• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 1
  • 1
  • Tagged with
  • 20
  • 20
  • 20
  • 20
  • 16
  • 15
  • 14
  • 13
  • 9
  • 9
  • 8
  • 7
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Modelagem dinâmica e controle de um gerador tipo DFIG em redes de distribuição

Ávila, Manuel Ricardo Vargas January 2014 (has links)
Neste momento o Brasil possui uma das mais renováveis matrizes energéticas do mundo, mas o desafio de reduzir os níveis de emissão, permitir o crescimento econômico e atender a aproximadamente um milhão de pessoas sem energia elétrica no pais, requer a pesquisa e o desenvolvimento de novas tecnologias que possibilitem a utilização de fontes limpas e sustentáveis de energia, como é a energia eólica. A energia eólica é considerada, entre as alternativas renováveis existentes, a mais viável no mercado de energia, devido à baixa relação custo/benefício de exploração, tendo apresentado um crescimento exponencial ao longo dos anos. Os principais sistema eólicos classificam-se de acordo com sua operação em dois tipos: sistemas com operação a velocidade fixa e sistemas com operação a velocidade variável. Durante muitos anos a liderança do mercado foi para os geradores que operam a velocidade fixa, sendo a máquina mais usada o gerador de indução de rotor em gaiola (SCIG). A partir do ano 2000, a supremacia no mercado passou a ser para o gerador de velocidade variável. Hoje, tem-se dois tipos de geradores amplamente utilizados em sistemas eólicos que operam a velocidade variável: o gerador síncrono e o gerador de indução com rotor bobinado. Neste trabalho será estudada uma das máquinas que operam a velocidade variável e utilizam geradores de indução com rotor bobinado: o gerador de indução duplamente alimentado (DFIG). Sua importância é principalmente o controle independente da potência ativa e da potência reativa fornecida para a rede elétrica, e à operação com máxima eficiência na conversão de energia. Neste contexto, este trabalho apresenta uma análise comparativa de um sistema de geração utilizando máquinas do tipo DFIG com quatro estratégias de controle: controle da potência ativa e da tensão nos terminais da máquina, controle da potência reativa e da tensão nos terminais da máquina, controle da velocidade de rotação e da tensão nos terminais da máquina, controle da potência ativa e da potência reativa fornecidas pela máquina ao sistema. Esta análise é feita comparando o comportamento do sistema quando sujeito a diversas situações, tais como: variações da demanda de potência da carga elétrica, variações do torque mecânico e ocorrência de uma falta trifásica. O desempenho de sistemas de geração eólica com SCIG também é incluído nesta análise para ilustrar de maneira quantitativa os ganhos obtidos com o uso do DFIG. Os resultados obtidos ilustram as virtudes de cada uma das diferentes possibilidades de modos de operação do DFIG em um sistema de distribuição e permitem uma melhor compreensão da vantagem do desempenho do DFIG em relação à utilização do SCIG. / At present Brazil has one of the most renewable energy matrices in the world, but the challenge of reducing emission levels, allowing the economic growth, and helping about 1 million people without electric energy in the country, requires research and development of new technologies that enable the use of clean and sustainable energy sources, such as wind power. Wind energy is considered among the existing renewable alternatives the more viable in the energy market, due to the low cost / benefit ratio of exploitation, having experienced exponential growth over the years. The wind system are classified according to their operation into two types: operating systems with fixed speed and systems with variable speed operation. For many years the leadership in the market was for fixed speed generator, being the most used machine, the induction generator rotor cage (SCIG). From 2000, the leadership in the market was for variable speed wind turbine. Today, there are two types of wind generators widely used in systems that operate at variable speed: synchronous generator and generator with wound rotor induction. In this work we will study one of the machines that operate at variable speed and use induction generators with wound rotor: the doubly-fed induction generator (DFIG). Its importance is mainly the independent control of active power and reactive power supplied to the grid, and operating at maximum efficiency in energy conversion. In this context, this work presents a comparative analysis of a generation system using DFIG type machines with four control strategies: control of active power and voltage at the terminals of the machine, control of reactive power and voltage at the machine terminals, control the rotational speed and tension in the machine terminals, control of active power and reactive power supplied by the machine. This analysis is done by comparing the behavior of the system when subjected to various situations, such as variations in power demand of electric load, changes in the mechanical torque and the occurrence of a three-phase fault. The performance of wind power generation systems with SCIG is also included in this analysis to illustrate quantitatively the gains obtained using DFIG. The results illustrate the virtues of each of the different possible operating modes of the DFIG in a distribution system and allow a better understanding of the performance advantage of the machine DFIG over the use of the machine SCIG.
12

