• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 13
  • 9
  • 7
  • 7
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da reação tecidual de uma resina termoplástica em tecido subcutâneo de ratos

Alfenas, Elizabeth Rodrigues [UNESP] 31 July 1995 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 1995-07-31Bitstream added on 2015-01-26T13:30:30Z : No. of bitstreams: 1 000022881.pdf: 1385395 bytes, checksum: efffbbc6c72ead3e8277aa26da7979ee (MD5) / A reação tecidual do subcutâneo de ratos foi avaliada por meio da implantação de corpos de prova de uma resina termoplástica (T AK Hydroplastic-DFL). A resina termoplástica foi testada em suas diferentes cores (rosa, amarela, azul e branca). Utilizamos como grupo controle a resina acrílica termicamente ativada incolor. Os corpos de prova em forma de pastilhas, com aproximadamente 8 mm de diâmetro por 1 mm de espessura, foram inseridos em lojas cirúrgicas preparadas no dorso dos animais, que foram sacrificados após os períodos de observação de 2, 3, 6, e 12 semanas. Os tecidos adjacentes aos implantes foram removidos, receberam tratamento histológico de rotina, coloração pela hematoxilina e eosina e pelo tricrômio de Mallory. Os resultados foram analisados por microscopia óptica, e o tecido subcutâneo adjacente aos implantes de resina termoplástica exibiu reação inflamatória moderada nos períodos iniciais de observação (2 e 3 semanas) com reparação da área e formação de cápsula fibrosa envolvendo todos os corpos de prova no período final de 12 semanas. Os resultados obtidos nos permitiram concluir que: • a resina termoplástica nas cores rosa, amarela, azul e branca, não determinou reação tecidual desfavorável em 12 semanas de implantação; • a resina do Grupo controle e a resina termoplástica azul determinaram uma resposta tecidual menos favorável do que a da resina termoplástica nas cores rosa, amarela e branca / Subcutaneous rat tissue reaction was evaluated using samples of a thermoplastic resin(TAK Hydroplastic-DFL) of different colours: pink, yellow, blue and white. As control, a transparent thermally activated acrylic resin was used. Samples with a diameter of approximately 8 mm and thickness of 1 mm were implanted in surgical wounds on the back of rats, which were then sacrificed at periods of 2, 3, 6, and 12 weeks. The adjacent tissue was removed and prepared histologically using hematoxilin-eosin and Mallory trichrorne techniques. Through optical microscopy, it was observed that the subcutaneous adjacent to the resin implants showed a moderate inflammatory reaction during the weeks 2 and 3. At the end of week 12, tissue recovery and capsular formation surrounding the resin implant were observed. It was concluded that: • the thermoplastic resin in pink, yellow, b1ue and white colours didn't determine unfavourable tissue reaction in the 12 weeks of implantation; • the resin of the control group and the blue thermoplastic resin determined a tissue response that was less favourable than the thermoplastic resin in pink, yellow and white colours
12

Efeito do envelhecimento acelerado sobre a microdureza superficial, rugosidade e opacidade de resinas acrílicas incolores termopolimerizáveis e calotas oculares empregadas em prótese ocular, em função da espessura

Fernandes, Aline Úrsula Rocha [UNESP] 12 December 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-12-12Bitstream added on 2014-06-13T20:25:52Z : No. of bitstreams: 1 fernandes_aur_dr_araca.pdf: 3876257 bytes, checksum: 0b3f599e97b9e9ee18afc401d2068c8c (MD5) / As próteses oculares são responsáveis pelo restabelecimento da estética, harmonia facial e auto-estima do paciente anoftálmico. Confeccionados em resina acrílica, os olhos artificiais devem ser estéticos, perfeitamente polidos e resistentes a riscos, características que, quando não satisfeitas, podem gerar transtornos psicológicos, possíveis infecções ou inflamações originárias de substâncias e organismos depositados nas irregularidades superficiais da prótese. O propósito do estudo foi avaliar a microdureza e rugosidade superficiais e opacidade de calotas incolores próprias para prótese ocular e de três marcas de resina acrílica incolor termopolimerizável por banho de água quente de curta e média duração e duas por energia de microondas, em função do envelhecimento acelerado (1008 horas) e espessura (1 e 3,5 mm). Para o estudo, foram obtidas 120 amostras, distribuídas em 12 grupos (n= 10). A análise foi realizada por meio de microdurômetro (Shimadzu Corp., Kyoto, Japão), rugosímetro (TONKA Sul Americana Ltda., SP, Brasil) e espectrofotômetro de reflexão (Shimadzu Corp., Kyoto, Japão). Os valores obtidos antes e após envelhecimento acelerado foram analisados estatisticamente pela Análise de Variância de três fatores e pelo teste de Tukey a 1% de significância. Para o teste de microdureza, as calotas oculares e a resina QC 20 apresentaram, respectivamente, os maiores e menores valores de microdureza superficial, independente da variável avaliada; a espessura não influenciou a propriedade estudada e as amostras apresentaram valores médios de microdureza superficial maiores após o envelhecimento acelerado. / Artificial eyes are responsible for reestablishing the facial esthetics, harmony and self esteem of the anophthalmic patient. Made of acrylic resin, artificial eyes must be esthetic, perfectly polished and scratchresistant characteristics which, when not satisfied, may cause psychological disturbances, possible infections or inflammations originating from substances and organisms deposited on the surface irregularities of the prosthesis. The aim of this study was to assess the microhardness, surface roughness and opacity of colorless ocular button for the purpose of use in artificial eyes, and three brands of colorless acrylic resin heat-polymerizable by hot water bath of short and medium duration and two by microwave energy, as a function of accelerated aging (1008 hours) and thickness (1 and 3.5 mm). For this study, 120 samples were obtained, distributed into 12 groups (n=10). Analysis was performed by means of microhardness meter (Shimadzu Corp., Kyoto, Japan), rugosity meter (TONKA Sul Americana Ltda., SP, Brazil) and reflection spectrophotometer (Shimadzu Corp., Kyoto, Japan). The values obtained before and after accelerated aging were statistically analyzed by Analysis of Variance for 3 factors and the Tukey test at 1% significance. For the microhardness test, the ocular buttons and QC 20 resin respectively presented the highest and lowest surface microhardness values, irrespective of the variable assessed; the thickness had no influence on the studied property, and the samples presented higher mean surface microhardness values after accelerated aging. For the roughness test, there was no statistically significant difference with regard to accelerated aging; the resin Vipi Cril, at the thickness of 3.5 mm and ocular button at the thickness of 1 mm presented the lowest roughness value.
13

