• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de protocolo usando ultrassom na remoção de retentores metálicos em dentes multirradiculares

Graça, Izabela Araújo Aguiar 29 September 2016 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-01-20T19:50:53Z No. of bitstreams: 1 Dissertação - Izabela A. A. Graça.pdf: 1036402 bytes, checksum: e2d2c3e3d1023d27bec7ce2606b7398d (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-01-20T19:51:13Z (GMT) No. of bitstreams: 1 Dissertação - Izabela A. A. Graça.pdf: 1036402 bytes, checksum: e2d2c3e3d1023d27bec7ce2606b7398d (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-01-20T19:51:46Z (GMT) No. of bitstreams: 1 Dissertação - Izabela A. A. Graça.pdf: 1036402 bytes, checksum: e2d2c3e3d1023d27bec7ce2606b7398d (MD5) / Made available in DSpace on 2017-01-20T19:51:46Z (GMT). No. of bitstreams: 1 Dissertação - Izabela A. A. Graça.pdf: 1036402 bytes, checksum: e2d2c3e3d1023d27bec7ce2606b7398d (MD5) Previous issue date: 2016-09-29 / Among the techniques employed for the removal of the retainers, the ultrasonic vibration has been the most efficient. There is a lack of studies techniques for removing metal retainers in multirooted teeth. This study evaluated in vitro a removal protocol consisting of making a tunnel in the coronal portion of the retainer and application of ultrasound in this cavity. Forty molars were endodontically treated using single file system with reciprocating movement and filled using thermoplasticized technique, receiving cast intraradicular retainers and being allocated into 4 groups according to the removal protocol: GROUP I - no tunnel and no ultrasonic vibration, GROUP II - without tunnel and ultrasonic vibration in the coronal portion of the core, GROUP III - with tunnel and without ultrasonic vibration and GROUP IV - with tunnel and ultrasonic vibration inside the tunnel. The tensile test was performed on all samples in the EMIC DL-2000 universal testing machine with a speed of 1 mm / min values obtained in Newton and the data were statistically analyzed using ANOVA and Tukey- Kramer (p <0.05). The results showed statistically significant differences between the groups tested (GI - 322.74 N; GII - 283.09 N; GIII - 244.00 N; GIV - 237.69 N). The lowest average power was found in the group that was the ultrasonic vibration inside the tunnel.The results demonstrated that preparing the tunnel in the core and ultrasonic vibration within it reduces the force required for removing. This removal protocol was effective for removal intraradicular metal retainers multirooted teeth cemented with zinc phosphate. / Entre as técnicas empregadas para a remoção dos retentores, a vibração ultrassônica tem sido a mais eficiente. Há uma escassez de estudos de técnicas para remoção de retentores metálicos em dentes multirradiculares. Este trabalho avaliou in vitro um protocolo de remoção que consiste na confecção de um túnel na porção coronária do retentor e aplicação de ultrassom nessa cavidade. Quarenta molares inferiores foram tratados endodonticamente usando sistema de lima única com movimento reciprocante e obturados utilizando a técnica de termocompactação, recebendo retentores intrarradiculares fundidos e sendo alocados em 4 grupos de acordo com o protocolo de remoção: GRUPO I – sem túnel e sem vibração ultrassônica, GRUPO II – sem túnel e com vibração ultrassônica na porção coronária do núcleo, GRUPO III – com túnel e sem vibração ultrassônica e GRUPO IV – com túnel e com vibração ultrassônica no interior do túnel. O teste de tração foi realizado em todas as amostras na Máquina Universal de Ensaio EMIC DL-2000 com velocidade de 1 mm/min obtendo valores em Newton e os dados foram submetidos à análise estatística ANOVA e Tukey- Kramer (p <0.05). Os resultados mostraram diferenças estatisticamente significantes entre os grupos testados (GI - 322,74 N; GII - 283.09 N; GIII - 244,00 N; GIV - 237,69 N).A menor média de força foi encontrada no grupo que ocorreu a vibração ultrassônica no interior do túnel. Os resultados demonstraram que a confecção do túnel no núcleo e vibração ultrassônica no interior dele reduz a força de tração necessária para a remoção. Este protocolo de remoção se mostrou efetivo para remoção de retentores em dentes multirradiculares fixados com fosfato de zinco.
2

