Spelling suggestions: "subject:"desistência hidráulica"" "subject:"esistência hidráulica""
1 |
Comparação da efetividade e segurança de soluções de manutenção intermitente de cateter venoso central de longa permanência em pacientes submetidos à hemodiálise. / The comparison of effectiveness and safety of lock solutions for long-term central venous catheter of patients on hemodialysis.Luiz, Marcus Vinicius de Souza João 24 January 2017 (has links)
Resistência hidráulica é altamente prevalente em cateteres venosos centrais de longa permanência. Selos de heparina são comumente utilizados para manter evitar o problema, mas mostram pouca efetividade. O objetivo do presente estudo foi avaliar a efetividade e segurança de dois selos quanto à redução de ocorrência de incidência de baixo fluxo. Setenta e cinco pacientes com doença renal crônica no estágio 5D em hemodiálise de alta eficiência no Centro Integrado de Nefrologia (Guarulhos, Brasil) foram randomizados na proporção de 1:1:1 para receber selo contendo a combinação de minociclina 3 mg/ml com o anticoagulante/quelante EDTA 30 mg/ml (M-EDTA), heparina 1.000 U/mL (Heparina) ou citrato trissódico 30% (Citrato) por 15 semanas. Sessenta e oito pacrticipantes terminaram o estudo no qual ambos participantes e investigadores foram cegos quanto à alocação do tratamento. O desfecho primátio de efetividade foi ocorrência de resistência hidráulica e o desfecho secundário de segurança foi ocorrência de reações adversas a selos. A incidência de resistência hidráulica foi significantemente maior em cateteres selados com Heparina (18/23) comparado com os selos Citrato (4/22) e M-EDTA (2/23) (p< 0.001). O estudo clínico sugere que o Citrato e M-EDTA mantem a patência de cateteres melhor que a heparina 1.000 UI/ml, sendo altamente custo-efetivos em comparação com heparina 1.000 UI/ml. Ainda, o Citrato pode ser a melhor opção de selo por não se associar com resistência antimicrobiana a longo prazo. / Hydraulic Resistance is highly prevalent among long-term central venous catheters. Heparin catheter lock solutions are commonly used to maintain catheter patency, however this problem remains high. The purpose of the CLOCK Trial was to evaluate two catheter lock solutions as to their effectiveness and safety. Seventy-five CKD 5D patients on high-efficiency hemodialysis at the Integrated Centre of Nephrology (Guarulhos, Brazil) were randomized 1:1:1 to receive a lock solution combining minocycline 3 mg/ml with the anticoagulant/chelation agent EDTA 30 mg/ml (M-EDTA) or heparin 1,000 IU/ml (Heparin) or trisodium citrate 30% (Citrate) versus Heparin for 15 weeks. A total of 68 patients completed the trial in which both investigators and patients were blinded to treatment allocation. The primary end-point was the occurrence of hydraulic resistance and secondary safety end-point was adverse drug reactions related to the lock solutions. The incidence of hydraulic resistance was significantly higher among patients on Heparin (18/23) compared to Citrate (4/22) and M-EDTA (2/23) lock solutions, (p< 0.001). The trial suggests Citrate and M-EDTA may preserve catheter patency better than Heparin and they may show higher cost-effectiveness when compared to heparin. Citrate may be a better option due the lack of association with longterm antimicrobial resistance.
|
2 |
Comparação da efetividade e segurança de soluções de manutenção intermitente de cateter venoso central de longa permanência em pacientes submetidos à hemodiálise. / The comparison of effectiveness and safety of lock solutions for long-term central venous catheter of patients on hemodialysis.Marcus Vinicius de Souza João Luiz 24 January 2017 (has links)
Resistência hidráulica é altamente prevalente em cateteres venosos centrais de longa permanência. Selos de heparina são comumente utilizados para manter evitar o problema, mas mostram pouca efetividade. O objetivo do presente estudo foi avaliar a efetividade e segurança de dois selos quanto à redução de ocorrência de incidência de baixo fluxo. Setenta e cinco pacientes com doença renal crônica no estágio 5D em hemodiálise de alta eficiência no Centro Integrado de Nefrologia (Guarulhos, Brasil) foram randomizados na proporção de 1:1:1 para receber selo contendo a combinação de minociclina 3 mg/ml com o anticoagulante/quelante EDTA 30 mg/ml (M-EDTA), heparina 1.000 U/mL (Heparina) ou citrato trissódico 30% (Citrato) por 15 semanas. Sessenta e oito pacrticipantes terminaram o estudo no qual ambos participantes e investigadores foram cegos quanto à alocação do tratamento. O desfecho primátio de efetividade foi ocorrência de resistência hidráulica e o desfecho secundário de segurança foi ocorrência de reações adversas a selos. A incidência de resistência hidráulica foi significantemente maior em cateteres selados com Heparina (18/23) comparado com os selos Citrato (4/22) e M-EDTA (2/23) (p< 0.001). O estudo clínico sugere que o Citrato e M-EDTA mantem a patência de cateteres melhor que a heparina 1.000 UI/ml, sendo altamente custo-efetivos em comparação com heparina 1.000 UI/ml. Ainda, o Citrato pode ser a melhor opção de selo por não se associar com resistência antimicrobiana a longo prazo. / Hydraulic Resistance is highly