• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do acréscimo de nanopartículas radiopacas no desempenho de um sistema adesivo experimental autocondicionante livre de Hema / Effect of addition of radiopaque nanoparticles on performance of an experimental Hema free adhesive system

Macedo, Cármen Lúcia Rodrigues 20 November 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-22T15:47:47Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Efeito do acréscimo de nanopartículas radiopacas no desempenho de um sistema adesivo experimental autocondicionante livre de Hema.pdf: 1361139 bytes, checksum: 1cfb6b2bb9c9995f2dae4f8712280b04 (MD5) / Made available in DSpace on 2017-05-22T15:47:47Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Efeito do acréscimo de nanopartículas radiopacas no desempenho de um sistema adesivo experimental autocondicionante livre de Hema.pdf: 1361139 bytes, checksum: 1cfb6b2bb9c9995f2dae4f8712280b04 (MD5) Previous issue date: 2014-11-20 / Sem bolsa / O objetivo deste estudo foi desenvolver um sistema adesivo nanoestruturado, do tipo autocondicionante de dois passos, de alto desempenho e radiopaco. Para isso, primers autocondicionantes foram formulados a partir da mistura de GDMA-P, HEMA ou UDMA PEG 400, etanol e água. Os adesivos de cobertura foram formulados com Bis-GMA, TEGDMA, HEMA ou UDMA PEG 400, CQ e EDAB, além de nanopartículas de trifluoreto de itérbio (YbF3) ou sílica (SiO2). Os adesivos foram avaliados por testes de grau de conversão, radiopacidade, índice de refração, resistência flexural, módulo flexural, sorção e solubilidade em água e resistência de união à dentina após 24h ou 6 meses de imersão em água destilada. Os dados foram analisados estatisticamente com ANOVA e teste complementar de Tukey (α=5%). A concentração mínima de 20% em peso (carga) foi necessária para adesivos contendo UDMA PEG 400 tornarem-se radiopacos, e de 30% em peso (carga) para os adesivos contendo HEMA. De maneira geral, as propriedades físicas avaliadas foram mantidas ou melhoradas a partir da adição das partículas. A adesão à dentina após 6 meses de armazenagem em água foi prejudicada nos grupos contendo sílica, porém o YbF3 protegeu a degradação da adesão no adesivo contendo HEMA, embora no adesivo contendo UDMA PEG 400, ele resultou em redução da adesão. A adição de partículas nanométrica em adesivos odontológicos é uma estratégia viável para aprimorar o desempenho desses materiais. / The aim of this study was to develop a nanostructured adhesive system, two-step self-etch, with high performance and radiopacity property. Selfething-primers were formulated by mixing GDMA-P, HEMA or PEG 400 UDMA, ethanol and water. The resin adhesives were formulated with Bis-GMA, TEGDMA, HEMA or PEG 400 UDMA, CQ and EDAB, besides ytterbium fluoride (YbF3) or silica (SiO2) nanoparticles were added. The adhesives were analyzed using degree of conversion, radiopacity, refractive index, flexural strength, flexural modulus, water sorption and solubility tests. The bond strength to dentin after 24h and 6 months of water storage was also performed. Data were statistically analyzed using ANOVA and Tukey test (α=5%). The minimal concentration in mass of 20% was necessary for the PEG 400 UDMA-based adhesives become radiopaque, and of 30% for the HEMA-containing adhesives. In the overall analysis, the physical properties investigated were maintained or improved by addition of nanoparticles. The adhesion to dentin after 6 months of water storage was negatively affected within the SiO2-based groups, but YbF3 hampered the adhesion degradation within the HEMA-containing adhesive, although within the PEG 400 UDAM-based adhesive it resulted in decrease of microtensile bond strenght. The incorporation of nanofillers into dental adhesives seems to be an interesting way to achieve enhanced properties, although the domain of this technology still needs further further studies to better understand the effect of incorporation of fillers and/or with their surface treatment.
2

Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA) / Development of adhesive systems employing surfactant monomers as substitute to hydroxyethyl methacrylate (HEMA)