Comparação da desadaptação marginal de infra-estruturas metálicas obtidas com variações na técnica de fundição, revestimentos e material para obtenção dos padrões

Zequetto, Michele Marques [UNESP] 07 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-07Bitstream added on 2014-06-13T20:37:53Z : No. of bitstreams: 1 zequetto_mm_me_araca.pdf: 764308 bytes, checksum: f9f1ab6ade3df1b1023440b60d0137eb (MD5) / Pro-Line Servicos Produtos Odontologicos Ortopedicos Ltda. / O presente trabalho avaliou a desadaptação marginal de infra-estruturas metálicas de coroas metalo-cerâmicas obtidas com técnicas de fundição convencional (T1) e rápida (T2), utilizando para inclusão os revestimentos: aglutinado por fosfato Termocast (R1) e a base de cerâmica granulada Micro Fine 1700 (R2), confeccionando padrões em cera escultura Galileo (P1) e padrões em resina acrílica Duralay (P2), com n=56, sobre um troquel metálico. Para a construção dos padrões, utilizou-se uma matriz de silicone e realizou-se a fundição com liga de Ni-Cr. Verificou-se a desadaptação marginal por meio de um microscópio comparador digital Mitutoyo em 12 diferentes pontos de cada infra-estrutura. Os dados obtidos foram submetidos à análise de variância (ANOVA) e teste de Tukey com p<0.05, demonstrando os menores valores de desadaptação marginal e, estatisticamente similares (p<0.05), em ordem crescente, para os grupos: P2R2T2 (55,4æm), P2R1T2 (55,6æm), P2R1T1 (57,4æm), P1R2T2 (59,4æm), P1R2T1 (86æm), P1R1T1(104,4æm); e os maiores valores para P1R1T2 (166,9æm) e P2R2T1 (185,3æm). Os resultados obtidos permitiram concluir que as infra-estruturas metálicas obtidas com padrões, tanto de cera quanto de resina acrílica, apresentaram valores aceitáveis em ambas as técnicas de fundição realizadas, desde que as interações e recomendações dos fabricantes dos revestimentos sejam respeitadas. / The present study evaluated the marginal unfit of metallic infrastructures of metallic-ceramic crowns obtained through the conventional (T1) and accelerated (T2) casting techniques, using for investing the investments: agglutinated by phosphate Termocast (R1) and the base of granulated ceramic Micro Fine 1700 (R2), making patterns in sculpture wax Galileo (P1) and patterns in acrylic resin Duralay (P2), with n=56, on a metallic die with shoulder in chamfer. For the construction of the patterns, a matrix of silicone was used and the casting was made with Ni-Cr alloy. The marginal unfit was verified through the comparing microscope Mitutoyo in 12 different points of each infrastructure. The values obtained were submitted to analysis of variance (ANOVA) and Tukey s test with p<0.05, showed smaller values and statistically similar, in increasing order, for the groups: P2R2T2 (55,4ìm), P2R1T2 (55,6ìm), P2R1T1 (57,4ìm), P1R2T2 (59,4ìm), P1R2T1 (86ìm), P1R1T1(104,4ìm); and the largest values for P1R1T2 (166,9ìm) and P2R2T1 (185,3ìm). Taking obtained results into account, it was possible to conclude that the metallic infrastructures obtained from patterns, of wax as well as of acrylic resin, presented acceptable values of marginal fit in both casting techniques, providing the interactions and the recommendations of the investments manufacturers are respected.

Page generated in 0.1328 seconds