• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise tridimensional pelo método de elementos finitos do comportamentto biomecânico do incisivo central superior hígido e restaurado com coroa cerâmica utilizando diferentes retentores intra-radiculares / Three-dimensional finite element analyses of biomechanical behavior in a maxillary incisor with all-ceramic crow using different posts

Ribeiro, João Paulo Filgueiras 11 February 2009 (has links)
O objetivo do estudo foi analisar tridimensionalmente, por meio do Método de Elementos Finitos (MEF), o comportamento biomecânico de um incisivo central superior hígido sob condição de oclusão fisiológica e posteriormente comparar com diferentes simulações de situações clínicas de dentes tratados endodonticamente e restaurados com coroas totais cerâmicas, variando a quantidade de remanescente dental e o tipo de retentor intra-radicular (núcleo metálico fundido- NMF, fibras de vidro- RFV e zircônio- RZ). Foram construídos modelos tridimensionais do incisivo central superior sem e com 2 mm de remanescente dentinário na porção coronária. Uma carga de 10 N foi aplicada de forma normal no terço incisal, nas cristas marginais mesial e distal, da superfície palatal. A análise dos dados foi realizada pelo programa computacional NeiNastran® - Noran Engineering, Inc. Os resultados de deslocamento e tensão máxima principal foram obtidos mostrando que houve diferenças significativas na distribuição de tensão entre o dente hígido e o com retentor intra-radicular. O grupo com NMF apresentou o comportamento mais similar ao dente hígido (controle), seguidos do retentor de fibra de vidro com remanescente e sem remanescente dental. Os grupos que apresentaram maior diferença em relação ao controle foram os retentores de zircônia sem e com remanescente de dentina. Considerando- se a presença de remanescente dentinário na porção coronária (2mm) para os grupos restaurados com retentores pré- fabricados, os RFV apresentaram uma redução do estresse na interface dente/restauração em comparação com RZ. Pode-se concluir que a utilização de núcleos metálicos fundidos apresentou comportamento biomecânico mais similar ao dente hígido. / The purpose of this study was to evaluated by three-dimensional finite element analysis the biomechanical behavior of a healthy maxillary central incisor under physiological load comparing with different clinical conditions of endodontically treated teeth restored with all-ceramic crowns, with various remaining tooth structure and post-and-core systems (cast metal post- MP, glass fiber post- GFP and zirconium post- ZP). Three-dimensional models were performed with and without 2 mm of dental remaining in coronary portion. A load of 10 N was applied in normal way at the incisal third of the palatine surface in the mesial and distal marginalis ridges. Data analysis was performed by the computer program NeiNastran ® - Noran Engineering, Inc. The results of maximal stress and displacement demonstrated significant differences in the tensile distribution in healthy (control) and restored tooth. The MP showed similar performance in comparison with healthy tooth, followed by GFP with and without remaining tooth structure. The teeth restored with ZP showed higher difference than control group. This study demonstrated that presence of the coronary remaining dentin (2mm) decreases the stress concentration at the interface crown/restoration using GFP in comparison with ZP. Conclusion that cast metal post can reduce the stress level in maxillary central incisor and showed biomechanical behavior similar than healthy teeth.
2

Análise tridimensional pelo método de elementos finitos do comportamentto biomecânico do incisivo central superior hígido e restaurado com coroa cerâmica utilizando diferentes retentores intra-radiculares / Three-dimensional finite element analyses of biomechanical behavior in a maxillary incisor with all-ceramic crow using different posts

