• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de resistência ao cisalhamento em peças de seções circulares vazadas utilizando a teoria do campo de compressão modificada.

Queiroz Junior, Francinaldo de Oliveira 29 August 2014 (has links)
Submitted by Israel Vieira Neto (israel.vieiraneto@ufpe.br) on 2015-03-05T17:09:49Z No. of bitstreams: 2 DISSERTAÇÃO Francinaldo Junior.pdf: 3351371 bytes, checksum: d51e55bbc480ac940c502e8b1eace90f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T17:09:49Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Francinaldo Junior.pdf: 3351371 bytes, checksum: d51e55bbc480ac940c502e8b1eace90f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014-08-29 / Peças de concreto armado com seções transversais circulares vazadas são usadas com muita frequência na engenharia. Em Recife, particularmente, o número de edificações com mais de 30 pavimentos tem apresentado crescimento notável; Muitas dessas edificações são projetadas sobre fundações de estacas circulares vazadas. Os elementos estruturais dessas edificações devem transmitir, de forma segura, momentos, carregamentos axiais e esforços cortantes para as suas fundações. Desta forma, com o aumento da altura das edificações, ocorre também o aumento dos esforços cisalhantes que são transmitidos para suas fundações. Por outro lado, estes elementos vazados são mais críticos em relação ao cisalhamento devido ao seu núcleo vazio. As normas e diretrizes para avaliação da resistência ao cisalhamento de peças com tais seções transversais são praticamente não existentes, e a maioria dos requisitos das normas existentes, dentre elas a NBR 6118, foram baseados em modelos de cisalhamento para seções retangulares. Este estudo buscou avaliar, de forma comparativa, a resistência ao cisalhamento de peças com seções transversais circulares vazadas, obtidas de ensaios experimentais encontrados na literatura, com valores calculados utilizando a Teoria do Campo de Compressão Modificada através da norma canadense (CSA A23.3-04). Ao final, foi proposto, baseado nas normas existentes e nos dados experimentais, parâmetros para avaliação da altura útil, d, e largura efetiva, bw, a serem sugeridos para a NBR 6118, de forma a possibilitar o calculo das forças cortantes resistentes em peças com seções circulares vazadas, e ao mesmo tempo garantir que cada resistência calculada seja menor que a obtida experimentalmente.
2

