Avaliação de algumas propriedades físico-químicas de alguns materiais retrobturadores / Evaluation of some physicochemical properties of retrograde fillingVivan, Rodrigo Ricci 09 March 2009 (has links)
Foram avaliadas algumas propriedades físico-químicas, como o pH, liberação de íons cálcio, tempo de presa, solubilidade e radiopacidade de 3 cimentos a base do agregado de trióxido mineral, clínquer do cimento Portland e um epóxico experimental. Foram avaliados os cimentos MTA Angelus branco, MTA Bio, cimentos experimentais, MTA fotopolimerizável e Sealepox RP e o Clínquer de cimento Portland acrescido de 20% de óxido de bismuto e 5% de sulfato de cálcio. Para as avaliações do pH e da liberação de íons cálcio foram utilizados tubos de polietileno com 1,0 mm de diâmetro interno e 10,0 mm de comprimento, com apenas uma das extremidades aberta. Esses tubos foram preenchidos com os cimentos e imediatamente imersos em tubos de ensaio contendo 10 mL de água deionizada, onde permaneceram durante todo o período experimental. Realizaram-se avaliações nos períodos de 3, 24, 72 e 168 horas, sempre se renovando a água deionizada ao final de cada período. Os ensaios de tempo de presa, solubilidade e radiopacidade, foram realizados conforme a norma #57 da ADA. Em relação ao tempo de presa, também foi utilizada a agulha de Gilmore de 453,6 g, para a presa final, conforme recomenda a norma #C266-03 da ASTM. Os resultados demonstraram que todos os cimentos apresentaram pH alcalino e liberaram íons cálcio em todos os períodos, com tendência de redução nos períodos finais. Quanto aos tempos de presa, os cimentos MTA Angelus branco e o cimento experimental MTA Bio apresentaram os menores tempos. Já o Clínquer apresentou valores intermediários, e o Sealepox RP, apresentou os tempos mais longos. O cimento MTA fotopolimerizável, por suas características próprias, não foi submetido a esse teste. Em relação ao ensaio de solubilidade, o cimento que mais se aproximou das recomendações da ADA, foi o Sealepox RP, com valores próximos a 1%, enquanto que os cimentos MTA Angelus branco, MTA Bio e o Clínquer acrescido ao radiopacificador e sulfato de cálcio apresentaram valores maiores. O MTA fotopolimerizável apresentou valores menores. Em relação à radiopacidade, a maioria dos cimentos estudados apresentou valores superiores à da dentina, com resultados semelhantes entre si, com exceção do MTA fotopolimerizável, que apresentou valor próximo ao da dentina. / Some properties had been evaluated physicochemical, such as pH, release of calcium ions, setting time, solubility and radiopacity of 3 retrograde filling the base of the aggregate of mineral trioxide, to clínquer of the Portland cement and an experimental epoxy sealer. Experimental cements MTA white Angelus, MTA Bio, light-curing MTA and Sealepox RP and the Clínquer of cement Portland increased of 20% of bismuth oxide and 5% of calcium sulphate had been evaluated. For the evaluations of pH and the release of calcium ions had been used polyethylene pipes with 1,0 mm of internal diameter and 10,0 mm of length, with only one of the extremities open. These pipes had been filled with cements and immediately immersed in pipes of 10 assay I contend mL of distilled water, where they had remained all during the experimental period. Evaluations in the periods of 3, 24, 72 and 168 hours, always if renewing the distilled water to the end of each period. The assays of setting time, solubility and radiopacity, had been carried through in agreement the norm #57 of the ADA. In relation to the setting time, also g was used the needle of Gilmore of 453,6, for the final canine tooth, as it recommends to the norm #C266-03 of the ASTM. The results had demonstrated that all the cements had presented pH alkaline and had liberated calcium ions in all the periods, with trend of reduction in the final periods. How much to the setting time, cements MTA white Angelus and experimental cement MTA Bio had presented the lesser times. Already the Clínquer presented intermediate values, and Sealepox RP, presented the times longest. Light-curing cement MTA, by its proper characteristics, was not submitted to this test. In relation to the solubility assay, the cement that more was come close to the recommendations of the ADA, was Sealepox RP, with next values 1%, whereas cements MTA white Angelus, MTA Bio and the Clínquer increased to the bismuth oxide and calcium sulphate had presented bigger values. The light-curing MTA presented less resulted . In relation to the radiopacity, the majority of studied cements presented more values to the one of the dentine, with similar results between itself, exception of the light-curing MTA, that presented value next to the one to the dentine.