Diretrizes analíticas para projeto de geradores de indução de rotor tipo gaiola de esquilo

Nascimento, Carlos Sonier Cardoso do January 2014 (has links)
Comumente, as máquinas de indução são projetadas para atuarem como motores. Assim, a presente tese objetiva estudar, analisar e construir um protótipo de máquina de indução concebida para atuar, exclusivamente, como gerador de indução, ou seja, impulsionada acima da velocidade síncrona. As características operacionais ideais em regime permanente são elaboradas intentando diretrizes de projeto. Concomitantemente, o estudo apresenta e investiga modelagens analíticas obtidas por parâmetros concentrados e, também, modelagens numéricas realizadas pelo método dos elementos finitos. Para isto, um gerador de indução trifásico de 2,2 kW tem o rotor do tipo gaiola de esquilo com ranhuras assimétricas projetado e prototipado. O protótipo do gerador de indução visa melhores características de desempenho como o fator de potência e menores perdas, por exemplo, que uma máquina de indução de mesma potência projetada para atuar como motor, mas funcionando como gerador interligado à rede em regime permanente. Os resultados analíticos, numéricos e experimentais em regime permanente do protótipo do gerador de indução e de um motor de indução de mesma potência, mas funcionando como gerador interligado à rede, são apresentados e comparados. Os resultados experimentais obtidos mostram valores nominais de 0,77 e 83,04% de fator de potência e rendimento, respectivamente, para o funcionamento da máquina convencional no ponto de operação próximo ao valor de corrente nominal. Para a máquina de indução projetada como gerador, os valores nominais de 0,82 e 81,35% de fator de potência e rendimento, respectivamente, foram obtidos no ponto de operação próximo ao valor de corrente nominal. / Commonly, induction machines are designed to act as motors. Thus, the present thesis aims to study, analyze and build a prototype of an induction machine designed to work exclusively as induction generator, i.e. driven above synchronous speed. The optimal steady state operating characteristics are elaborated by bringing design guidelines. Concomitantly, this study investigates and presents analytical modeling obtained by lumped parameters and also numerical modeling carried out by the finite element method. Thus, a three-phase squirrel cage induction generator of 2.2 kW with asymmetric rotor slots has designed and prototyped. The prototype of the induction generator aims best performance characteristics such as power factor, for example, than an induction machine of the same power designed to act as a motor, but functioning as generator parallel with the grid. Analytical, numerical and experimental results in steady state operation of the induction generator prototype and of an induction motor of the same power, but functioning as generator parallel with the grid, are presented and compared. The experimental results show nominal values 0.77 and 83.04% of power factor and efficiency, respectively, for the conventional machine in the operating point close to the value of rated current. For the induction machine designed as a generator, the nominal values 0.82 and 81.35% of power factor and efficiency, respectively, were obtained in the operating point close to the value of rated current.
13

