• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 8
  • 8
  • 8
  • 8
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Clinical assessment of respiratory distress syndrome

Korvenranta, Heikki. January 1983 (has links)
Thesis (doctoral)--University of Turku. / Includes reprints of 5 publications on which thesis is based.
2

Praenatal bestemmelse af lungematuriteten og forebyggelse af idiopatisk respiratory distress syndrom lecithin-sphingomyelin ratio i amnionvaesken /

Verder, Henrik. January 1980 (has links)
Thesis (doctoral)--Københavns Universitet.
3

Surfactant metabolism in the newborn : the impact of ventilation strategy and lung disease /

Bohlin, Kajsa, January 2005 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2005. / Härtill 5 uppsatser.
4

Effects of lung injury on neonatal thrombocytopoiesis. / CUHK electronic theses & dissertations collection

January 2002 (has links)
Yang Jie. / "January, 2002." / Thesis (Ph.D.)--Chinese University of Hong Kong, 2002. / Includes bibliographical references (p. 204-250). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Mode of access: World Wide Web. / Abstracts in English and Chinese.
5

Regulation of breathing under different pulmonary conditions /

Rieger-Fackeldey, Esther, January 2004 (has links)
Diss. (sammanfattning) Uppsala : Univ., 2004. / Härtill 4 uppsatser.
6

Advanced radiological imaging in patients treated with extracorporeal membrane oxygenation /

Lidegran, Marika, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2006. / Härtill 5 uppsatser.
7

Estudo controlado e randomizado entre o uso de ventilação por pressão positiva intermitente e pressão positiva contínua em vias aéreas em recém-nascidos pré-termo após a extubação traqueal / Randomized controlled trial comparing nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure in premature infants after tracheal extubation