|
2 |
Avaliação de algumas propriedades físico-químicas de alguns materiais retrobturadores / Evaluation of some physicochemical properties of retrograde fillingRodrigo Ricci Vivan 09 March 2009 (has links)
Foram avaliadas algumas propriedades físico-químicas, como o pH, liberação de íons cálcio, tempo de presa, solubilidade e radiopacidade de 3 cimentos a base do agregado de trióxido mineral, clínquer do cimento Portland e um epóxico experimental. Foram avaliados os cimentos MTA Angelus branco, MTA Bio, cimentos experimentais, MTA fotopolimerizável e Sealepox RP e o Clínquer de cimento Portland acrescido de 20% de óxido de bismuto e 5% de sulfato de cálcio. Para as avaliações do pH e da liberação de íons cálcio foram utilizados tubos de polietileno com 1,0 mm de diâmetro interno e 10,0 mm de comprimento, com apenas uma das extremidades aberta. Esses tubos foram preenchidos com os cimentos e imediatamente imersos em tubos de ensaio contendo 10 mL de água deionizada, onde permaneceram durante todo o período experimental. Realizaram-se avaliações nos períodos de 3, 24, 72 e 168 horas, sempre se renovando a água deionizada ao final de cada período. Os ensaios de tempo de presa, solubilidade e radiopacidade, foram realizados conforme a norma #57 da ADA. Em relação ao tempo de presa, também foi utilizada a agulha de Gilmore de 453,6 g, para a presa final, conforme recomenda a norma #C266-03 da ASTM. Os resultados demonstraram que todos os cimentos apresentaram pH alcalino e liberaram íons cálcio em todos os períodos, com tendência de redução nos períodos finais. Quanto aos tempos de presa, os cimentos MTA Angelus branco e o cimento experimental MTA Bio apresentaram os menores tempos. Já o Clínquer apresentou valores intermediários, e o Sealepox RP, apresentou os tempos mais longos. O cimento MTA fotopolimerizável, por suas características próprias, não foi submetido a esse teste. Em relação ao ensaio de solubilidade, o cimento que mais se aproximou das recomendações da ADA, foi o Sealepox RP, com valores próximos a 1%, enquanto que os cimentos MTA Angelus branco, MTA Bio e o Clínquer acrescido ao radiopacificador e sulfato de cálcio apresentaram valores maiores. O MTA fotopolimerizável apresentou valores menores. Em relação à radiopacidade, a maioria dos cimentos estudados apresentou valores superiores à da dentina, com resultados semelhantes entre si, com exceção do MTA fotopolimerizável, que apresentou valor próximo ao da dentina. / Some properties had been evaluated physicochemical, such as pH, release of calcium ions, setting time, solubility and radiopacity of 3 retrograde filling the base of the aggregate of mineral trioxide, to clínquer of the Portland cement and an experimental epoxy sealer. Experimental cements MTA white Angelus, MTA Bio, light-curing MTA and Sealepox RP and the Clínquer of cement Portland increased of 20% of bismuth oxide and 5% of calcium sulphate had been evaluated. For the evaluations of pH and the release of calcium ions had been used polyethylene pipes with 1,0 mm of internal diameter and 10,0 mm of length, with only one of the extremities open. These pipes had been filled with cements and immediately immersed in pipes of 10 assay I contend mL of distilled water, where they had remained all during the experimental period. Evaluations in the periods of 3, 24, 72 and 168 hours, always if renewing the distilled water to the end of each period. The assays of setting time, solubility and radiopacity, had been carried through in agreement the norm #57 of the ADA. In relation to the setting time, also g was used the needle of Gilmore of 453,6, for the final canine tooth, as it recommends to the norm #C266-03 of the ASTM. The results had demonstrated that all the cements had presented pH alkaline and had liberated calcium ions in all the periods, with trend of reduction in the final periods. How much to the setting time, cements MTA white Angelus and experimental cement MTA Bio had presented the lesser times. Already the Clínquer presented intermediate values, and Sealepox RP, presented the times longest. Light-curing cement MTA, by its proper characteristics, was not submitted to this test. In relation to the solubility assay, the cement that more was come close to the recommendations of the ADA, was Sealepox RP, with next values 1%, whereas cements MTA white Angelus, MTA Bio and the Clínquer increased to the bismuth oxide and calcium sulphate had presented bigger values. The light-curing MTA presented less resulted . In relation to the radiopacity, the majority of studied cements presented more values to the one of the dentine, with similar results between itself, exception of the light-curing MTA, that presented value next to the one to the dentine.