João Paulo Filgueiras Ribeiro 11 February 2009 (has links)
O objetivo do estudo foi analisar tridimensionalmente, por meio do Método de Elementos Finitos (MEF), o comportamento biomecânico de um incisivo central superior hígido sob condição de oclusão fisiológica e posteriormente comparar com diferentes simulações de situações clínicas de dentes tratados endodonticamente e restaurados com coroas totais cerâmicas, variando a quantidade de remanescente dental e o tipo de retentor intra-radicular (núcleo metálico fundido- NMF, fibras de vidro- RFV e zircônio- RZ). Foram construídos modelos tridimensionais do incisivo central superior sem e com 2 mm de remanescente dentinário na porção coronária. Uma carga de 10 N foi aplicada de forma normal no terço incisal, nas cristas marginais mesial e distal, da superfície palatal. A análise dos dados foi realizada pelo programa computacional NeiNastran® - Noran Engineering, Inc. Os resultados de deslocamento e tensão máxima principal foram obtidos mostrando que houve diferenças significativas na distribuição de tensão entre o dente hígido e o com retentor intra-radicular. O grupo com NMF apresentou o comportamento mais similar ao dente hígido (controle), seguidos do retentor de fibra de vidro com remanescente e sem remanescente dental. Os grupos que apresentaram maior diferença em relação ao controle foram os retentores de zircônia sem e com remanescente de dentina. Considerando- se a presença de remanescente dentinário na porção coronária (2mm) para os grupos restaurados com retentores pré- fabricados, os RFV apresentaram uma redução do estresse na interface dente/restauração em comparação com RZ. Pode-se concluir que a utilização de núcleos metálicos fundidos apresentou comportamento biomecânico mais similar ao dente hígido. / The purpose of this study was to evaluated by three-dimensional finite element analysis the biomechanical behavior of a healthy maxillary central incisor under physiological load comparing with different clinical conditions of endodontically treated teeth restored with all-ceramic crowns, with various remaining tooth structure and post-and-core systems (cast metal post- MP, glass fiber post- GFP and zirconium post- ZP). Three-dimensional models were performed with and without 2 mm of dental remaining in coronary portion. A load of 10 N was applied in normal way at the incisal third of the palatine surface in the mesial and distal marginalis ridges. Data analysis was performed by the computer program NeiNastran ® - Noran Engineering, Inc. The results of maximal stress and displacement demonstrated significant differences in the tensile distribution in healthy (control) and restored tooth. The MP showed similar performance in comparison with healthy tooth, followed by GFP with and without remaining tooth structure. The teeth restored with ZP showed higher difference than control group. This study demonstrated that presence of the coronary remaining dentin (2mm) decreases the stress concentration at the interface crown/restoration using GFP in comparison with ZP. Conclusion that cast metal post can reduce the stress level in maxillary central incisor and showed biomechanical behavior similar than healthy teeth.
3

Estudo das tensões em dente restaurado com coroa metalocerâmica e dois formatos de retentores intra-radiculares - método dos elementos finitos. / Finite element analysis of a endodontically treated teeth restored with two different types of post and core systems.

Rocha, Isaac José Peixoto Batinga da 06 November 2000 (has links)
O estudo comparativo da distribuição de tensões de von Mises em dente endodonticamente tratado, com dois formatos de retentores intra-radiculares, pré-fabricado cilíndrico/escalonado e fundido cônico, foi realizado pelo método dos elementos finitos em modelos tridimensionais de caninos superiores com geometria axi-simétrica e restaurados com coroas metalocerâmicas, aplicando-se uma carga oblíqua de 100N com 45 º de inclinação em relação ao seu longo eixo. Os resultados indicaram uma discreta diferença nos dois modelos (formatos) de retentores. O pino escalonado neutralizou mais as cargas no sentido corono-apical e no pino cônico ficou evidenciado o efeito de cunha. / The aim of this study was to compare the von Mises stress distribution on a human canine teeth endodontically treated and restored with two types of post and core. The analysis was made using the three dimensional Finite Element Analysis method. For the analysis was created and axy-simetric structure of the teeth, including a porcelain fused to metal crown, a cement layer, and the periodontal structures. The model was analyzed when a 100N load was applied on the surface of the crown with 45º angulation with the long axis of the teeth. The results showed that both models exhibit little difference, the “stair shape" post system neutralized the axial loads, and the conical shape post showed a wedge effect on the apical third of the root.
4

Análise progressiva da deformação e temperatura na superfície radicular geradas durante tratamento endodôntico e reabilitação de caninos superiores