Avaliação da eficiência de pontas de ultrassom usada e adaptada na remoção de retentores metálicos

Figueira, Keylla Lopes, 92-99211-2267 27 July 2018 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2018-09-13T13:11:58Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertação final.pdf: 1572687 bytes, checksum: 674c29e0d0506fb0bcb429ddc3a7ef32 (MD5) / Made available in DSpace on 2018-09-13T13:11:58Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertação final.pdf: 1572687 bytes, checksum: 674c29e0d0506fb0bcb429ddc3a7ef32 (MD5) Previous issue date: 2018-07-27 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / This study evaluated in vitro the efficiency of used and adapted ultrasonic tips in the removal of metal retainers. Methods: Forty maxillary canines received Ni-Cr alloy fused metal retainers fixed with zinc phosphate cement. Group I - without ultrasonic vibration, Group II - with ultrasonic vibration using the ST – 09 new tip, Group III - with the ST - 09 used tip (used in 10 previous procedures) and Group IV - with ST – 09 adapted tip fitted with stone mounted. Groups II, III and IV received ultrasonic vibration for one minute with ENAC (Osada Eletric Co., Tokyo, Japan) at maximum frequency. The tensile test was performed on all specimens in the Universal Testing Machine with a speed of 1 mm/min, obtaining values in Newton, the data statistically analyzed using ANOVA and Tukey Test (p <0.05). RESULTS: The results showed statistically significant differences between the groups tested (control group = 472,641 N, new tip = 213,329 N, used tip = 408,185 N and adapted tip = 348,292 N). The lowest mean tensile strength was found in the group where the ultrasonic vibration was applied with the new tip followed by the adapted tip. The results show that the new tip reduces the tensile force required to remove the post cast. Conclusion: The change of the metallic structure of the ultrasonic tip interferes in the ultrasonic efficiency. / Este trabalho comparou in vitro a eficiência de pontas de ultrassom usada e adaptada na remoção de retentores metálicos fundidos. Métodos: Quarenta caninos superiores receberam retentores metálicos fundidos em liga Ni-Cr fixados com cimento de fosfato de zinco. Foram alocados em 4 grupos: Grupo I - sem vibração ultrassônica, Grupo II - com vibração ultrassônica utilizando a ponta ST - 09 nova, Grupo III - com a ponta ST - 09 usada (utilizada em 10 procedimentos anteriores) e Grupo IV - com a ponta ST – 09 adaptada com pedra montada. Os grupos II, III e IV receberam vibração ultrassônica por um minuto com aparelho ENAC (Osada Eletric Co., Tokyo, Japão) em máxima frequência (30 kHz). O teste de tração foi realizado em todos os espécimes na Máquina Universal de Ensaio com velocidade de 1 mm/min obtendo valores em Newton, os valores foram submetidos à análise estatística Anova e Teste Tukey (p<0.05). Resultados: Os resultados mostraram diferenças estatisticamente significantes entre os grupos testados (grupo controle = 472.641 N, ponta nova = 213.329 N, ponta usada = 408.185 N e ponta adaptada = 348.292 N). A menor média de força de tração foi encontrada no grupo que a vibração ultrassônica foi aplicada com a ponta nova, seguida da ponta adaptada. Os resultados evidenciaram que a ponta nova reduz a força de tração necessária para remoção dos retentores metálicos fundidos. Conclusão: A alteração da estrutura metálica da ponta ultrassônica interfere na eficiência ultrassônica.
3

Resistência à fratura de dentes tratados endodonticamente após a cimentação de retentores intrarradiculares / Resistance of endodontically treated teeth after cementation of intracanal posts fracture