|
3 |
Análise "in vitro" da microinfiltração em retrobturação, utilizando diferente materiais retrobturadores e a influência da aplicação da Edta na cavidade retrógradaPelissari, Carlos Antonio 21 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1
Carlos Antonio Pellissari.pdf: 1778484 bytes, checksum: 53efb541915c3a7f2e9f0a102717239b (MD5)
Previous issue date: 2004-07-21 / Although reaching high success rates there is a great number of root canals endodontically treated which don’t reach the wished results. In these cases there is
necessity to indicate the periapical surgery. Among the surgical kinds the most used is the conventional retrograde filling. This surgical modality has also impelled the main researches about the matter.The present study had the purpose to evaluate “in vitro”the microleakage when were used some retrofilling materials and also the influence of application of EDTA in the retrograde cavity before to be filled the canals.
They were used in this study seventy two mandibular and maxillary human canine teeth extracted for several reasons in Surgical Clinic of State University – Ponta Grossa – Pr – Brazil. Initially all teeth were instrumented and filled according to traditional technics of preparation and filling. After this the teeth had the apical portion
sectioned perpendicularly to tooth long axis and its external surface was made waterproof. After the apicectomy they were prepared cavities of approximately 3 mm
deep using the sonic equipment GNATUS ( JET- SONIC FOUR) with the point S12 with the angle of 90 with the active point with diamond with 3 mm long and a caliber
compatible to the most of teeth. The seventy two teeth were fortuitously distributed in six groups with twelve teeth each one according to the materials to be used. In three groups before the retrograde filling it was made an application of EDTA during 3 minutes in retrograde cavity. According to the procedures and the materials used in
retrofillings the six groups were so constituted: Group I – retrofilling with Sealapex+zinc oxide eugenol; Group II – retrofilling with IRM; Group III – retrofilling
with MTA; Group IV – application of EDTA and retrofilling with Sealapex+zinc oxide eugenol; Group V – application of EDTA and retrofilling with IRM; Group VI – application of EDTA and retrofilling with MTA. After the operative procedures and drying of the roots these were imersed in 2 methilene solution during sixty hours at 37C. After this period the roots were washed in current water during 12 hours and the proofing layer was removed. It was performed them the longitudinal wearing of the root till the exposition of the retrofilling material making possible the analysis of the leakage. To verify the extension of the leakage the teeth were photographed with digital camera and the images transported to the computer where they were analysed in a specific program called Mocha to measure the apical microleakage. The leakage
was measured from a root end to the more depth of leakage observed. The values of the leakages of each tooth in milimeters and the overages of the leakages were duly
ordered and submited to the statistical analysis from which we conclude: There wasn’t influence when it was applicated the EDTA in retrograde cavity before the use of the retrofilling materials evaluated; There are statistically significative differences when the
groups of retrofilling materials were compared and when the application of EDTA alone was analysed; The retrofilling material IRM presents the most degree of
marginal leakage; MTA was shown to be the best among the evaluated materials; Sealapex+zinc oxide eugenol didn’t present significative difference in relation to MTA;
EDTA used in retrograde cavity increased the degree of microleakage. / Embora atingindo altos índices de sucesso, há um grande número de canais radiculares, tratados endodonticamente, que não atingem os resultados desejados.Nesses casos há a necessidade da indicação da cirurgia parendodôntica.