Análise em regime permanente de parques eólicos com máquinas SCIG e DFIG

Valencia Guerrero, Gabriel Andrés January 2014 (has links)
A geração de energia elétrica com fontes renováveis está em aumento e uma das que tem maior crescimento é a eólica. A instalação das máquinas que aproveitam este recurso pode trazer alguns problemas para a rede elétrica devido à intermitência da velocidade do vento. O presente trabalho tem por objetivo analisar o comportamento de dois tipos de aerogeradores que utilizam gerador de indução e sua interação com o sistema elétrico de potência. Os aerogeradores assíncronos analisados são o de velocidade variável com gerador de indução duplamente alimentado (Doubly-Fed Induction Generator-DFIG) e o de velocidade fixa com gerador de indução de rotor de gaiola de esquilo (Squirrel Cage Induction Generator-SCIG). O caso de estudo está baseado no parque eólico Jepirachi na Colômbia, o qual na atualidade tem aerogeradores de velocidade fixa. Para isto inicialmente foi feita a modelagem do parque eólico considerando alguns parâmetros dos aerogeradores comerciais de velocidade variável e velocidade fixa, junto com os principais componentes da rede elétrica da região para obter uma aproximação da mesma. Posteriormente realizaram-se simulações computacionais para obter o comportamento do sistema elétrico de potência alimentado por estes tipos de aerogeradores. Finalmente, foi realizada uma análise dos efeitos que produzem cada tipo de máquina, no fluxo de potência e no nível de tensão da rede elétrica funcionando em regime permanente, considerando os distúrbios ocasionados pelas mudanças da velocidade do vento. / The generation of electricity from renewable sources is increasing, one of the largest growth is the wind power. However the installation of the machines that leverage this resource could bring some problems to the grid due to the intermittency of the wind speed. This work analyzes the behavior of variable speed wind turbines with Doubly-Fed Induction Generator (DFIG) and fixed-speed wind turbines with Squirrel Cage Induction Generator (SCIG). The case study is based in Jepirachi wind farm in Colombia, that at the present has fixed-speed wind turbines with Squirrel Cage Induction Generator (SCIG). To do this study, initially the modeling of the wind farm considering some parameters of commercial wind turbines with variable speed and fixed speed, also modeling the main components of the electric grid of the region to obtain an approximation of it, after computer simulations we made in order to obtain the behavior of the electric power system powered by these types of turbines. Finally the analysis of the effects produced by each type of machine, in the power flow and the voltage level of the grid operating in steady state, but considering the disturbances caused by changes in wind speed are made.
14