Komatsu, Daniela Franco Rizzo 06 September 2007 (has links)
Objetivos: Analisar a frequência de falha da extubação em recém-nascidos pré-termo em ventilação mecânica convencional após a extubação traqueal nos grupos submetidos a ventilação por pressão positiva intermitente por via nasal (nIPPV) e pressão positiva contínua em vias aéreas (nCPAP). Métodos: Foram estudados 72 recém-nascidos pré-termo portadores de insuficiência respiratória, com idade gestacional 750 gramas, que necessitaram de entubação traqueal e ventilação mecânica. Após terem preenchido os critérios de extubação, os recém-nascidos foram submetidos a nIPPV (n=36) ou nCPAP (n=36) de acordo com o resultado da randomização. Os parâmetros iniciais para os RN randomizados para nIPPV foram: FR = 12 ipm; PIP = 16 cm H20; PEEP= 6 cm H20; FiO2 ? 40%, e para aqueles randomizados para nCPAP foram P=6 cm H2O; FiO2 < 40%. O estudo foi finalizado após um tempo de extubação de 72 horas ou quando o RN preenchesse os critérios de falha na extubação. O projeto de pesquisa foi aprovado pela Comissão de Ética de ambos os Serviços. Resultados: A grande maioria dos RN recebeu pelo menos uma dose de surfactante exógeno (80,5% no grupo nIPPV e 83,3% no grupo nCPAP, P= 1). O tempo médio de permanência em ventilação mecânica também foi semelhante (6,2 e 7,3 dias, P= 0,59, respectivamente). Entre os 36 RN randomizados para nIPPV, 6 (16,6%) apresentaram falha de extubação em comparação a 11 (30,5%) dos 36 RN randomizados para nCPAP. Apesar de se ter observado redução relativa de risco de falha de extubação da ordem de 45% (IC 95%: 0,23 a 1,32) a favor da nIPPV, esta diferença não alcançou significância estatística. Constatamos uma chance de falha de extubação de 4,38 vezes no grupo nCPAP quando comparado ao grupo nIPPV após excluírmos os RN com peso de nascimento inferior a 1000 gramas, sendo esta diferença estatisticamente significativa (P= 0,045).Complicações gastrointestinais e neurológicas, além de outras complicações, não ocorreram nos recém nascidos pré-termo submetidos à nIPPV ou nCPAP após a extubação. Conclusões: Embora a distribuição de frequências de falha da extubação tenha mostrado numericamente um menor índice de falha nos RNPT submetidos a nIPPV em relação àqueles submetidos a nCPAP, não houve diferença estatísticamente significante entre os dois modos de suporte ventilatório após a extubação. Ao excluirmos da análise os RN com peso de nascimento inferior a 1000 gramas constatamos um aumento estatisticamente significante na chance de falha no grupo nCPAP. / Objetive: To analyze the frequency of failed extubation in premature infants following mechanical ventilation placed on either nasal intermittent positive pressure ventilation (nIPPV) or nasal continuous positive airway pressure (nCPAP) after endotracheal tube removal. Methods: Seventy two premature infants with respiratory insufficiency and gestacional age 750 grams, who needed endotracheal intubation and mechanical ventilation were studied. Once the babies reached the criteria for exubation, they were randomized to either nIPPV (n=36) or to nCPAP (n=36) in accordance with the randomization resulted. The inicial settings for those randomized to nIPPV were: rate=12; PIP=16 cm H20; PEEP=6 cm H20; FiO2 < 40%, and for those randomized to nCPAP were P=6 cm H2O; FiO2 < 40%. The study ended after 72 hours or when the infants reached the criteria of failure of the extubation. Ethical Approval was obtained from the Hospital. Results: Most received at least one dose of exogenous surfactant (80,5% in the nIPPV group and 83,3% in the nCPAP group, P= 1). The average time of mechanical ventilation also was similar (6.2 and 7.3 days respectively, P= 0.59). Of the 36 infants randomized to nIPPV, six (16,6%) failed extubation in comparison to 11 (30,5%) of the 36 newborn randomized to nCPAP. Although to have itself observed relative reduction of risk failure of extubation the order of 45% (95%CI: 0,23 to 1,32) in the group nIPPV, this difference did not reach significance statistics. We verified a increaset of failure extubation of 4,38 times in the nCPAP group when compared to the group nIPPV after excluded premature infant from birthweight less than 1000 grams, this difference was significant (P = 0,045). Gastrointestinal and neurological complications, beyond other complications, had no occurred in premature infants submitted to nIPPV or nCPAP after the extubation. Conclusions: Although the distribution of frequencies has numerically shown a lesser index of failure in premature infants submitted to nIPPV in relation to those submitted to nCPAP after extubation they did not have statistical significance difference between the two ways of ventilatory support. To the excluded of the analysis premature infant with birthweight less than 1000 grams, verified an increase significant in the failure extubation in the nCPAP.group .
8

Estudo controlado e randomizado entre o uso de ventilação por pressão positiva intermitente e pressão positiva contínua em vias aéreas em recém-nascidos pré-termo após a extubação traqueal / Randomized controlled trial comparing nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure in premature infants after tracheal extubation