Zanchi, Cesar Henrique 07 May 2010 (has links)
Made available in DSpace on 2014-08-20T14:30:11Z (GMT). No. of bitstreams: 1 Tese_Cesar_Henrique_Zanchi.pdf: 1068579 bytes, checksum: 8e2ef86f128f91b16a71c1a2e41952f6 (MD5) Previous issue date: 2010-05-07 / This study evaluated the influence of surfactant dimethacrylates (SD) on the resin-to-dentin immediate and long term microtensile bond strength (μTBS) and characterized the interfacial micromorphology of hybrid layer of the experimental HEMA-free self-etching systems. Five experimental HEMA-free two step self-etching systems containing different surfactant dimetacrylates (SD) (Bis-EMA 10, Bis-EMA 30, PEG 400, PEG 1000 and PEG 400 UDMA) and a HEMA-containing systems (control) were formulated. Sixty bovine incisors were allocated into six groups according each experimental adhesive system used. The teeth had the superficial coronal dentins exposed and were restored and sectioned to obtain sticks randomly allocated into 3 storage periods: 24h, 6 and 12 months. Thereafter the specimens were subjected to the μTBS test. Immediate μTBS data were analyzed by One-way ANOVA and Tukey s test. Long term μTBS data were analyzed by Kruskall-Wallis and Dunn test (α = 0.05). Analysis of the adhesive-dentin interfaces were performed through scanning electron microscopy. Between the HEMA-free groups, the adhesive system formulated with PEG 400 UDMA produced the highest μTBS and was similar to HEMA-containing group. Specimens of the 24 hours of storage were statistically higher for all groups tested when compared those after 6 and 12 months storage. None difference was found between 6 months and 12 months storage for each group. All the adhesives systems presented similar partially demineralized hybrid layer (1.5-3.0 μm thickness) with well formed resin tags. All SD present reasonable μTBS, being the PEG 400 UDMA a promising monomer to be considered as HEMA substitute in adhesive systems compositions. / Este estudo avaliou a influência de dimetacrilatos surfactantes (DS) na resistência de união à dentina por microtração (RU), imediata e após armazenagem, além de caracterizar a micromorfologia da camada híbrida de sistemas adesivos experimentais autocondicionantes livres de HEMA. Foram formulados cinco sistemas adesivos autocondicionantes de dois passos livres de HEMA contendo diferentes DS (Bis-EMA 10, Bis-EMA 30, PEG 400, PEG 1000 and PEG 400 UDMA) e um sistema contendo HEMA, empregado como controle. Foi realizada a exposição da dentina superficial de sessenta incisivos bovinos posteriormente alocados em seis grupos experimentais de acordo com o sistema adesivo empregado. Os dentes foram restaurados e seccionados para obter espécimes (palitos) posteriormente divididos em três períodos de armazenagem: 24h, 6 e 12 meses. Após, os espécimes foram sujeitos ao teste de RU. Resultados de RU imediata foram analisados por ANOVA 1-fator e teste complementar de Tukey. Resultados de RU após envelhecimento foram analisados por Kruskall-Wallis e teste de Dunn (α = 0.05). Analises das interfaces de união dente-restauração foram realizadas através de microscopia eletrônica de varredura. Entre os grupos livres de HEMA, o sistema adesivo formulado com PEG 400 UDMA produziu maior RU e foi estatisticamente similar ao grupo controle contendo HEMA. Os espécimes testados após 24 horas de armazenamento apresentaram RU estatisticamente maior para todos os grupos quando comparados os espécimes testados após 6 e 12 meses de armazenagem. Não foram observadas diferenças significativas entre os grupos testados após 6 e 12 meses. Todos os sistemas adesivos apresentaram camada hibrida parcialmente desmineralizada (1.5-3 μm de espessura) com formação de prolongamentos resinosos. Em geral os sistemas adesivos demonstraram valores de RU satisfatórios, sendo o PEG 400 UDMA um monômero promissor para o desenvolvimento de sistemas adesivos livres de HEMA.

Page generated in 0.0994 seconds