Estacas de seção circular semienterradas submetidas a cargas laterais

FERREIRA, Priscila Feitosa de Sá 24 April 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-07-31T19:30:12Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Priscila Feitosa de Sá Ferreira.pdf: 7224560 bytes, checksum: c24277ade9dbd50cb5253b8573959668 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-07-31T20:47:10Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Priscila Feitosa de Sá Ferreira.pdf: 7224560 bytes, checksum: c24277ade9dbd50cb5253b8573959668 (MD5) / Made available in DSpace on 2018-07-31T20:47:10Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Priscila Feitosa de Sá Ferreira.pdf: 7224560 bytes, checksum: c24277ade9dbd50cb5253b8573959668 (MD5) Previous issue date: 2017-04-24 / O presente trabalho tem como objetivo propor quatro modelos de análise diferentes para o dimensionamento de estacas semienterradas de seção circular submetidas a cargas laterais com a consideração da não-linearidade física do material (NLF) e da não-linearidade geométrica da estrutura (NLG). Estes modelos, chamados de Níveis de Aproximação (NdA), estão organizados em ordem crescente de precisão da análise, partindo de um nível inicial, com maiores simplificações, até um nível final, com uma modelagem mais realista. No NdA I, a estaca semienterrada é tratada como uma coluna engastada na base e livre na ponta, com base na Técnica do Engastamento Virtual. O cálculo dos esforços resistentes é feito com base no método do pilar-padrão com curvatura aproximada, proposto pela norma brasileira. No NdA II, um programa comercial de análise tridimensional de estruturas é utilizado. Neste programa, o solo é representado de maneira discreta através de uma série de molas de comportamento elástico e linear (baseadas no Modelo de Winkler). A NLF é tratada de maneira aproximada através de um coeficiente, aplicado ao momento de inércia bruto, que simula a diminuição da rigidez do concreto. A NLG é tratada internamente pelo programa através do processo iterativo P-delta. No NdA III, é utilizado um programa elaborado neste trabalho que considera as não-linearidades e a interação solo-estrutura através da equação da viga sobre base elástica, cuja solução é dada a partir do Método das Diferenças Finitas. A NLF, neste modelo, foi considerada através de diagramas momento-curvatura. A NLG e a interação solo-estrutura (Modelo de Winkler) são consideradas diretamente na formulação da equação diferencial. Por fim, o NdA IV utiliza um programa comercial de análise não-linear de estruturas de pontes através de elementos finitos. A NLF é tratada pela integração das curvas de tensãodeformação e a NLG é modelada usando momentos P-delta. A consideração da interação solo-estrutura, neste modelo, é feita através de modelos de curvas p-y. Estes quatro modelos foram aplicados a dois exemplos distintos: um considerando apenas um pilar engastado na base e livre no topo (livre da interação solo-estrutura) e outro considerando uma estaca semienterrada em solo arenoso. Os resultados obtidos pelos quatro métodos foram bastante satisfatórios e se mostraram coerentes entre si, apresentando-se dentro do esperado para cada grau de refinamento da análise. / The present work proposes four different analysis models for the design of partly buried piles of circular section subjected to lateral loads with consideration of the physical nonlinearity of the material (PNL) and the geometric nonlinearity of the structure (GNL). These models, called Levels of Approximation (LoA), are organized in increasing order of accuracy, starting from an initial level, with greater simplifications, to a final level, which is more realistic. In LoA I, the partly buried pile is treated as a column fixed at the base and free at the top, based on the Virtual Clamping Technique. Strength computation is based on the standard column method with approximate curvature, proposed by the Brazilian Code. In LoA II, a commercial three-dimensional structure analysis program is used. In this program, the soil is represented discreetly through a series of elastic and linear springs (based on the Winkler Model). The PNL is approximately treated by a factor, applied to the gross moment of inertia, which simulates the decrease of rigidity of the reinforced concrete due to cracking and nonlinear constitutive properties. The GNL is internally handled by the program through the iterative P-delta process. The third proposed LoA is a program developed in this work that considers the non-linearities and the soil-structure interaction through the equation of the beam on elastic foundation. The equation is solved numerically, with the application of the Finite Differences Method. The PNL, in this model, was considered through moment-curvature diagrams computed internally for the section under analysis, which were used to determine the stiffness of the pile as a function of the lateral displacement. The GNL and the soil-structure interaction (also by Winkler Model) are considered directly in the equation. Finally, LoA IV uses a commercial program of nonlinear analysis of bridge structures through finite elements. The PNL is treated by integrating stress-strain curves into the cross-section analyzed and the GNL is modeled using P-delta moments. Consideration of the soil-structure interaction in this model is made through p-y curves models. These four models were applied to two distinct examples: one considering only one column fixed at the base and free at the top (free of soil-structure interaction) and another one considering a partly buried pile in sand. The results obtained by the four methods were very satisfactory and were shown to be coherent with each other, in line with the expected for each degree of refinement of the analysis.
3

Análise teórico-experimental de pilares mistos preenchidos de seção circular / Theoretical and experimental analysis of circular concrete-filled steel tubular columns

Oliveira, Walter Luiz Andrade de 06 June 2008 (has links)
Os pilares mistos preenchidos são elementos estruturais constituídos por um tubo de aço preenchido com concreto de qualidade estrutural. O objetivo principal do trabalho foi estudar o comportamento dos pilares mistos preenchidos de seção circular. Para isso, foi avaliada a influência da resistência à compressão do concreto (fc), da esbeltez do pilar (L/D), da espessura do tubo de aço (t) e da forma de introdução do carregamento, se no núcleo de concreto ou na seção mista do pilar. Foram feitos ensaios experimentais de 64 pilares mistos preenchidos, submetidos à força de compressão centrada. Os resultados de capacidade resistente obtidos foram avaliados e comparados com os resultados de previsão segundo os procedimentos normativos estrangeiros do EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001 e do Projeto de Revisão da Norma Brasileira (PR-NBR 8800, draft 2008). Os resultados previstos foram maiores que os experimentais para os procedimentos do ANSI/AISC e da NBR e menores para os procedimentos do EC4 e do CAN/CSA. A partir da comparação dos valores de capacidade resistente experimentais e normativos, foi desenvolvido um estudo de confiabilidade dos valores de força resistente obtidos segundo as equações de dimensionamento dessas normas, por meio da estimativa do erro de modelo inerente a cada uma. Os resultados mostraram que o EC4 apresenta os índices de confiabilidade mais uniformes. Além disso, foi feita uma modelagem numérica dos pilares mistos preenchidos com relação L/D = 10, buscando obter o valor da capacidade resistente desses pilares e compará-los com os resultados experimentais. Embora o modelo numérico tenha representado adequadamente o comportamento dos pilares preenchidos esbeltos, os valores de força última foram inferiores aos experimentais. / Concrete-filled steel tubular columns are structural elements made of a steel tube filled with structural concrete. The main objective of this work was study the global behavior of concrete-filled steel tubular columns. For this, some variables were evaluated: concrete compressive strength (fc), length-to-diameter ratio (L/D), diameter-to-thickness ratio (D/t) and the type of load application (on concrete core or on composite cross section). Tests of 64 concrete filled columns were performed. The columns were subjected to axial load. The results of experimental compressive strength were compared to results from three different international codes (EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001) and the national NBR 8800, draft 2008. The results showed, in general, a conservative behavior of values predicted by NBR and ANSI/AISC e non-conservative values by EC4 and CAN/CSA. Based on comparisons between experimental values and codes predictions, an error model variable was estimated to each code and a reliability analysis was performed. The results indicate that the EC4 is the best code with less tendentious behavior of its design equation. A numerical analysis of columns with slenderness (L/D) equal to 10 was carried out to try to predict the peak load of columns and compare the results with those from experimental analysis. Althougth the results of the numerical analysis had a good match to the experimental ones, the values, in average, were conservatives.
4