Amade, Euridsse Sulemane 21 December 2011 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In root filled teeth, the lake of knowledge about potential deleterious of temperature rise and amount of strain generated during endodontic treatment and posterior rehabilitation with different types of intra-radicular posts is common. The produced heat and strain is dissipated on dentin structure, periodontal ligament and alveolar bone. The aim of this in vitro study was to investigate the effects of endodontic treatment and different post systems rehabilitation on the strain and temperature rise in two different root dentin regions. For this experimental investigation, twenty one extracted human canines teeth were sectioned 17 mm from their apex and divided into three groups (n = 7): cast post-and-core, fiber glass post and prefabricated steel post. All teeth were prepared for strain-gage and temperature rise measurement, attaching two strain gages on distal and two thermocouples on mesial root surfaces 2 mm and 10 mm from the crown cervical region. The samples were fixed in a specific apparatus developed for this study and strain and temperature rise were recorded during the following procedures: (1) root canal preparation, (2) Final rinse and drying, (3) obturation process, (4) canal relief, (5) post-space preparation, (6) Post modeling, (7) post trying, and (8) Resin cement curing process (9) Resin cement light curing process. Data were analyzed by oneway to compare both study factors among different procedures and two-way analysis of variance to compare post systems and root region, followed by the Tukey s HSD test ( = 0.05). Obturation process resulted in significantly higher strain values on cervical root region and the post-space preparation on the apical root region. The temperature rise reached in post-space preparation procedure was the most dangerous alteration (4.0 14.9°C), exceeding the critical values (10°C) even with water irrigation. The apical deformation produced in post-space preparation was the highest of the entire rehabilitation process: 473.9, 438.1 and 313.0 μS for fiber glass post, cast post and core and prefabricated steel post respectively. The resin cement light-curing resulted in significantly higher temperature on cervical region for all groups. Within the limitations of this study the following conclusions could be drawn: most evaluated procedures produced low temperature rise and strain values on cervical and apical root surface region, except obturation process, canal relief, post-space preparation and resin cement light-curing phase. Prefabricated steel post, inserted actively, resulted in high strain during the post trying and post cementation. Post-space preparation is a critical procedure and cautions must be taken to improve damage to the surrounding tissues. / Em dentes desvitalizados, há frequentemente falta de preocupação dos profissionais em relação ao potencial deletério da transmissão de calor e deformação na dentina, ligamento periodontal e osso alveolar gerado pela terapia endodôntica e reabilitação com retentores intra-radiculares. O objetivo deste estudo in vitro foi investigar de forma progressiva a deformação e a variação de temperatura geradas durante a realização do tratamento endodôntico e reabilitação com diferentes tipos de retentores intra-radiculares. Para esta análise experimental, vinte e um caninos superiores foram selecionados e divididos em 3 grupos experimentais (n = 7), de acordo com os três tipos de retentores em estudo: PFV, pré-fabricado reforçado com fibra de vidro; NMF, Núcleo metálico fundido em liga de NiCr; MET, retentor pré-fabricado metálico rosqueável. Todos os dentes foram seccionados de modo que permanecesse um remanescente radicular de 17,0 mm de comprimento. As amostras sofreram determinado preparo para permitir a fixação de 2 extensômetros na superfície distal e 2 termopares tipo J na superfície mesial da raiz em 2 regiões distintas: 2,0 mm (região cervical) e 10,0 mm (região apical) abaixo do limite cervical. As amostras foram fixadas em aparato desenhado especificamente para este estudo, possibilitando a mensuração, em tempo real, da deformação e da variação da temperatura durante os seguintes procedimentos: (1) Instrumentação; (2) Irrigação final e secagem; (3) Obturação; (4) Alívio imediato; (5) Preparo do espaço para retentor; (6) Moldagem para NMF; (7) Prova dos retentores; (8) Cimentação adesiva; (9) Fotoativação do cimento. Os valores de deformação foram primeiramente submetidos à Análise de variância fatorial 2-way ANOVA (3X2) seguido pelo teste Tukey HSD (=0,05) e novamente submetidos à Análise de variância fatorial One-Way ANOVA seguido pelo teste Tukey HSD (=0,05). A obturação do canal radicular resultou em valores significativamente altos de deformação na região cervical e o preparo do espaço para retentor na região apical. O intervalo da variação de temperatura alcançada durante o preparo do espaço para retentor foi à alteração mais alarmante (4,0 14,9°C), acima do nível crítico (10°C), mesmo na presença de constante irrigação. A deformação apical produzida nesta mesma etapa foi a maior em todo o processo de reabilitação avaliado: 473,9; 438,1; e 313,0 μS para os grupos PFV, NMF e MET respectivamente. A fotoativação resultou em variação de temperatura na região apical em todos os grupos experimentais, porém seus valores foram abaixo do nível crítico. Pode-se concluir que a maioria dos procedimentos avaliados apresentaram valores baixos de aumento de temperatura e deformação em ambas as regiões cervical e apical, exceto a obturação, o alívio imediato, o preparo do espaço para retentor e a fotoativação do cimento resinoso. O pino metálico pré-fabricado resultou em maiores valores de deformação durante as etapas de prova e cimentação do retentor. O preparo do espaço para retentor constitui etapa crítica e precauções devem ser tomadas para evitar danos mecânicos e biológicos ao dente e as estruturas de suporte adjacentes. / Mestre em Odontologia
5