Dentre as modalidades cirúrgicas a mais empregada ainda é a obturação retrógrada convencional. Essa modalidade cirúrgica tem motivado também a maioria das pesquisas. O presente trabalho teve como objetivo a análise “in vitro”da
microinfiltração, quando se utilizaram alguns materiais retrobturadores e também a influência da aplicação de EDTA na cavidade retrógrada, antes de serem retrobturados os canais. Foram utilizados no presente trabalho 72 dentes caninos humanos superiores e inferiores permanentes, extraídos por diversos motivos, na Clínica de Cirurgia da Universidade Estadual de Ponta Grossa. Inicialmente todos os
dentes foram instrumentados e obturados, segundo técnicas tradicionais de preparo e obturação. Após isso os dentes tiveram a porção apical seccionada perpendicularmente em relação ao longo eixo do dente e sua superfície externa
impermeabilizada. Após a apicectomia foram confeccionadas cavidades de aproximadamente 3 mm de profundidade, utilizando-se o aparelho de ultra-som Gnatus (Jet – Sonic Four) com a ponta S12, com ângulo de 90, com ponta ativa
diamantada com 3 mm de comprimento e um calibre que se aplica à maioria dos canais. Os 72 dentes foram então distribuídos aleatoriamente em 6 grupos experimentais com 12 dentes cada um, segundo os materiais a serem utilizados. Em
3 grupos, antes da obturação retrógrada, foi feita a aplicação de EDTA, por 3 minutos, na cavidade retrógrada. De acordo com os procedimentos e materiais utilizados na retrobturação, os 6 grupos experimentais foram assim constituídos:
Grupo I – Retrobturação com Sealapex + óxido de zinco e eugenol; Grupo II – Retrobturação com IRM; Grupo III – Retrobturação com MTA; Grupo IV – Aplicação de EDTA e retrobturação com Sealapex+óxido de zinco e eugenol; Grupo V – Aplicação de EDTA e retrobturação com IRM; Grupo VI – Aplicação de EDTA e retrobturação com MTA. Após a realização dos procedimentos operatórios e a secagem das raízes, essas foram imersas em solução de azul de metileno a 2%,por 60 horas a 37C.Decorrido esse período as raízes foram lavadas durante 12 horas em água corrente e a camada impermeabilizante removida. Realizou-se então o desgaste longitudinal da raiz no sentido vestíbulo-lingual até a exposição do material retrobturador, possibilitando assim a análise da infiltração do corante. Para verificação da extensão da penetração da solução corante os dentes foram fotografados com uma câmara fotográfica digital e as imagens levadas ao computador, onde foram analisadas em um programa específico chamado Mocha, para medir a microinfiltração apical. A infiltração foi medida a partir do extremo apical radicular, até a maior profundidade de infiltração observada. Os valores em milímetros das infiltrações de cada dente e as médias das infiltrações foram
devidademente tabulados e submetidos à análise estatística, levando-nos às seguintes conclusões: Não houve influência da aplicação do EDTA na cavidade, antes do uso dos materiais retrobturadores avaliados; Existem diferenças
estatisticamente significantes, quando comparados os grupos de materiais retrobturadores e quando analisada a aplicação do EDTA isoladamente; O material retrobturador IRM apresenta o maior grau de infiltração marginal; O MTA mostrou-se ser o melhor entre os materiais avaliados; O Sealapex+Óxido de zinco e eugenol não apresentou diferença significativa em relação ao MTA; O EDTA, utilizado na
cavidade retrógrada, provocou um aumento no grau de infiltração.
