• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5839
  • 1830
  • 1659
  • 671
  • 549
  • 174
  • 164
  • 137
  • 127
  • 101
  • 91
  • 51
  • 51
  • 51
  • 51
  • Tagged with
  • 13921
  • 1647
  • 1399
  • 973
  • 864
  • 779
  • 779
  • 746
  • 724
  • 689
  • 650
  • 627
  • 623
  • 559
  • 537
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
621

Characterization of T lymphocyte antigens

Mallett, Susan January 1991 (has links)
No description available.
622

The developmental biology of Drosophila cell surfaces

Hinton, I. E. January 1987 (has links)
No description available.
623

The surface structures of uranium dioxide studied by elevated temperature STM

Muggelberg, Christiane January 1997 (has links)
No description available.
624

Quantum mechanical modelling of refractory transition metal carbide films

Tan, Keng Ean January 1995 (has links)
No description available.
625

Surface Mesh-Based Ultrasound Simulator For Spinal Interventions

Bartha, Laura 24 July 2013 (has links)
Purpose: Ultrasound is prevalent in image-guided therapy as a safe, inexpensive, and widely available imaging modality. However, extensive training in interpreting ultrasound images is essential for successful procedures. An open-source ultrasound image simulator was developed to facilitate the training of ultrasound-guided spinal intervention procedures, thereby eliminating the need for an ultrasound machine from the phantom-based training environment. Methods: Anatomical structures and surgical tools are converted to surface meshes for data compression. Anatomical data is converted from segmented volumetric images, while the geometry of surgical tools is available as a surface mesh. The pose of the objects are either constants or live measurements from a pose tracking device. Intersection points between the surface models and the ultrasound scan lines are determined with a binary space partitioning tree. The scan lines are divided into segments and filled with grey values determined by an intensity calculation accounting for material properties, reflection, and attenuation parameters defined in a configuration file. The scan lines are then converted to a regular brightness-mode ultrasound image. Results: The simulator was tested in a tracked ultrasound imaging system, with a mock transducer tracked by an Ascension TrakStar electromagnetic tracker, on a spine phantom. A mesh model of the spine was created from CT. The simulated ultrasound images were generated at a speed of 50 frames per second, and a resolution of 820 x 616 pixels on a PC with a 3.4 GHz processor. A human subject trial was conducted to compare the learning performance of novice trainees with real and simulated ultrasound in the localization of the facet joints of a spine phantom. With 22 participants split into two equal groups and each participant localizing 6 facet joints, there was no statistical difference in the performance of the two groups, indicating that simulated ultrasound could indeed replace the real ultrasound in phantom-based ultrasonography training for spinal interventions. Conclusion: The ultrasound simulator was implemented and integrated into the open-source Public Library for Ultrasound (www.plustoolkit.org) and SlicerIGT (www.SlicerIGT.org) toolkits / Thesis (Master, Computing) -- Queen's University, 2013-07-24 12:28:57.201
626

Fabtrication of Surface Plasmon Biosensors in CYTOP

Asiri, Hamoudi 19 September 2012 (has links)
This thesis describes work carried out on the research, development and implementation of new processes for the fabrication of surface plasmon waveguide biosensors. Fabrication of surface plasmon resonance (SPR) based waveguides embedded in a thick CYTOP cladding with the incorporation of fluidic channels was achieved with improved quality and operability compared to previous attempts. The fabrication flow was modified in key areas including lithography for feature definition, gold evaporation and the upper cladding deposition procedure. The combined result yielded devices with sharper resolution of waveguides, gold surfaces with minimal aberrations, reduced surface roughness and minimization of waveguide deformation due to reduction of solvent diffusion into the lower cladding. The fabricated waveguides consisted of a thin, 35 nm, patterned gold film, embedded in a thick, 18 µm, CYTOP fluoroploymer cladding. The gold devices were exposed by O2 plasma etching through the upper cladding to form fluidic channels for the facilitation of flow of an index matched sensing medium. Optical and physical characterization of devices revealed structures of significantly improved quality over previous attempts, rendering the platform competitive for biosensing applications.
627

Phase transitions of xenon adsorbed on graphite

Zerrouk, Taha-El-Amine January 1993 (has links)
No description available.
628

Specular reflection from interfaces

Purcell, Isabella Pauline January 1994 (has links)
No description available.
629

Advanced on-line and off-line process control for surface-engineered applications

Dowey, Stephen James January 1999 (has links)
No description available.
630

Electrical properties of Langmuir monolayers and deposited Langmuir-Blodgett films

Oliveira Junior, Osvaldo Novais de January 1990 (has links)
No description available.

Page generated in 0.0242 seconds