Modelagem dinâmica e controle de um gerador tipo DFIG em redes de distribuição

Ávila, Manuel Ricardo Vargas January 2014 (has links)
Neste momento o Brasil possui uma das mais renováveis matrizes energéticas do mundo, mas o desafio de reduzir os níveis de emissão, permitir o crescimento econômico e atender a aproximadamente um milhão de pessoas sem energia elétrica no pais, requer a pesquisa e o desenvolvimento de novas tecnologias que possibilitem a utilização de fontes limpas e sustentáveis de energia, como é a energia eólica. A energia eólica é considerada, entre as alternativas renováveis existentes, a mais viável no mercado de energia, devido à baixa relação custo/benefício de exploração, tendo apresentado um crescimento exponencial ao longo dos anos. Os principais sistema eólicos classificam-se de acordo com sua operação em dois tipos: sistemas com operação a velocidade fixa e sistemas com operação a velocidade variável. Durante muitos anos a liderança do mercado foi para os geradores que operam a velocidade fixa, sendo a máquina mais usada o gerador de indução de rotor em gaiola (SCIG). A partir do ano 2000, a supremacia no mercado passou a ser para o gerador de velocidade variável. Hoje, tem-se dois tipos de geradores amplamente utilizados em sistemas eólicos que operam a velocidade variável: o gerador síncrono e o gerador de indução com rotor bobinado. Neste trabalho será estudada uma das máquinas que operam a velocidade variável e utilizam geradores de indução com rotor bobinado: o gerador de indução duplamente alimentado (DFIG). Sua importância é principalmente o controle independente da potência ativa e da potência reativa fornecida para a rede elétrica, e à operação com máxima eficiência na conversão de energia. Neste contexto, este trabalho apresenta uma análise comparativa de um sistema de geração utilizando máquinas do tipo DFIG com quatro estratégias de controle: controle da potência ativa e da tensão nos terminais da máquina, controle da potência reativa e da tensão nos terminais da máquina, controle da velocidade de rotação e da tensão nos terminais da máquina, controle da potência ativa e da potência reativa fornecidas pela máquina ao sistema. Esta análise é feita comparando o comportamento do sistema quando sujeito a diversas situações, tais como: variações da demanda de potência da carga elétrica, variações do torque mecânico e ocorrência de uma falta trifásica. O desempenho de sistemas de geração eólica com SCIG também é incluído nesta análise para ilustrar de maneira quantitativa os ganhos obtidos com o uso do DFIG. Os resultados obtidos ilustram as virtudes de cada uma das diferentes possibilidades de modos de operação do DFIG em um sistema de distribuição e permitem uma melhor compreensão da vantagem do desempenho do DFIG em relação à utilização do SCIG. / At present Brazil has one of the most renewable energy matrices in the world, but the challenge of reducing emission levels, allowing the economic growth, and helping about 1 million people without electric energy in the country, requires research and development of new technologies that enable the use of clean and sustainable energy sources, such as wind power. Wind energy is considered among the existing renewable alternatives the more viable in the energy market, due to the low cost / benefit ratio of exploitation, having experienced exponential growth over the years. The wind system are classified according to their operation into two types: operating systems with fixed speed and systems with variable speed operation. For many years the leadership in the market was for fixed speed generator, being the most used machine, the induction generator rotor cage (SCIG). From 2000, the leadership in the market was for variable speed wind turbine. Today, there are two types of wind generators widely used in systems that operate at variable speed: synchronous generator and generator with wound rotor induction. In this work we will study one of the machines that operate at variable speed and use induction generators with wound rotor: the doubly-fed induction generator (DFIG). Its importance is mainly the independent control of active power and reactive power supplied to the grid, and operating at maximum efficiency in energy conversion. In this context, this work presents a comparative analysis of a generation system using DFIG type machines with four control strategies: control of active power and voltage at the terminals of the machine, control of reactive power and voltage at the machine terminals, control the rotational speed and tension in the machine terminals, control of active power and reactive power supplied by the machine. This analysis is done by comparing the behavior of the system when subjected to various situations, such as variations in power demand of electric load, changes in the mechanical torque and the occurrence of a three-phase fault. The performance of wind power generation systems with SCIG is also included in this analysis to illustrate quantitatively the gains obtained using DFIG. The results illustrate the virtues of each of the different possible operating modes of the DFIG in a distribution system and allow a better understanding of the performance advantage of the machine DFIG over the use of the machine SCIG.
15

Diretrizes analíticas para projeto de geradores de indução de rotor tipo gaiola de esquilo

Nascimento, Carlos Sonier Cardoso do January 2014 (has links)
Comumente, as máquinas de indução são projetadas para atuarem como motores. Assim, a presente tese objetiva estudar, analisar e construir um protótipo de máquina de indução concebida para atuar, exclusivamente, como gerador de indução, ou seja, impulsionada acima da velocidade síncrona. As características operacionais ideais em regime permanente são elaboradas intentando diretrizes de projeto. Concomitantemente, o estudo apresenta e investiga modelagens analíticas obtidas por parâmetros concentrados e, também, modelagens numéricas realizadas pelo método dos elementos finitos. Para isto, um gerador de indução trifásico de 2,2 kW tem o rotor do tipo gaiola de esquilo com ranhuras assimétricas projetado e prototipado. O protótipo do gerador de indução visa melhores características de desempenho como o fator de potência e menores perdas, por exemplo, que uma máquina de indução de mesma potência projetada para atuar como motor, mas funcionando como gerador interligado à rede em regime permanente. Os resultados analíticos, numéricos e experimentais em regime permanente do protótipo do gerador de indução e de um motor de indução de mesma potência, mas funcionando como gerador interligado à rede, são apresentados e comparados. Os resultados experimentais obtidos mostram valores nominais de 0,77 e 83,04% de fator de potência e rendimento, respectivamente, para o funcionamento da máquina convencional no ponto de operação próximo ao valor de corrente nominal. Para a máquina de indução projetada como gerador, os valores nominais de 0,82 e 81,35% de fator de potência e rendimento, respectivamente, foram obtidos no ponto de operação próximo ao valor de corrente nominal. / Commonly, induction machines are designed to act as motors. Thus, the present thesis aims to study, analyze and build a prototype of an induction machine designed to work exclusively as induction generator, i.e. driven above synchronous speed. The optimal steady state operating characteristics are elaborated by bringing design guidelines. Concomitantly, this study investigates and presents analytical modeling obtained by lumped parameters and also numerical modeling carried out by the finite element method. Thus, a three-phase squirrel cage induction generator of 2.2 kW with asymmetric rotor slots has designed and prototyped. The prototype of the induction generator aims best performance characteristics such as power factor, for example, than an induction machine of the same power designed to act as a motor, but functioning as generator parallel with the grid. Analytical, numerical and experimental results in steady state operation of the induction generator prototype and of an induction motor of the same power, but functioning as generator parallel with the grid, are presented and compared. The experimental results show nominal values 0.77 and 83.04% of power factor and efficiency, respectively, for the conventional machine in the operating point close to the value of rated current. For the induction machine designed as a generator, the nominal values 0.82 and 81.35% of power factor and efficiency, respectively, were obtained in the operating point close to the value of rated current.
16