Daniela Franco Rizzo Komatsu 06 September 2007 (has links)
Objetivos: Analisar a frequência de falha da extubação em recém-nascidos pré-termo em ventilação mecânica convencional após a extubação traqueal nos grupos submetidos a ventilação por pressão positiva intermitente por via nasal (nIPPV) e pressão positiva contínua em vias aéreas (nCPAP). Métodos: Foram estudados 72 recém-nascidos pré-termo portadores de insuficiência respiratória, com idade gestacional 750 gramas, que necessitaram de entubação traqueal e ventilação mecânica. Após terem preenchido os critérios de extubação, os recém-nascidos foram submetidos a nIPPV (n=36) ou nCPAP (n=36) de acordo com o resultado da randomização. Os parâmetros iniciais para os RN randomizados para nIPPV foram: FR = 12 ipm; PIP = 16 cm H20; PEEP= 6 cm H20; FiO2 ? 40%, e para aqueles randomizados para nCPAP foram P=6 cm H2O; FiO2 < 40%. O estudo foi finalizado após um tempo de extubação de 72 horas ou quando o RN preenchesse os critérios de falha na extubação. O projeto de pesquisa foi aprovado pela Comissão de Ética de ambos os Serviços. Resultados: A grande maioria dos RN recebeu pelo menos uma dose de surfactante exógeno (80,5% no grupo nIPPV e 83,3% no grupo nCPAP, P= 1). O tempo médio de permanência em ventilação mecânica também foi semelhante (6,2 e 7,3 dias, P= 0,59, respectivamente). Entre os 36 RN randomizados para nIPPV, 6 (16,6%) apresentaram falha de extubação em comparação a 11 (30,5%) dos 36 RN randomizados para nCPAP. Apesar de se ter observado redução relativa de risco de falha de extubação da ordem de 45% (IC 95%: 0,23 a 1,32) a favor da nIPPV, esta diferença não alcançou significância estatística. Constatamos uma chance de falha de extubação de 4,38 vezes no grupo nCPAP quando comparado ao grupo nIPPV após excluírmos os RN com peso de nascimento inferior a 1000 gramas, sendo esta diferença estatisticamente significativa (P= 0,045).Complicações gastrointestinais e neurológicas, além de outras complicações, não ocorreram nos recém nascidos pré-termo submetidos à nIPPV ou nCPAP após a extubação. Conclusões: Embora a distribuição de frequências de falha da extubação tenha mostrado numericamente um menor índice de falha nos RNPT submetidos a nIPPV em relação àqueles submetidos a nCPAP, não houve diferença estatísticamente significante entre os dois modos de suporte ventilatório após a extubação. Ao excluirmos da análise os RN com peso de nascimento inferior a 1000 gramas constatamos um aumento estatisticamente significante na chance de falha no grupo nCPAP. / Objetive: To analyze the frequency of failed extubation in premature infants following mechanical ventilation placed on either nasal intermittent positive pressure ventilation (nIPPV) or nasal continuous positive airway pressure (nCPAP) after endotracheal tube removal. Methods: Seventy two premature infants with respiratory insufficiency and gestacional age 750 grams, who needed endotracheal intubation and mechanical ventilation were studied. Once the babies reached the criteria for exubation, they were randomized to either nIPPV (n=36) or to nCPAP (n=36) in accordance with the randomization resulted. The inicial settings for those randomized to nIPPV were: rate=12; PIP=16 cm H20; PEEP=6 cm H20; FiO2 < 40%, and for those randomized to nCPAP were P=6 cm H2O; FiO2 < 40%. The study ended after 72 hours or when the infants reached the criteria of failure of the extubation. Ethical Approval was obtained from the Hospital. Results: Most received at least one dose of exogenous surfactant (80,5% in the nIPPV group and 83,3% in the nCPAP group, P= 1). The average time of mechanical ventilation also was similar (6.2 and 7.3 days respectively, P= 0.59). Of the 36 infants randomized to nIPPV, six (16,6%) failed extubation in comparison to 11 (30,5%) of the 36 newborn randomized to nCPAP. Although to have itself observed relative reduction of risk failure of extubation the order of 45% (95%CI: 0,23 to 1,32) in the group nIPPV, this difference did not reach significance statistics. We verified a increaset of failure extubation of 4,38 times in the nCPAP group when compared to the group nIPPV after excluded premature infant from birthweight less than 1000 grams, this difference was significant (P = 0,045). Gastrointestinal and neurological complications, beyond other complications, had no occurred in premature infants submitted to nIPPV or nCPAP after the extubation. Conclusions: Although the distribution of frequencies has numerically shown a lesser index of failure in premature infants submitted to nIPPV in relation to those submitted to nCPAP after extubation they did not have statistical significance difference between the two ways of ventilatory support. To the excluded of the analysis premature infant with birthweight less than 1000 grams, verified an increase significant in the failure extubation in the nCPAP.group .

Page generated in 0.0866 seconds