Gehrcke, Vanessa de Miranda 27 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-01-19T13:44:07Z No. of bitstreams: 1 vanessademirandagehrcke.pdf: 2230080 bytes, checksum: ea7905ee9904feb66d7f998560117f0d (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-01-25T17:58:19Z (GMT) No. of bitstreams: 1 vanessademirandagehrcke.pdf: 2230080 bytes, checksum: ea7905ee9904feb66d7f998560117f0d (MD5) / Made available in DSpace on 2016-01-25T17:58:19Z (GMT). No. of bitstreams: 1 vanessademirandagehrcke.pdf: 2230080 bytes, checksum: ea7905ee9904feb66d7f998560117f0d (MD5) Previous issue date: 2014-08-27 / O objetivo deste estudo foi avaliar a resistência à fratura de dentes tratados endodonticamente com uma simulada fragilidade no canal e recuperados com a cimentação de retentores intrarradiculares. Foram utilizados 60 caninos humanos com dimensões semelhantes, que tiveram a porção coronária seccionada ao nível da junção cemento-esmalte, padronizando as raízes em 17 mm. Os canais foram preparados por meio de instrumentação rotatória, obturados com cone de guta-percha e cimento AHPlus, sob condensação termomecânica, e incluídas em blocos de resinas autopolimerizável. As raízes foram divididas aleatoriamente em 3 grupos (n=20), de acordo com o material empregado na restauração, sendo: Grupo 1: Pino de fibra de vidro e núcleo com resina composta Z350; Grupo 2: Pino pré-fabricado metálico e núcleo com resina composta Z350; e Grupo 3: Núcleo metálico fundido em liga de Prata. Todas as raízes foram restauradas com copings metálicos e submetidas a ensaio mecânico de compressão a 45 graus em uma máquina universal de ensaios com célula de carga de 500 N e à uma velocidade de 0,5 mm/min. Os valores de resistência à fratura foram submetidos à ANOVA one-way e teste de Tukey com nível de significância de 5% e, para exposição dos resultados foi usado o teste de Exato de Fisher. Não houve diferença estatística significante entre os valores de força para os grupos G1, G2 e G3 (p=0.193). Com relação ao padrão de fratura, o G1 apresentou 55% e o G2 45% de fratura do tipo I, consideradas fraturas reparáveis ou favoráveis, já o G3 apresentou 50% do tipo V, consideradas irreparáveis ou desfavoráveis. Conclui-se que os pinos de fibra de vidro e pinos pré-fabricados metálicos podem ser utilizados na restauração de dentes tratados endodonticamente, pois apresentaram fraturas envolvendo o núcleo de preenchimento, facilitando o reparo. / This study evaluated the fracture resistance of endodontically treated teeth with a simulated fragility in the canal and restored with the cementation of intracanal retainers. Sixty canines human with similar dimensions were used. The coronal portion of each tooth was sectioned at the line cement-enamel junction, standardizing the roots 17 mm. The root canal of each tooth was instrumented using nickel titanium rotary instruments, obturated with gutta-percha and epoxy resin root canal sealer AH Plus using thermoplastic gutta-percha technique, roots were embedded vertically in the centers of auto polymerizing acrylic resin blocks. The roots were randomly divided into three groups (n=20), according to the material used in restoration, as follows: Group 1: Fiber glass post and core with composite resin Z350; Group 2: Prefabricated steel post and core with composite resin Z350; Group 3: Cast Ni-Cr alloy post. All the roots were restored with metal copings and subjected loading at to mechanical compression test at 45 degrees in a universal testing machine, until a force of 500 N and speed of 0.5 mm/min. The value of fracture resistance was analyzed with one-way ANOVA and Tukey’s test, with a significance level of 5%. Chi-squared test was conducted for evaluation of the fracture modes. No significant difference was detected between the values of fracture resistance among group G1, G2 e G3 (p=0.193). According to the fracture mode, the G1 showed 55% and 45% of the G2 type I fracture, considered repairable or favorable fractures, since the G3 showed 50% type V, considered irreparable or unfavorable. It was conclude that the fiberglass and prefabricated steel posts, along with auto polymerized resin cement Multilink can be used in the restoration of endodontically treated teeth, it had fractures involving the core that facilitating repair.

Page generated in 0.1336 seconds