Comunicação sem fio aplicada ao controle das potências de aerogeradores de indução conectados à rede elétrica visando aplicações em smart grids

Cardoso, Jaqueline Gomes January 2016 (has links)
Orientador: Dr. Alfeu J. Sguarezi Filho / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2016. / A energia eólica é uma fonte de energia renovável com diversas vantagens e sua participação na matriz energética mundial está crescendo a cada ano. Nos últimos anos, as plantas eólicas têm passado por grandes mudanças devido às novas tecnologias desenvolvidas para as Smart Grids (SG). Cada vez mais, os sistemas de conversão de energia eólicos estão utilizando arquiteturas de comunicação mais desenvolvidas para possibilitar o compartilhamento de dados e medidas em fazendas eólicas inteligentes. Nesse contexto, a proposta desse estudo é um controle sem fio para um gerador de indução gaiola de esquilo (GIGE) de velocidade variável conectado coma rede elétrica. O sistema de comunicação sem fio é empregado para enviar as potências de referência para o controlador do GIGE com a confiabilidade necessária para garantir a qualidade da energia fornecida pelo aerogerador. Neste trabalho, no controle do gerador é utilizada a técnica de controle do Controle Direto de Torque (CDT) e controle orientado pela tensão (COT) para a conexão com a rede elétrica. Para o sistema de comunicação sem fio, foram utilizadas duas estratégias de baixo custo e ampla cobertura nacional, baseadas nas redes de dados GPRS e EGPRS. O desempenho do sistema é avaliado através de diversas simulações e testes. / Wind energy is a renewable source of energy with several advantages and the participation in the global energy matrix is increasing every year. In recent years, the wind farms were changing with the advance of new technologies developed for the Smart Grid (SG). Increasingly, wind energy conversion systems are using more developed communication architectures to enable data sharing and intelligent measures in wind farms. In this context, the purpose of this study is a wireless controller for a variable speed Squirrel Cage Induction Generator (SCIG) connected to the grid. The wireless system is used to send the reference powers for SCIG controller with the reliability needed to ensure the quality of the power supplied by the wind turbine. In this paper, in the generator's control is used the Control Direct Torque (CDT) technique and Control-Driven Voltage (COT) technique for connection to the power grid. For the wireless communication system, they used two low-cost strategies with national coverage, based on GPRS and EGPRS data networks. The system performance is evaluated through various simulations and tests.
17

Controle preditivo aplicado ao gerador de indução Gaiola de Esquilo conectado à rede elétrica para aplicações em energia eólica

