 122 ng L-1 while the limit of quantification ranged from 88 to 370 ng L-1. Calibration curves in wastewater matrix showed good linearity (R2 > 0.991), for all target analytes, and precision (intraday and interday) showed a coefficient of variance below 15%.
33

Entwicklung einer Multimethode zur Probenaufarbeitung und Bestimmung von gas- und flüssigkeitschromatographisch erfassbaren Pestiziden in Hühnereiern

Hildmann, Fanny 24 August 2016 (has links)
Die Rückstandsanalytik tierischer Lebensmittel ist eine anspruchsvolle Aufgabe aufgrund des hohen Lipidanteils der Proben sowie des sich stetig vergrößernden Wirkstoffspektrums. Heutzutage werden für die Probenaufarbeitung die DFG S 19 Methode, mit der vorrangig unpolare Analyten nachgewiesen werden und zunehmend die QuEChERS Methode eingesetzt, die insbesondere auf die Erfassung polarer Pestizide abzielt. In dieser Arbeit wurde eine moderne Multirückstandsmethode für Hühnereier entwickelt, um sowohl gas- als auch flüssigkeitschromatographisch (GC, LC) erfassbare Wirkstoffe zu analysieren. Dazu gehören unpolare PCBs, Pyrethroide und Organochlorpestizide, aber auch polarere Organophosphate, Triazole und Carbamate. Das Verfahren basiert auf der Extraktion mittels Matrix Solid Phase Dispersion, der Reinigung auf Grundlage einer modifizierten Gelpermeationschromatographie (GPC) und zwei verschiedenen Festphasenextraktionen (SPEs) für GC- und LC-erfassbare Pestizide sowie der Quantifizierung mittels GC- und LC-MS/MS. Dünnschichtchromatographisch wurde die effektive Entfernung hochmolekularer Lipide durch die modifizierte GPC und niedrigmolekularer Fette durch die SPEs belegt. Laut der für Ei durchgeführten Validierung erfüllten 164 der 172 untersuchten Pestizide und alle sechs PCBs die Leistungskriterien für die amtliche Rückstandskontrolle - zumeist am niedrigsten validierten Level (5 µg/kg bzw. 0,5 µg/kg). Ausnahmen bildeten sehr polare LC-Pestizide (z.B. Aminopyralid, Clopyralid, MCPA, Quinmerac) und pH-Wert-abhängige GC-Analyten (Nicotin, Tolylfluanid, Dichlofluanid), die auch mit den etablierten Verfahren schwierig zu analysieren sind. Weiterhin verdeutlichte die erfolgreiche Untersuchung von verschiedenen Ringversuchsmaterialien, dass die ursprünglich für Eier entwickelte Methode auch für mageres Geflügelfleisch und Sahne genutzt werden kann. Gegenüber den etablierten Verfahren wies die neue Methode deutliche Vorzüge auf. So belegte die Dünnschichtchromatographie, dass mit der neuen Methode Cholesterin, aber auch freie Fettsäuren besser abgetrennt werden als mit den etablierten Verfahren. Die neue Methode verbrauchte im Vergleich zur DFG S 19 Methode 46 % weniger Lösungsmittel und ermöglichte eine Verdopplung des Probendurchsatzes innerhalb von 8 h. Zudem eignete sich das entwickelte Verfahren laut den Validierungsdaten für GC-Analyten deutlich besser als die QuEChERS Methode und etwas besser als die DFG S 19 Methode (v.a. für Pyrethroide). Hinsichtlich der LC-Analyten unterschieden sich die neue und die QuEChERS Methode nur bei wenigen Analyten. Mit dem neuen Verfahren konnten folglich im Gegensatz zu den etablierten Methoden sowohl unpolare GC- als auch polare LC-Analyten sicher erfasst werden.:1 EINLEITUNG UND ZIELSTELLUNG 1 2 THEORETISCHE GRUNDLAGEN 3 2.1 Grundlagen der Pestizidanalytik 3 2.1.1 Definitionen 3 2.1.2 Rechtliche Grundlagen in Bezug auf tierische Lebensmittel 3 2.2 Herausforderung der Analytik tierischer Lebensmittel 6 2.2.1 Erfassen eines breiten Analytspektrums 6 2.2.2 Komplexität der tierischen Matrix 8 2.3 Probenaufarbeitung tierischer Lebensmittel 11 2.3.1 Extraktion 11 2.3.2 Möglichkeiten der Lipid-Reinigung 14 2.3.3 Messmethoden in der modernen Pestizidanalytik 18 2.4 Multimethoden in der Pestizidanalytik tierischer Lebensmittel 21 2.4.1 Vorstellung etablierter Multimethoden 21 2.4.2 Vergleich etablierter Multimethoden 24 2.4.3 Forschungsergebnisse bezüglich fetthaltiger Matrizes bis 2010 26 3 ERGEBNISSE 28 3.1 Auswahl relevanter Analyten in tierischen Lebensmitteln 28 3.2 Auswahl der Matrix Hühnerfrischei 30 3.3 Messung mittels GC-MS/MS und LC-MS/MS 32 3.3.1 Ansatz 32 3.3.2 Erstellung einer GC-MS/MS Datenbank 33 3.3.3 Besonderheiten der SRM-Messmethoden 36 3.3.4 Vorsäulen-Backflush in der Gaschromatographie 38 3.3.5 Leistungsfähigkeit der SRM-Methoden 44 3.4 Beurteilung des Reinigungseffektes 45 3.5 Entwicklung der Probenaufarbeitungsmethode 47 3.5.1 Ziele und allgemeines Vorgehen 47 3.5.2 Extraktion mittels Matrix Solid Phase Dispersion 48 3.5.3 Konzentrierung von Lösungsmittelextrakten 55 3.5.4 Lipidentfernung durch Ausfrieren 56 3.5.5 Modifizierung der GPC zur Verbesserung der Wirtschaftlichkeit 57 3.5.6 Festphasenextraktion 63 3.6 Analysemethode für Eier 78 3.7 Validierung der neuen Analysemethode 82 3.7.1 Hintergrund und Durchführung 82 3.7.2 Linearität 83 3.7.3 Spezifität 84 3.7.4 Wiederfindungsraten und Wiederholbarkeit 84 3.7.5 Bestimmungsgrenze 88 3.7.6 Matrix-spezifische Auswirkung auf die Analyten 88 3.8 Vergleich mit etablierten Probenaufarbeitungsmethoden 89 3.8.1 Ansatz 89 3.8.2 Reinigungseffekt 90 3.8.3 Validierungsdaten 93 3.8.4 Identifizierung und Quantifizierung anhand gewachsener Rückstände 95 3.8.5 Zusammenfassende Bewertung 97 3.9 Untersuchung verschiedener Ringversuchsmaterialien 99 4 DISKUSSION 103 4.1 Entwickelte Analysemethode 103 4.2 Ausblick 111 5 ZUSAMMENFASSUNG 113 6 LITERATUR 117 7 ANHANG A-1

Page generated in 0.0527 seconds