Resistência à tração de retentores intra-radiculares fundidos sumetidos ao acabamento após cimentação com fosfato de zinco

Iglésias, Michele Andréa Lopes 11 July 2007 (has links)
The refinement of the coronary portion of the intraradicular post cemented constitutes in routine in the clinic. However, the effects of the action of the diamond burn in high rotation on the cement agent are little argued. This study is tested the hypothesis of that the refinement with high rotation an the passed time between the cementation and the accomplishment of the refinement have negative effect in the tensile strength of the intraradicular post cemented in bovine roots. Forty eight bovine roots have been parted with 15mm of length, endodontically treated, confectioned in Cu-Al league, cemented with cement zinc phosphate and divided in 4 experimental groups (n=12). Group A: Without refinement; Group B, C e D submitted the refinement 15, 60 minutes and 24 hours respectively, after the cementation. The assay was carried through in universal machine (EMIC) with speed of 0,5mm/min for all the groups 24 hours after the cementation. The data of tensile strength had been analyzed by the analysis of the variance and test of Bartlet (α=1%). Verified that it did not have significant difference between the groups. Inside of the limitation of this study it can be concluded that the refinement with high rotation and the factor passed time between the cementation and assay did not produce effect of the resistance of the intraradicular posts. / O acabamento da porção coronária do retentor intra-radicular fundido após cimentação constitui-se rotina na clínica odontológica. Entretanto, os efeitos da ação da ponta diamantada em alta rotação sobre o agente cimentante são pouco avaliados. Este estudo testou a hipótese de que o tempo decorrido entre a cimentação e a realização do acabamento com alta rotação tenha efeito negativo na resistência à tração dos retentores intra-radiculares fundidos. Quarenta e oito raízes bovinas foram seccionadas com 15 mm de comprimento, tratadas endodonticamente e divididas aleatoriamente em quatro grupos (n=12): n=A: não submetidos ao acabamento; n=B, C e D submetidos ao acabamento com os tempos de 15, 60 minutos e 24 horas respectivamente, após a cimentação. Os condutos foram moldados pela técnica direta para a obtenção de retentores com 11 mm de comprimento intra-radicular, fundidos em cobre-alumínio, jateados com óxido de alumínio e cimentados com fosfato de zinco. O ensaio de tração foi realizado em máquina universal (EMIC) com velocidade de 0,5mm/min para todos os grupos 24 horas após a cimentação. Os resultados foram submetidos à análise de variância e teste de Bartlet (α=1%). Não houve diferenças estatisticamente significantes na resistência à tração nos grupos controle e os grupos com acabamento após a cimentação, independente do período de espera. Dentro das limitações deste estudo concluiu-se que o acabamento com alta rotação e o tempo decorrido entre a cimentação e o ensaio não produziu efeito sobre a resistência dos retentores intra-radiculares fundidos em cobre-alumínio. / Mestre em Odontologia
6

Estudo das tensões em dente restaurado com coroa metalocerâmica e dois formatos de retentores intra-radiculares - método dos elementos finitos. / Finite element analysis of a endodontically treated teeth restored with two different types of post and core systems.

Isaac José Peixoto Batinga da Rocha 06 November 2000 (has links)
O estudo comparativo da distribuição de tensões de von Mises em dente endodonticamente tratado, com dois formatos de retentores intra-radiculares, pré-fabricado cilíndrico/escalonado e fundido cônico, foi realizado pelo método dos elementos finitos em modelos tridimensionais de caninos superiores com geometria axi-simétrica e restaurados com coroas metalocerâmicas, aplicando-se uma carga oblíqua de 100N com 45 º de inclinação em relação ao seu longo eixo. Os resultados indicaram uma discreta diferença nos dois modelos (formatos) de retentores. O pino escalonado neutralizou mais as cargas no sentido corono-apical e no pino cônico ficou evidenciado o efeito de cunha. / The aim of this study was to compare the von Mises stress distribution on a human canine teeth endodontically treated and restored with two types of post and core. The analysis was made using the three dimensional Finite Element Analysis method. For the analysis was created and axy-simetric structure of the teeth, including a porcelain fused to metal crown, a cement layer, and the periodontal structures. The model was analyzed when a 100N load was applied on the surface of the crown with 45º angulation with the long axis of the teeth. The results showed that both models exhibit little difference, the “stair shape” post system neutralized the axial loads, and the conical shape post showed a wedge effect on the apical third of the root.

Page generated in 0.1108 seconds