Lunardi, Angelo dos Santos January 2017 (has links)
Orientador: Prof°. Dr Alfeu Joãozinho Sguarezi Filho / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2017. / Esta dissertação apresenta o controle preditivo aplicado ao gerador de indução conectado à rede elétrica com emprego de conversor back to back. Nesse caso, o conversor conectado ao gerador é acionado pela técnica de controle preditivo direto de torque. Por sua vez, o conversor da rede é acionado pelo controle preditivo direto de potência. Os controladores são projetados com base em modelo matemático dinâmico discretizado do gerador e da rede. Para validação do sistema proposto, foram implementadas no Sim- PowerSystems do Matlab/Simulink R os modelos matemáticos e os algoritmos de predição. Por m, foram também realizado teste experimentais no laboratório da universidade. Os resultados obtidos serão apresentados a m de demonstrar a melhora na resposta dinâmica do gerador. Para os resultados de simulação foi possível validar a melhora na corrente injetada na rede em comparação às técnicas tradicionais. / This dissertation presents the predictive control applied to the induction generator connected to the electric grid with the back-to-back converter. In this case, the converter connected to the generator is driven by the predictive direct torque control technique and the grid converter is driven by predictive direct power control. The controllers are designed from discrete dynamic generator and grid mathematical model. For the validation of the proposed system, mathematical models and prediction algorithms were implemented in SimPowerSystems of Matlab / Simulink R. Finally, experimental tests were also carried out in the university laboratory. The results obtained will be presented to present the improvement in the dynamic response of the generator, and for the simulation results, it was possible to validate the improvement in the current injected into the grid in relation to the traditional techniques.
18

Sistema de armazenamento aplicado a sistemas eólicos empregando conversores de fonte z conectados à rede elétrica

Navas, Michael Andrés Hernández January 2015 (has links)
Orientador: Dr. Alfeu J. Sguarezi Filho / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2015. / Neste trabalho apresenta-se uma configuração do sistema de armazenamento de energia com baterias aplicado a sistemas de geração de energia eólica empregando conversores de fonte Z conectados à rede elétrica. Os geradores de indução gaiola de esquilo, são frequentemente utilizados nos sistemas de geração de energia eólica, por sua robustez, simplicidade, peso menor e custo baixo. Este é conectado diretamente ao conversor de potência bidirecional back to back, pode fornecer potências ativa e reativa à rede elétrica. Além disso, é estudado o conversor de fonte Z aplicado nesta topologia. No entanto, a implantação de sistemas de armazenamento de energia com baterias nos sistemas de geração de energia eólica na atualidade é muito importante, devido à possibilidade de oscilações da tensão e corrente na rede elétrica, portanto, estes podem ajudar à estabilização das tensões, correntes e a frequência na rede elétrica. Este sistema é conectado ao conversor back to back por meio de um conversor elevador-abaixador de corrente contínua. Para controlar a velocidade no eixo do rotor no gerador de indução, a estratégia é baseada no controle direto de torque. Enquanto, para o conversor do lado da rede é empregada a técnica de controle orientado pela tensão. Para o banco de baterias é utilizado o controle da tensão no barramento de corrente contínua e do fluxo na corrente da bateria, utilizando controladores do tipo PI. Com os novos desenvolvimentos tecnológicos nas chaves de potência, são apresentadas topologias de conversores CC-CA como o conversor de fonte Z, este tipo de conversor corrige algumas limitações do conversor back to back, com as características de elevador/abaixador de tensão, sem o uso de dispositivos de comutação, são permitidos os curto-circuitos na chaves, empregando novas técnicas de modulação, e reduz a quantidade harmônica injetada na rede elétrica. Os estudos foram realizados por meio de técnicas de simulação computacional usando modelos matemáticos do sistema estudado para a validação das estratégias de controle empregadas em diferentes condições de operação. Para as simulações empregou-se a ferramenta computacional SimPowerSystems R do Matlab/Simulink R . / This paper presents a battery energy storage system applied to wind power generation based on Z-source inverter connected to the power grid. The squirrel cage induction generators, often used in wind power generation systems, for its robustness, simplicity, lower weight and low cost. This is connected directly to the bidirectional power converter back to back, therefore, and provides active and reactive powers to grid. In addition, it is studied the Z-source inverter applied in this topology. However, the implementation of battery energy storage systems in wind power generation systems, currently is very important, due to possibility of the voltage and current fluctuations in the power grid, so these may to stabilisation of current, voltage and frequency on the grid. This system is connected to back to back converter through a DC-DC converter (buck-boost). For the rotor speed control on induction generator, the strategy is based on direct torque control. While, for the grid side converter is employed the technique of voltage oriented control. For the battery bank voltage control is used on DC-link voltage and battery current flow, through PI type controllers. With the new technological developments in the keys of power, DC converters topologies are presented as the Z-source inverter, this type converter fixes some limitations of the converter back to back, with the characteristics of buck-boost voltage, without the use of switching devices, allowed short-circuits on converter, using new modulation techniques, and reduces the amount injected harmonic to power grid. The studies were performed by means of computer simulation techniques using mathematical models of studied system to validate the control strategies employed in different operating conditions. For the simulations was used the computational tool SimPowerSystems R do Matlab/Simulink R .
19