Análise teórico-experimental de pilares mistos preenchidos de seção circular / Theoretical and experimental analysis of circular concrete-filled steel tubular columns

Walter Luiz Andrade de Oliveira 06 June 2008 (has links)
Os pilares mistos preenchidos são elementos estruturais constituídos por um tubo de aço preenchido com concreto de qualidade estrutural. O objetivo principal do trabalho foi estudar o comportamento dos pilares mistos preenchidos de seção circular. Para isso, foi avaliada a influência da resistência à compressão do concreto (fc), da esbeltez do pilar (L/D), da espessura do tubo de aço (t) e da forma de introdução do carregamento, se no núcleo de concreto ou na seção mista do pilar. Foram feitos ensaios experimentais de 64 pilares mistos preenchidos, submetidos à força de compressão centrada. Os resultados de capacidade resistente obtidos foram avaliados e comparados com os resultados de previsão segundo os procedimentos normativos estrangeiros do EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001 e do Projeto de Revisão da Norma Brasileira (PR-NBR 8800, draft 2008). Os resultados previstos foram maiores que os experimentais para os procedimentos do ANSI/AISC e da NBR e menores para os procedimentos do EC4 e do CAN/CSA. A partir da comparação dos valores de capacidade resistente experimentais e normativos, foi desenvolvido um estudo de confiabilidade dos valores de força resistente obtidos segundo as equações de dimensionamento dessas normas, por meio da estimativa do erro de modelo inerente a cada uma. Os resultados mostraram que o EC4 apresenta os índices de confiabilidade mais uniformes. Além disso, foi feita uma modelagem numérica dos pilares mistos preenchidos com relação L/D = 10, buscando obter o valor da capacidade resistente desses pilares e compará-los com os resultados experimentais. Embora o modelo numérico tenha representado adequadamente o comportamento dos pilares preenchidos esbeltos, os valores de força última foram inferiores aos experimentais. / Concrete-filled steel tubular columns are structural elements made of a steel tube filled with structural concrete. The main objective of this work was study the global behavior of concrete-filled steel tubular columns. For this, some variables were evaluated: concrete compressive strength (fc), length-to-diameter ratio (L/D), diameter-to-thickness ratio (D/t) and the type of load application (on concrete core or on composite cross section). Tests of 64 concrete filled columns were performed. The columns were subjected to axial load. The results of experimental compressive strength were compared to results from three different international codes (EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001) and the national NBR 8800, draft 2008. The results showed, in general, a conservative behavior of values predicted by NBR and ANSI/AISC e non-conservative values by EC4 and CAN/CSA. Based on comparisons between experimental values and codes predictions, an error model variable was estimated to each code and a reliability analysis was performed. The results indicate that the EC4 is the best code with less tendentious behavior of its design equation. A numerical analysis of columns with slenderness (L/D) equal to 10 was carried out to try to predict the peak load of columns and compare the results with those from experimental analysis. Althougth the results of the numerical analysis had a good match to the experimental ones, the values, in average, were conservatives.

Page generated in 0.0369 seconds