prevalent among long-term central venous catheters. Heparin catheter lock solutions are commonly used to maintain catheter patency, however this problem remains high. The purpose of the CLOCK Trial was to evaluate two catheter lock solutions as to their effectiveness and safety. Seventy-five CKD 5D patients on high-efficiency hemodialysis at the Integrated Centre of Nephrology (Guarulhos, Brazil) were randomized 1:1:1 to receive a lock solution combining minocycline 3 mg/ml with the anticoagulant/chelation agent EDTA 30 mg/ml (M-EDTA) or heparin 1,000 IU/ml (Heparin) or trisodium citrate 30% (Citrate) versus Heparin for 15 weeks. A total of 68 patients completed the trial in which both investigators and patients were blinded to treatment allocation. The primary end-point was the occurrence of hydraulic resistance and secondary safety end-point was adverse drug reactions related to the lock solutions. The incidence of hydraulic resistance was significantly higher among patients on Heparin (18/23) compared to Citrate (4/22) and M-EDTA (2/23) lock solutions, (p< 0.001). The trial suggests Citrate and M-EDTA may preserve catheter patency better than Heparin and they may show higher cost-effectiveness when compared to heparin. Citrate may be a better option due the lack of association with longterm antimicrobial resistance.
|
3 |
A variação da Resistência Total em Canais Aluviais e sua previsão. / The variation of Total Resistance in Alluvial Channels and its prediction.ALCÂNTARA, Hugo Morais de. 05 September 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-09-05T18:25:04Z
No. of bitstreams: 1
HUGO MORAIS DE ALCÂNTARA - DISSERTAÇÃO PPGECA 2007..pdf: 2937576 bytes, checksum: 4120665ff013d35f135ab12cfe7ca9a5 (MD5) / Made available in DSpace on 2018-09-05T18:25:04Z (GMT). No. of bitstreams: 1
HUGO MORAIS DE ALCÂNTARA - DISSERTAÇÃO PPGECA 2007..pdf: 2937576 bytes, checksum: 4120665ff013d35f135ab12cfe7ca9a5 (MD5)
Previous issue date: 2007-03-29 / O presente trabalho tem o objetivo de avaliar a natureza da variação da resistência
total em canais aluviais e propor uma função de resistência total. A partir da equação
fundamental da resistência da superfície, é definida uma função cuja variação pode ser
associada aos efeitos da forma do leito e da distribuição granulométrica de sedimentos. A
forma desta função, obtida através de análise dimensional utilizando a técnica de regressão linear múltipla, é apresentada para sedimentos unimodais e bimodais associada a cada tipo de canal e mistura de sedimentos. Foi utilizada uma grande massa de dados experimentais de laboratório e de campo coletados por diversos pesquisadores em vários estudos. Com base nos diversos estudos encontrados na bibliografia e considerando as incertezas envolvidas na separação da resistência total em, a resistência devido aos grãos na superfície e das formas do leito, decidiu-se propor uma função de resistência separadamente para cada forma do leito para o parâmetro de resistência B. A grande vantagem da metodologia proposta é que esta avalia a resistência total do leito sem a necessidade de separação dos efeitos dos grãos e das formas do leito. Os resultados mostram que uma excelente relação funcional pode ser estabelecida para cada forma do leito e mistura de sedimentos utilizando três e dois parâmetros adimensionais. O efeito da distribuição granulométrica dos sedimentos ficou evidenciado no caso do leito plano e com sedimentos bimodais, indicando que nos casos em que a distribuição natural – log-normal – de sedimentos não seja aplicável, o efeito da distribuição granulométrica é significativo na resistência total do canal aluvial. / The present work has the objective of evaluating the variation of the hydraulic
resistance in alluvial channels and propose a function of total resistance. Starting from the
fundamental concept of the resistance of the surface, a function is defined in which the
variation of resistance can be associated with the characteristics of the bed form and the grain size distribution of the mixture of the sediments in the bed. The form of this function,
obtained through dimensional analysis using the technique of multiple linear regression, is
presented for unimodal and bimodal sediments associated with each channel type and mixture of sediments. Utilizing the data collected by various researchers in laboratory canals and rivers, the functional relationships for the resistance factor, here in identified as a dimensionless factor “B”, has been established utilizing three, or in a simple form, two,
dimensionless parameters as independent variables. The great advantage of the resistance function proposed here is that it eliminates the need to separate the total resistance into two components. The results show that an excellent functional relationship can be established for each bed form and mixture of sediments using three parameters. The influence of the grain size distribution of the sediments was evidenced in the case of all the bed forms and especially bimodal sediments. In the cases of natural distribution (log-normal) of sediments in the sand range, the effect on the individual grain size distributions became hardly noticeable.
|
Page generated in 0.0802 seconds