Análise de estabilidade de sistemas de potência em presença de altos níveis de penetração de energia eólica / Analysis of power system stability in presence of high levels of wind power penetration

Cortes, David Joel Figueroa 27 June 2014 (has links)
Atualmente, a energia eólica é uma das fontes renováveis mais reconhecidas, e sua penetração em sistemas elétricos de potência está se incrementando consideravelmente. Por consequência, a participação de turbinas eólicas em sistemas elétricos de potência tem se incrementado e pode influenciar o comportamento geral do sistema de potência. Portanto, é importante estudar o desempenho de turbinas eólicas em sistemas elétricos e sua interação com outros equipamentos de geração e cargas. O principal objetivo nesta dissertação é determinar o desempenho dinâmico de diferentes tecnologias ligadas nos sistemas elétricos considerando diferentes níveis de penetração e diferentes perturbações elétricas mediante simulações realizadas usando um toolbox de Matlab/Simulink, SimPowerSystems. As tecnologias avaliadas são (a) o gerador de indução duplamente alimentado com fator de potência unitário, (b) o gerador de indução duplamente alimentado com controle de tensão, (c) o gerador de indução de gaiola de esquilo com compensação baseada em condensadores, e (d) gerador de indução de gaiola de esquilo sem equipamentos auxiliares. Os fatores técnicos analisados são perfil de tensão em estado estacionário, as dinâmicas durante afundamentos e elevações de tensão, correntes de curto circuito, e incremento gradual nas cargas do sistema, para verificar a estabilidade de tensão da rede para pequenas perturbações. É proposta uma estratégia para promover uma integração efetiva de turbinas eólicas em sistemas de potência com altos níveis de penetração considerando diferentes normas de operação da rede para sistemas de transmissão e de distribuição. O objetivo nesta estratégia é o cumprimento dos requisitos para conexão de rede com a combinação de tecnologias, minimizando o valor do investimento. Os efeitos na estabilidade de sistemas de potência da fazenda eólica determinada com a metodologia proposta são comparados com os efeitos de uma fazenda eólica de igual capacidade de energia eólica considerando somente geradores de indução duplamente alimentados com controle de tensão. Para as analises realizadas neste trabalho são considerados os sistemas IEEE de 9 e 30 barras. / Nowadays, wind power is one of the most accepted renewable energy sources, and its penetration in electrical power systems is increasing considerably. Consequently, the participation of wind turbines in electrical power systems has increased and may influence the overall power system behavior. It is therefore important to study the performance of wind turbines in electrical power systems and their interaction with other generation equipment and loads. The main objective of this dissertation is to determine the dynamic performance of different wind turbines technologies connected in electrical system considering different penetration levels and electrical perturbations by simulations performed using a Matlab/Simulink toolbox, SimPowerSystems. The assessed technologies are (a) double fed induction generator with unity power factor, (b) double fed induction generator with voltage control, (c) squirrel cage induction generator with capacitor-based compensation, and (d) squirrel cage induction generator without ancillary devices. The technical factors analyzed are steady-state voltage profile, the dynamics during voltage sags and swells, short-circuit currents, and gradual increase in the system loading, in order to check the network small-disturbance voltage stability. A strategy to promote an effective integration of wind turbines into the power systems with high levels of wind power penetration regarding different grid code requirements in transmission and distribution networks is proposed. The objective in this strategy is fulfilling the grid code requirements with a technology combination, minimizing the invested value. The effects on power system stability of the wind farm, found by the proposed methodology, are compared with the effects that have the same installed capacity of wind power but only considering double fed induction generators with voltage control. The IEEE 9 bus transmission system and the IEEE 30 bus system are regarded for the analysis performed in this work.
20