|
4 |
Análise de uma nova ponta ultrassônica para agitação do irrigante em preparos retrógrados / Assessment of a new ultrasonic tip for irrigant agitation in root-end cavity preparationsValencia, Yahir Muñoz 13 March 2019 (has links)
O objetivo desde estudo foi avaliar a eficiência de remoção de smear layer e a influência da resistência de união de cimentos de silicato de cálcio de um novo inserto ultrassônico para agitação do irrigante em preparos retrógrados. Metodologia Foram selecionados 112 caninos unirradiculados, que foram formatados e obturados de forma convencional com a subsequente ressecção apical. Seguidamente, foram conformados 4 grupos de avaliação, ultra-som/solução salina; convencional/solução salina; ultra-som/EDTA17% e convencional/EDTA17%. Para analisar a remoção do smear layer, 72 espécimes foram divididos em 4 grupos (n=18), e retroprepararados utilizando uma ponta ultrassônica. Os espécimes foram clivados, obtendo-se dois segmentos iguais (mesial e distal). Os segmentos retrocavitários foram observados através da microscopia eletrônica de varredura (MEV), a partir de três regiões representativas a 250x, obtendo-se imagens correspondentes à pré-irrigação. Posteriormente, foram executados os protocolos de irrigação e novamente obtidas imagens representativas da pós-irrigação. Para o teste de push-out, 40 dentes alocados em 4 grupos (n=10) foram empregados, conforme os diferentes protocolos de irrigação previamente mencionados. Os espécimes foram retrobturados e a obtenção dos corpos-de-prova realizada a partir de um novo seccionamento apical de 2mm±0.1 de cada espécime. A resistência de união foi determinada por meio de uma máquina de ensaios mecânicos e o tipo de falha foi determinado por meio de MEV. Os dados foram comparados por meio dos testes de Kruskal-Wallis e Dunn para a remoção de smear layer e ANOVA e Tukey no teste de push-out. Resultados O grupo ultrassom/EDTA17% removeu significativamente uma maior quantidade do smear layer, observando-se uma maior porcentagem de túbulos dentinários abertos em comparação com os outros grupos (P < 0.05). Na resistência de união, o grupo ultrasom/ EDTA17% mostrou os maiores valores na resistência de união (6.42±0.69) seguido pelos grupos convencional/EDTA17%, ultra-som/solução salina e convencional/solução salina respectivamente (P < 0.05). O padrão de falha adesivo foi o mais predominante, enquanto que no grupo ultrassom/EDTA17% foi preponderantemente mista (8/10). Conclusões O novo inserto ultrassônico para ativação do irrigante promoveu uma maior remoção de smear layer além de favorecer maior resistência de união do material retrobturador às paredes dentinárias em preparos retrógrados, principalmente se associado ao EDTA17%. / To evaluate the smear layer removal capacity and its influence on the bond strength of a calcium silicate-based cement of a new ultrasonic tip for irrigant agitation in rootend cavity preparations. Methods: One hundred and twelve maxillary and mandibular canines were chemomechanically instrumented, root filled and the root apexes resected. Specimens were randomly distributed into 4 experimental groups: ultrasonic/saline solution; conventional/ saline solution; ultrasonic/EDTA 17% and conventional/EDTA solution 17%. The analysis of the smear layer removal employed seventy-four specimens divided into 4 groups (n=18), and the retrograde cavities were prepared using an ultrasonic tip. Next, the specimens were split longitudinally and obtained two halves (mesial and distal). Scanning electron microscopy (SEM) was used to examine and score the internal surfaces for dentinal tubule opening before and after to perform the irrigation protocols. Images were taken at three representative areas with a magnification of 250x. The push-out test employed forty specimens allocated in four groups (n=10), according to the different irrigation protocols previously described. The specimens were retrofilled, sectioned perpendicularly and obtained apical slices at 2mm±0.1 from the apex. Each disc/dentin/retrofilling material was placed in a testing machine for the bond strength measurement and the failure mode was observed by SEM. The smear layer removal data were analysed and compared using Kruskal-Wallis and Dunn. Push-out data were analysed using ANOVA and Tukey\'s test. Results The ultrasonic/EDTA 17% group removed the smear later more effectively, and showed the best tubule opening condition than the others three groups. (P < 0.05). Ultrasonic/EDTA 17% group demonstrated the highest mean bond strength values (6.42±0.69) compared with conventional/EDTA, ultrasonic/saline solution and conventional/saline solution, respectively (P < 0.05). Most failure modes were predominantly adhesive (55%), whereas in the ultrasonic/EDTA 17% group was mixed (80%). Conclusion The new ultrasonic tip for irrigant agitation showed higher percentage of smear layer removal and improved the push-out bond strength of the retrograde root filling to the root-end dentine surfaces, mainly when associated to EDTA 17%.
|
Page generated in 0.0732 seconds