Management of produced water in oil and gas operations

Patel, Chirag V. 17 February 2005 (has links)
Produced water handling has been an issue of concern for oil and gas producers as it is one of the major factors that cause abandonment of the producing well. The development of effective produced water management strategies poses a big challenge to the oil and gas industry today. The conversion of produced water into irrigation or fresh water provides a cost effective tool to handle excessive amounts of the produced water. In this research we proposed on-site produced water treatment units configured to achieve maximum processing throughput. We studied various advanced separation techniques to remove oil and dissolved solids from the produced water. We selected adsorption as the oil removing technique and Reverse Osmosis (RO) as the dissolved solids removing technique as being the best for our purpose. We performed experiments to evaluate operating parameters for both adsorption and RO units to accomplish maximum removal of oil and dissolved solids from the produced water. We compared the best models fitting the experimental data for both the processes, then analyzed and simulated the performance of integrated produced water treatment which involves adsorption columns and RO units. The experimental results show that the adsorption columns remove more than 90% of the oil and RO units remove more than 95% of total dissolved solids from the produced water. The simulation results show that the proper integration and configuration of adsorption and RO units can provide up to 80% efficiency for a processing throughput of 6-8 gallons per minute of produced water. From an oil and gas producer’s viewpoint output from the produced water treatment system is a revenue generating source. The system is flexible and can be modified for the applications such as rangeland restoration, reservoir recharge and agricultural use.
52

Control of silica scaling phenomena in reverse osmosis systems

Pacheco Rodriguez, Rocio Idalia 28 August 2008 (has links)
Not available / text
53

Improving recovery in reverse osmosis desalination of inland brackish groundwaters via electrodialysis

Walker, William Shane, 1981- 09 November 2010 (has links)
As freshwater resources are limited and stressed, and as the cost of conventional drinking water treatment continues to increase, interest in the development of non-traditional water resources such as desalination and water reuse increases. Reverse osmosis (RO) is the predominant technology employed in inland brackish groundwater desalination in the United States, but the potential for membrane fouling and scaling generally limits the system recovery. The general hypothesis of this research is that electrodialysis (ED) technology can be employed to minimize the volume of concentrate waste from RO treatment of brackish water (BW) and thereby improve the environmental and economic feasibility of inland brackish water desalination. The objective of this research was to investigate the performance sensitivity and limitations of ED for treating BWRO concentrate waste through careful experimental and mathematical analysis of selected electrical, hydraulic, and chemical ED variables. Experimental evaluation was performed using a laboratory-scale batch-recycle ED system in which the effects of electrical, hydraulic, and chemical variations were observed. The ED stack voltage showed the greatest control over the rate of ionic separation, and the specific energy invested in the separation was approximately proportional to the applied voltage and equivalent concentration separated. An increase in the superficial velocity showed marginal improvements in the rate of separation by decreasing the thickness of the membrane diffusion boundary layers. A small decrease in the nominal recovery was observed because of water transport by osmosis and electroosmosis. Successive concentration of the concentrate by multiple ED stages demonstrated that the recovery of BWRO concentrate could significantly improve the overall recovery of inland BWRO systems. A mathematical model for the steady-state performance of an ED stack was developed to simulate the treatment of BWRO concentrates by accounting for variation of supersaturated multicomponent solution properties. A time-dependent model was developed that incorporated the steady-state ED model to simulate the batch-recycle experimentation. Comparison of the electrical losses revealed that the electrical resistance of the ion exchange membranes becomes more significant with increasing solution salinity. Also, a simple economic model demonstrated that ED could feasibly be employed, especially for zero-liquid discharge. / text
54

How to Lower the Levels of Arsenic in Well Water: What Choices do Arizona Consumers Have?

Artiola, Janick F, Wilkinson, Sarah T 03 1900 (has links)
10 pp. / Arsenic levels are often above drinking water standards in Arizona groundwater, at levels that may affect health. Private well owners are responsible for testing and treating they own water. This publication gives an overview of arsenic well water and discusses home water treatment options, including detailed descriptions of distillation, reverse osmosis, and iron filters to lower arsenic and other common water constituents in drinking water.
55

Removal of bacteria by reverse osmosis method.

Anyahuru, Emmanuel Achonna. January 1972 (has links)
No description available.
56

Water treatment by reverse osmosis.

Trivedi, Chandra Shekhar. January 1971 (has links)
No description available.
57

The Development of a Synthesis Approach for Optimal Design of Seawater Reverse Osmosis Desalination Networks

Alnouri, Sabla 2012 August 1900 (has links)
This work introduces a systematic seawater reverse osmosis (SWRO) membrane network synthesis approach, based on the coordinated use of process superstructure representations and global optimization. The approach makes use of superstructure formulations that are capable of extracting a globally optimal design as a performance target, by taking into consideration desired process conditions and constraints that are typically associated with reverse osmosis systems. Thermodynamic insights are employed to develop lean network representations so that any underperforming solutions can be eliminated a priori. This essentially results in considerable improvement of the overall search speed, compared to previously reported attempts. In addition, the approach enables the extraction of structurally different design alternatives. In doing so, distinct membrane network design classes were established by partitioning the search space, based on network size and connectivity. As a result, corresponding lean superstructures were then systematically generated, which capture all structural and operational variants within each design class. The overall purpose is thus to enable the extraction of multiple distinct optimal designs, through global optimization. This mainly helps provide design engineers with a better understanding of the design space and trade-offs between performance and complexity. The approach is illustrated by means of a numerical example, and the results obtained were compared to previously related work. As anticipated, the proposed approach consistently delivered the globally optimal solutions, as well as alternative efficient design candidates attributed to different design classes, with reduced CPU times. This work further capitalizes on the developed representation, by accounting for detailed water quality information, within the SWRO desalination network optimization problem. The superstructures were modified to incorporate models that capture the performance of common membrane elements, as predicted by commercially available simulator tools, e.g. ROSA (Dow) and IMSDesign (Hydranautics). These models allow tracing of individual components throughout the system. Design decisions that are supported by superstructure optimization include network size and connectivity, flow rates, pressures, and post treatment requirements. Moreover, a detailed economic assessment capturing all the significant capital and operating costs associated in SWRO processes, including intake, pre and post treatment has also been accounted for. These modifications were then illustrated using a case study involving four seawater qualities, with salinities ranging from 35 to 45 ppt. The results highlight the dependency of optimal designs on the feed water quality involved, as well as on specified permeate requirements.
58