Análise de estabilidade de sistemas de potência em presença de altos níveis de penetração de energia eólica / Analysis of power system stability in presence of high levels of wind power penetration

David Joel Figueroa Cortes 27 June 2014 (has links)
Atualmente, a energia eólica é uma das fontes renováveis mais reconhecidas, e sua penetração em sistemas elétricos de potência está se incrementando consideravelmente. Por consequência, a participação de turbinas eólicas em sistemas elétricos de potência tem se incrementado e pode influenciar o comportamento geral do sistema de potência. Portanto, é importante estudar o desempenho de turbinas eólicas em sistemas elétricos e sua interação com outros equipamentos de geração e cargas. O principal objetivo nesta dissertação é determinar o desempenho dinâmico de diferentes tecnologias ligadas nos sistemas elétricos considerando diferentes níveis de penetração e diferentes perturbações elétricas mediante simulações realizadas usando um toolbox de Matlab/Simulink, SimPowerSystems. As tecnologias avaliadas são (a) o gerador de indução duplamente alimentado com fator de potência unitário, (b) o gerador de indução duplamente alimentado com controle de tensão, (c) o gerador de indução de gaiola de esquilo com compensação baseada em condensadores, e (d) gerador de indução de gaiola de esquilo sem equipamentos auxiliares. Os fatores técnicos analisados são perfil de tensão em estado estacionário, as dinâmicas durante afundamentos e elevações de tensão, correntes de curto circuito, e incremento gradual nas cargas do sistema, para verificar a estabilidade de tensão da rede para pequenas perturbações. É proposta uma estratégia para promover uma integração efetiva de turbinas eólicas em sistemas de potência com altos níveis de penetração considerando diferentes normas de operação da rede para sistemas de transmissão e de distribuição. O objetivo nesta estratégia é o cumprimento dos requisitos para conexão de rede com a combinação de tecnologias, minimizando o valor do investimento. Os efeitos na estabilidade de sistemas de potência da fazenda eólica determinada com a metodologia proposta são comparados com os efeitos de uma fazenda eólica de igual capacidade de energia eólica considerando somente geradores de indução duplamente alimentados com controle de tensão. Para as analises realizadas neste trabalho são considerados os sistemas IEEE de 9 e 30 barras. / Nowadays, wind power is one of the most accepted renewable energy sources, and its penetration in electrical power systems is increasing considerably. Consequently, the participation of wind turbines in electrical power systems has increased and may influence the overall power system behavior. It is therefore important to study the performance of wind turbines in electrical power systems and their interaction with other generation equipment and loads. The main objective of this dissertation is to determine the dynamic performance of different wind turbines technologies connected in electrical system considering different penetration levels and electrical perturbations by simulations performed using a Matlab/Simulink toolbox, SimPowerSystems. The assessed technologies are (a) double fed induction generator with unity power factor, (b) double fed induction generator with voltage control, (c) squirrel cage induction generator with capacitor-based compensation, and (d) squirrel cage induction generator without ancillary devices. The technical factors analyzed are steady-state voltage profile, the dynamics during voltage sags and swells, short-circuit currents, and gradual increase in the system loading, in order to check the network small-disturbance voltage stability. A strategy to promote an effective integration of wind turbines into the power systems with high levels of wind power penetration regarding different grid code requirements in transmission and distribution networks is proposed. The objective in this strategy is fulfilling the grid code requirements with a technology combination, minimizing the invested value. The effects on power system stability of the wind farm, found by the proposed methodology, are compared with the effects that have the same installed capacity of wind power but only considering double fed induction generators with voltage control. The IEEE 9 bus transmission system and the IEEE 30 bus system are regarded for the analysis performed in this work.

Page generated in 0.0543 seconds