Composite fouling of calcium sulfate and calcium carbonate in a dynamic seawater reverse osmosis unit

Wang, Yuan, School of Chemical Engineering & Industrial Chemistry, UNSW January 2005 (has links)
Deposition of calcium carbonate (CaCO3) and calcium sulfate (CaSO4) causes serious processing problems and limits the productivity of seawater reverse osmosis (RO) desalination. The interactions between CaSO4 and CaCO3 in the dynamic seawater RO systems have been neglected previously because conventional studies mainly focused on individual compounds or mixed compounds in batch systems. The present work evaluates composite fouling behavior of CaSO4 and CaCO3 in a dynamic RO unit. The fouling experiments were performed at constant pressure and velocity by a partial recycling mode which permeate was withdrawn from the system during the recirculation of retentate to simulate the increasing of water recovery level. The fouling phenomena were monitored by the decline of flux. Scanning electron microscopy (SEM) with a combination of elemental dispersive x-ray microanalysis (EDS), and x-ray powder diffraction (XRD) was used to identify the morphological features, chemical compositions and crystalline phases of foulants. The interactions of CaSO4 and CaCO3 were investigated by the comparison between individual CaSO4 or CaCO3 fouling and composite fouling, and by varying SO42-/HCO3- molar ratio of the feed. A recently developed approach, Scaling Potential Index (SPI) incorporated with measured concentration polarization modulus (CP), for assessing the fouling tendency of inorganic salts on the membrane surface was validated in the dynamic tests. In addition, the effectiveness of two generic scale inhibitors, polyacrylic acid (molecular weight =2100, PA) and sodium hexametaphosphate (SHMP) were evaluated. Some of the highlights of the obtained results are as follows: ??????The precipitation kinetics, morphology and adhesive strength of composite scales were different from pure precipitates ??????CaSO4 precipitated as gypsum while CaCO3 precipitated as two crystalline phases: calcite and aragonite ??????The crystalline phases as well as precipitation kinetics were affected by SO42-/HCO3- ratio ??????Scaling Potential Index was able to predict the fouling tendency of CaSO4 and CaCO3 accurately ??????The dosage of PA and SHMP was effective to mitigate fouling Results of this work are significant, not only because they have made contribution to the fundamental understanding of composite inorganic fouling in RO membrane systems which was ignored previously, but also because they may play a key role in the development of scale control.
59

Performance of water recycling technologies

Al-rifai, Jawad Hilmi. January 2008 (has links)
Thesis (Ph.D.)--University of Wollongong, 2008. / Typescript. Includes bibliographical references.
60

Membrane filtration : fouling and cleaning in forward osmosis, reverse osmosis, and ultrafiltration membranes

Siddiqui, Farrukh Arsalan January 2017 (has links)
A comparison of fouling in osmotically driven processes with that in pressure driven processes is the main focus of the thesis. Forward osmosis (FO) and reverse osmosis (RO) have received considerable attention for water treatment and seawater desalination. This research compared the nature of fouling in FO mode with that in RO starting with the same initial flux in connection with cleaning effects and then comparing to those in ultrafiltration membranes. In all cases, with cleaning as an integral part, the extent of fouling reversibility, and the question whether a critical flux could be determined were examined. The work during the first phase (undertaken at Oxford) quantified the removal of reversible fouling through rinsing by cold and hot water for a range of concentrations using the foulants dextran and carboxymethyl cellulose. The flux-TMP relationship was conventionally compared to that of the clean water flux. The later phase (at Singapore) compared the fouling in FO and RO by alginate in terms of multiple parameters using cellulose tri acetate (CTA) and thin film composite (TFC) membranes. Silica and alginate were selected as model foulants. Whilst experimental water flux profiles in the present study did not exhibit significant differences in trend between FO and RO fouling, foulant resistance for FO was found to be increasingly greater than for RO with the progression of the fouling tests. This was further corroborated by membrane autopsies post fouling tests; both foulant mass deposition density and specific foulant resistance for FO were greater than for RO. The analysis clearly revealed that FO is essentially more prone to fouling than RO which was presumably due to less flux decline in FO (or greater average flux) as compared to that in RO in result of ICP-self compensation effect which is opposite to the prevailing claim in the literature. Additionally, the present study did not find evidence that hydraulic pressure in RO has a role in foulant layer compaction. FO membrane fouling by real waters was the focus of the final phase of the research at SMTC. Pilot scale FO experiments were conducted on spiral wound CTA membrane with treated waste water obtained from a NEWater factory (Singapore) as the feed. In the second stage, experiments were repeated at bench scale with membrane coupons taken from the spiral wound membranes used earlier. The key finding was that the mass transfer coefficients in the Spiral-Wound module were around 50% lower than the corresponding values in the flat sheet unit and this severely limited the fluxes. The reason could be attributed to strong internal concentration polarisation in the former, where tightly wound spacers act to increase the structural parameter.

Page generated in 0.0719 seconds